D22 - Air Quality
The promotion of knowledge, the development of test methods, practices, guides, and terminology pertaining to sampling and analysis of atmospheres, interpretation of data, the standardization of recognized and practiced methods for measurement of atmospheric quality, and sponsoring of discussions among those active in the study of air quality. The work of the Committee will be coordinated with other ASTM Committees and other organizations having mutual interest.
Air Quality
The promotion of knowledge, the development of test methods, practices, guides, and terminology pertaining to sampling and analysis of atmospheres, interpretation of data, the standardization of recognized and practiced methods for measurement of atmospheric quality, and sponsoring of discussions among those active in the study of air quality. The work of the Committee will be coordinated with other ASTM Committees and other organizations having mutual interest.
General Information
SIGNIFICANCE AND USE
5.1 Environmental (including workplace) samples obtained during the assessment or mitigation of lead hazards from buildings and related structures are analyzed to determine lead content in media of concern. This test method is intended for use with other ASTM standards (see 2.1) that address the collection and preparation of samples (airborne particulate, dusts by wipe and micro-vacuuming, dried paint chips, and soils) that are obtained during the assessment or mitigation of lead hazards. This test method may be used to analyze samples collected from various environments, such as workplaces, buildings, indoor or outdoor settings, construction sites, housing, and so on.
5.2 This test method may also be used to analyze similar samples from other environments such as toxic characteristic extracts of waste sampled using Guide E1908, and soil and sludge as prepared for analysis using U.S. EPA SW-846 Test Method 1311 (5).
5.3 This test method can be relied upon by laboratories seeking accreditation for lead analysis by means of GFAAS.
SCOPE
1.1 This test method covers the determination of lead (Pb) in airborne particulate, dust by wipe and micro-vacuuming, paint, and soil collected in and around buildings and related structures using graphite furnace atomic absorption spectrometry (GFAAS).
1.2 This test method contains directions for sample analysis, as well as quality assurance (QA) and quality control (QC), and may be used for purposes of laboratory accreditation and certification.
1.3 No detailed operating instructions are provided because of differences among various makes and models of suitable GFAAS instruments. Instead, the analyst shall follow the instructions provided by the manufacturer of the particular instrument.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4.1 Exception—The SI and inch-pound units shown for wipe and micro-vacuuming sampling data are to be individually regarded as standard for wipe and micro-vacuuming sampling data.
1.5 This test method contains notes which are explanatory and not part of the mandatory requirements of this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Some PFAS have been implicated in adverse human health impacts (4, 5, 6). Therefore, quantifying PFAS concentrations in indoor air is important for accurate and meaningful exposure analysis and risk assessments.
5.2 PFAS found in air can have a wide range of chemical characteristics that will impact sampling practice selection. For example, estimated vapor pressure values can vary by ten orders of magnitude, while estimated Henry’s Law constants can vary by five orders of magnitude (Table 1). This means that sampling and analytical methods that are appropriate for one PFAS compound may not be appropriate for other PFAS compounds. Hence, prior to sampling and selecting analytic methods for PFAS measurement in indoor air, it is critical to establish that the chosen PFAS sampling method(s) is appropriate for the target compound(s), the sampling location, and the environmental conditions.
5.3 The measurement of PFAS in indoor air is an active and growing research topic. Understanding of PFAS properties, sampling and analytic approaches and techniques is constantly evolving. This includes the determination of physical-chemical properties of many PFAS, which may not even have been measured experimentally or which have a wide range of experimentally determined properties (that is, 8:2 FTOH in Table 1). This guide describes methods that are in use at the time of publication.
5.4 PFAS in indoor air may come from a wide range of sources, including consumer products, building materials, food packaging, outdoor air, and other miscellaneous sources. PFAS is also commonly quantified in indoor dust. There are several methods that quantify these chemicals in solid and liquid media including, but not limited to Guide E3302, Test Method D7968, Test Method D7979, Test Method D8421, Test Method D8535, US EPA 533, and US EPA 537.1. US EPA OTM-45 quantifies some PFAS in the combined gas and particle phases of stationary sources, such as incinerator stack sampling.
5.5 Thi...
SCOPE
1.1 This guide describes methods for determining Per- and Polyfluoroalkyl Substances (PFAS) concentrations in indoor air.
1.2 This guide is focused on PFAS measurement technologies applicable to indoor air (including in vehicles and indoor workplaces) and other relevant air volumes such as, air in chambers, bags, or both. The described technologies were developed for indoor air; they may or may not be applicable to other types of air samples.
1.3 This guide describes available technologies and methods that can be used to measure indoor air PFAS concentrations in the gaseous or particulate phases, or both, in indoor air.
1.4 This guide describes each method and its advantages and limitations.
1.5 This guide does not attempt to differentiate between the effectiveness of the methods nor determine equivalence of the methods.
1.6 The sorbent-based sampling strategies addressed in this guide are for PFAS compounds with a molecular mass greater than 200 g mol-1 (1, 2, 3).2 Compounds less than 200 g mol-1, such as CF4, C2F6, or PFAS degradation products may require real-time analytical methods described in this guide or other methods that are not presented here.
1.7 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide21 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Although this practice is intended for the collection of dried paint samples in and around buildings and related structures for the subsequent determination of lead content, this practice may also be used to collect paint samples from other structures for lead analysis.3
5.2 The variability associated with the sampling of dried paint is generally considered to be far higher than the variability associated with the analyses of the paint specimens. Therefore, it is essential that sample collection be properly controlled to produce representative and meaningful samples.
5.3 These samples are collected in a manner that will permit subsequent digestion using sample preparation techniques such as Practices E1645 or E1979 and determination of lead using laboratory analysis techniques such as inductively coupled plasma atomic emission spectrometry (ICP-AES) (see Test Method E3203) or flame atomic absorption spectrometry (FAAS) (see Test Method E3193).
SCOPE
1.1 This practice covers the collection of samples of dried paint and other coatings from buildings and related structures.
1.2 This practice is used to collect samples for subsequent determination of lead on an area basis (milligrams of lead per area sampled) or concentration basis (milligrams of lead per gram of dried paint collected or mass percent of lead in the paint sample collected).
1.3 This practice does not address the sampling design criteria (that is, a sampling plan that includes the number and location of samples) that are used for risk assessment and other lead hazard activities. See Guide E2115 or Practices E2271/E2271M or E3074/E3074M.
1.4 This practice contains notes that are explanatory and are not part of the mandatory requirements of this practice.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. A specific warning statement is given in 7.4.1.1.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice provides procedures to generate and document QC data for ensuring that an XRF is operating within acceptable tolerances throughout the testing period when being used to collect lead results during a lead-based paint (LBP) inspection for the purposes of generating lead classification results.
5.2 This practice is intended to supplement XRF instrument manufacturer protocols and PCSs4 through the use of QA and QC procedures to provide uniform lead testing practices among the wide variety of available field-portable XRF instruments.
Note 1: The United States requires that an XRF used to perform a lead-based paint inspection in housing is to be utilized according to the PCS for the particular instrument model in use.
5.3 While the QC results collected using this practice can provide assurances that an XRF instrument is operating within acceptable tolerances, this practice does not determine an actual level of confidence for a classification result obtained from an XRF measurement.
5.4 This practice does not address selection of test locations or representative sampling for leaded paint. Additional information on conducting measurements of lead in leaded paint or other coatings may be found in Guide E2115 and the HUD Guidelines, Chapter 7.
5.5 This practice involves the use of field-portable XRF instruments that may contain radioactive materials or X-ray tubes that emit X-rays or gamma rays, or both. These instruments are intended for use only by qualified, trained personnel.
5.6 The use of field-portable XRF instruments for measurement of lead may not accurately reveal low but still potentially hazardous levels of lead.
SCOPE
1.1 This practice covers the collection and documentation of quality control (QC) measurements for determining acceptable levels of instrumental performance when using field-portable energy-dispersive X-ray fluorescence spectrometry devices (XRFs) for the purposes of generating lead classification results from measurements on paint and other coating films within buildings and related structures.
1.1.1 This practice is not designed to determine the presence of a hazard as defined by authorities having jurisdiction in the United States or other jurisdictions. See Guide E2115 and the HUD Guidelines for more information.
1.2 QC procedures covered in this provisional practice include the performance of calibration checks, substrate bias checks, and specific instructions for documenting the collected data for later use in reporting the results.
1.3 No detailed operating instructions are provided because of differences among the various makes and models of suitable instruments. Instead, the analyst is to follow the instructions provided by the manufacturer of the particular XRF device or other relevant sources of information on XRF operation.
1.4 This practice contains notes which are explanatory and are not part of the mandatory requirements of this provisional practice.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
- Standard7 pagesEnglish language
ABSTRACT
This specification covers requirements for wipe sampling materials that are used to collect settled dusts on surfaces for the subsequent determination of lead. The wipes shall be tested for conformance to background lead, lead recoverability, collection efficiency, ruggedness which shall be determined using butted vinyl-composite floor tiles as a test surface, moisture content, coefficient of variation in mass, linear dimensions such as mean area and mean length, and mean thickness requirements.
SCOPE
1.1 This specification covers requirements for wipes that are used to collect settled dusts on surfaces for the subsequent determination of lead.
1.2 For wipe materials used for the determination of beryllium in surface dust refer to Specification D7707. This is mentioned to insure that users of wipes recognize that there is some relationship between the analytical backgrounds found in wipes and the analyte of interest.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification3 pagesEnglish language
- Technical specification3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 A clearance examination of abatement areas and other areas associated with other lead-hazard control activities, or building maintenance or modification activities in single-family detached dwellings, individual units in multifamily dwellings, common areas or exterior sites, and child-occupied facilities is performed to determine that the clearance area is adequately safe for reoccupancy.
4.2 It is the responsibility of the user of this standard to assure that all regulatory, contractual and personnel requirements are met prior to conduct of a clearance examination. At a minimum, users of this standard shall be trained in its use and in safe practices for its conduct.
Note 2: Authorities having jurisdiction may have certification or specific training requirements, or both.
4.3 This practice is one of a set of standards developed for lead hazard management activities. The visual assessment procedures required in this practice are found in Practice E2255/E2255M and the record keeping requirements are found in Practice E2239.
4.4 Although this practice was primarily developed for dwellings and for other child-occupied facilities, this practice may be also applied to nonresidential buildings and related structures by agreement between the client and the individual conducting the clearance examination.
4.5 This practice may be used by owners and property managers, including owner-occupants, and others responsible for maintaining facilities. It may also be used by lead hazard management consultants, construction contractors, labor groups, real estate and financial professionals, insurance organizations, legislators, regulators, and legal professionals.
4.6 This practice does not address whether lead-hazard reduction activities or other building modification or maintenance work were performed properly.
SCOPE
1.1 This practice covers visual assessment for the presence of deteriorated paint, surface dust, painted debris, and paint chips with environmental sampling of surface dust to determine whether a lead hazard exists at the time of sample collection, following lead-hazard reduction activities, or other building maintenance and modification activities.
1.2 This practice addresses clearance examination of single-family detached dwellings (including exterior structures, such as fences), individual units in multifamily dwellings, common areas or exterior sites, and child-occupied facilities.
1.3 This practice also addresses clearance examinations that may include soil sampling, for example when soil abatement has been performed.
1.4 This practice includes a procedure for determining whether regulatory requirements for lead clearance levels for dust and, where warranted, soil have been met, and consequently, whether a clearance area passes or fails a clearance examination.
Note 1: This practice is based on that portion of “clearance” described for the United States in 40 CFR Part 745 for abatement, and in 24 CFR Part 35 for lead-hazard reduction activities other than abatement.
1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Tr...
- Standard8 pagesEnglish language
- Standard8 pagesEnglish language
SCOPE
1.1 This specification covers performance criteria for ambient outdoor air quality sensors based on the evaluation described in Practice D8406.
1.2 This specification does not apply to sensors or instruments that remotely measure atmospheric pollutants using open path, lidar, or imaging technology.
1.3 This specification is for sensors that alone or in combination measure outdoor criteria pollutants in ambient air: particulate matter (PM2.5 and PM10), sulfur dioxide (SO2), ozone (O3), carbon monoxide (CO), or nitrogen dioxide (NO2) at concentrations that are relevant to public health.
1.4 Evaluation is to be performed by a competent entity able to demonstrate that it operates in conformity with internationally accepted test laboratory quality standards such as ISO/IEC 17025. Normally, it is expected that the entity undertaking the performance evaluation under Practice D8406 will perform the evaluation according to this specification.
1.5 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The measurement of particle-bound, oxidized, elemental, and total mercury in stationary-source flue gases provides data that can be used for emissions assessments and reporting, the certification of continuous mercury monitoring systems, regulatory compliance determinations and research programs associated with dispersion modelling, deposition evaluation, human health and environmental impact assessments. Particle-bound, oxidized, and elemental mercury measurements before and after control devices may be necessary for optimizing and evaluating the mercury removal efficiency of emission control technologies.
5.2 This test method was developed initially for the measurement of mercury in coal-fired power plants and has been extensively validated for that application. Since the introduction of this method, it has been extensively used on other combustion sources such as cement kilns and waste incinerators. With additional procedures given in this standard, it is also applicable to sources having a flue gas composition with high levels of hydrochloric acid, and low levels of sulfur dioxide (Section 16).
SCOPE
1.1 This test method applies to the determination of elemental, oxidized, particle-bound, and total mercury emissions from stationary combustion sources.
1.2 This test method is applicable to elemental, oxidized, particle-bound, and total mercury concentrations ranging from approximately 0.5 μg/Nm3 to 100 μg/Nm3.
1.3 This test method describes equipment and procedures for obtaining samples from effluent ducts and stacks, equipment and procedures for laboratory analysis, and procedures for calculating results.
1.4 This test method is applicable to sampling elemental, oxidized, and particle-bound mercury in flue gases of coal-fired stationary sources. It may not be suitable at all measurement locations, particularly those with high particulate loadings, as explained in Section 16.
1.5 Method applicability is limited to flue gas stream temperatures within the thermal stability range of the sampling probe and filter components.
1.6 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.7 This standard requires users to be familiar with EPA stack-gas sampling procedures as stated in EPA Methods 1–4, Method 5, and Method 17.
1.8 The method requires a high level of experience and quality control both in the field testing and analytical procedures to obtain high quality data.
1.9 Warning—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Use caution when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. The potential exists that selling mercury or mercury-containing products, or both, is prohibited by local or national law. Users must determine legality of sales in their location.
1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard21 pagesEnglish language
- Standard21 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice is intended for the collection of settled dust samples in and around buildings and related structures for the subsequent determination of lead content in a manner consistent with that described in the HUD Guidelines and 40 CFR 745.63. The practice is meant for use in the collection of settled dust samples that are of interest in clearance, hazard assessment, risk assessment, and other purposes.
5.2 Use of different pressures applied to the sampled surface along with the use of different wiping patterns contribute to collection variability. Thus, the sampling result can vary between operators performing collection from identical surfaces as a result of collection variables. Collection for any group of sampling locations at a given sampling site is best when limited to a single operator.
5.3 This practice is recommended for the collection of settled dust samples from hard, relatively smooth, nonporous surfaces. This practice is less effective for collecting settled dust samples from surfaces with substantial texture such as rough concrete, brickwork, textured ceilings, and soft fibrous surfaces such as upholstery and carpeting.
SCOPE
1.1 This practice covers the collection of settled lead-containing dust on surfaces using the wipe sampling method. These samples are collected in a manner that will permit subsequent extraction (see Practices E1644 and E1979) and determination of lead using laboratory analysis techniques such as atomic spectrometry (see Test Methods E3193/E3193M and E3203). For collection of settled dust samples for determination of lead and other metals, use Practice D6966.
1.2 This practice does not address the sampling design criteria (that is, sampling plan which includes the number and location of samples) that are used for clearance (see Practices E2271/E2271M and E3074/E3074M), lead hazard evaluation, or risk assessment (see Guide E2115), and other purposes. To provide for valid conclusions, sufficient numbers of samples should be obtained as directed by a sampling plan.
1.3 This practice contains notes that are explanatory and are not part of the mandatory requirements of this practice.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Although this practice is intended for the collection of soil samples from bare areas in and around buildings, this practice may also be used to collect soil samples from other areas and environments.
5.2 This practice limits soil collection to approximately the top 1.5 cm (0.6 in.) of soil surface.
5.3 These samples are collected in a manner that will permit subsequent digestion using sample preparation techniques such as Practices E1726 or E1979 and determination of lead using laboratory analysis techniques such as Test Methods E3193 or E3203.
SCOPE
1.1 This practice covers the collection of bare soil samples from areas around buildings and related structures using coring and scooping methods.
1.2 This practice may not be suitable for collection of soil samples from areas that are paved or otherwise covered with grass, mulch, or the like. See Guide E2115 or Practices E2271/E2271M or E3074/E3074M.
1.3 This practice does not address the sampling design criteria (that is, a sampling plan that includes the number and location of samples) that are used for risk assessment and other lead hazard activities.
1.4 This practice contains notes that are explanatory and are not part of the mandatory requirements of this practice.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This standard primarily addresses encapsulant products for residential and child-care facilities. It may also be appropriate for some commercial buildings.
4.2 Encapsulation provides a means of protecting occupants from exposure to lead in paint in buildings that are likely to remain standing for a long period of time. This nondestructive abatement strategy is useful in situations in which the primary structure needs to remain intact for either historical or economic reasons. Encapsulation offers an abatement strategy that may be more cost effective than abatement by removal of the paint.
4.3 There are many environmental and use conditions that affect leaded paint liquid coating encapsulation products, and different types of liquid coating encapsulation products have been developed specifically to meet the requirements of the various conditions. Product types include non-reinforced liquid coatings, as well as products for interior or exterior use. These products may be applied over many different surfaces coated with one or more layers of leaded paint and possibly other coatings. Encapsulation products in service are subjected to many kinds of wear. Various colors and finishes are also available. This guide is intended to assist the purchaser in determining which product is most appropriate for the specific conditions under which the product will be used.
4.4 As described in this guide, an encapsulation product must be compatible with the surface to which it is applied. An encapsulation product must bond to the surface coating, and not cause the subsurface layers to separate or deteriorate.
SCOPE
1.1 This guide is intended to provide building users such as private building owners, contractors, architects, homeowners, and regulatory authorities with assistance in selecting an appropriate liquid coating encapsulation product for architectural residence and child-care facility use situations for abating leaded paint. This guide also provides information that can be used to assist in the following: (1) determining whether a painted surface is suitable for encapsulation, (2) applying a liquid coating encapsulation product, (3) evaluating installed liquid coating encapsulation products, and (4) maintaining the encapsulated surface.
1.2 This guide applies to any liquid-applied product that relies primarily on adhesion for attachment to the surface and is designed to reduce human exposure to lead in paint.
1.3 This guide is not intended for use as a training manual. The information contained herein is not all-inclusive and does not provide comprehensive instructions for the selection, application, or maintenance of specific liquid coating encapsulation products. This guide is intended to supplement information supplied by encapsulation product manufacturers and safety requirements established by law. The user of this guide shall refer to the encapsulation product manufacturer’s instructions for encapsulation product application and maintenance.
1.4 This guide does not cover minimum material performance requirements for liquid coating encapsulation products. Performance specifications for non-reinforced liquid coating encapsulation products are provided in Specification E1795.
1.5 Encapsulation products for use on industrial steel structures are not covered in this guide. Industrial steel structures include, but are not limited to, bridges, water towers, and tanks.
1.6 Limited documentation is available on evaluating the field performance of liquid coating encapsulation products. A conservative approach to assessing the selection and use of liquid coating encapsulation products is thus adopted in this guide. As appropriate, the guidance provided within will be revised as additional knowledge regarding how these products perform over time is gained.
1.7 The user of this guide should follow all regulations promulgated by authorities having jurisdiction regarding the use o...
- Guide9 pagesEnglish language
- Guide9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method provides a standard for comparison of rotating type anemometers, specifically cup anemometers and propeller anemometers, of different types. Specifications by regulatory agencies (4-7) and industrial societies have specified performance values. This standard provides an unambiguous method for measuring starting threshold, distance constant, transfer function, and off-axis response.
SCOPE
1.1 This test method covers the determination of the starting threshold, distance constant, transfer function, and off-axis response of a cup anemometer or propeller anemometer from direct measurement in a wind tunnel.
1.2 This test method provides for a measurement of cup anemometer or propeller anemometer performance in the environment of wind tunnel airflow. Transference of values determined by these methods to atmospheric flow must be done with an understanding that there is a difference between the two flow systems.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Waste samples collected using this practice provide representative samples for analysis in a laboratory using the TCLP.
5.2 The TCLP is used to simulate the transfer of lead from buried lead-containing waste into the ground water system upon codisposal of the lead-containing waste and municipal solid waste in unlined solid-waste landfills. The TCLP attempts to simulate rain or ground water leaching, or both. For the procedure to yield a predictor of the subsurface (in-ground) leaching process, a representative sample of the volume of the waste must be selected and submitted for leaching and analysis. The result of the sampling, leaching, and analysis process is used to determine the waste handling and disposal protocols to be followed and to document compliance with applicable laws, regulations, and requirements. This practice addresses the sampling process by defining a component-volume-based method to collect and assemble a representative sample of a solid waste stream that may contain heterogeneous components.
5.3 The collection of a volume-based sample of the waste stream is based on the fact that the TCLP leachate lead concentration limit, like other such TCLP limits, was developed based on the spatial dimensions of landfills.
5.4 Individuals who use this practice are expected to be trained in the proper and safe conduct of sampling of lead-containing wastes, qualified/certified/licensed as required by those authorities having jurisdiction over such activities, and properly utilize tools and safety equipment when conducting these procedures.
5.5 This practice may involve use of various hand and power tools for sampling the components of the waste. It is intended that such tools should be properly and safely used by persons trained and familiar with their performance and use.
5.6 In general terms, building components are drilled, sawed, snipped, etc., to collect samples of the various components in proportion to the volume of those components ...
SCOPE
1.1 This practice describes a method for selecting samples of building components coated with paints suspected of containing lead. The samples are collected from the debris waste stream created during demolition, renovation, lead hazard control, abatement, or other projects. The samples are subsequently analyzed by a laboratory for lead.
1.1.1 The debris waste stream is assumed to have more than one painted component, for example, metal doors, wood doors, and wood window trim.
1.2 This practice is intended for use when sampling to test for lead only and does not include sampling considerations for other metals or for organic compounds. This practice also does not include consideration of sampling for determination of other possible hazardous characteristics of the waste.
1.3 This practice assumes that the individual component types comprising the debris waste stream are at least partially segregated and that the volume of each type of component in the debris waste stream may be estimated.
1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This practice is intended to help reduce risks associated with lead hazards in buildings by providing standardized requirements for preserving records, findings, and recommendations associated with lead hazard activities.
4.2 This practice is intended for use by individuals and organizations that develop and have need to preserve objective evidence when contracting for or when conducting lead hazard activities themselves.
4.2.1 This practice is intended to assist in complying with management system requirements for record keeping promulgated by authorities having jurisdiction regarding conduct of lead hazard activities.
SCOPE
1.1 This practice describes requirements for preservation of records generated during lead hazard activities.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is intended for use with other standards that address the collection and preparation of samples (airborne particulate, dusts by wipe and micro-vacuuming, dried paint chips, and soils) that are obtained during the assessment or mitigation of lead hazards from buildings and related structures.
5.2 Laboratories analyzing samples obtained during the assessment or mitigation of lead hazards from buildings and related structures shall conform to Practice E1583, or shall be recognized for lead analysis as promulgated by authorities having jurisdiction, or both.
Note 2: In the United States of America, laboratories performing analysis of samples collected during lead-based paint activities are required to be accredited to ISO/IEC 17025 and to other requirements promulgated by the Environmental Protection Agency (EPA).
5.3 This test method may also be used to analyze similar samples from other environments such as toxic characteristic extracts of waste sampled using Guide E1908, and soil and sludge as prepared for analysis using U.S. EPA SW-846 Test Method 1311.
SCOPE
1.1 This test method covers the determination of lead (Pb) in airborne particulate, dust by wipe and micro-vacuuming, paint, and soil collected in and around buildings and related structures by flame atomic absorption spectrophotometry (FAAS) and is derived from Test Methods D4185 and E1613.
1.2 The sensitivity, detection limit, and optimum working concentration for lead (Pb) are given in Table 1.
1.3 The values stated in SI units are to be regarded as standard. No other values of measurement are included in this standard.
1.3.1 Exception—The SI and inch-pound units shown for wipe and micro-vacuuming sampling data are to be individually regarded as standard for wipe and micro-vacuuming sampling data (14.4.2 and 14.4.3).
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
- Standard9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The Hi-Vol sampler is commonly used for the collection of the airborne particulate component of the atmosphere. Some physical and chemical parameters of the collected particulate matter are dependent upon the physical characteristics of the collection system and the choice of filter media. A variety of options available for the Hi-Vol sampler give it broad versatility and allow the user to develop information about the size and quantity of airborne particulate material and, using subsequent chemical analytical techniques, information about the chemical properties of the particulate matter.
5.2 This test method presents techniques that when uniformly applied, provide measurements suitable for intersite comparisons.
5.3 This test method measures the atmosphere presented to the sampler with good precision, but the actual dust levels in the atmosphere can vary widely from one location to another. This means that sampler location may be of paramount importance, and may impose far greater variability of results than any lack of precision in the method of measurement. In particular, localized dust sources may exert a major influence over a very limited area immediately adjacent to such sources. Examples include unpaved streets, vehicle traffic on roadways with a surface film of dust, building demolition and construction activity, or nearby industrial plants with dust emissions. In some cases, dust levels measured close to such sources may be several times the community wide levels exclusive of such localized effects (see Practice D1357).
SCOPE
1.1 This test method provides for sampling a large volume of atmosphere, 1600 m3 to 2400 m3 (55 000 ft3 to 85 000 ft3), by means of a high flow-rate vacuum pump at a rate of 1.13 m3/min to 1.70 m3/min (40 ft3/min to 60 ft3/min) (1-4).2
1.2 This flow rate allows suspended particles having diameters of less than 100 μm (stokes equivalent diameter) to be collected. However, the collection efficiencies for particles larger than 20 μm decreases with increasing particle size and it varies widely with the angle of the wind with respect to the roof ridge of the sampler shelter and with increasing speed (5). When glass fiber filters are used, particles within the size range of 100 μm to 0.1 μm diameters or less are ordinarily collected.
1.3 The upper limit of mass loading will be determined by plugging of the filter medium with sample material, which causes a significant decrease in flow rate (see 6.4). For very dusty atmospheres, shorter sampling periods will be necessary. The minimum amount of particulate matter detectable by this method is 3 mg (95 % confidence level). When the sampler is operated at an average flow rate of 1.70 m3/min (60 ft3/min) for 24 h, this is equivalent to 1 μg/m3 to 2 μg/m3 (3).
1.4 The sample that is collected may be subjected to further analyses by a variety of methods for specific constituents.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard10 pagesEnglish language
SIGNIFICANCE AND USE
6.1 A primary use intended for this practice is for qualifying ASTM International Standards as Standard Test Methods. In the past, a “Precision and Bias” report has been required. However, recently a statement of uncertainty has become an acceptable alternative to Guide D3670. Inclusion of such a statement with a method description simplifies comparison of ASTM Test Methods to analogous ISO and Committee for European Normalization (CEN) standards, now required to have uncertainty statements.
6.2 Standardizing the characterization of sampling/analytical method performance is expected to be useful in other applications as well. For example, performance details are a necessity for justifying compliance decisions based on experimental air quality assessments (7). Documented uncertainty can form a basis for specific criteria defining acceptable sampling/analytical method performance.
6.3 Furthermore, high quality atmospheric measurements are vital for making decisions as to how hazardous substances are to be controlled. Valid data are required for drawing reasonable epidemiological conclusions, for making sound decisions as to acceptable limits, as well as for determining the efficacy of a hazard control system.
6.4 Finally, because of developing world-wide acceptance of ISO GUM for detailing measurements when statistics are simple, the practice should be useful in comparing ASTM International Test Methods to other published methods. The codification of statistical procedures may in fact minimize the difficulty in interpreting a plethora of individual, albeit possibly valid, approaches.
SCOPE
1.1 This practice is for assisting developers and users of air quality methods for sampling concentrations of both airborne and settled materials in characterizing measurements as to uncertainty. Where possible, analysis into uncertainty components as recommended in the International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement (ISO GUM, (1)2) is suggested. Aspects of uncertainty estimation particular to air quality measurement are emphasized. For example, air quality assessment is often complicated by: the difficulty of taking replicate measurements owing to the large spatio-temporal variation in concentration values to be measured; systematic error or bias, both corrected and uncorrected; and the (rare) non-normal distribution of errors. This practice operates mainly through example. Background and mathematical development are relegated to appendices for optional reading.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard14 pagesEnglish language
- Standard14 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is applicable to the measurement of airborne asbestos in a wide range of ambient air situations and for detailed evaluation of any atmosphere for asbestos structures. Most fibers in ambient atmospheres are not asbestos, and therefore, there is a requirement for fibers to be identified. Most of the airborne asbestos fibers in ambient atmospheres have diameters below the resolution limit of the light microscope. This test method is based on transmission electron microscopy, which has adequate resolution to allow detection of small thin fibers and is currently the only technique capable of unequivocal identification of the majority of individual fibers of asbestos. Asbestos is often found, not as single fibers, but as very complex, aggregated structures, which may or may not also be aggregated with other particles. The fibers found suspended in an ambient atmosphere can often be identified unequivocally if sufficient measurement effort is expended. However, if each fiber were to be identified in this way, the analysis would become prohibitively expensive. Because of instrumental deficiencies or because of the nature of the particulate matter, some fibers cannot be positively identified as asbestos even though the measurements all indicate that they could be asbestos. Therefore, subjective factors contribute to this measurement, and consequently, a very precise definition of the procedure for identification and enumeration of asbestos fibers is required. The method defined in this test method is designed to provide a description of the nature, numerical concentration, and sizes of asbestos-containing particles found in an air sample. The test method is necessarily complex because the structures observed are frequently very complex. The method of data recording specified in the test method is designed to allow reevaluation of the structure-counting data as new applications for measurements are developed. All of the feasible specimen preparation techn...
SCOPE
1.1 This test method2 is an analytical procedure using transmission electron microscopy (TEM) for the determination of the concentration of asbestos structures in ambient atmospheres and includes measurement of the dimension of structures and of the asbestos fibers found in the structures from which aspect ratios are calculated.
1.1.1 This test method allows determination of the type(s) of asbestos fibers present.
1.1.2 This test method cannot always discriminate between individual fibers of the asbestos and non-asbestos analogues of the same amphibole mineral.
1.2 This test method is suitable for determination of asbestos in both ambient (outdoor) and building atmospheres.
1.2.1 This test method is defined for polycarbonate capillary-pore filters or cellulose ester (either mixed esters of cellulose or cellulose nitrate) filters through which a known volume of air has been drawn and for blank filters.
1.3 The upper range of concentrations that can be determined by this test method is 7000 s/mm2. The air concentration represented by this value is a function of the volume of air sampled.
1.3.1 There is no lower limit to the dimensions of asbestos fibers that can be detected. In practice, microscopists vary in their ability to detect very small asbestos fibers. Therefore, a minimum length of 0.5 μm has been defined as the shortest fiber to be incorporated in the reported results.
1.4 The direct analytical method cannot be used if the general particulate matter loading of the sample collection filter as analyzed exceeds approximately 10 % coverage of the collection filter by particulate matter.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropri...
- Standard33 pagesEnglish language
- Standard33 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is applicable to the measurement of airborne carbon nanotubes in a wide range of ambient air situations and for evaluation of any atmosphere for carbon nanotube structures. Single carbon nanotube structures in ambient atmospheres have diameters below the resolution limit of the light microscope. This test method is based on transmission electron microscopy, which has adequate resolution to allow detection of small thin single carbon nanotubes and is currently a reliable technique capable of unequivocal identification of the majority of nanotube structures. Carbon nanotubes are often found, not as single carbon nanotubes, but as very complex, aggregated structures, which may or may not be aggregated with other particles.
5.2 This test method applies to the analysis of a single filter and describes the precision attributable to measurements for a single filter. Multiple air samples are usually necessary to characterize airborne nanotube structure concentrations across time and space. The number of samples necessary for this purpose is proportional to the variation in measurement across samples, which may be greater than the variation in measurement for a single sample.
SCOPE
1.1 This test method is an analytical procedure using transmission electron microscopy (TEM) for the determination of the concentration of carbon nanotubes and carbon nanotube-containing particles in ambient atmospheres.
1.1.1 This test method is suitable for determination of carbon nanotubes in both ambient (outdoor) and building atmospheres.
1.2 This test method is defined for polycarbonate capillary pore filters through which a known volume of air has been drawn and for blank filters.
1.3 The direct analytical method cannot be used if the general particulate matter loading of the sample collection filter as analyzed exceeds approximately 25 % coverage of the collection filter by particulate matter.
1.4 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard19 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The health of workers in many industries is at risk through exposure by inhalation to toxic metals. Industrial hygienists and other public health professionals need to determine the effectiveness of measures taken to control workers' exposures, and this is generally achieved by making workplace air measurements. Exposure to some metal-containing particles has been demonstrated to cause dermatitis, skin ulcers, eye problems, chemical pneumonitis, and other physical disorders (16).3
5.2 FAAS is capable of quantitatively determining many metals in air samples at the levels required by federal, state, and local occupational health and air pollution regulations. The analysis results can be used for the assessment of workplace exposures to metals in workplace air. The suitability of FAAS for elemental analysis for exposure assessment purposes must be investigated prior to carrying out workplace air sampling, in consideration of relevant occupational exposure limit values (OELVs) for metals of concern.
SCOPE
1.1 This test method covers the collection, dissolution, and determination of trace metals in workplace atmospheres, by flame atomic absorption spectrophotometry (FAAS).
1.2 The estimated method detection limits and optimum working concentration ranges for 21 metals are given in Table 1.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Specific safety precautionary statements are given in Section 9.)
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice is recommended for use primarily for non-occupational exposure monitoring in domiciles, public access buildings, and offices.
5.2 The methods described in this practice have been successfully applied to measurement of pesticides and PCBs in outdoor air and for personal respiratory exposure monitoring.
5.3 A broad spectrum of pesticides are commonly used in and around the house and for insect control in public and commercial buildings. Other semivolatile organic chemicals, such as PCBs, are also often present in indoor air, particularly in large office buildings. This practice promotes needed precision and bias in the determination of many of these airborne chemicals.
SCOPE
1.1 This practice covers the sampling of air for a variety of common pesticides and polychlorinated biphenyls (PCBs) and provides guidance on the selection of appropriate analytical measurement methods. Other compounds such as polychlorinated dibenzodioxins/furans, polybrominated biphenyls, polybrominated diphenyl ethers, polycyclic aromatic hydrocarbons, and polychlorinated naphthalenes may be efficiently collected from air by this practice, but guidance on their analytical determination is not covered by this practice.
1.2 The sampling and analysis of PCBs in air can be more complicated than sampling PCBs in solid media (for example, soils, building materials) or liquids (for example, transformer fluids). PCBs in solid or liquid material are typically analyzed using Aroclor2 distillation groups in chromatograms. In contrast, recent research has shown that analysis of PCBs in air samples by GC-ECD has also been found to exhibit potential uncertainties due to changes in the PCB patterns, differences in responses in distillation groups, peak co-elutions and differences in response factors within a homolog group (1, 2).3 As such it is recommended that PCBs in air not be quantified using AroclorTM distillation groups. In addition, it is recommended that analysis of PCBs in air be done using GC-MS rather than GC-ECD. Any mention, to outdated practices for “Aroclor” and GC-ECD analysis of PCBs herein are retained solely for historical perspective.
1.3 A complete listing of pesticides and other semivolatile organic chemicals for which this practice has been tested is shown in Table 1.
1.4 This practice is based on the collection of chemicals from air onto polyurethane foam (PUF) or a combination of PUF and granular sorbent (for example, diphenyl oxide, styrene-divinylbenzene), or a granular sorbent alone.
1.5 This practice is applicable to multicomponent atmospheres, 0.001 μg/m3 to 50 μg/m3 concentrations, and 4 h to 24 h sampling periods. The limit of detection will depend on the nature of the analyte and the length of the sampling period.
1.6 The analytical method(s) recommended will depend on the specific chemical(s) sought, the concentration level, and the degree of specificity required.
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see 10.24 and A1.1.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard16 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Studies of indoor air problems are often iterative in nature. A thorough engineering evaluation of a building (1-4)3 is sometimes sufficient to identify likely causes of indoor air problems. When these investigations and subsequent remedial measures are not sufficient to solve a problem, more intensive investigations may be necessary.
5.2 This guide provides the basis for determining when probability sampling methods are needed to achieve statistically defensible inferences regarding the goals of a study of indoor air quality. The need for probability sampling methods in a study of indoor air quality depends on the specific objectives of the study. Such methods may be needed to select a sample of people to be asked questions, examined medically, or monitored for personal exposures. They may also be needed to select a sample of locations in space and time to be monitored for environmental contaminants.
5.3 This guide identifies several potential obstacles to proper implementation of probability sampling methods in studies of indoor air quality in buildings and presents procedures that overcome those obstacles or at least minimize their impact.
5.4 Although this guide specifically addresses sampling people or locations across time within a building, it also provides important guidance for studying populations of buildings. The guidance in this document is fully applicable to sampling locations to determine environmental quality or sampling people to determine environmental effects within each building in the sample selected from a larger population of buildings.
SCOPE
1.1 This guide covers criteria for determining when probability sampling methods should be used to select locations for placement of environmental monitoring equipment in a building or to select a sample of building occupants for questionnaire administration for a study of indoor air quality. Some of the basic probability sampling methods that are applicable for these types of studies are introduced.
1.2 Probability sampling refers to statistical sampling methods that select units for observation with known probabilities (including probabilities equal to one for a census) so that statistically defensible inferences are supported from the sample to the entire population of units that had a positive probability of being selected into the sample.
1.3 This guide describes those situations in which probability sampling methods are needed for a scientific study of the indoor air quality in a building. For those situations for which probability sampling methods are recommended, guidance is provided on how to implement probability sampling methods, including obstacles that may arise. Examples of their application are provided for selected situations. Because some indoor air quality investigations may require application of complex, multistage, survey sampling procedures and because this standard is a guide rather than a practice, the references in Appendix X1 are recommended for guidance on appropriate probability sampling methods, rather than including expositions of such methods in this guide.
1.4 This standard does not address non-probability sampling approaches. Non-probability sampling approaches may be needed, such as worst-case sampling, range finding sampling, and screening sampling as inputs to help guide and inform probability sampling methods.
1.5 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide9 pagesEnglish language
- Guide9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Guidance is provided on designing model evaluation performance procedures and on the difficulties that arise in statistical evaluation of model performance caused by the stochastic nature of dispersion in the atmosphere. It is recognized there are examples in the literature where, knowingly or unknowingly, models were evaluated on their ability to describe something which they were never intended to characterize. This guide is attempting to heighten awareness, and thereby, to reduce the number of “unknowing” comparisons. A goal of this guide is to stimulate development and testing of evaluation procedures that accommodate the effects of natural variability. A technique is illustrated to provide information from which subsequent evaluation and standardization can be derived.
SCOPE
1.1 This guide provides techniques that are useful for the comparison of modeled air concentrations with observed field data. Such comparisons provide a means for assessing a model's performance, for example, bias and precision or uncertainty, relative to other candidate models. Methodologies for such comparisons are yet evolving; hence, modifications will occur in the statistical tests and procedures and data analysis as work progresses in this area. Until the interested parties agree upon standard testing protocols, differences in approach will occur. This guide describes a framework, or philosophical context, within which one determines whether a model's performance is significantly different from other candidate models. It is suggested that the first step should be to determine which model's estimates are closest on average to the observations, and the second step would then test whether the differences seen in the performance of the other models are significantly different from the model chosen in the first step. An example procedure is provided in Appendix X1 to illustrate an existing approach for a particular evaluation goal. This example is not intended to inhibit alternative approaches or techniques that will produce equivalent or superior results. As discussed in Section 6, statistical evaluation of model performance is viewed as part of a larger process that collectively is referred to as model evaluation.
1.2 This guide has been designed with flexibility to allow expansion to address various characterizations of atmospheric dispersion, which might involve dose or concentration fluctuations, to allow development of application-specific evaluation schemes, and to allow use of various statistical comparison metrics. No assumptions are made regarding the manner in which the models characterize the dispersion.
1.3 The focus of this guide is on end results, that is, the accuracy of model predictions and the discernment of whether differences seen between models are significant, rather than operational details such as the ease of model implementation or the time required for model calculations to be performed.
1.4 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This guide cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This guide is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should it be applied without consideration of a project's many unique aspects. The word “Standard” in the title of this guide means only that the document has been approved through the ASTM consensus process.
1.5 This standard applies to gaussian plume models; it may not be applicable to non-point sources, heavy gas models from evaporation from pool (for example, liquid spills), as well as near-field receptors.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this guide...
- Guide18 pagesEnglish language
- Guide18 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice may be used to estimate the potential for human exposure to pesticide residues that may be dislodged from residential floor surfaces by dermal contact. The sampling device employed is designed to approximately replicate the pressure applied by a 9 kg child crawling or walking on the floor.
5.2 Laboratory tests and field studies have shown that the transfer coefficient of the sampling device for collection of dried pesticide residues from nylon plush carpets is two to three times higher than that of a dry hand (palm only) pressed ten times at 7300 Pa over the same area of carpet (2, 4, 5).
5.3 This practice has been found suitable for use on plush and level loop carpets and vinyl flooring (2, 3).
5.4 This practice does not describe procedures for evaluation of the safety of floor surfaces or the potential for human exposure to dislodgeable pesticide residues. It is the user's responsibility to evaluate the data collected by this practice and make such determinations in consideration of other available information.
SCOPE
1.1 This practice covers a procedure for collection of dislodgeable pesticide residues from indoor floor surfaces.
1.2 This practice and the sampling methodology described are applicable to bare floors or covered floor surfaces, for example, carpeting and vinyl flooring.
1.3 This practice and the sampling methodology described are applicable to all pesticides listed in Practice D4861 whether applied directly to the floor surface or transported there by migration within the room or tracked in from outdoors.
1.4 Floor surfaces for which this practice has been successfully applied include nylon plush carpeting, polypropylene level-loop carpeting, and vinyl flooring.
1.5 Sample analysis will be dependent upon the nature of the pesticides targeted and is beyond the scope of this practice; however, the analytical procedures discussed in Practice D4861 are applicable to this practice.
1.6 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice will characterize the distribution of wind with a maximum of utility and a minimum of archive space. Applications of wind data to the fields of air quality, wind engineering, wind energy, agriculture, oceanography, forecasting, aviation, climatology, severe storms, turbulence and diffusion, military, and electrical utilities are satisfied with this practice. When this practice is employed, archive data will be of value to any of these fields of application. The consensus reached for this practice includes representatives of instrument manufacturers which provides a practical acceptance of these theoretical principles used to characterize the wind.
SCOPE
1.1 This practice covers a method for characterizing surface wind speed, wind direction, peak one-minute speeds, peak three-second and peak one-minute speeds, and standard deviations of fluctuation about the means of speed and direction.
1.2 This practice may be used with other kinds of sensors if the response characteristics of the sensors, including their signal conditioners, are equivalent or faster and the measurement uncertainty of the system is equivalent or better than those specified below.
1.3 The characterization prescribed in this practice will provide information on wind acceptable for a wide variety of applications.
Note 1: This practice builds on a consensus reached by the attendees at a workshop sponsored by the Office of the Federal Coordinator for Meteorological Services and Supporting Research in Rockville, MD on Oct. 29–30, 1992.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Sonic anemometer/thermometers are used to measure turbulent components of the atmosphere except in confined areas and very close to the ground. These practices apply to the use of these instruments for field measurement of the wind, sonic temperature, and atmospheric turbulence components. The quasi-instantaneous velocity component measurements are averaged over user-selected sampling times to define mean along-axis wind components, mean wind speed and direction, and the variances or covariances, or both, of individual components or component combinations. Covariances are used for eddy correlation studies and for computation of boundary layer heat and momentum fluxes. The sonic anemometer/thermometer provides the data required to characterize the state of the turbulent atmospheric boundary layer.
5.2 The sonic anemometer/thermometer array shall have a sufficiently high structural rigidity and a sufficiently low coefficient of thermal expansion to maintain an internal alignment to within ±0.1°. System electronics must remain stable over its operating temperature range; the time counter oscillator instability must not exceed 0.01 % of frequency. Consult with the sensor manufacturer for an internal alignment verification procedure.
5.3 The calculations and transformations provided in these practices apply to orthogonal arrays. References are also provided for common types of non-orthogonal arrays.
SCOPE
1.1 These practices cover procedures for measuring one-, two-, or three-dimensional vector wind components and sonic temperature by means of commercially available sonic anemometer/thermometers that employ the inverse time measurement technique. These practices apply to the measurement of wind velocity components over horizontal terrain using instruments mounted on stationary towers. These practices also apply to speed of sound measurements that are converted to sonic temperatures but do not apply to the measurement of temperature using ancillary temperature devices.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
6.1 SPF insulation is applied and formed onsite, which creates unique challenges for measuring product emissions. This test method provides a way to measure post-application chemical emissions from SPF insulation.
6.2 This test method can be used to identify compounds that emit from SPF insulation products, and the emission factors may be used to compare emissions at the specified sampling times and test conditions.
6.3 Emission data may be used in product development, manufacturing quality control and comparison of field samples.
6.4 This test method is used to determine chemical emissions from freshly applied SPF insulation samples. The utility of this test method for investigation of odors in building scale environments has not been demonstrated at this time.
SCOPE
1.1 This test method is used to identify and to measure the emissions of volatile organic compounds (VOCs) emitted from samples of cured spray polyurethane foam (SPF) insulation using micro-scale environmental test chambers combined with specific air sampling and analytical methods for VOCs.
1.2 Specimens prepared from product samples are maintained at specified conditions of temperature, humidity, airflow rate, and elapsed time in micro-scale chambers that are described in Practice D7706. Air samples are collected periodically at the chamber exhaust at the flow rate of the micro-scale chambers.
1.2.1 Samples for formaldehyde and other low-molecular weight carbonyl compounds are collected on treated silica gel cartridges and are analyzed by high performance liquid chromatography (HPLC) as described in Test Method D5197 and ISO 16000-3.
1.2.2 Samples for other VOCs are collected on multi-sorbent samplers and are analyzed by thermal-desorption gas chromatography / mass spectrometry (TD-GC/MS) as described in U.S. EPA Compendium Method TO-17 and ISO 16000-6.
1.3 This test method is intended specifically for SPF insulation products. Compatible product types include two component, high pressure and two-component, low pressure formulations of open-cell and closed-cell SPF insulation.
1.4 VOCs that can be sampled and analyzed by this test method generally include organic blowing agents such as 1,1,1,3,3-pentafluoropropane, formaldehyde and other carbonyl compounds, residual solvents, and some amine catalysts. Emissions of some organic flame retardants can be measured after 24 h with this method, such as tris (chloroisopropyl) phosphate (TCPP).
1.5 This test method does not cover the sampling and analysis of methylene diphenyl diisocyanate (MDI) or other isocyanates.
1.6 Area-specific and mass-specific emission rates are quantified at the elapsed times and chamber conditions as specified in 13.2 and 13.3 of this test method.
1.7 This test method is used to identify emitted compounds and to estimate their emission factors at specific times. The emission factors are based on specified conditions, therefore, use of the data to predict emissions in other environments may not be appropriate and is beyond the scope of this test method. The results may not be representative of other test conditions or comparable with other test methods.
1.8 This test method is primarily intended for freshly applied, SPF insulation samples that are sprayed and packaged as described in Practice D7859. The measurement of emissions during spray application and within the first hour following application is outside of the scope of this test method.
1.9 This test method can also be used to measure the emissions from SPF insulation samples that are collected from building sites where the insulation has already been applied. Potential uses of such measurements include investigations of odor complaints after product application. However, the specific details of odor investigations and other indoor air quality (IAQ) investigations are outside of the scope of this test method.
1.10 The values stated in SI units are to be regarde...
- Standard14 pagesEnglish language
- Standard14 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method provides a standard for comparison of wind vanes of different types. Specifications by regulatory agencies and industrial societies (3-5) have stipulated performance values. This test method provides an unambiguous method for measuring starting threshold, delay distance, and overshoot ratio.
SCOPE
1.1 This test method covers the determination of the starting threshold, delay distance, and overshoot ratio of a wind vane from direct measurements in a wind tunnel. This test method is applicable only to wind vanes having measurable overshoot.
1.2 This test method provides for determination of the performance of a system consisting of a wind vane and its associated position-to-output transducer in wind tunnel flow. Use of values determined by this test method to describe performance in atmospheric flow of a wind direction measuring system incorporating the vane must be done with an understanding of the differences between the two systems and the two environments.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Sulfuric acid is used in the manufacture of fertilizer, explosives, dyestuffs, other acids, parchment paper, glue, lead acid batteries, textiles, etc., and in the pickling of metals.
5.2 This test method has been found to be satisfactory in the measurement of sulfuric acid for comparison with relevant occupational exposure limits.
Note 2: In some countries the occupational exposure limit value (OELV) for sulfuric acid is related to the thoracic aerosol fraction; in such cases it is recommended to use a sampler for the thoracic aerosol fraction (ISO 20581).6
SCOPE
1.1 This ion chromatographic test method describes the determination of sulfuric acid mist in air samples collected from workplace atmospheres on a mixed cellulose ester (MCE) filter.
Note 1: Other filter types such as quartz fiber, polytetrafluoroethylene (PTFE), and polyvinyl chloride (PVC) filters are also suitable.
1.2 The lower detection limit of this test method is 0.001 mg/sample or 0.017 mg/m3 of sulfuric acid (H2SO4) mist in 60 L of air sampled at 1 L/min.
1.3 This test method is subject to interference from soluble and partially soluble sulfate salts. Other sulfur-containing compounds can be oxidized to sulfate and also interfere.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 No detailed instrument operating instructions are provided because of differences among various makes and models of ion chromatography (IC) systems. Instead, the analyst shall follow the instructions provided by the manufacturer of the particular instrument, analytical column, and suppressors used.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 9.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice may be used to collect dust from carpeted or bare floor surfaces for gravimetric or chemical analysis. The collected sample is substantially unmodified by the sampling procedure.
5.2 This practice provides for a reproducible dust removal rate from level loop and plush carpets, as well as bare floors. It has the ability to achieve relatively constant removal efficiency at different loadings of floor dust.
5.3 This practice also provides for the efficient capture of semivolatile organic chemicals associated with the dust. The test system can be fitted with special canisters downstream of the cyclone for the capture of specific semivolatile organic chemicals that may volatilize from the dust particles during collection.
5.4 This practice does not describe procedures for evaluation of the safety of floor surfaces or the potential human exposure to floor dust. It is the user's responsibility to evaluate the data collected by this practice and make such determinations in the light of other available information.
5.5 This practice provides per-event dust chemical concentration and chemical loading. Advantages and trade-offs of different sampling approaches have been discussed (7).
5.6 This practice uses a removable, cleanable dropout jar that facilitates per-event sampling. Other per-event vacuum attachments are commercially available. These are not directly comparable with composite sampling done using whole vacuum cleaner bags.
SCOPE
1.1 This practice covers a procedure for the collection of a sample of dust from carpets and bare floors that can be analyzed for inorganic metals such as lead and organic compounds such as pesticides and other semi-volatile organic compounds (SVOCs).
1.2 This practice is applicable to a variety of carpeted and bare floor surfaces. It has been tested for level loop and plush pile carpets and bare wood floors, specifically. This practice is not applicable to elevated, non-floor surfaces.
1.3 This practice is not intended for the collection and evaluation of dust for the presence of asbestos fibers.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This practice describes use of a sampling device, the High-Volume Small Surface Sampler (HVS3). Other event-based sampling devices that use commercially available vacuum attachments are not in scope. Composite sampling using whole vacuum cleaner bags is not in scope. Other approaches for floor or non-floor surface sampling (Practices D6966, D6661, D7144) are not within the scope.
1.6 This practice only applies to the HVS3. Other dust sampling methods may or may not be directly comparable. Method evaluation for other dust sampling approaches is encouraged. This could be done by comparison with methods outlined in this standard practice for HVS3 or through independent evaluation using field spikes and certified reference materials.
1.7 This practice provides information on dust loading, chemical dust concentration, and chemical dust loading. Information on the type of floor, the floor surface area sampled, and amount of dust collected is required (see Fig. 2). Cleaning the vacuum attachments in between sampling events is also required (see Section 13).
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
- Standard9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Choice of method depends primarily on which equipment is available. Higher accuracy is possible with the gasometer. The accuracies of the methods of atmospheric analysis, for which the calibration procedure is intended, do not warrant the very highest possible accuracy in flow measurement.
SCOPE
1.1 This practice covers the calibration of variable-area flowmeters (rotameters) used to determine air sample volumes at or close to ambient conditions of pressure and temperature, in the analysis of atmospheres for pollutant content.
1.2 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
6.1 Manufacturers increasingly are being asked or required to demonstrate that vapor-phase emissions of chemicals of concern from their products under normal use conditions comply with various voluntary or regulatory acceptance criteria. This process typically requires manufacturers to have their products periodically tested for VOC emissions by independent laboratories using designated reference test methods (for example, Test Method D6007, ISO 16000-9, and ISO 16000-10). To ensure continuing compliance, manufacturers may opt to, or be required to, implement screening tests at the production level.
6.2 Reference methods for testing chemical emissions from products are rigorous and typically are too time-consuming and impractical for routine emission screening in a production environment.
6.3 Micro-scale chambers are unique in that their small size and operation at moderately elevated temperatures facilitate rapid equilibration and shortened testing times. Provided a sufficiently repeatable correlation with reference test results can be demonstrated, appropriate control levels can be established and micro-scale chamber data can be used to monitor product manufacturing for likely compliance with reference acceptance criteria. Enhanced turnaround time for results allows for more timely adjustment of parameters to maintain consistent production with respect to vapor-phase chemical emissions.
6.4 This practice can also be used to monitor the quality of raw materials for manufacturing processes.
6.5 The use of elevated temperatures additionally facilitates screening tests for emissions of semi-volatile VOCs (SVOCs) such as some phthalate esters and other plasticizers.
SCOPE
1.1 This practice describes a micro-scale chamber apparatus and associated procedures for rapidly screening materials and products for their vapor-phase emissions of volatile organic compounds (VOCs) including formaldehyde and other carbonyl compounds. It is intended to complement, not replace reference methods for measuring chemical emissions for example, small-scale chamber tests (Guide D5116) and emission cell tests (Practice D7143).
1.2 This practice is suitable for use in and outside of laboratories, in manufacturing sites and in field locations with access to electrical power.
1.3 Compatible material/product types that may be tested in the micro-scale chamber apparatus include rigid materials, dried or cured paints and coatings, compressible products, and small, irregularly-shaped components such as polymer beads.
1.4 This practice describes tests to correlate emission results obtained from the micro-scale chamber with results obtained from VOC emission reference methods (for example, Guide D5116, Test Method D6007, Practice D7143, and ISO 16000-9 and ISO 16000-10).
1.5 The micro-scale chamber apparatus operates at moderately elevated temperatures, 30 °C to 60 °C, to eliminate the need for cooling, to reduce test times, boost emission rates, and enhance analytical signals for routine emission screening, and to facilitate screening of semi-volatile VOC (SVOC) emissions such as emissions of some phthalate esters and other plasticizers.
1.6 Gas sample collection and chemical analysis are dependent upon the nature of the VOCs targeted and are beyond the scope of this practice. However, the procedures described in Test Method D7339, Practice D6196 and ISO 16000-6 for analysis of VOCs and in Test Method D5197 and ISO 16000-3 for analysis of formaldehyde and other carbonyl compounds are applicable to this practice.
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicabilit...
- Standard10 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice applies to response actions for all types of asbestos-containing materials, including surfacing materials, thermal systems insulation, and miscellaneous materials, whether friable or not, regardless of the quantities involved and the reason for conducting the response action.
5.1.1 Abatement for the purpose of removing asbestos-containing materials or encapsulating or enclosing them, regardless of the engineering controls and work practices used, requires performance of visual inspections as described in this practice.
5.1.2 Operations and maintenance (O&M) activities, such as removal, encapsulation, or enclosure of asbestos-containing materials incidental to repair or replacement of a component, clean-up of debris from a fiber release episode, or other preventive measures, require the performance of visual inspections as described in this practice. See Managing Asbestos in Place7 and Guidance Manual.
5.1.3 This practice applies to response actions performed under a contract from the building owner, as well as to work performed by the building owner's staff.
5.2 The specific objectives of the visual inspection process before, during, and at the conclusion of an asbestos abatement project are: to review the extent of asbestos-containing material (ACM) within the scope of work, to monitor performance of the work, and to verify if visible residue, dust or debris, or unremoved material are absent at the completion of removal and clean-up activities.
5.2.1 The visual inspection process is used to evaluate all four aspects of an asbestos abatement project as follows:
5.2.1.1 Extent of ACM within Scope of Work—The building survey which is intended to locate and quantify asbestos-containing materials is not properly called a “visual inspection” within the context of this practice. To define the extent of ACM involved, a building survey is a necessary prelude to the first step of the visual inspection process. The building survey, which ma...
SCOPE
1.1 This practice covers procedures for performing visual inspections of asbestos response actions to:
1.1.1 Establish the extent of the required work before it begins;
1.1.2 Determine the progress and quality of the work and evaluate the completeness of the response action; and
1.1.3 Evaluate the cleanliness of the work area prior to final air testing for clearance (if performed), and subsequent to dismantling of critical barriers.
1.2 This practice can be used on an abatement project, or for operations and maintenance (O&M) work, performed by the building owner's staff. It can also be used in conjunction with contract documents between the building owner and other parties involved in an abatement project.
Note 1: Standard contract documents (such as AIA and EJCDC documents) define contractual relationships and responsibilities for projects within the construction industry. Asbestos abatement projects differ from traditional construction projects in the manner of their design and execution, as well as in the type and level of oversight required to substantiate their successful completion. Non-traditional responsibilities are given to the building owner, project designer, and abatement contractor by this practice. Furthermore, responsibilities related to project oversight, inspections, and approvals are placed upon an additional non-traditional representative of the building owner; the project monitor, as defined by this practice. All parties are cautioned that the subject authorities and corresponding responsibilities be understood, mutually agreed upon, and correspondingly addressed with appropriate modifications, if necessary, to the contract documents for a specific project.
1.3 This practice provides the following information:
1.3.1 The objectives of the visual inspection process;
1.3.2 The responsibilities and qualifications of the individuals involved in the visual inspections;
1.3.3 The...
- Standard16 pagesEnglish language
- Standard16 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Most occupational exposure assessment methods require the use of personal sampling pumps to collect air samples at typical sampling flow rates, with sampling volumes specified by (a) particular procedure(s). The precision and bias of these methods are directly affected by the precision and bias of the pumps used in the measurement of the air volume(s) sampled.
SCOPE
1.1 This practice describes the setting and verification of flow rate for sampling pumps commonly used for monitoring personal airborne exposures in the workplace.
1.2 This practice includes procedures for using working standard flow meters that are traceable to national or international standards, as well as those that are not. Traceable standards are preferred.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Many regulators, industrial processes, and other stakeholders require determination of NMOC in atmospheres.
5.2 Accurate measurements of ambient NMOC concentrations are critical in devising air pollution control strategies and in assessing control effectiveness because NMOCs are primary precursors of atmospheric ozone and other oxidants (7, 8).
5.2.1 The NMOC concentrations typically found at urban sites may range up to 1 ppm C to 3 ppm C or higher. In order to determine transport of precursors into an area monitoring site, measurement of NMOC upwind of the site may be necessary. Rural NMOC concentrations originating from areas free from NMOC sources are likely to be less than a few tenths of 1 ppm C.
5.3 Conventional test methods based upon gas chromatography and qualitative and quantitative species evaluation are relatively time consuming, sometimes difficult and expensive in staff time and resources, and are not needed when only a measurement of NMOC is desired. The test method described requires only a simple, cryogenic pre-concentration procedure followed by direct detection with an FID. This test method provides a sensitive and accurate measurement of ambient total NMOC concentrations where speciated data are not required. Typical uses of this standard test method are as follows.
5.4 An application of the test method is the monitoring of the cleanliness of canisters.
5.5 Another use of the test method is the screening of canister samples prior to analysis.
5.6 Collection of ambient air samples in pressurized canisters provides the following advantages:
5.6.1 Convenient collection of integrated ambient samples over a specific time period,
5.6.2 Capability of remote sampling with subsequent central laboratory analysis,
5.6.3 Ability to ship and store samples, if necessary,
5.6.4 Unattended sample collection,
5.6.5 Analysis of samples from multiple sites with one analytical system,
5.6.6 Collection of replicate samples for ...
SCOPE
1.1 This test method2 presents a procedure for sampling and determination of non-methane organic compounds (NMOC) in ambient, indoor, or workplace atmospheres.
1.2 This test method describes the collection of integrated whole air samples in silanized or other passivated stainless steel canisters, and their subsequent laboratory analysis.
1.2.1 This test method describes a procedure for sampling in canisters at final pressures above atmospheric pressure (pressurized sampling).
1.3 This test method employs a cryogenic trapping procedure for concentration of the NMOC prior to analysis.
1.4 This test method describes the determination of the NMOC by the flame ionization detection (FID), without the use of gas chromatographic columns and other procedures necessary for species separation.
1.5 The range of this test method is from 20 ppb C to 10 000 ppb C (1, 2).3
1.6 This test method has a larger uncertainty for some halogenated or oxygenated hydrocarbons than for simple hydrocarbons or aromatic compounds. This is especially true if there are high concentrations of chlorocarbons or chlorofluorocarbons present.
1.7 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Techn...
- Standard14 pagesEnglish language
- Standard14 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Air permits from regulatory agencies often require measurements of opacity from stationary air pollution point sources in the outdoor ambient environment. Opacity has been visually measured by certified smoke readers in accordance with USEPA (USEPA Method 9). DCOT is also a method to determine plume opacity in the outdoor ambient environment.
5.2 The concept of DCOT was based on previous method development using Digital Still Cameras and field testing of those methods.7,8 The purpose of this standard is to set a minimum level of performance for products that use DCOT to determine plume opacity in ambient environments.
SCOPE
1.1 This test method describes the procedures to determine the opacity of a plume, using digital imagery and associated hardware and software. The aforementioned plume is caused by particulate matter emitted from a stationary point source in the outdoor ambient environment.
1.2 The opacity of emissions is determined by the application of a Digital Camera Opacity Technique (DCOT) that consists of a Digital Still Camera, Analysis Software, and the Output Function’s content to obtain and interpret digital images to determine and report plume opacity.
1.3 This method is suitable to determine the opacity of plumes from zero (0) percent to one hundred (100) percent.
1.4 Conditions that shall be considered when using this method to obtain the digital image of the plume include the plume’s background, the existence of condensed water in the plume, orientation of the Digital Still Camera to the plume and the sun (see Section 8).
1.5 This standard describes the procedures to certify the DCOT, hardware, software, and method to determine the opacity of the plumes.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard22 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The Federal Occupational Safety and Health Administration, in 29 CFR 1910, designates that certain gases and vapors must not be present in workplace atmospheres at concentrations above specific values.
5.2 This practice will provide a means for the determination of airborne concentrations of certain gases and vapors given in 29 CFR 1910.
5.3 A partial list of chemicals for which this practice is applicable is presented in Annex A1.
5.4 This practice also provides for the sampling of gaseous atmospheres to be used for process control or other purposes (2, 24-23).
5.5 Advantages of the Detector Tube Method:
5.5.1 As the detector tube method requires no chemical analyzers, external reagents, etc., advance preparations are not needed; detector tubes are always ready for use.
5.5.2 The detector tube method is well-suited for use at the work site because it is small, lightweight, and needs only a small sample volume to determine the concentration of gas or vapor in a sample.
5.5.3 The operating procedures are simple.
5.5.4 The results of measurements are available in just minutes, so fast action can be taken when needed.
5.5.5 Where no electrical power source is required, detector tubes can be used even when flammable gases are present.
5.5.6 Different types of detector tubes are available for different gases and measuring ranges, from 0.01 ppm to more than 10 %, depending on analyte and tube design, making the system flexible tor different sampling situations.
SCOPE
1.1 This practice covers the detection and measurement of concentrations of toxic gases or vapors using detector tubes (1, 2).2 A list of some of the gases and vapors that can be detected by this practice and their measurement ranges are provided in Annex A1. This list is given as a guide and should be considered neither absolute nor complete.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The object of this test method is to provide guidelines for the construction of a psychrometer and the techniques required for accurately measuring the humidity in the atmosphere. Only the essential features of the psychrometer are specified.
SCOPE
1.1 General:
1.1.1 This test method covers the determination of the humidity of atmospheric air by means of wet- and dry-bulb temperature readings.
1.1.2 This test method is applicable for meteorological measurements at the earth's surface, for the purpose of the testing of materials, and for the determination of the relative humidity of most standard atmospheres and test atmospheres.
1.1.3 This test method is also applicable when the temperature of the wet bulb only is required. In this case, the instrument comprises a wet-bulb thermometer only.
1.1.4 Relative humidity (RH) does not denote a unit. Uncertainties in the relative humidity are expressed in the form RH ± rh %, which means that the relative humidity is expected to lie in the range (RH − rh) % to (RH + rh) %, where RH is the observed relative humidity. All uncertainties are at the 95 % confidence level.
1.2 Method A—Psychrometer Ventilated by Aspiration:
1.2.1 This method incorporates the psychrometer ventilated by aspiration. The aspirated psychrometer is more accurate than the sling (whirling) psychrometer (see Method B), and it offers advantages in regard to the space which it requires, the possibility of using alternative types of thermometers (for example, electrical), easier shielding of thermometer bulbs from extraneous radiation, accidental breakage, and convenience.
1.2.2 This method is applicable within the ambient temperature range 5 °C to 80 °C, wet-bulb temperatures not lower than 1 °C, and restricted to ambient pressures not differing from standard atmospheric pressure by more than 30 %.
1.3 Method B—Psychrometer Ventilated by Whirling (Sling Psychrometer):
1.3.1 This method incorporates the psychrometer ventilated by whirling (sling psychrometer).
1.3.2 This method is applicable within the ambient temperature range 5 °C to 50 °C, wet-bulb temperatures not lower than 1 °C and restricted to ambient pressures not differing from standard atmospheric pressure by more than 30 %.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 Warning—Mercury has been designated by many regulatory agencies as a hazardous material that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Safety Data Sheet (SDS) for additional information. Users should be aware that selling mercury and/or mercury containing products into your state or country may be prohibited by law.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (For more specific safety precautionary statements, see 8.1 and 15.1.)
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard24 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The procedures presented in this test method are available, in part, in Test Methods D3685/D3685M, as well as the ASME Methods (PTC 19.10-1968, PTC 19.10-1981, and PTC 38-1980) given in 2.3 and Footnote 5,5 the 40 CFR Part 60 given in 2.4, and the publication given in Footnote 6.6
SCOPE
1.1 This test method describes measurement of the average velocity of a gas stream for the purpose of determining gas flow in a stack, duct, or flue. Although technically complex, it is generally considered the most accurate and often the only practical test method for taking velocity measurements.
1.2 This test method is suitable for measuring gas velocities above 3 m/s (10 ft/s).
1.3 This test method provides procedures for determining stack gas composition and moisture content.
1.4 The values stated in SI units are to be regarded as standard. The inch-pound units given in parentheses are for information only.
1.5 This test method is applicable to conditions where steady-state flow occurs, and for constant fluid conditions, where the direction of flow is normal to the face tube opening of the pitot tube employed in the method. The method cannot be used for direct measurement when cyclonic or swirling flow conditions are present.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This guide presents options for a systematic assessment of fungal growth in buildings.
5.2 This guide allows for site-specific flexibility and professional judgment in the choice of assessment procedures. It may not be necessary to perform in its entirety the basic assessment presented below to resolve a particular problem, for example, where fungal growth is localized and the source and extent of moisture is readily observable.
5.3 Conversely, no matter how comprehensive the survey, all fungal growth may not be identified or located in a fungal assessment.
5.4 Material removal or destructive investigation may be needed to access suspect surfaces.
5.5 Using the procedures described in this guide, the investigator may have obtained the data necessary to suggest specific recommendations, for example, how to remediate the observed fungal growth, or how to prevent further fungal growth, but those recommendations are beyond the scope of this guide.
5.6 Precautions may be needed to protect the assessor and building occupants where access may disturb fungal growth.
5.7 It is the user’s responsibility to protect information that may be considered confidential, or private, or both, in accordance with project contract, corporate protocol, or local, state, and federal regulations, or a combination thereof.
5.8 It may be necessary to enlist other disciplines or trade expertise to assist in some steps of the assessment, but recommendations of when to enlist and whom to enlist are beyond the scope of this guide.
SCOPE
1.1 This guide provides a compendium of information and a menu of options for assessment of fungal growth in buildings, but does not recommend a specific course of action. Due to the wide variety of fungal problems affecting buildings and their occupants, and the wide variety of buildings, it is not possible to describe a set of uniform steps that will always be performed during an assessment (that is, a standard practice); therefore the user of this guide must decide which steps are appropriate for a given situation or building.
1.2 This guide is specific to fungal growth, which is only one potential problem in a building environment. It may be part of, but is not intended to take the place of, a comprehensive indoor air quality investigation.
1.3 This guide describes minimum steps and procedures for collecting background information on a building in question, procedures for evaluating the potential for moisture infiltration or collection, procedures for inspection for suspect fungal growth, and procedures beyond the scope of a basic survey that may be useful for specific problems.
1.4 Assessments for fungal growth may be useful wherever fungal growth is suspected, excess moisture has been present or when there are concerns regarding potential fungal growth.
1.5 Periodic fungal assessment in buildings may be a component of preventative maintenance programs.
1.6 This guide is applicable to buildings including residential (for example, single or multi-family), institutional (for example, schools, hospitals), government, public assembly, commercial (for example, office, retail), and industrial facilities.
1.7 Recommendations for developing a sampling strategy or methods for the collection and analysis of fungal samples are beyond the scope of this guide. For recommendations for developing a sampling strategy, see Ref (1)2, Chapter 10.
1.8 Recommendations for remediation of fungal growth are beyond the scope of this guide.
1.9 This guide is not intended to supersede any government regulations governing the assessment of fungal growth in buildings.
1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use...
- Guide9 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The static chambers have several different applications:
4.1.1 The static chambers can be used to compare the susceptibility of different materials to the colonization and amplification of various microorganisms under defined conditions.
4.1.2 Chambers operated at high relative humidities may be used to perform worst case scenario screening tests on materials by providing an atmosphere where environmental conditions may be favorable for microbial growth.
4.1.3 Use of multiple chambers with different environmental parameters, such as a range of relative humidities, permits the evaluation of multiple microenvironments and allows investigation of materials under differing environmental conditions.
4.1.4 Drying requirements for wetted materials may also be investigated. This information may be relevant for determining material resistance to microbial growth after becoming wet. These conditions may simulate those where materials are subjected to water incursion through leaks as well as during remediation of a building after a fire.
4.1.5 Growth rates of microorganisms on the material may also be investigated. Once it has been established that organisms are able to grow on a particular material under defined conditions, investigations into the rate of organism growth may be performed. These evaluations provide base line information and can be used to evaluate methods to limit or contain amplification of microorganisms.
4.2 These techniques should be performed by personnel with training in microbiology. The individual must be competent in the use of sterile technique, which is critical to exclude external contamination of materials.
SCOPE
1.1 Many different types of microorganisms (for example, bacteria, fungi, viruses, algae) can occupy indoor spaces. Materials that support microbial growth are potential indoor sources of biocontaminants (for example, spores and toxins) that can become airborne indoor biopollutants. This guide describes a simple, relatively cost effective approach to evaluating the ability of a variety of materials to support microbial growth using a small chamber method.
1.2 This guide is intended to assist groups in the development of specific test methods for a definite material or groups of materials.
1.3 Static chambers have certain limitations. Usually, only small samples of indoor materials can be evaluated. Care must be taken that these samples are representative of the materials being tested so that a true evaluation of the material is performed.
1.4 Static chambers provide controlled laboratory microenvironment conditions. These chambers are not intended to duplicate room conditions, and care must be taken when interpreting the results. Static chambers are not a substitute for dynamic chambers or field studies.
1.5 A variety of microorganisms, specifically bacteria and fungi, can be evaluated using these chambers. This guide is not intended to provide human health effect data. However, organisms of clinical interest, such as those described as potentially allergenic, may be studied using this approach.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide6 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice provides data needed for selection of instrument systems to measure meteorological quantities and to provide an estimate of the precision of measurements made by such systems.
5.2 This practice is based on the assumption that the repeated measurement of a meteorological quantity by a sensor system will vary randomly about the true value plus an unknowable systematic difference. Given infinite resolution, these measurements will have a Gaussian distribution about the systematic difference as defined by the Central Limit Theorem. If it is known or demonstrated that this assumption is invalid for a particular quantity, conclusions based on the characteristics of a normal distribution must be avoided.
SCOPE
1.1 Sensor systems used for making meteorological measurements may be tested for laboratory accuracy in environmental chambers or wind tunnels, but natural exposure cannot be fully simulated. Atmospheric quantities are continuously variable in time and space; therefore, repeated measurements of the same quantities as required by Practice E177 to determine precision are not possible. This practice provides standard procedures for exposure, data sampling, and processing to be used with two measuring systems in determining their operational comparability (1,2).2
1.2 The procedures provided produce measurement samples that can be used for statistical analysis. Comparability is defined in terms of specified statistical parameters. Other statistical parameters may be computed by methods described in other ASTM standards or statistics handbooks (3).
1.3 Where the two measuring systems are identical, that is, same make, model, and manufacturer, the operational comparability is called functional precision.
1.4 Meteorological determinations frequently require simultaneous measurements to establish the spatial distribution of atmospheric quantities or periodically repeated measurement to determine the time distribution, or both. In some cases, a number of identical systems may be used, but in others a mixture of instrument systems may be employed. The procedures described herein are used to determine the variability of like or unlike systems for making the same measurement.
1.5 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (See 8.1 for more specific safety precautionary information.)
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This practice is intended for the collection of airborne fungal spores or fragments, or both, using inertial impaction.
4.2 It is the responsibility of the user to assure that they are in compliance with all local, state and federal regulations governing the inspection of buildings for fungal colonization and the collection of associated samples.
4.3 This practice is intended to provide the user with a basic understanding of the equipment, materials and instructions necessary to effectively collect air samples using an inertial impactor.
4.4 This practice, when properly executed, may also be used for the evaluation of other types of airborne particles with the capturing characteristics appropriate for inertial impactor, and for which appropriate analytical methods exist. Such particles may include dust mites, skin cells, pollen, and other materials.
SCOPE
1.1 The purpose of this practice is to describe procedures for the collection of airborne fungal spores or fragments, or both, using inertial impaction sampling techniques.
1.2 This practice is not intended to limit the user from the collection of other airborne particulates that may be of interest and captured through this technique.
1.3 This practice presumes that the user has a fundamental understanding of field investigative techniques related to the scientific process, and sampling plan development and implementation. It is important to establish the related hypothesis to be tested and the supporting analytical methodology needed in order to identify the sampling media to be used and the laboratory conditions for analysis.
1.4 This practice does not address the development of a formal hypothesis or the establishment of appropriate and defensible investigation and sampling objectives. It is presumed the investigator has the experience and knowledge base to address these issues.
1.5 This practice does not provide the user sufficient information to allow for interpretation of the analytical results from sample collection. It is the user's responsibility to seek or obtain the information and knowledge necessary to interpret the sample results reported by the laboratory.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The method presented is a “short method” that may be used where contamination levels are less than 5000 ppm by weight or volume, temperatures are between 0 °C (32 °F) and 65 °C (150 °F), and the humidity is not considered. The gas is considered as standard air and the velocity is read directly from the instrument.
5.2 This test method is useful for determining air velocities in HVAC ducts, fume hoods, vent stacks of nuclear power stations, and in performing model studies of pollution control devices.
SCOPE
1.1 This test method describes the measurement of the average velocity with a thermal anemometer for the purpose of determining gas flow in a stack, duct, or flue (1-5).2 It is limited to those applications where the gas is essentially air at ambient conditions and the temperature, moisture, and contaminant loading are insignificant as sources of error compared to the basic accuracy of the typical field situation.
1.2 The range of the test method is from 1 to 30 m/s (3 to 100 ft/s).
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice is recommended for use in measuring the concentration of VOCs in ambient, indoor, and workplace atmospheres. It may also be used for measuring emissions from materials in small or full scale environmental chambers for material emission testing or human exposure assessment.
5.2 Such measurements in ambient air are of importance because of the known role of VOCs as ozone precursors, and in some cases (for example, benzene), as toxic pollutants in their own right.
5.3 Such measurements in indoor air are of importance because of the association of VOCs with air quality problems in indoor environments, particularly in relation to sick building syndrome and emissions from building materials. Many volatile organic compounds have the potential to contribute to air quality problems in indoor environments and in some cases toxic VOCs may be present at such elevated concentrations in home or workplace atmospheres as to prompt serious concerns over human exposure and adverse health effects (5).
5.4 Such measurements in workplace air are of importance because of the known toxic effects of many such compounds.
Note 1: While workplace air monitoring has traditionally been carried out using disposable sorbent tubes, typically packed with charcoal and extracted using chemical desorption (solvent extraction) prior to GC analysis – for example following NIOSH and OSHA reference methods – routine thermal desorption (TD) technology was originally developed specifically for this application area. TD overcomes the inherent analyte dilution limitation of solvent extraction improving method detection limits by 2 or 3 orders of magnitude and making methods easier to automate. Relevant international standard methods include ISO 16017-1 and ISO 16017-2. For a detailed history of the development of analytical thermal desorption and a comparison with solvent extraction methods see Ref (6).
5.5 In order to protect the environment as a whole and human health in part...
SCOPE
1.1 This practice is intended to assist in the selection of sorbents and procedures for the sampling and analysis of ambient (1),2 indoor (2), and workplace (3, 4) atmospheres for a variety of common volatile organic compounds (VOCs). It may also be used for measuring emissions from materials in small or full scale environmental chambers or for human exposure assessment.
1.2 This practice is based on the sorption of VOCs from air onto selected sorbents or combinations of sorbents. Sampled air is either drawn through a tube containing one or a series of sorbents (pumped sampling) or allowed to diffuse, under controlled conditions, onto the sorbent surface at the sampling end of the tube (diffusive or passive sampling). The sorbed VOCs are subsequently recovered by thermal desorption and analyzed by capillary gas chromatography.
1.3 This practice applies to three basic types of samplers that are compatible with thermal desorption: (1) pumped sorbent tubes containing one or more sorbents; (2) axial passive (diffusive) samplers (typically of the same physical dimensions as standard pumped sorbent tubes and containing only one sorbent); and (3) radial passive (diffusive) samplers.
1.4 This practice recommends a number of sorbents that can be packed in sorbent tubes for use in the sampling of vapor-phase organic chemicals; including volatile and semi-volatile organic compounds which, generally speaking, boil in the range 0 °C to 400 °C (v.p. 15 kPa to 0.01 kPa at 25 °C).
1.5 This practice can be used for the measurement of airborne vapors of these organic compounds over a wide concentration range.
1.5.1 With pumped sampling, this practice can be used for the speciated measurement of airborne vapors of VOCs in a concentration range of approximately 0.1 μg/m3 to 1 g/m3, for individual organic compounds in 1 L to 10 L air samples. Quantitative measurements are possible when using validated procedures with appropri...
- Standard32 pagesEnglish language
- Standard32 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method covers the determination of respirable dust concentration in workplace atmospheres.
5.2 Variations of the test method are in world-wide use for determining compliance relative to occupational exposure levels.
5.3 The test method may be used to verify dust control measures.
5.4 The test method may also be applied in research into health effects of dust in an occupational setting.
SCOPE
1.1 This test method provides details for the determination of respirable dust concentration defined in terms of international convention in a range from 0.5 mg/m3 to 10 mg/m3 in workplace atmospheres, depending on sampling time. Specifics are given for sampling and analysis using any one of a number of commercially available cyclone samplers.
1.2 The limitations on the test method are a minimum weight of 0.1 mg of dust on the filter, and a maximum loading dependent on sampler type and time of sampling. The test method may be used at higher loadings if the flow rate can be maintained constant.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This test method contains notes that are explanatory and are not part of the mandatory requirements of the method.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Most analytical methods used in air pollutant measurements are comparative in nature and require calibration or standardization, or both, often with known blends of the gas of interest. Since many of the important air pollutants are reactive and unstable, it is difficult to store them as standard mixtures of known concentration for extended calibration purposes. An alternative is to prepare dynamically standard blends as required. This procedure is simplified if a constant source of the gas of interest can be provided. Permeation tubes provide this constant source, if properly calibrated and if maintained at constant temperature. Permeation tubes have been specified as reference calibration sources, for certain analytical procedures, by the Environmental Protection Agency (3).
SCOPE
1.1 This practice describes a means for using permeation tubes for dynamically calibrating instruments, analyzers, and analytical procedures used in measuring concentrations of gases or vapors in atmospheres (1, 2).2
1.2 Typical materials that may be sealed in permeation tubes include: sulfur dioxide, nitrogen dioxide, hydrogen sulfide, chlorine, ammonia, propane, and butane (1).
1.3 The values stated in SI units are to be regarded as standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
3.1 The purpose of this terminology standard is to help users understand and apply the large number of specialized terms used in connection with the management of lead hazards by providing a single, comprehensive, and consistent terminology.
3.1.1 This terminology standard includes some terms that may be encountered, but whose use is discouraged. They are included for clarification and in order to provide the user with preferred existing alternate terms.
3.1.2 Architectural terms for individual building components are included to promote consistency of usage and to help ensure that sampling locations are recorded with sufficient accuracy to allow independent confirmation of lead measurements, if necessary.
3.2 A discussion is attached to certain definitions to help make the definition clear or to show how the term and its definition are related to other terms.
3.3 Terms and definitions in this terminology standard are based upon laws, regulations, and practices in the United States of America.
3.3.1 Some of the definitions in this terminology standard are adopted verbatim or are adapted from definitions that are formally stated or implied in laws and regulations. They are not intended to replace the latter definitions. The user is responsible for understanding legal definitions and for ensuring that the legal obligations that are encompassed by them are fully satisfied.
3.3.2 Users in other countries should refer to applicable national, regional, and local laws, regulations, and practices.
SCOPE
1.1 This terminology standard covers definitions for the following:
1.1.1 Terms that are commonly used in the field of management of lead hazards in facilities;
1.1.2 Architectural terms, particularly those associated with older wood-frame buildings; and,
1.1.3 Specialized terms that may be encountered by users in reports and notices that are generated during lead hazard management activities.
1.2 This terminology standard is supplementary to Terminology E631.
1.3 Definitions adopted or derived from other documents include the following:
1.3.1 Some of the definitions in this terminology standard are adopted as exact copies from other sources. The source is briefly identified at the right margin following the definition and fully identified in Section 2.
1.3.2 Some of the definitions in this terminology standard are adapted from other sources. Changes in these definitions were made only to clarify the meaning, to incorporate related terms that also are defined in this terminology standard, or to ensure that the revised definition is consistent with those for related terms. The source is briefly identified with the words “adapted” at the right margin following the definition, and is fully identified in Section 2.
1.4 Terms within the definitions that are shown in boldface are defined in this terminology standard.
1.5 This terminology standard excludes the following:
1.5.1 Terms with a common dictionary meaning, except in cases where there is a specialized definition within the field of lead hazard management.
1.5.2 Terms that are used only in individual ASTM standards in which they are defined adequately, whether formally or by the context in which they appear.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard10 pagesEnglish language
- Standard10 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This technique is applicable to dry paint films and varnishes in a variety of forms including the intact dry paint film surface, a notched or other angular cut surface that exposes a cross section of all paint layers, a paint chip, and ground paint film.
5.2 The response of the spot test method varies depending on the extractability of lead from a coating matrix, which may differ depending on the test kit used, the coating type tested, and the type of lead pigment (3).
5.3 In some situations, metals and other chemical species interfere with the spot tests causing false negative or false positive results (see Section 8).
5.4 A spot test result may be used as a negative screen for the presence of lead in paints and varnishes provided the response of the test kit is sensitive to detecting lead reliably at a given predetermined level, for example, a regulatory action level (4).
5.5 This practice may be used in conjunction with quantitative and semi-quantitative analytical methods for lead such as anodic stripping voltammetry or spectroscopic laboratory analysis of paint chip samples, or portable X-ray fluorescence testing of in situ paint films.
5.6 Colorblind individuals (protanomalous viewers) who are deficient in viewing red colors may have difficulty in discerning the pink or red color of a positive rhodizonate test.
SCOPE
1.1 This practice covers the use of commercial spot test kits based on either sulfide or rhodizonate for the qualitative determination of the presence of lead in dry paint films.
1.2 This practice may also be used as a qualitative procedure for other dry coating films such as varnishes.
1.3 This practice provides a list of the advantages and limitations of chemical spot test kits based on sulfide and rhodizonate to allow the user to choose the appropriate spot test for a given circumstance.
1.4 This practice contains notes which are explanatory and not part of mandatory requirements.
1.5 Methods described in this practice may not meet or be allowed by requirements or regulations established by local authorities having jurisdiction. It is the responsibility of the user of this standard to comply with all such requirements and regulations.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Emissions of VOCs are typically controlled by internal mass-transfer limitations (for example, diffusion through the material), while emissions of SVOCs are typically controlled by external mass-transfer limitations (migration through the air immediately above the material). The emission of some chemicals may be controlled by both internal and external mass-transfer limitations. In addition, due to their lower vapor pressure, SVOCs generally adsorb to different media (chamber walls, building materials, particles, and other surfaces) at greater rates than VOCs. This sorption can increase the amount of time required to reach steady-state SVOC concentrations using conventional VOC emission test methods to months for a single test (2).
4.2 Thus, existing methods for characterizing emissions of VOCs may not be appropriate or practical to properly characterize emission rates of SVOCs for use in modeling SVOC concentrations in indoor environments. A mass-transfer framework is needed to accurately assess emission rates of SVOCs when predicting the SVOC indoor air concentrations in indoor environments. The SVOC mass-transfer framework includes SVOC emission characteristics and its partition to multimedia including sorption to indoor surfaces, airborne particles, and settled dust. Once the SVOC emission parameters and partitioning coefficients have been determined, these values can be used to modeling SVOC indoor concentrations.
SCOPE
1.1 This guide is intended to serve as a foundation for understanding when to use emission testing methods designed for volatile organic compounds (VOCs) to determine area-specific emission rates that are typically used in modeling indoor air VOC concentrations and when to use emission testing methods designed for semi-volatile organic compounds (SVOCs) to determine mass transfer emission parameters that are typically used to model indoor air, dust, and surface SVOC concentrations.
1.2 This guide discusses how organic chemicals are conventionally categorized with respect to volatility.
1.3 This guide presents a simplified mass-transfer model describing organic chemical emissions from a material to bulk air. The values of the model parameters are shown to be specific to material/chemical/chamber combinations.
1.4 This guide shows how to use a mass-transfer model to estimate whether diffusion of the chemical within the material or convective mass transfer of the chemical from the surface of the material to the overlying air limits chemical emissions from the material surface.
1.5 This guide describes the range of different chambers that are available for emission testing. The chambers are classified as either dynamic or static and either conventional or sandwich. The chambers are categorized as being optimal to determine either the area-specific emission rate or mass-transfer emission parameters.
1.6 This guide discusses the roles sorption and convective mass-transfer coefficients play in selecting the appropriate emission chamber and analysis method to accurately and efficiently characterize emissions from indoor materials for use in modeling indoor chemical concentrations.
1.7 This guide recommends when to choose an emission test method that is optimized to determine either the area-specific emission rate or mass-transfer emission parameters. For chemicals where the controlling mass-transfer process is unknown, the guide outlines a procedure to determine if the chemical emission is controlled by convective mass transfer of the chemical from the material.
1.8 This guide does not provide specific guidance for measuring emission parameters or conducting indoor exposure modeling.
1.9 Mechanisms controlling emissions from wet and dry materials and products are different. This guide considers the emission of chemicals from dry materials and products. Examples of functional uses of VOCs and SVOCs that this guide applies to include blowing agents, ...
- Guide11 pagesEnglish language
- Guide11 pagesEnglish language
Frequently Asked Questions
D22 is a Technical Committee within ASTM International. It is named "Air Quality" and is responsible for: The promotion of knowledge, the development of test methods, practices, guides, and terminology pertaining to sampling and analysis of atmospheres, interpretation of data, the standardization of recognized and practiced methods for measurement of atmospheric quality, and sponsoring of discussions among those active in the study of air quality. The work of the Committee will be coordinated with other ASTM Committees and other organizations having mutual interest. This committee has published 905 standards.
D22 develops ASTM standards in the area of Information technology. The scope of work includes: The promotion of knowledge, the development of test methods, practices, guides, and terminology pertaining to sampling and analysis of atmospheres, interpretation of data, the standardization of recognized and practiced methods for measurement of atmospheric quality, and sponsoring of discussions among those active in the study of air quality. The work of the Committee will be coordinated with other ASTM Committees and other organizations having mutual interest. Currently, there are 905 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.