IEC 63497:2026, which is a product standard, is intended to specify the EMC, performance and safety requirements of shunt-connected active correction devices (ACD) with rated system voltages not exceeding 1 000 V AC or 1 500 V DC. These devices can be either cord or permanently connected. They can be movable, stationary, or fixed devices. An ACD includes both a static VAR generator (SVG) and an active harmonic filter (AHF). The primary function of a shunt connected ACD is to do one or more of the following: - active harmonic filtering; - reactive power compensation; - unbalanced load compensation. Additional functions of a shunt-connected ACD, not addressed by this document, can be the following: - flicker compensation; - interharmonic component filtering. In case of hybrid devices, combining a passive harmonic filter and an ACD, this document covers only the active part. This document does not cover - active mitigation functions part of another device (variable speed drive, uninterruptible power supply, dynamic voltage restorer, etc.), - switched power capacitors, - switched inductors, - passive harmonic filters, - energy storage converters, and - series-connected active correction devices.

  • Draft
    48 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV.
The purpose of this Part 1 is to define the common aspects of the products included in the above scope.

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV.
This document applies to tensioning devices consisting of tension and suspension clamps, fittings and brackets designed to be used for installation of self-supporting ABC defined in HD 626 S2.
Tests described in this document are type tests.

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

Part 1:
This part of IEC 62818, which is a Technical Specification, establishes a system of fiber
reinforced composite core used as supporting member material in conductors for overhead lines
which may be used as the basis for specifications. This document is applicable to fiber
reinforced composite core, with polymeric matrix, used as supporting member material in
conductors for overhead lines.
This document gives guidance on:
– defining the common terms used for fiber reinforced composite core with polymeric matrix,
– prescribing common methods and recommendations to characterize the properties of fiber
reinforced composite core based on single or multi-wires with PMC (Polymeric Matrix
Composite) used as supporting member material in conductors,
– prescribing or recommending acceptance or failure criteria when applicable.
These tests, criteria and recommendations are intended to ensure a satisfactory use and quality
under normal operating and environmental conditions.
This document does not apply to compliance criteria which may be required but indicative
values could be given in Annexes for guidance.

  • Technical specification
    38 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV.
This document applies to connectors used for the electrical connection of ABC.
The connectors are designed to be installed where either the main and/or branch cable is ABC as defined by HD 626 S2.
Tests described in this document are type tests.

  • Standard
    46 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV.
This document applies to the connections described in EN 50483-4, including branch connectors, Insulation Piercing Connectors (IPC), pre-insulated lugs (terminals) and through pre-insulated connectors (sleeves).
Two classes of connectors are covered by this document:
-   Class A: These are connectors intended for electricity distribution or industrial networks in which they can be subjected to short-circuits of relatively high intensity and duration. As a consequence, Class A connectors will be suitable for the majority of applications.
-   Class B: These are connectors for networks in which overloads or short-circuits are rapidly cleared by the operation of protection devices.
Depending on their application, the connectors are subjected to heat cycles and short-circuit current tests.
Class A: the connectors are subjected to heat cycles and short-circuit current tests.
Class B: the connectors are subjected to heat cycles only.
The object of this document is to define the heating cycles test methods and requirements which apply to compression through connectors, insulation piercing connectors and all other type of connections for low voltage aerial bundled cables.

  • Standard
    31 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV.
This document applies to tensioning devices consisting of tension and suspension clamps, and tension and suspension assemblies used for the installation of ABC with either insulated or bare neutral messenger.
The tension and suspension clamps are designed to be installed on neutral conductors of ABC defined in HD 626 S2.
Tests described in this document are type tests.

  • Standard
    37 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV.
This document defines the environmental tests in particular the climatic and corrosion ageing tests. The objective of these tests is to predict the behaviour of ABC accessories when subjected to sun radiation, to weather conditions (humidity, spraying water, heat, cold) and pollution. EN 50483-1, EN 50483-2, EN 50483-3 and EN 50483-4 specify which type tests included in this part of the standard are needed.

  • Standard
    26 pages
    English language
    e-Library read for
    1 day

Part 2:
This part of IEC 62818, which is a Technical Specification, establishes a system of fiber
reinforced composite cores used as supporting member material in conductors for overhead
lines which may be used as the basis for specifications. This document is applicable to fiber
reinforced composite core, with a metallic matrix, used as supporting member material in
conductors for overhead lines.
This document gives guidance on:
– defining the common terms used for fiber reinforced composite cores with a metallic matrix,
– prescribing common methods and recommendations to characterize the properties of fiber
reinforced composite cores based on single or multi-wires, with MMC (Metallic Matrix
Composite) used as a supporting member material in conductors,
– prescribing or recommending acceptance or failure criteria when applicable.
These tests, criteria and recommendations are intended to ensure a satisfactory use and quality
under normal operating and environmental conditions.
This document does not prescribe performance or compliance criteria which may be required
but indicative values could be given in Annexes for guidance.

  • Technical specification
    34 pages
    English language
    e-Library read for
    1 day

IEC TS 63529:2026, which is a Technical Specification, is intended to inform and guide the harmonic design of the DC side of HVDC projects. It considers all aspects of AC current and voltage occurring on the DC circuit and also the interaction with adjacent systems.
The switching action in HVDC converters results in a wide spectrum of harmonics. These range from the fundamental frequency to the radio frequency range. Traditionally the specification of DC side harmonic performance has been limited to the frequency range of interest for induced audible noise on nearby telephone systems. Often a limit of 50th harmonic has been applied, corresponding to 2 500 Hz or 3 000 Hz on 50 Hz and 60 Hz systems respectively. Occasionally the range has been extended to 5 000 Hz. This frequency range has corresponded to the spectrum of characteristic harmonic generation from thyristor line commutated converters (LCC).
The introduction of HVDC voltage sourced converters (VSC) has meant that although the magnitude of DC side harmonic generation from these converters is generally lower, the generated spectrum of interest extends to higher frequencies.
The scope of this document therefore covers the frequency range up to approximately 5 000 Hz. Higher frequencies are mentioned only when relevant. The scope excludes the much higher frequency ranges appropriate to PLC communication and the radio interference spectra.

  • Technical specification
    270 pages
    English language
    sale 15% off

IEC TS 63222‑4:2026 specifies the requirements of the models, methods and procedures for harmonic analysis on the public electric power network. This document is applicable to harmonic analysis up to 40th harmonic at high, medium and low voltage of the public electric power network with nominal frequency of 50 Hz or 60 Hz.

  • Technical specification
    50 pages
    English language
    sale 15% off

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This document applies to the connections described in EN 50483-4, including branch connectors, Insulation Piercing Connectors (IPC), pre-insulated lugs (terminals) and through pre-insulated connectors (sleeves). Two classes of connectors are covered by this document: - Class A: These are connectors intended for electricity distribution or industrial networks in which they can be subjected to short-circuits of relatively high intensity and duration. As a consequence, Class A connectors will be suitable for the majority of applications. - Class B: These are connectors for networks in which overloads or short-circuits are rapidly cleared by the operation of protection devices. Depending on their application, the connectors are subjected to heat cycles and short-circuit current tests. Class A: the connectors are subjected to heat cycles and short-circuit current tests. Class B: the connectors are subjected to heat cycles only. The object of this document is to define the heating cycles test methods and requirements which apply to compression through connectors, insulation piercing connectors and all other type of connections for low voltage aerial bundled cables.

  • Standard
    31 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. The purpose of this Part 1 is to define the common aspects of the products included in the above scope.

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This document applies to tensioning devices consisting of tension and suspension clamps, and tension and suspension assemblies used for the installation of ABC with either insulated or bare neutral messenger. The tension and suspension clamps are designed to be installed on neutral conductors of ABC defined in HD 626 S2. Tests described in this document are type tests.

  • Standard
    37 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This document applies to connectors used for the electrical connection of ABC. The connectors are designed to be installed where either the main and/or branch cable is ABC as defined by HD 626 S2. Tests described in this document are type tests.

  • Standard
    46 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This document defines the environmental tests in particular the climatic and corrosion ageing tests. The objective of these tests is to predict the behaviour of ABC accessories when subjected to sun radiation, to weather conditions (humidity, spraying water, heat, cold) and pollution. EN 50483-1, EN 50483-2, EN 50483-3 and EN 50483-4 specify which type tests included in this part of the standard are needed.

  • Standard
    26 pages
    English language
    e-Library read for
    1 day

The EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This document applies to tensioning devices consisting of tension and suspension clamps, fittings and brackets designed to be used for installation of self-supporting ABC defined in HD 626 S2. Tests described in this document are type tests.

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

IEC 63497:2026, which is a product standard, is intended to specify the EMC, performance and safety requirements of shunt-connected active correction devices (ACD) with rated system voltages not exceeding 1 000 V AC or 1 500 V DC.
These devices can be either cord or permanently connected. They can be movable, stationary, or fixed devices.
An ACD includes both a static VAR generator (SVG) and an active harmonic filter (AHF).
The primary function of a shunt connected ACD is to do one or more of the following:
- active harmonic filtering;
- reactive power compensation;
- unbalanced load compensation.
Additional functions of a shunt-connected ACD, not addressed by this document, can be the following:
- flicker compensation;
- interharmonic component filtering.
In case of hybrid devices, combining a passive harmonic filter and an ACD, this document covers only the active part.
This document does not cover
- active mitigation functions part of another device (variable speed drive, uninterruptible power supply, dynamic voltage restorer, etc.),
- switched power capacitors,
- switched inductors,
- passive harmonic filters,
- energy storage converters, and
- series-connected active correction devices.

  • Standard
    89 pages
    English and French language
    sale 15% off
  • Standard
    89 pages
    English and French language
    sale 15% off

This part of IEC 60358 applies to:
Coupling capacitors and capacitor dividers, with rated voltage > 1 000 V, connected line to ground with the low-voltage terminal either permanently earthed or connected to devices, for applications listed hereunder and other similar uses.
This document serves as a basic standard for the coupling capacitors and capacitor dividers.The different parts of this standard series will present the supplementary specifications and tests, for example IEC 60358-2, IEC 60358-3 or IEC 60358-4.
Diagrams of coupling capacitor and capacitor divider to which this standard series applies are given in Figure A.1 and Figure A.2 (see Annex A).

  • Standard
    82 pages
    English language
    e-Library read for
    1 day

IEC 63409-3:2025 specifies test procedures for confirming the basic operational characteristics of power conversion equipment (PCE) for use in photovoltaic (PV) power systems with or without energy storage. The basic operational characteristics are the capability of the PCE before any limitations due to internal settings are applied to the PCE to meet specific grid support functions or specific behaviours against abnormal changes.
This document covers the testing of the following items:
a) Steady state characteristics
Test procedures to confirm operable range of PCE at steady state condition are described. The operable ranges in apparent power, active power, reactive power, power factor, grid voltage and grid frequency are confirmed according to the test procedures.
b) Transient-response characteristics
Test procedures to confirm PCE’s response against a change of operational condition are described.
This document only considers the changes within normal (continuous) operable ranges. Therefore, the behaviours against abnormal changes and grid support functions are out of the scope and are covered in other parts of this series.

  • Standard
    72 pages
    English language
    e-Library read for
    1 day

IEC 63563-5:2025 defines the low-level (physical layer and the data link layer) formats of data bits, data bytes, and data packets. In addition, it provides requirements and guidelines for load modulation and frequency-shift keying.

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

IEC 60358-1:2025 is available as IEC 60358-1:2025 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60358-1:2025 This part of IEC 60358 applies to: Coupling capacitors and capacitor dividers, with rated voltage > 1 000 V, connected line to ground with the low-voltage terminal either permanently earthed or connected to devices, for applications listed hereunder and other similar uses. This document serves as a basic standard for the coupling capacitors and capacitor dividers.

  • Standard
    82 pages
    English language
    e-Library read for
    1 day

IEC 63563-8:2025 provides guidelines for detecting the presence of a Radio Frequency Identification (RFID) tag or Near Field Communication (NFC) card within the operating range of the Power Transmitter and preventing damage to the tag or card.

  • Standard
    33 pages
    English language
    e-Library read for
    1 day

IEC 63563-3:2025 identifies basic physical design requirements and guidelines for Power Transmitter and Power Receiver Products, including product and system dimensions, alignment of the products, surface temperature rise, and indications to the user.

  • Standard
    19 pages
    English language
    e-Library read for
    1 day

IEC 63563-1:2025 introduces the Qi Specification, which applies to flat surface devices such as mobile phones and tablets that use up to 15 W of power

  • Standard
    20 pages
    English language
    e-Library read for
    1 day

IEC 63563-7:2025 defines methods for ensuring that the power transfer proceeds without heating metal objects in the magnetic field of a Power Transmitter. Although the Power Transmitter may optionally use any of these methods, some of them require assistance by the Power Receiver.

  • Standard
    54 pages
    English language
    e-Library read for
    1 day

IEC 62351-7:2025 defines network and system management (NSM) data object models that are specific to power system operations. These NSM data objects will be used to monitor the health of networks and systems, to detect possible security intrusions, and to manage the performance and reliability of the information infrastructure. The goal is to define a set of abstract objects that will allow the remote monitoring of the health and condition of IEDs (Intelligent Electronic Devices), RTUs (Remote Terminal Units), DERs (Distributed Energy Resources) systems and other systems that are important to power system operations.
Power systems operations are increasingly reliant on information infrastructures, including communication networks, IEDs, and self-defining communication protocols. Therefore, management of the information infrastructure has become crucial to providing the necessary high levels of security and reliability in power system operations.
The telecommunication infrastructure that is in use for the transport of telecontrol and automation protocols is already subject to health and condition monitoring control, using the concepts developed in the IETF Simple Network Management Protocol (SNMP) standards for network management. However, power system specific devices (like teleprotection, telecontrol, substation automation, synchrophasors, inverters and protections) need instead a specific solution for monitoring their health.
The NSM objects provide monitoring data for IEC protocols used for power systems (IEC 61850, IEC 60870-5-104) and device specific environmental and security status. As a derivative of IEC 60870-5-104, IEEE 1815 DNP3 is also included in the list of monitored protocols. The NSM data objects use the naming conventions developed for IEC 61850, expanded to address NSM issues. For the sake of generality these data objects, and the data types of which they are comprised, are defined as abstract models of data objects.
In addition to the abstract model, in order to allow the integration of the monitoring of power system devices within the NSM environment in this part of IEC 62351, a mapping of objects to the SNMP protocol of Management Information Base (MIBs) is provided.
The objects that are already covered by existing MIBs are not defined here but are expected to be compliant with existing MIB standards. For example protocols including EST, SCEP, RADIUS, LDAP, GDOI are not in scope.
This edition of IEC 62351-7 cancels and replaces IEC 62351-7 published in 2017. This new edition constitutes a technical revision and includes the following significant technical changes with respect to IEC 62351-7:
a) Reviewed and enriched the NSM object data model;
b) UML model adopted for NSM objects description;
c) SNMP protocol MIBs translation included as Code Components

  • Standard
    135 pages
    English language
    e-Library read for
    1 day

IEC 63563-6:2025 defines the messaging between a Power Transmitter and a Power Receiver. The primary purpose of this messaging is to set up and control the power transfer. As a secondary purpose, it provides a transport mechanism for higher-level applications such as Authentication. The communications protocol comprises both the required order and timing relations of successive messages.

  • Standard
    143 pages
    English language
    e-Library read for
    1 day

IEC 63563-2:2025 provides glossary of definitions, acronyms, and symbols for the the Qi Specification, which applies to flat surface devices such as mobile phones and tablets that use up to 15 W of power

  • Standard
    19 pages
    English language
    e-Library read for
    1 day

IEC 63563-11:2025 describes Magnetic power profile (MPP) which is a protocol extension that provides additional messages, new power states/modes, new power transfer contract elements, and aims to provide the following functionalities:
• Operating Frequency Negotiation
• Cloaking (Power Pause)
• Generic Information Exchange
• Simultaneous Data Stream Transactions
• Fast PTx to PRx communication
• Maximum Power and Power Control Profiles Determination
• Extended Power Negotiation
• Extended PTx/PRx Identification and Capabilities
• Extended Control Error Packets and Received Power Packets
• Power Transmitter Battery Level Reporting
• Ecosystem Scalability
MPP extension allows devices to operate under Restricted mode (no PTx communication) at 360kHz without performing any explicit negotiation with the Power Transmitter. This flexibility enables devices with limited resources (e.g., devices with no FSK support) to take advantage of the frequency change feature.

  • Standard
    110 pages
    English language
    e-Library read for
    1 day

IEC 63563-10:2025 defines MPP (Magnetic Power Profile), an extension to Qi v1.3 BPP (Baseline Power Profile). Manufacturers can use this specification to implement PTx and/or PRx that are interoperable.

  • Standard
    168 pages
    English language
    e-Library read for
    1 day

IEC 63563-9:2025 defines the architecture and application-level messaging for the Authentication of a Power Transmitter Product by a Power Receiver to ensure that the Power Transmitter Product is both Qi certified and the product of a registered manufacturer.

  • Standard
    95 pages
    English language
    e-Library read for
    1 day

IEC 63563-4:2025 comprises guidelines and requirements for Power Receiver design, including circuitry, power consumption, operating power levels, power transfer efficiency, and standby power.

  • Standard
    60 pages
    English language
    e-Library read for
    1 day

IEC TR 62786-100:2026 gives guidance for the drafting of IEC publications which relate, wholly or partly, to connection of distributed energy resources (DER) with the grid. Technical committees relevant to the connection of DER with grid are advised to follow the guidance given in this document when they prepare new publications and clauses relevant to the connection of DER with the grid, as well as when they revise existing publications so that consistent and harmonized standards can be delivered. Annex A, Annex B, Annex C, and Annex D list documents relevant to grid connection of DER in order to ensure that other IEC publications are consistent with these documents and to avoid overlapping each other.
Table E.1 lists national and regional standards and regulations relevant to connecting DER with the grid.

  • Technical report
    22 pages
    English language
    sale 15% off

Part 2: This part of IEC 62818, which is a Technical Specification, establishes a system of fiber reinforced composite cores used as supporting member material in conductors for overhead lines which may be used as the basis for specifications. This document is applicable to fiber reinforced composite core, with a metallic matrix, used as supporting member material in conductors for overhead lines. This document gives guidance on: – defining the common terms used for fiber reinforced composite cores with a metallic matrix, – prescribing common methods and recommendations to characterize the properties of fiber reinforced composite cores based on single or multi-wires, with MMC (Metallic Matrix Composite) used as a supporting member material in conductors, – prescribing or recommending acceptance or failure criteria when applicable. These tests, criteria and recommendations are intended to ensure a satisfactory use and quality under normal operating and environmental conditions. This document does not prescribe performance or compliance criteria which may be required but indicative values could be given in Annexes for guidance.

  • Technical specification
    34 pages
    English language
    e-Library read for
    1 day

Part 1: This part of IEC 62818, which is a Technical Specification, establishes a system of fiber reinforced composite core used as supporting member material in conductors for overhead lines which may be used as the basis for specifications. This document is applicable to fiber reinforced composite core, with polymeric matrix, used as supporting member material in conductors for overhead lines. This document gives guidance on: – defining the common terms used for fiber reinforced composite core with polymeric matrix, – prescribing common methods and recommendations to characterize the properties of fiber reinforced composite core based on single or multi-wires with PMC (Polymeric Matrix Composite) used as supporting member material in conductors, – prescribing or recommending acceptance or failure criteria when applicable. These tests, criteria and recommendations are intended to ensure a satisfactory use and quality under normal operating and environmental conditions. This document does not apply to compliance criteria which may be required but indicative values could be given in Annexes for guidance.

  • Technical specification
    38 pages
    English language
    e-Library read for
    1 day

The IEC 63382 series specifies the management of distributed energy storage systems, composed of electrically chargeable vehicle batteries (ECV-DESS), which are handled by an aggregator/flexibility operator (FO) to provide energy flexibility services to grid operators.
Aggregator and flexibility operator have the same meaning in the context of this document and represent the entity which aggregates a number of other network users (e.g. energy consumers, prosumers, DERs) bundling energy consumption or generation assets into manageable sizes for the energy system.
The aggregator/FO communicates with the charging station (CS) backend system, which is typically the system platform (HW, SW and HMI) of either a charging station operator (CSO), or a charging service provider (CSP).
The purpose of the data exchange is to perform flexibility services, and it takes place between the aggregator/FO and a dedicated interface located in the CS backend system, which has been defined FCSBE, flexibility port at the charging station backend.
This part of IEC 63382 describes the technical characteristics and architectures of ECV-DESS, including:
– EV charging stations configurations, comprising several AC-EVSEs and/or DC-EVSEs;
– individual EVs connected to grid via an EVSE and managed by an aggregator/FO.
The focus of this document is on the interface between the FO and the FCSBE and the data exchange at this interface, necessary to perform energy flexibility services (FS).
The FO/aggregator converts grid services and/or grid support functions requested by the grid operators (DSOs or TSOs) into multiple flexibility services to be provided by a number of CSs, utilizing their own optimization and resource allocation algorithms.
Communication between FO and grid operators (DSO, TSO), optimization algorithms adopted by FO, flexibility service bidding procedures are out of scope of this document.
The data exchange between FO and FCSBE typically includes:
– flexibility service request and response;
– flexibility services parameters;
– EV charging station configuration and technical capabilities;
– credentials check of parties involved in the flexibility service;
– FS execution related notifications;
– event log, detailed service record, proof of work.
The exchange of credentials has the purpose to identify, authenticate and authorize the actors involved in the flexibility service transaction, to check the validity of a FS contract and to verify the technical capabilities of the system EV + CS, and conformity to applicable technical standards to provide the requested flexibility service.
This document also describes the technical requirements of ECV-DESS, the use cases, the information exchange between the EV charging station operator (CSO) and the aggregator/FO, including both technical and business data.
It covers many aspects associated to the operation of ECV-DESS, including:
– privacy issues consequent to GDPR application (general data protection regulation);
– cybersecurity issues;
– grid code requirements, as set in national guidelines, to include ancillary services, mandatory functions and remunerated services;
– grid functions associated to V2G operation, including new services, as fast frequency response;
– authentication/authorization/transactions relative to charging sessions, including roaming, pricing and metering information;
– management of energy transfers and reporting, including information interchange, related to power/energy exchange, contractual data, metering data;
– demand response, as smart charging (V1G).
It makes a distinction between mandatory grid functions and market driven services, taking into account the functions which are embedded in the FW control of DER smart inverters.
This document deals with use cases, requirements and architectures of the ECV-DESSs with the associated EV charging stations.
Some classes of energy flexibility services (FS) have been identified and illustrated in dedic

  • Standard
    200 pages
    English language
    e-Library read for
    1 day

IEC TS 63042-301:2026, which is a technical specification, applies to on-site acceptance tests of electrical equipment with the highest voltages of AC transmission system exceeding 800 kV and its protection and control system.
The electrical equipment exceeding 800 kV includes the following items:
- power transformers;
- circuit-breakers;
- gas insulated switchgear (GIS);
- gas insulated transmission line (GIL);
- surge arresters;
- voltage and current transformers;
- shunt reactors;
- series compensators;
- insulators;
- disconnectors and earthing switches;
- high-speed earthing switches (HSES).
This second edition cancels and replaces the first edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) new subclause with measurement of short-circuit impedance and load loss for on-site assembly transformer has been added;
b) new subclause with measurement of no-load loss and current for on-site assembly transformer has been added;
c) on-site acceptance test requirement for GIL has been added;
d) new clause with protection and control system on-site acceptance tests has been added.

  • Technical specification
    34 pages
    English language
    sale 15% off
  • Technical specification
    71 pages
    English language
    sale 15% off

IEC 60743:2013 applies to the terminology used to describe tools, devices, equipment and methods used in live working. It standardizes the name of tools, devices and equipment and permits their identification by providing definitions and illustrations. It contains some example illustrations. This third edition cancels and replaces the second edition, published in 2001, and its Amendment 1:2008.This edition constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: the clause 2 has been simplified and refers directly to IEC 60050-651; some definitions have been moved to specific existing clauses. This new edition is complementary to IEC 60050-651. Different publications under the responsibility of TC 78 include terms and its definitions. IEC 60050-651 (IEV 651) provides precise, brief and correct definitions of internationally accepted concepts in the field of live working, and specifies the terms by which these defined concepts are known. Electropedia gives access to the terms and definitions of IEC 60050-651 (http://www.electropedia.org/). Each product standard gives definitions necessary for the understanding of certain terms used in a specific context. The IEC Glossary (http://std.iec.ch/glossary) gives on-line access to the information.

  • Standard
    128 pages
    English and French language
    sale 15% off
  • Standard
    260 pages
    English and French language
    sale 15% off

IEC TS 62786-42:2026 defines minimum requirements for AC voltage measurement used to control distributed energy resources (DER) and loads connected to distribution networks.
This document specifies the characteristics of voltage magnitude measurement to evaluate their performances (including voltage and frequency measuring range, accuracy, voltage and frequency operating range, resolution, etc).
This document describes the main use cases of voltage measurement, with associated level of performances.
This document describes the principle of functional tests to evaluate the specified characteristics and defines the influencing factors that affect these performances, under steady state or dynamic conditions.
This document defines the functional requirements applicable to voltage measurement which can be embedded inside DER or loads controller or performed as an external control system. In the case of DER, this document is a subpart of requirements which are defined in the other parts of the IEC 62786 series.
This document is applicable to DER and loads regardless of voltage level at the point of connection to the distribution grid.
This document does not specify hardware, software or a method for voltage measurement. It does not specify tests linked to environmental conditions associated to hardware devices (climatic, mechanical stress, electromagnetic compatibility test, etc).

  • Technical specification
    59 pages
    English language
    sale 15% off

IEC TS 63042-401:2026, which is a Technical Specification, gives guidance on UHV AC substation maintenance considering system-oriented maintenance issues of UHV AC transmission systems.
It is based on the development and on-site practice of maintenance technology involved in UHV AC transmission systems. It applies to power system planners, equipment suppliers, engineering contractors, maintenance staff and power grid operators.

  • Technical specification
    45 pages
    English language
    sale 15% off

IEC 61643-21:2025 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages.
These devices are intended to be connected to telecommunications and signalling networks, and equipment rated up to 1 000 V RMS and 1 500 V DC.
These telecommunications and signalling networks can also provide power on the same line, e.g. Power over Ethernet (PoE).
Performance and safety requirements, tests and ratings are specified in this document. These devices contain at least one voltage-limiting component (clamping or switching) and are intended to limit surge voltages and divert surge currents.
This second edition cancels and replaces the first edition published in 2000, Amendment1:2008 and Amendment 2:2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) New structure of IEC 61643-21 based on IEC 61643-01:2024;
b) Several safety requirements based on IEC 61643-01:2024 have been added.
This International Standard is to be used in conjunction with IEC 61643-01:2024.

  • Standard
    89 pages
    English language
    e-Library read for
    1 day

IEC 63382-1:2025 series specifies the management of distributed energy storage systems, composed of electrically chargeable vehicle batteries (ECV-DESS), which are handled by an aggregator/flexibility operator (FO) to provide energy flexibility services to grid operators. IEC 63382-1:2025 describes the technical characteristics and architectures of ECV-DESS, including: – EV charging stations configurations, comprising several AC-EVSEs and/or DC-EVSEs; – individual EVs connected to grid via an EVSE and managed by an aggregator/FO. The focus of this document is on the interface between the FO and the FCSBE and the data exchange at this interface, necessary to perform energy flexibility services (FS). The data exchange between FO and FCSBE typically includes: – flexibility service request and response; – flexibility services parameters; – EV charging station configuration and technical capabilities; – credentials check of parties involved in the flexibility service; – FS execution related notifications; – event log, detailed service record, proof of work. The exchange of credentials has the purpose to identify, authenticate and authorize the actors involved in the flexibility service transaction, to check the validity of a FS contract and to verify the technical capabilities of the system EV + CS, and conformity to applicable technical standards to provide the requested flexibility service. This document also describes the technical requirements of ECV-DESS, the use cases, the information exchange between the EV charging station operator (CSO) and the aggregator/FO, including both technical and business data. It covers many aspects associated to the operation of ECV-DESS, including: – privacy issues consequent to GDPR application (general data protection regulation); – cybersecurity issues; – grid code requirements, as set in national guidelines, to include ancillary services, mandatory functions and remunerated services; – grid functions associated to V2G operation, including new services, as fast frequency response; – authentication/authorization/transactions relative to charging sessions, including roaming, pricing and metering information; – management of energy transfers and reporting, including information interchange, related to power/energy exchange, contractual data, metering data; – demand response, as smart charging (V1G). It makes a distinction between mandatory grid functions and market driven services, taking into account the functions which are embedded in the FW control of DER smart inverters. This document deals with use cases, requirements and architectures of the ECV-DESSs with the associated EV charging stations. Some classes of energy flexibility services (FS) have been identified and illustrated in dedicated use cases: – following a dynamic setpoint from FO; – automatic execution of a droop curve provided by FO, according to local measurements of frequency, voltage and power; – demand response tasks, stimulated by price signals from FO; – fast frequency response. Furthermore, some other more specific flexibility service use cases include: – V2G for tertiary control with reserve market; – V2H with dynamic pricing linked to the wholesale market price; – distribution grid congestion by EV charging and discharging. FS are performed under flexibility service contracts (FSC) which can be stipulated

  • Standard
    200 pages
    English language
    e-Library read for
    1 day

IEC TR 63179:2026, which is a Technical Report, provides technical information for planning high-voltage direct current (HVDC) systems with line-commutated converters (LCC), voltage sourced converters (VSC), or both. It provides general principles for deciding between HVDC and AC transmission systems, as well as processes and methods for preliminarily defining the HVDC transmission scheme, including selection of converter type and key parameters, grid stability analysis, and technical-economic comparison among various solutions. In addition, this document gives the objectives to be achieved in the planning phase.
This document is applicable for planning a point-to-point or a back-to-back HVDC system.
This document can also be used for DC grid systems (including multi-terminal HVDC systems) as a reference.
This document is not exhaustive. It is possible that there are other specific aspects, that are particularly important for a specific HVDC project.

  • Technical report
    37 pages
    English language
    sale 15% off

IEC 61643-21:2025 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are intended to be connected to telecommunications and signalling networks, and equipment rated up to 1 000 V RMS and 1 500 V DC. These telecommunications and signalling networks can also provide power on the same line, e.g. Power over Ethernet (PoE). Performance and safety requirements, tests and ratings are specified in this document. These devices contain at least one voltage-limiting component (clamping or switching) and are intended to limit surge voltages and divert surge currents. This second edition cancels and replaces the first edition published in 2000, Amendment1:2008 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) New structure of IEC 61643-21 based on IEC 61643-01:2024; b) Several safety requirements based on IEC 61643-01:2024 have been added. This International Standard is to be used in conjunction with IEC 61643-01:2024.

  • Standard
    89 pages
    English language
    e-Library read for
    1 day

European common modification to EN 61936-1

  • Amendment
    16 pages
    English language
    e-Library read for
    1 day

IEC 60358-1:2025 This part of IEC 60358 applies to:
Coupling capacitors and capacitor dividers, with rated voltage > 1 000 V, connected line to ground with the low-voltage terminal either permanently earthed or connected to devices, for applications listed hereunder and other similar uses.
This document serves as a basic standard for the coupling capacitors and capacitor dividers.

  • Standard
    77 pages
    English language
    sale 15% off
  • Standard
    86 pages
    English language
    sale 15% off
  • Standard
    80 pages
    French language
    sale 15% off
  • Standard
    157 pages
    English and French language
    sale 15% off

IEC 61643-11:2025 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages.
These devices are intended to be connected to AC power circuits and equipment rated up to 1 000 V RMS, the preferred frequencies taken into account in this document are 50/60 Hz. Other frequencies are not excluded. Performance and safety requirements, tests and ratings are specified in this document. These devices contain at least one nonlinear component and are intended to limit surge voltages and divert surge currents.
The test requirements provided by this document are based on the assumption that the SPD is connected to an AC power circuit fed by a power source providing a linear voltage-current characteristic. When the SPD is to be connected to a different kind of source or to a different frequency, careful consideration is required. This mainly applies with regard to system and fault conditions to be expected in such a system (e.g. expected short circuit current, TOV-stresses).
This document can apply for railway applications, when related product standards do not exist for that area or for certain applications.
Based on a risk assessment it might not be necessary to apply all requirements of this document to SPDs designed for specific power applications only, e.g. circuits with a low power capability, circuits supplied by nonlinear sources, circuits with protective separation from the utility supply.
NOTE 1 More information on risk assessment is provided in IEC Guide 116.
NOTE 2 Other exclusions based on national regulations are possible.
This edition includes the following significant technical changes with respect to the previous edition:
a) Specific requirements for SPDs for AC applications are now contained in this document, whereas the common requirements for all SPDs are now contained in IEC 61643-01;
b) Clarification on test application either to a complete SPD, to a "mode of protection", or to a complete "SPD assembly";
c) Additional measurement of voltage protection level on "combined modes of protection" between live conductors and PE;
d) Additional duty test for T1 and T2 SPDs with follow current to check variation of the follow current value at lower impulse currents;
e) Modified and amended short circuit current test requirements to better cover up to date internal SPD disconnector technologies;
f) Improved dielectric test requirements for the SPD's main circuits and added dielectric test requirements for "electrically separated circuits";
g) Additional clearance requirements for "electrically separated circuits".
The requirements of this document supplement, modify or replace certain of the general requirements contained in IEC 61643-01 and shall be read and applied together with the latest edition of IEC 61643-01, as indicated by the undated normative reference in Clause 2 of this document.

  • Standard
    43 pages
    English language
    e-Library read for
    1 day