Status
Not Published
Public Enquiry End Date
20-Dec-2026
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
06-Oct-2026
Due Date
23-Feb-2027

Buy Documents

Draft

oSIST prEN IEC 63562:2026

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

oSIST prEN IEC 63562:2026 is the Slovenian standard published by SIST for the IEC draft on the safety of low-pressure mercury UV radiation sources for germicidal purpose. It specifies safety requirements for manufacturers, test laboratories, and luminaire designers working with these sources. The document is still under study and organizes its requirements by source category, with rules for marking, electrical, thermal, mechanical, photobiological, ozone, and material-aging safety.

What does oSIST prEN IEC 63562:2026 specify?

oSIST prEN IEC 63562:2026 specifies the safety requirements of low-pressure mercury UV radiation sources for germicidal purposes. Clause 4 divides the sources into categories A, B, and C, which is important because several requirements depend on the cap construction.

AnnexWhat it covers
Annex ANormative correspondence between the clauses in this document and the equivalent clauses in existing safety standards
Annex BInformative guidance for luminaire design, including water contact and protection against potential hazards

The body of the document runs from Clause 1 to Clause 13. It includes general requirements and test conditions, marking, electrical safety, thermal safety, mechanical safety, actinic UV hazard, ozone generation, resistance to UV radiation and ozone exposure, and other safety requirements.

What are the key requirements of oSIST prEN IEC 63562:2026?

oSIST prEN IEC 63562:2026 is built around type testing, category-based requirements, and cross-references to existing lamp safety standards. The most practical takeaway is that the document does not treat all low-pressure mercury UV sources the same - the cap type, controlgear, and declared hazard data determine which tests and markings apply.

Test planning and sample selection

Clause 5 says the tests are type tests, so they are intended for representative samples submitted by the manufacturer. The sample should represent the most onerous case in a product range, and if a source uses a cap not specified in IEC 60061-1, the associated lampholder sample is also needed. If a source needs external controlgear, Clause 5.2.4 requires testing with the designated controlgear. In practice, this means the manufacturer has to define the exact test configuration before qualification testing starts.

Marking and user information

Clause 6 requires product marking and packaging or documentation information. The source itself must carry items such as origin, nominal power, rated power, UV warning, voltage, frequency, product type, and, where applicable, actinic UV risk group and UV warning symbols. Packaging, instructions, or specification sheets carry the rest, including ozone warnings, installation instructions, dimensions, cap data, maximum cap temperature, pull/bend/torque limits, mass and bending moment, controlgear information, and rated lifetime. This matters because users and installers need the hazard, connection, and handling data before the source is put into service.

Electrical, thermal, and mechanical safety

Clause 7 applies electrical safety to category A and B sources, while category C is excluded from that clause. Category B sources with non-standardized caps need a risk analysis for electric shock protection, and hazardous live parts must not be accessible with the source installed, being inserted, or absent. Clauses 8 and 9 add thermal and mechanical checks: cap temperature rise, resistance to heat and flame, cap construction, adhesive strength, axial strength, mass, bending moment, and source dimensions. In practice, these clauses control overheating, loose caps, unsafe handling forces, and fit with lampholders.

Photobiological hazard, ozone, and aging

Clause 10 limits the actinic UV hazard risk group at a 200 mm assessment distance to the declared level, measured under IEC 62471 after aging the source for 100 h unless another aging period is declared. Clause 11 requires ozone-free sources, or sources without ozone warnings, not to generate hazardous ozone, with measurement according to IEC 63561. Clause 12 requires materials exposed to UV-C or ozone to withstand that exposure, with strength loss limited and electrical insulation required to survive without breakdown. This is the part that links product design to real service life.

Other safety requirements

Clause 13 ties the source back to the existing safety standards for radio interference suppression capacitors, fault conditions, source end-of-life, and abnormal operation. Annex A shows exactly where those requirements come from in the existing standards for different source categories.

What terms does oSIST prEN IEC 63562:2026 define?

oSIST prEN IEC 63562:2026 uses a short set of technical terms that shape the whole document.

  • LPM UV source - a low-pressure mercury UV radiation source that emits either 254 nm alone or 185 nm and 254 nm together, and may use hot or cold cathodes.
  • Category A LPM UV source - a source with cap(s) covered by IEC 60968, IEC 61195, or IEC 61199.
  • Category B LPM UV source - a source with cap(s) not covered by category A, so the cap specification is declared by the manufacturer.
  • Category C LPM UV source - a source without a cap.
  • Actinic UV hazard - the skin and eye hazard from UV between 200 nm and 400 nm.
  • External controlgear - separate controlgear used to operate the source.
  • Lampholder - the holder interface used with the source cap and checked through the referenced cap-and-holder standards.

Who uses oSIST prEN IEC 63562:2026?

oSIST prEN IEC 63562:2026 is used by manufacturers of germicidal UV sources, luminaire designers, and test laboratories that verify safety and marking. It is also relevant to quality managers and certification teams that need to assess shock protection, thermal behavior, UV hazard labeling, ozone behavior, and material durability. Buyers specifying germicidal equipment use it to compare source types and to check that the source has the safety information needed for installation and use.

What changed in oSIST prEN IEC 63562:2026 from the previous edition?

oSIST prEN IEC 63562:2026 supersedes 34/1418/CD and 34/1471/CC.

Which standards are used with oSIST prEN IEC 63562:2026?

oSIST prEN IEC 63562:2026 depends on several referenced standards for parts of its safety assessment.

  • IEC 60061-1, IEC 60061-2, IEC 60061-4 - lamp caps, holders, gauges, and guidance for interchangeability and safety.
  • IEC 60085 - thermal evaluation and designation of insulation, used for lead-wire thermal class.
  • IEC 60243 - electrical strength test methods for insulating materials.
  • IEC 60968:2015, IEC 61195:2014, IEC 61199:2014 - the existing lamp safety standards used as the baseline for several category-based requirements.
  • IEC 61032:1997 - probe B for accessibility checks of hazardous live parts.
  • IEC 62471:2006 and IEC 62471-6:2022 - photobiological safety and actinic UV risk group assessment.
  • IEC 63561 - ozone production measurement from UV-C sources and luminaires.
  • ISO 178, ISO 527 (all parts), ISO 1431-1 - flexural, tensile, and ozone-cracking tests used in material exposure evaluation.

What does the oSIST prEN IEC 63562:2026 document contain?

The document contains a clause structure for safety requirements, a marking table, and two figures showing UV warning symbols. It also includes two normative tables in Annex A that map this document to corresponding clauses in existing standards for category A, B, and C sources. Annex B gives design guidance for luminaires, including water contact and protection against actinic UV, material degradation, and ozone generation.

It also sets out the test approaches used throughout the standard: type tests, visual inspection, manual accessibility checks with a test finger, measurements for thermal and mechanical limits, ozone measurement, and material exposure tests for UV-C and ozone.

Buy Documents

Draft

oSIST prEN IEC 63562:2026

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

oSIST prEN IEC 63562:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Germicidal equipment - Low-pressure mercury UV radiation sources for germicidal purpose - Safety". This standard covers: Germicidal equipment - Low-pressure mercury UV radiation sources for germicidal purpose - Safety

Germicidal equipment - Low-pressure mercury UV radiation sources for germicidal purpose - Safety

oSIST prEN IEC 63562:2026 is classified under the following ICS (International Classification for Standards) categories: 11.080.10 - Sterilizing equipment; 29.140.01 - Lamps in general. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN IEC 63562:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU; Standardization Mandates: M/511. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

oSIST prEN IEC 63562:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2026
Germicidna oprema - Nizkotlačni živosrebrni viri UV-sevanja za germicidne
namene – Varnost
Germicidal equipment - Low-pressure mercury UV radiation sources for germicidal
purpose - Safety
Équipement germicide - Sources de rayonnement UV au mercure à basse pression
destinées à un usage germicide - Sécurité
Ta slovenski standard je istoveten z: prEN IEC 63562:2026
ICS:
11.080.10 Sterilizacijska oprema Sterilizing equipment
29.140.01 Žarnice na splošno Lamps in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

34/1495/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 63562 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2026-10-02 2026-12-25
SUPERSEDES DOCUMENTS:
34/1418/CD, 34/1471/CC
IEC TC 34 : LIGHTING
SECRETARIAT: SECRETARY:
United Kingdom Mr Petar Luzajic
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):

ASPECTS CONCERNED:
Safety
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Germicidal equipment - Low-pressure mercury UV radiation sources for germicidal purpose -
Safety
PROPOSED STABILITY DATE: 2030
NOTE FROM TC/SC OFFICERS:
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, o r any part of it, for
any other purpose without permission in writing from IEC.

IEC CDV 63562 © IEC 2026
1 CONTENTS
3 FOREWORD . 3
4 INTRODUCTION . 5
5 1 Scope . 6
6 2 Normative references . 6
7 3 Terms and definitions . 6
8 4 Classification . 7
9 5 General . 7
10 5.1 General requirement . 7
11 5.2 General conditions for tests . 7
12 5.2.1 Type test . 7
13 5.2.2 Test samples . 7
14 5.2.3 Compliance by inspection of relevant data . 7
15 5.2.4 External controlgear . 7
16 6 Marking . 8
17 6.1 Overview. 8
18 6.2 Marking content . 9
19 6.3 LPM UV source marking . 10
20 6.4 Durability and legibility of marking . 11
21 7 Electrical safety . 11
22 7.1 General . 11
23 7.2 Protection against electric shock . 11
24 7.2.1 Category A LPM UV sources . 11
25 7.2.2 Category B LPM UV sources . 11
26 7.3 Insulation resistance . 11
27 7.4 Electric strength . 11
28 7.4.1 Creepage distance and clearance . 11
29 7.4.2 Category A LPM UV sources . 11
30 7.4.3 Category B LPM UV sources . 11
31 8 Thermal safety . 12
32 8.1 Category A LPM UV sources . 12
33 8.2 Category B LPM UV sources . 12
34 8.2.1 Cap temperature rise . 12
35 8.2.2 Resistance to heat . 12
36 8.2.3 Resistance to flame and ignition . 12
37 8.3 Category C UV LPM sources. 12
38 8.3.1 Resistance to heat . 12
39 8.3.2 Resistance to flame and ignition . 12
40 9 Mechanical safety . 12
41 9.1 Mechanical requirements for caps . 12
42 9.1.1 Category A LPM UV sources . 12
43 9.1.2 Category B LPM UV sources . 12
44 9.2 Mechanical requirements for Category C LPM UV sources . 13
45 9.3 Source mass and bending moment imparted by the source at the lampholder . 13
46 9.3.1 Category A LPM UV sources . 13
IEC CDV 63562 © IEC 2026
47 9.3.2 Category B and category C LPM UV sources . 13
48 9.4 Source Dimension of category A and category B LPM UV sources . 13
49 10 Actinic UV hazard . 13
50 11 Ozone generation . 14
51 12 Resistance to UV radiation and ozone exposure . 14
52 12.1 General . 14
53 12.2 Exposure to UV-C radiation . 14
54 12.3 Exposure to ozone . 14
55 13 Other safety requirements . 14
56 Annex A (normative) Corresponding clauses in existing standard for safety
57 requirements . 15
58 Annex B (Informative) Information for luminaire design . 17
59 B.1 General . 17
60 B.2 Water contact . 17
61 B.3 Protection of against potential hazards . 17
IEC CDV 63562 © IEC 2026
65 INTERNATIONAL ELECTROTECHNICAL COMMISSION
66 ____________
68 GERMICIDAL EQUIPMENT — LOW-PRESSURE MERCURY UV RADIATION
69 SOURCES FOR GERMICIDAL PURPOSE — SAFETY
72 FOREWORD
73 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
74 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
75 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
76 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
77 Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
78 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
79 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
80 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
81 Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
82 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
83 consensus of opinion on the relevant subjects since each technical committee has representation from all
84 interested IEC National Committees.
85 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
86 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
87 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
88 misinterpretation by any end user.
89 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
90 transparently to the maximum extent possible in their national and regional publications. Any divergence between
91 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
92 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
93 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
94 services carried out by independent certification bodies.
95 6) All users should ensure that they have the latest edition of this publication.
96 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
97 members of its technical committees and IEC National Committees for any personal injury, property damage or
98 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
99 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
100 Publications.
101 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
102 indispensable for the correct application of this publication.
103 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
104 rights. IEC shall not be held responsible for identifying any or all such patent rights.
105 IEC 6XXXX has been prepared by IEC technical committee 34: Lighting. It is an International
106 Standard.
107 The text of this International Standard is based on the following documents:
Draft Report on voting
XX/XX/FDIS XX/XX/RVD
109 Full information on the voting for its approval can be found in the report on voting indicated in
110 the above table.
111 The language used for the development of this International Standard is English.
112 This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
113 accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
114 at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
115 described in greater detail at www.iec.ch/publications.
IEC CDV 63562 © IEC 2026
116 The committee has decided that the contents of this document will remain unchanged until the
117 stability date indicated on the IEC website under webstore.iec.ch in the data related to the
118 specific document. At this date, the document will be
119 • reconfirmed,
120 • withdrawn,
121 • replaced by a revised edition, or
122 • amended.
IEC CDV 63562 © IEC 2026
124 INTRODUCTION
125 This document acknowledges the need for safety specifications for low-pressure mercury UV
126 radiation sources for germicidal purpose, which mainly generate single-line spectrum radiation
127 of 254 nm or dual-line spectrum radiation of 185 nm and 254 nm.
128 This document was prepared by referencing, wherever possible, the existing standards for
129 similar types of discharge lamps used in general lighting: IEC 61195:2014, IEC 61199:2014 and
130 IEC 60968:2015. Additional or deviated requirements for germicidal UV sources are specified
131 wherever necessary.
132 The provisions in this document represent the technical knowledge of experts from the field of
133 the UV radiation for germicidal purpose, and are developed in close context with the safety of
134 other type of UV radiation sources for germicidal purpose, e.g., excimer sources.
IEC CDV 63562 © IEC 2026
136 GERMICIDAL EQUIPMENT — LOW-PRESSURE MERCURY UV RADIATION
137 SOURCES FOR GERMICIDAL PURPOSE — SAFETY
139 1 Scope
140 This document specifies the safety requirements of low-pressure mercury UV radiation sources
141 for germicidal purposes.
142 2 Normative references
143 The following documents are referred to in the text in such a way that some or all of their content
144 constitutes requirements of this document. For dated references, only the edition cited applies.
145 For undated references, the latest edition of the referenced document (including any
146 amendments) applies.
147 IEC 60061-1, Lamp caps and holders together with gauges for the control of interchangeability
148 and safety - Part 1: Lamp caps
149 IEC 60061-2, Lamp caps and holders together with gauges for the control of interchangeability
150 and safety - Part 2: Lampholders
151 IEC 60061-4, Lamp caps and holders together with gauges for the control of interchangeability
152 and safety – Part 4: Guidelines and general information
153 IEC 60085, Electrical insulation – Thermal evaluation and designation
154 IEC 60243, Electrical strength of insulating materials – Test methods
155 IEC 60968:2015, Self-ballasted fluorescent lamps for general lighting services - Safety
156 requirements
157 IEC 61032:1997: Protection of persons and equipment by enclosures - Probes for verification
158 IEC 61195:2014, Double-capped fluorescent lamps – Safety specifications
159 IEC 61199:2014, Single-capped fluorescent lamps – Safety specifications
160 IEC 62471:2006, Photobiological safety of lamps and lamp systems
161 IEC 62471-6:2022, Photobiological safety of lamps and lamp systems - Part 6: Ultraviolet lamp
162 products
163 IEC 63561, Measurement of ozone production from UV-C radiation sources and luminaires
164 ISO 178, Plastics - Determination of flexural properties
165 ISO 527 (all parts), Plastics - Determination of tensile properties
166 ISO 1431-1, Rubber, vulcanized or thermoplastic – Resistance to ozone cracking – Part 1:
167 Static and dynamic strain testing
168 3 Terms and definitions
169 For the purposes of this document, the terms and definitions given in IEC 60050 -845 and the
170 following apply.
171 ISO and IEC maintain terminology databases for use in standardization at the following
172 addresses:
173 • IEC Electropedia: available at https://www.electropedia.org/

IEC 63561 is under preparation.
IEC CDV 63562 © IEC 2026
174 • ISO Online browsing platform: available at https://www.iso.org/obp
175 3.1
176 LPM UV source
177 UV radiation source which emits either a single-line spectrum at 254 nm or dual-line spectrum
178 at 185 nm and 254 nm from a low-pressure mercury gaseous discharge
179 Note 1 to entry: An LPM UV source can have hot cathodes or cold cathodes, and is incorporated with suitable high
180 UV transmittance glass without phosphor coating.
181 Note 2 to entry: An LPM UV lamp is an LPM UV source with at least one cap.
182 4 Classification
183 The LPM UV sources shall be classified as follows.
184 – Category A: LPM UV sources with cap(s) specified in IEC 60968, IEC 61195 or IEC 61199,
185 – Category B: LPM UV sources with cap(s) not covered by category A,
186 – Category C: LPM UV sources without a cap.
187 NOTE 1 LPM UV sources with a hot-cathode normally have caps.
188 NOTE 2 Category A LPM UV sources can have lamp dimensions that are different from those specified in the
189 datasheets of existing standards for fluorescent lamp performance.
190 NOTE 3 Category B LPM UV sources can have the cap(s) specified in IEC 60061-1.
191 5 General
192 5.1 General requirement
193 Unless specifically indicated in following clauses, the safety requirements are applicable to all
194 categories of LPM UV sources.
195 Information for luminaire design is given in Annex C.
196 5.2 General conditions for tests
197 5.2.1 Type test
198 Tests according to this document are type tests.
199 NOTE The requirements and tolerances specified in this document are related to testing of a type test sample
200 submitted by the manufacturer for that purpose. Compliance of type test samples does not ensure compliance of the
201 whole production of a manufacturer with this document. Conformity of production is the responsibility of the
202 manufacturer and routine tests and quality insurance in addition to the type test can be necessary.
203 5.2.2 Test samples
204 Unless otherwise specified, the type test shall be carried out on one sample consisting of one
205 or more items submitted for the purpose of the type test.
206 Where there is a range of similar LPM UV sources for testing, samples representing the most
207 onerous case within the range shall be selected as relevant to the test criteria.
208 NOTE For example, damage to marking as a result of the marking test has no impact on electrical testing, thus
209 the LPM UV source is still considered to be representative of production for other tests.
210 If the source is provided with a cap that is not specified in IEC 60061-1, a sample of the
211 associated lampholder shall be provided for the test.
212 5.2.3 Compliance by inspection of r
...