M/626 - MID
COMMISSION IMPLEMENTING DECISION of 28.7.2026 on a standardisation request to the European Committee for Standardization, to the European Committee for Electrotechnical Standardization and to the European Telecommunications Standards Institute as regards certain measuring instruments in support of Directive 2014/32/EU of the European Parliament and of the Council
This document specifies ranges, construction, performances, output characteristics and testing of rotary displacement gas meters (hereinafter referred to as RD meters or simply meters) for gas volume measurement.
This document applies to rotary displacement gas meters used to measure the volume of fuel gases of at least the 1st, 2nd and 3rd gas families, the composition of which is specified in EN 437:2021, at a maximum working pressure up to and including 20 bar over an ambient and gas temperature range of at least −10 °C to +40 °C.
This document applies to meters that are installed in locations with vibration and shocks of low significance (class M1) and in
- closed locations (indoor or outdoor with protection) with condensing or with non-condensing humidity
or,
- open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity,
and in locations with electromagnetic disturbances (class E1 and E2). The standard applies to mechanical meters with mechanical index, electronic devices are not covered by this standard.
Unless otherwise specified in this standard:
- all pressures used are gauge;
- all influence quantities, except the one under test, are kept relatively constant at their reference value.
This document applies to meters with a maximum allowable pressure PS and the volume V of less than 6 000 bar · L or with a product of PS and DN of less than 3 000 bar.
This document is to be used for both pattern approval and individual meter testing. Cross-reference tables are given in:
- Annex A for the tests that need to be undertaken for pattern approval;
- Annex B for individual meter testing.
Some parts of this standard cover meters with mechanical index only.
The risk philosophy adopted in this standard is based on the analysis of hazards including pressure. The standard applies principles to eliminate or reduce hazards. Where these hazards cannot be eliminated appropriate protection measures are specified.
- Standard73 pagesEnglish languagee-Library read for
This document specifies ranges, construction, performances, output characteristics and testing of rotary displacement gas meters (hereinafter referred to as RD meters or simply meters) for gas volume measurement.
This document applies to rotary displacement gas meters used to measure the volume of fuel gases of at least the 1st, 2nd and 3rd gas families, the composition of which is specified in EN 437:2021, at a maximum working pressure up to and including 20 bar over an ambient and gas temperature range of at least −10 °C to +40 °C.
This document applies to meters that are installed in locations with vibration and shocks of low significance (class M1) and in
- closed locations (indoor or outdoor with protection) with condensing or with non-condensing humidity
or,
- open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity,
and in locations with electromagnetic disturbances (class E1 and E2). The standard applies to mechanical meters with mechanical index, electronic devices are not covered by this standard.
Unless otherwise specified in this standard:
- all pressures used are gauge;
- all influence quantities, except the one under test, are kept relatively constant at their reference value.
This document applies to meters with a maximum allowable pressure PS and the volume V of less than 6 000 bar · L or with a product of PS and DN of less than 3 000 bar.
This document is to be used for both pattern approval and individual meter testing. Cross-reference tables are given in:
- Annex A for the tests that need to be undertaken for pattern approval;
- Annex B for individual meter testing.
Some parts of this standard cover meters with mechanical index only.
The risk philosophy adopted in this standard is based on the analysis of hazards including pressure. The standard applies principles to eliminate or reduce hazards. Where these hazards cannot be eliminated appropriate protection measures are specified.
- Standard73 pagesEnglish languagee-Library read for
This document is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064-1:2024|OIML R 49‑1:2024. OIML Certificates of conformity can be issued for water meters under the scope of the OIML Certificate System, provided that this document, ISO 4064-1:2024|OIML R 49‑1:2024 and ISO 4064-3:2024|OIML R 49‑3:2024 are used in accordance with the rules of the system.
This document sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type.
The provisions of this document also apply to ancillary devices, if required by national regulations.
The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.
- Standard114 pagesEnglish languagee-Library read for
This document specifies the metrological and technical requirements for water meters for cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the accumulated volume.
In addition to water meters based on mechanical principles, this document applies to devices based on electrical or electronic principles, and mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water.
This document also applies to electronic ancillary devices. Ancillary devices are optional. However, it is possible for national or regional regulations to render some ancillary devices mandatory in relation to the utilization of water meters.
NOTE Any national regulations apply in the country of use.
- Standard58 pagesEnglish languagee-Library read for
This document is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064-1:2024|OIML R 49‑1:2024. OIML Certificates of conformity can be issued for water meters under the scope of the OIML Certificate System, provided that this document, ISO 4064-1:2024|OIML R 49‑1:2024 and ISO 4064-3:2024|OIML R 49‑3:2024 are used in accordance with the rules of the system.
This document sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type.
The provisions of this document also apply to ancillary devices, if required by national regulations.
The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.
- Standard114 pagesEnglish languagee-Library read for
This document specifies the metrological and technical requirements for water meters for cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the accumulated volume.
In addition to water meters based on mechanical principles, this document applies to devices based on electrical or electronic principles, and mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water.
This document also applies to electronic ancillary devices. Ancillary devices are optional. However, it is possible for national or regional regulations to render some ancillary devices mandatory in relation to the utilization of water meters.
NOTE Any national regulations apply in the country of use.
- Standard58 pagesEnglish languagee-Library read for
This document applies only to static watt-hour meters of accuracy classes A, B and C for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests.
NOTE 1 For general requirements, such as construction, EMC, safety, dependability etc., see the relevant EN 62052 series or EN 62059 series.
This document applies to electricity metering equipment designed to:
- measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC;
NOTE 2 For AC electricity meters, the voltage mentioned above is the line-to-neutral voltage derived from nominal voltages. See EN 62052-31:2016, Table 7. EN 62052 31:2016 covers AC voltages only up to 600 V and Ed. 2 of EN IEC 62052 31 will cover AC voltages up to 1000 V.
- have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;
- operate with integrated or detached indicating displays;
- be installed in specified matching sockets or racks;
- optionally, provide additional functions other than those for measurement of electrical energy.
Meters designed for operation with low power instrument transformers (LPITs as defined in the EN 61869 series) can be tested for compliance with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters.
NOTE 3 Modern electricity meters typically contain additional functions such as measurement of voltage magnitude, current magnitude, power, frequency, power factor, etc.; measurement of power quality parameters; load control functions; delivery, time, test, accounting, recording functions; data communication interfaces and associated data security functions. The relevant standards for these functions could apply in addition to the requirements of this document. However, the requirements for such functions are outside the scope of this document.
NOTE 4 Product requirements for power metering and monitoring devices (PMDs) and measurement functions such as voltage magnitude, current magnitude, power, frequency, etc., are covered in EN 61557-12:2008. However, devices compliant with EN 61557-12:2008 are not intended to be used as billing meters unless they are also compliant with the EN IEC 62052-11:2021/A11:2022 and EN 50470-3:2022 standards.
NOTE 5 Product requirements for power quality instruments (PQIs) are covered in EN 62586-1:2017. Requirements for power quality measurement techniques (functions) are covered in EN 61000-4-30:2015. Requirements for testing of the power quality measurement functions are covered in EN 62586-2:2017.
This document does not apply to:
- meters for which the line-to-neutral voltage derived from nominal voltages exceeds 1 000 V AC;
- meters intended for connection with low power instrument transformers (LPITs as defined in the EN 61869 series) when tested without such transformers;
- metering systems comprising multiple devices (except of LPITs) physically remote from one another;
- portable meters;
NOTE 6 Portable meters are meters that are not permanently connected.
- meters used in rolling stock, vehicles, ships and airplanes;
- laboratory and meter test equipment;
- reference standard meters;
- data interfaces to the register of the meter;
- matching sockets or racks used for installation of electricity metering equipment;
- any additional functions provided in electrical energy meters.
This document does not cover measures for the detection and prevention of fraudulent attempts to compromise meter’s performance (tampering).
[...]
- Standard29 pagesEnglish languagee-Library read for
This document applies only to static watt-hour meters of accuracy classes A, B and C for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests. NOTE 1 For general requirements, such as construction, EMC, safety, dependability etc., see the relevant EN 62052 series or EN 62059 series. This document applies to electricity metering equipment designed to: - measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC; NOTE 2 For AC electricity meters, the voltage mentioned above is the line-to-neutral voltage derived from nominal voltages. See EN 62052-31:2016, Table 7. EN 62052 31:2016 covers AC voltages only up to 600 V and Ed. 2 of EN IEC 62052 31 will cover AC voltages up to 1000 V. - have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays; - operate with integrated or detached indicating displays; - be installed in specified matching sockets or racks; - optionally, provide additional functions other than those for measurement of electrical energy. Meters designed for operation with low power instrument transformers (LPITs as defined in the EN 61869 series) can be tested for compliance with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters. NOTE 3 Modern electricity meters typically contain additional functions such as measurement of voltage magnitude, current magnitude, power, frequency, power factor, etc.; measurement of power quality parameters; load control functions; delivery, time, test, accounting, recording functions; data communication interfaces and associated data security functions. The relevant standards for these functions could apply in addition to the requirements of this document. However, the requirements for such functions are outside the scope of this document. NOTE 4 Product requirements for power metering and monitoring devices (PMDs) and measurement functions such as voltage magnitude, current magnitude, power, frequency, etc., are covered in EN 61557-12:2008. However, devices compliant with EN 61557-12:2008 are not intended to be used as billing meters unless they are also compliant with the EN IEC 62052-11:2021/A11:2022 and EN 50470-3:2022 standards. NOTE 5 Product requirements for power quality instruments (PQIs) are covered in EN 62586-1:2017. Requirements for power quality measurement techniques (functions) are covered in EN 61000-4-30:2015. Requirements for testing of the power quality measurement functions are covered in EN 62586-2:2017. This document does not apply to: - meters for which the line-to-neutral voltage derived from nominal voltages exceeds 1 000 V AC; - meters intended for connection with low power instrument transformers (LPITs as defined in the EN 61869 series) when tested without such transformers; - metering systems comprising multiple devices (except of LPITs) physically remote from one another; - portable meters; NOTE 6 Portable meters are meters that are not permanently connected. - meters used in rolling stock, vehicles, ships and airplanes; - laboratory and meter test equipment; - reference standard meters; - data interfaces to the register of the meter; - matching sockets or racks used for installation of electricity metering equipment; - any additional functions provided in electrical energy meters. This document does not cover measures for the detection and prevention of fraudulent attempts to compromise meter’s performance (tampering). [...]
- Standard29 pagesEnglish languagee-Library read for
This document specifies requirements and tests for the construction, performance, safety and production of battery powered class 1,5 Capillary Thermal-Mass Flow sensor gas meters (hereinafter referred to as meter(s)). This applies to meters having co-axial single pipe, or two pipe connections, which are used to measure volumes of fuel gases of the 2nd and/or 3rd family, as given in EN 437:2021.
In general, the term "thermal mass flow meters" applies to a flow-measuring device using heat transfer to measure and indicate gas flowrate, as defined in ISO 14511.
NOTE Although the word "mass" is present in the definition of the measurement principle, gas meters covered by this document provide measurement of gas at base conditions of temperature and pressure.
These meters have a maximum working pressure not exceeding 0,5 bar and a maximum flowrate not exceeding 160 m3/h over a minimum ambient temperature range of −10 °C to +40 °C and a gas temperature range as specified in the marking, with a minimum range of 40 °C.
For meters designed for hydrogen measurement, the maximum flowrate is not exceeding 480 m3/h, whilst the other characteristics are as stated above.
This document applies to meters indicating volume at base conditions, which are installed in locations with vibration and shocks of low significance. It applies to meters in:
- closed locations (indoor or outdoor with protection, as specified in the instruction manual) with condensing humidity or with non-condensing humidity;
or, if specified in the marking:
- open locations (outdoor without any covering) both with condensing humidity or with non-condensing humidity;
and in locations with electromagnetic disturbances likely to be found in residential, commercial and light industrial use. For meters which indicate unconverted volume, reference can be made to Annex C.
Unless otherwise stated, all pressures given in this document are gauge pressures.
Requirements for electronic indexes, valves and additional requirements for batteries incorporated in the meter and any other additional functionalities are given in EN 16314:2013.
Unless otherwise stated in a particular test, the tests are carried out on meters that include additional functionality devices, as indicated in the instruction manual.
Clauses 1 to 13 are for design and type testing only.
For meters designed for blended gas and/or hydrogen measurement, refer to Annex E.
This document refers only to hydrogen as specified in ISO 14687:2025 with a purity of type I grade A or better.
Unless otherwise stated, all tests applicable to 2nd and 3rd family gases are applicable also to blended gas and hydrogen.
Mixtures with a hydrogen concentration above 20 % and below 98 % by volume are not covered by this document.
- Draft89 pagesEnglish languagee-Library read for
- Draft153 pagesEnglish languagee-Library read for
This European Standard specifies the requirements and tests for the construction, performance, safety and conformity of conversion devices used to determine the energy of fuel gases described in the Table 1, including those of the 1st and 2nd families according to EN 437.
The energy conversion device (ECD) considered in this standard consists of an energy calculator (EC) and is associated with the following devices and/or functions:
- a volume conversion device (VCD) or a flow computer used as gas meter conversion, either conforming to EN 12405-1, or to prEN 12405-3, for high accuracy measurements;
- a calorific value determination device (CVDD).
Requirements for type approval tests of the devices, not included in the above-mentioned standards are described in appropriate annexes specified in Table 6.
For the purpose of this European Standard, the term "volume conversion devices" (VCDs) includes flow computers (FCs).
A single calculator may undertake the volume conversion functions for different metering lines.
- Draft80 pagesEnglish languagee-Library read for
This part of IEC 62052 specifies requirements and associated tests, with their appropriate conditions for type testing of AC and DC electricity meters. This document details functional, mechanical, electrical and marking requirements, test methods, and test conditions, including immunity to external influences covering electromagnetic and climatic environments.
- Draft32 pagesEnglish languagee-Library read for
Particular requirements for static meters intended for residential, commercial and light industrial use, of class indexes A, B and C, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies performance requirements and type test methods.
- Draft9 pagesEnglish languagee-Library read for
Particular requirements for static meters intended for residential, commercial and light industrial use, of class indexes A, B and C, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies performance requirements and type test methods.
- Draft9 pagesEnglish languagee-Library read for
This part of IEC 62052 specifies requirements and associated tests, with their appropriate conditions for type testing of AC and DC electricity meters. This document details functional, mechanical, electrical and marking requirements, test methods, and test conditions, including immunity to external influences covering electromagnetic and climatic environments.
- Draft32 pagesEnglish languagee-Library read for
- Draft153 pagesEnglish languagee-Library read for
This document specifies requirements and tests for the construction, performance, safety and production of battery powered class 1,5 Capillary Thermal-Mass Flow sensor gas meters (hereinafter referred to as meter(s)). This applies to meters having co-axial single pipe, or two pipe connections, which are used to measure volumes of fuel gases of the 2nd and/or 3rd family, as given in EN 437:2021.
In general, the term "thermal mass flow meters" applies to a flow-measuring device using heat transfer to measure and indicate gas flowrate, as defined in ISO 14511.
NOTE Although the word "mass" is present in the definition of the measurement principle, gas meters covered by this document provide measurement of gas at base conditions of temperature and pressure.
These meters have a maximum working pressure not exceeding 0,5 bar and a maximum flowrate not exceeding 160 m3/h over a minimum ambient temperature range of −10 °C to +40 °C and a gas temperature range as specified in the marking, with a minimum range of 40 °C.
For meters designed for hydrogen measurement, the maximum flowrate is not exceeding 480 m3/h, whilst the other characteristics are as stated above.
This document applies to meters indicating volume at base conditions, which are installed in locations with vibration and shocks of low significance. It applies to meters in:
- closed locations (indoor or outdoor with protection, as specified in the instruction manual) with condensing humidity or with non-condensing humidity;
or, if specified in the marking:
- open locations (outdoor without any covering) both with condensing humidity or with non-condensing humidity;
and in locations with electromagnetic disturbances likely to be found in residential, commercial and light industrial use. For meters which indicate unconverted volume, reference can be made to Annex C.
Unless otherwise stated, all pressures given in this document are gauge pressures.
Requirements for electronic indexes, valves and additional requirements for batteries incorporated in the meter and any other additional functionalities are given in EN 16314:2013.
Unless otherwise stated in a particular test, the tests are carried out on meters that include additional functionality devices, as indicated in the instruction manual.
Clauses 1 to 13 are for design and type testing only.
For meters designed for blended gas and/or hydrogen measurement, refer to Annex E.
This document refers only to hydrogen as specified in ISO 14687:2025 with a purity of type I grade A or better.
Unless otherwise stated, all tests applicable to 2nd and 3rd family gases are applicable also to blended gas and hydrogen.
Mixtures with a hydrogen concentration above 20 % and below 98 % by volume are not covered by this document.
- Draft89 pagesEnglish languagee-Library read for
This European Standard specifies the requirements and tests for the construction, performance, safety and conformity of conversion devices used to determine the energy of fuel gases described in the Table 1, including those of the 1st and 2nd families according to EN 437.
The energy conversion device (ECD) considered in this standard consists of an energy calculator (EC) and is associated with the following devices and/or functions:
- a volume conversion device (VCD) or a flow computer used as gas meter conversion, either conforming to EN 12405-1, or to prEN 12405-3, for high accuracy measurements;
- a calorific value determination device (CVDD).
Requirements for type approval tests of the devices, not included in the above-mentioned standards are described in appropriate annexes specified in Table 6.
For the purpose of this European Standard, the term "volume conversion devices" (VCDs) includes flow computers (FCs).
A single calculator may undertake the volume conversion functions for different metering lines.
- Draft80 pagesEnglish languagee-Library read for
This document specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the 2nd and/or 3rd family gases as given in EN 437:2021, at maximum working pressures not exceeding 0,5 bar )) and maximum actual flow rates of up to 40 m3/h over a minimum ambient temperature range of −10 °C to +40 °C, and minimum gas temperature span of 40 K. This document applies to meters where the measuring element and the register(s) are enclosed in the same case.
This document applies to meters with and without built-in temperature conversion, that are installed in locations with vibration and shocks of low significance and in
- closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity;
or, if specified by the manufacturer;
- open locations (outdoor without any covering) both with condensing humidity or with non-condensing humidity;
and in locations with electromagnetic disturbances likely to be found in residential, commercial and light industrial use.
Unless otherwise stated, all pressures given in this document are gauge pressures.
Clauses 1 to 14 are for design and type testing only.
Requirements for electronic indexes, batteries, valves incorporated in the meter and other additional functionalities are given in EN 16314:2013
Unless otherwise stated in a particular test, the tests are carried out on meters that include additional functionality devices intended by the manufacturer.
When more than one meter type is submitted for testing, then each meter type needs to be tested against this document.
- Draft92 pagesEnglish languagee-Library read for
This document specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the 2nd and/or 3rd family gases as given in EN 437:2021, at maximum working pressures not exceeding 0,5 bar )) and maximum actual flow rates of up to 40 m3/h over a minimum ambient temperature range of −10 °C to +40 °C, and minimum gas temperature span of 40 K. This document applies to meters where the measuring element and the register(s) are enclosed in the same case.
This document applies to meters with and without built-in temperature conversion, that are installed in locations with vibration and shocks of low significance and in
- closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity;
or, if specified by the manufacturer;
- open locations (outdoor without any covering) both with condensing humidity or with non-condensing humidity;
and in locations with electromagnetic disturbances likely to be found in residential, commercial and light industrial use.
Unless otherwise stated, all pressures given in this document are gauge pressures.
Clauses 1 to 14 are for design and type testing only.
Requirements for electronic indexes, batteries, valves incorporated in the meter and other additional functionalities are given in EN 16314:2013
Unless otherwise stated in a particular test, the tests are carried out on meters that include additional functionality devices intended by the manufacturer.
When more than one meter type is submitted for testing, then each meter type needs to be tested against this document.
- Draft92 pagesEnglish languagee-Library read for
Frequently Asked Questions
A European Standardization Mandate is a formal request from the European Commission to the European Standardization Organizations (CEN, CENELEC, and ETSI) to develop European standards (ENs) in support of EU legislation and policies. Mandates are issued under Regulation (EU) No 1025/2012 and help ensure that products and services meet the essential requirements set out in EU directives and regulations.
M/626 is a European Standardization Mandate titled "COMMISSION IMPLEMENTING DECISION of 28.7.2026 on a standardisation request to the European Committee for Standardization, to the European Committee for Electrotechnical Standardization and to the European Telecommunications Standards Institute as regards certain measuring instruments in support of Directive 2014/32/EU of the European Parliament and of the Council". COMMISSION IMPLEMENTING DECISION of 28.7.2026 on a standardisation request to the European Committee for Standardization, to the European Committee for Electrotechnical Standardization and to the European Telecommunications Standards Institute as regards certain measuring instruments in support of Directive 2014/32/EU of the European Parliament and of the Council There are 20 standards developed under this mandate.
Standards developed in response to a mandate and cited in the Official Journal of the European Union become "harmonized standards". Products manufactured in compliance with harmonized standards benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation, facilitating CE marking and market access across the European Economic Area.