A European Standardization Mandate is a formal request from the European Commission to the European Standardization Organizations (CEN, CENELEC, and ETSI) to develop European standards (ENs) in support of EU legislation and policies. Mandates are issued under Regulation (EU) No 1025/2012 and help ensure that products and services meet the essential requirements set out in EU directives and regulations.
M/248 is a European Standardization Mandate titled "Standardization mandate to CEN and CENELEC for quality assurance of automated measuring systems". Standardization mandate to CEN and CENELEC for quality assurance of automated measuring systems There are 4 standards developed under this mandate.
Standards developed in response to a mandate and cited in the Official Journal of the European Union become "harmonized standards". Products manufactured in compliance with harmonized standards benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation, facilitating CE marking and market access across the European Economic Area.
This European Standard specifies procedures for establishing quality assurance levels (QAL) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.
This European Standard specifies:
- a procedure (QAL2) to calibrate the AMS and determine the variability of the measured values obtained by it, so as to demonstrate the suitability of the AMS for its application, following its installation;
- a procedure (QAL3) to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent with those determined during QAL1;
- a procedure for the annual surveillance tests (AST) of the AMS in order to evaluate (i) that it functions correctly and its performance remains valid and (ii) that its calibration function and variability remain as previously determined.
This European Standard is designed to be used after the AMS has been certified in accordance with the series of European Standards EN 15267.
- Standard84 pagesEnglish languagee-Library read for1 day
This European Standard specifies procedures for establishing quality assurance levels (QAL) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.
This European Standard specifies:
- a procedure (QAL2) to calibrate the AMS and determine the variability of the measured values obtained by it, so as to demonstrate the suitability of the AMS for its application, following its installation;
- a procedure (QAL3) to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent with those determined during QAL1;
- a procedure for the annual surveillance tests (AST) of the AMS in order to evaluate (i) that it functions correctly and its performance remains valid and (ii) that its calibration function and variability remain as previously determined.
This European Standard is designed to be used after the AMS has been certified in accordance with the series of European Standards EN 15267.
- Standard84 pagesEnglish languagee-Library read for1 day
This European Standard specifies procedures for establishing quality assurance levels (QALs) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.
This European Standard specifies procedures for establishing quality assurance levels (QALs) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.
This standard specifies:
- a procedure (QAL 2) to calibrate the AMS and determine the variability of the measured values obtained by an automated measurement system which is suitable for the validation of an AMS following its installation;
- a procedure (QAL 3) to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent with those determined during QAL 1;
- a procedure for the annual surveillance tests (AST) of the AMS in order to evaluate (i) that it functions correctly and its performance remains valid and (ii) that its calibration function and variability remain as previously determined.
This standard is designed to be used after the AMS has been accepted according to the procedures specified in EN ISO 14956 (QAL 1).
This standard is restricted to quality assurance (QA) of the AMS, and does not include QA of the data collection and recording system of the plant.
- Standard59 pagesEnglish languagee-Library read for1 day
This European Standard specifies procedures for establishing quality assurance levels (QALs) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.
This European Standard specifies procedures for establishing quality assurance levels (QALs) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.
This standard specifies:
- a procedure (QAL 2) to calibrate the AMS and determine the variability of the measured values obtained by an automated measurement system which is suitable for the validation of an AMS following its installation;
- a procedure (QAL 3) to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent with those determined during QAL 1;
- a procedure for the annual surveillance tests (AST) of the AMS in order to evaluate (i) that it functions correctly and its performance remains valid and (ii) that its calibration function and variability remain as previously determined.
This standard is designed to be used after the AMS has been accepted according to the procedures specified in EN ISO 14956 (QAL 1).
This standard is restricted to quality assurance (QA) of the AMS, and does not include QA of the data collection and recording system of the plant.