EN 61000-4-6:1996
(Main)Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
Relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection), which can couple the equipment to the disturbing RF fields is excluded. This standard does not intend to specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to all concerned product committes of the IEC. The product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the test and the severity level to be applied to their equipment.
Elektromagnetische Verträglichkeit (EMV) - Teil 4-6: Prüf- und Meßverfahren - Störfestigkeit gegen leitungsgeführte Störgrößen, induziert durch hochfrequente Felder
Compatibilité électromagnétique (CEM) - Partie 4-6: Techniques d'essai et de mesure - Immunité aux perturbations conduites, induites par les champs radioélectriques
Se rapporte aux prescriptions relatives à l'immunité en conduction des équipements électriques et électroniques aux perturbations électromagnétiques provoquées par des émetteurs HF, dans la plage de fréquences de 9 kHz à 80 MHz. Les matériels n'ayant pas au moins un câble conducteur (tel que cordons d'alimentation, ligne de transmission de signaux ou connexions de mise à la terre) qui peut coupler les matériels aux champs RF perturbateurs ne sont pas concernés par cette norme. Cette norme ne vise pas à spécifier les essais devant s'appliquer à des appareils ou systèmes particuliers. Le but principal est de donner une référence de base d'ordre général à tous les comités de produits CEI concernés. Les comités de produits (ou les utilisateurs et les fabricants de matériels) restent responsables du choix approprié des essais et du niveau de sévérité à appliquer à leur matériel.
Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 6: Immunity to conducted disturbances, induced by radio-frequency fields (IEC 1000-4-6:1996)
General Information
- Status
- Withdrawn
- Publication Date
- 28-Jul-1996
- Withdrawal Date
- 31-Mar-1997
- Technical Committee
- CLC/TC 210 - Electromagnetic Compatibility (EMC)
- Drafting Committee
- IEC/SC 77B - IEC_SC_77B
- Parallel Committee
- IEC/SC 77B - IEC_SC_77B
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Jun-2010
- Completion Date
- 01-Jun-2010
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 28-Jan-2023
- Effective Date
- 28-Jan-2023
- Effective Date
- 28-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

UL Solutions
Global safety science company with testing, inspection and certification.
CEPREI Certification Center (Guangzhou Saibao)
Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.
CESI Beijing Certification (Saisi)
Subsidiary of China Electronics Standardization Institute (CESI), established 1963.
Sponsored listings
Frequently Asked Questions
EN 61000-4-6:1996 is a standard published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields". This standard covers: Relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection), which can couple the equipment to the disturbing RF fields is excluded. This standard does not intend to specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to all concerned product committes of the IEC. The product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the test and the severity level to be applied to their equipment.
Relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection), which can couple the equipment to the disturbing RF fields is excluded. This standard does not intend to specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to all concerned product committes of the IEC. The product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the test and the severity level to be applied to their equipment.
EN 61000-4-6:1996 is classified under the following ICS (International Classification for Standards) categories: 29.020 - Electrical engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61000-4-6:1996 has the following relationships with other standards: It is inter standard links to ENV 50141:1993, EN 61000-4-6:2007, EN 61000-4-6:1996/A1:2001, EN 61000-4-6:1996/IS1:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61000-4-6:1996 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 89/336/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 61000-4-6:1996 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-1997
1DGRPHãþD
SIST ENV 50141:1997
Electromagnetic compatibility (EMC) - Part 4: Testing and measurement
techniques - Section 6: Immunity to conducted disturbances, induced by radio-
frequency fields (IEC 1000-4-6:1996)
Electromagnetic compatibility (EMC) -- Part 4-6: Testing and measurement techniques -
Immunity to conducted disturbances, induced by radio-frequency fields
Elektromagnetische Verträglichkeit (EMV) -- Teil 4-6: Prüf- und Meßverfahren -
Störfestigkeit gegen leitungsgeführte Störgrößen, induziert durch hochfrequente Felder
Compatibilité électromagnétique (CEM) -- Partie 4-6: Techniques d'essai et de mesure -
Immunité aux perturbations conduites, induites par les champs radioélectriques
Ta slovenski standard je istoveten z: EN 61000-4-6:1996
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...