This document applies to hearing aid fitting management (HAFM) services offered by hearing aid professionals (HAP) when providing benefit for their clients. The provision of hearing aids relies on the knowledge and practices of a hearing aid professional, to ensure the proper fitting and adequate service in the interest of the client with hearing loss. This document specifies general processes of HAFM from the client profile to the follow-up through administering, organising and controlling hearing aid fitting through all stages. It also specifies important preconditions such as education, facilities and systems that are required to ensure proper services. The focus of this document is the services offered to the majority of adult clients with hearing impairment. It is recognized that certain populations with hearing loss such as children, persons with other disabilities or persons with implantable devices can require services outside the scope of this document. This document generally applies to air conduction hearing aids and for the most part also to bone conduction devices. Hearing loss can be a consequence of serious medical conditions. Hearing aid professionals are not in a position to diagnose or treat such conditions. When assisting clients seeking hearing rehabilitation without prior medical examination, hearing aid professionals are expected to be observant of symptoms of such conditions and refer to proper medical care. Further to the main body of the document, which specifies the HAFM requirements and processes, several informative annexes are provided. Appropriate education of hearing aid professionals is vital for exercising HAFM. Annex A defines the competencies required for the HAFM processes. Annex B offers a recommended curriculum for the education of hearing aid professionals. Annex C is an example of an appropriate fitting room. Annex D gives guidance on the referral of clients for medical or other specialist examination and treatment. Annex E is a recommendation for important information to be exchanged with the client during the process of HAFM. Annex F is a comprehensive terminology list offering definitions of the most current terms related to HAFM. It is the intention that these annexes be helpful to those who wish to deliver HAFM of the highest quality.

  • Standard
    42 pages
    English language
    sale 15% off
  • Standard
    46 pages
    French language
    sale 15% off

Addition:
This document specifies the determination of airborne acoustical noise of mains operated and cordless dry vacuum cleaners including their accessories and docking stations for household use or under conditions similar to those in households.
For wet and dry vacuum cleaners, the dry cleaning function applies. The wet cleaning function is measured in accordance with IEC 60704-2-20.
NOTE 101 Particular requirements for floor cleaning robots are specified in IEC 60704-2-171.
This document describes the determination of the noise emission of dry vacuum cleaners under normal operating conditions on carpet and hard floor in accordance with IEC 62885-2:—,4.62.

  • Standard
    24 pages
    English language
    e-Library read for
    ×1 day

Addition:
This document specifies the determination of airborne acoustical noise of mains operated and cordless dry vacuum cleaners including their accessories and docking stations for household use or under conditions similar to those in households.
For wet and dry vacuum cleaners, the dry cleaning function applies. The wet cleaning function is measured in accordance with IEC 60704-2-20.
NOTE 101 Particular requirements for floor cleaning robots are specified in IEC 60704-2-171.
This document describes the determination of the noise emission of dry vacuum cleaners under normal operating conditions on carpet and hard floor in accordance with IEC 62885-2:—,4.62.

  • Standard
    24 pages
    English language
    e-Library read for
    ×1 day

This document specifies the measurement of the determination of the static airflow resistance (see also References[1]and2) in a laminar flow regime, of porous materials for acoustical applications.

  • Standard
    16 pages
    English language
    e-Library read for
    ×1 day
  • Standard
    6 pages
    English and French language
    sale 15% off
  • Standard
    6 pages
    English and French language
    sale 15% off

IEC 606045-6:2022 applies to instruments designed primarily for the measurement of otoacoustic emissions in the human external auditory meatus evoked by acoustic probe stimuli. This document defines the characteristics to be specified by the manufacturer, specifies minimum mandatory functions for two types of instruments and provides performance specifications applicable to both instrument types. This document describes methods to be used to demonstrate conformance with the specifications in this document and guidance on methods for periodic calibration. The purpose of this document is to ensure that measurements made under comparable test conditions with different instruments complying with this document will be consistent. Instruments can provide a measurement function not specifically within the scope of this document and still comply with the relevant requirements of this document for the functions that are within the scope. This document is not intended to restrict development or incorporation of new features, nor to discourage innovative approaches. IEC 606045-6:2022 cancels and replaces the first edition published in 2009. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the nominal test frequency used in DPOAE is now defined as the higher of the two frequencies, f2;
b) the permitted deviation of the stimulus signal for TEOAE has been specified;
c) the frequency range for DPOAE stimulus signals has been redefined,
d) the stimulus level requirements for TEOAE have been redefined;
e) the stimulus level requirements for DPOAE have been redefined;
f) the harmonic distortion requirements for DPOAE have been redefined;
g) a minimum measurement range for DPOAE has been added.

  • Standard
    54 pages
    English language
    sale 15% off
  • Standard
    32 pages
    English language
    sale 15% off
  • Standard
    34 pages
    English and French language
    sale 15% off

1.1        General
This document specifies methods for determining the sound power level of a noise source from sound pressure levels measured on a surface enveloping the noise source (machinery or equipment) in an environment that approximates to an acoustic free field near one or more reflecting planes. The sound power level produced by the noise source, in frequency bands or with A-weighting applied, is calculated using those measurements.
NOTE   Differently shaped measurement surfaces can yield differing estimates of the sound power level of a given noise source which are accounted for in the uncertainty associated with this test method. An appropriately drafted noise test code (see ISO 12001) gives detailed information on the selection of the surface.
1.2        Types of noise and noise sources
The methods specified in this document are suitable for all types of noise (steady, non-steady, and fluctuating) as defined in ISO 12001, except for short duration, impulsive events.
This document is applicable to all types and sizes of noise source (e.g. stationary or slowly moving component or sub-assembly), provided that the conditions for the measurements can be met.
NOTE   It is possible that the conditions for measurements given in this document are impracticable for very tall or very long sources such as chimneys, ducts, conveyors and multi-source industrial plants. A noise test code for the determination of noise emission of specific sources can provide alternative methods in such cases.
1.3        Test environment
The test environments that are applicable for measurements made in accordance with this document can be located indoors or outdoors, with one or more sound-reflecting planes present on or near which the noise source under test is mounted. The ideal environment is a completely open space with no bounding or reflecting surfaces other than the reflecting plane(s), such as that provided by a qualified hemi-anechoic chamber, but procedures are given for applying corrections (within limits that are specified) in the case of environments that are less than ideal. Annex A or ISO 26101-2 specifies methods for determining the adequacy of the test environment and for determination of corrections to be applied to account for the effect of the test environment.
1.4        Measurement uncertainty
Information is given on the uncertainty of the sound power levels determined in accordance with this document, for measurements made in limited bands of frequency and with frequency A-weighting applied. Annex I specifies procedures for testing laboratories that can be used to reduce measurement uncertainty. The uncertainty conforms to ISO 12001, accuracy grade 2 (engineering grade). General information on measurement uncertainty is provided in this document and additional information can be found in ISO 5114-1[8].

  • Standard
    74 pages
    English language
    e-Library read for
    ×1 day

IEC 60704-2-1:2026 specifies the determination of airborne acoustical noise of mains operated and cordless dry vacuum cleaners including their accessories and docking stations for household use or under conditions similar to those in households. For wet and dry vacuum cleaners, the dry cleaning function applies. The wet cleaning function is measured in accordance with IEC 60704-2-20. Particular requirements for floor cleaning robots are specified in IEC 60704-2-17 . This document describes the determination of the noise emission of dry vacuum cleaners under normal operating conditions on carpet and hard floor in accordance with IEC 62885-2. This fifth edition cancels and replaces the fourth edition published in 2020. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with IEC 60704 1:2021;
b) addressing consumer relevant testing aspects;
c) robustness of standards and closing potential loopholes
d) enlarged scope to include noise measurement on docking stations.
This document is intended to be used in conjunction with IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.

  • Standard
    59 pages
    English language
    sale 15% off
  • Standard
    41 pages
    English and French language
    sale 15% off
  • Standard
    41 pages
    English and French language
    sale 15% off

This document specifies the measurement of the determination of the static airflow resistance (see also References[1]and2) in a laminar flow regime, of porous materials for acoustical applications.

  • Standard
    16 pages
    English language
    e-Library read for
    ×1 day

This document specifies the measurement of the determination of the static airflow resistance (see also References[1]and2) in a laminar flow regime, of porous materials for acoustical applications.

  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off

This document specifies a normalized railway noise spectrum for the evaluation and assessment of the acoustic performance of devices designed to reduce airborne railway noise near railways.
All noise reducing devices different from noise barriers and related devices acting on airborne sound propagation, e.g. devices for attenuation of ground borne vibration and on board devices are outside of the scope of this document.

  • Standard
    20 pages
    English language
    e-Library read for
    ×1 day

IEC 60704-2-20:2026 specifies the determination of airborne acoustical noise of mains operated and cordless wet hard floor cleaning appliances for household or similar use. In the case of appliances with combined functionality, this document only addresses the wet cleaning functionality. This document does not apply to wet hard floor cleaning appliances for industrial or professional purposes and robotic wet hard floor cleaning appliances. This document is not intended for cleaning appliances according to IEC 60335-2-79, IEC 60704-2-1, IEC 60704-2-17. This document describes the determination of the noise emission of wet hard floor cleaners under normal operating conditions on hard floor in accordance with 4.6 of IEC/ASTM 62885-6:2023. For determining and verifying noise emission values declared in product specifications, see IEC 60704-3. This document is intended to be used in conjunction with IEC 60704 1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.

  • Standard
    20 pages
    English language
    e-Library read for
    ×1 day

IEC 60704-2-19:2026 applies to stationary freestanding and wall-mounted air cleaners for domestic and similar use, supplied from mains, d.c. voltage not exceeding 48 V or batteries. This document includes combination products, where air cleaning is combined with for example humidification, but can be used only for the air cleaning function.
This Part 2-19 is intended to be used in conjunction with IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.

  • Standard
    16 pages
    English language
    e-Library read for
    ×1 day

IEC 60704-2-20:2026 specifies the determination of airborne acoustical noise of mains operated and cordless wet hard floor cleaning appliances for household or similar use. In the case of appliances with combined functionality, this document only addresses the wet cleaning functionality. This document does not apply to wet hard floor cleaning appliances for industrial or professional purposes and robotic wet hard floor cleaning appliances. This document is not intended for cleaning appliances according to IEC 60335-2-79, IEC 60704-2-1, IEC 60704-2-17. This document describes the determination of the noise emission of wet hard floor cleaners under normal operating conditions on hard floor in accordance with 4.6 of IEC/ASTM 62885-6:2023. For determining and verifying noise emission values declared in product specifications, see IEC 60704-3. This document is intended to be used in conjunction with IEC 60704 1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.

  • Standard
    20 pages
    English language
    e-Library read for
    ×1 day

This document specifies a method for determining the sound power level of a fan. This document is applicable to fans as defined in ISO 13349-1. The applicability of this document is limited to the determination of airborne sound emission for the specified set-ups. Vibration is not measured, nor is the sensitivity of airborne sound emission to vibration effects determined. The sizes of fan which can be tested in accordance with this document are limited only by the practical aspects of the test set-up. Dimensional limitations, test fan dimensions, and air performance will control the room size, power and mounting requirements for the test fan. NOTE Small fans can be tested according to this document or to ISO 10302-1, according to usage. The test arrangements in this document establish the laboratory conditions necessary for a successful test. Rarely will it be possible to meet these requirements in situ and this document is not intended for field measurements. NOTE Intending users are reminded that, in these situations, there can be additional acoustic system effects where inlet and outlet conditions at the fan are less than ideal. The enveloping surface methods can be used for the determination of open inlet and/or open outlet sound power level of fans for the standardized installation categories given in 4.1. An estimation (with increased uncertainty) of ducted sound power for fans too small, or otherwise inconvenient, for testing by the in-duct method described in ISO 5136 can also be obtained by the addition of end reflection corrections (see ISO 13347-1:2025, Annex C).

  • Standard
    20 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off

IEC 60704-2-19:2026 applies to stationary freestanding and wall-mounted air cleaners for domestic and similar use, supplied from mains, d.c. voltage not exceeding 48 V or batteries. This document includes combination products, where air cleaning is combined with for example humidification, but can be used only for the air cleaning function. This Part 2-19 is intended to be used in conjunction with IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.

  • Standard
    16 pages
    English language
    e-Library read for
    ×1 day

1.1        General
This document specifies methods for determining the sound power level of a noise source from sound pressure levels measured on a surface enveloping the noise source (machinery or equipment) in an environment that approximates to an acoustic free field near one or more reflecting planes. The sound power level produced by the noise source, in frequency bands or with A-weighting applied, is calculated using those measurements.
NOTE   Differently shaped measurement surfaces can yield differing estimates of the sound power level of a given noise source which are accounted for in the uncertainty associated with this test method. An appropriately drafted noise test code (see ISO 12001) gives detailed information on the selection of the surface.
1.2        Types of noise and noise sources
The methods specified in this document are suitable for all types of noise (steady, non-steady, and fluctuating) as defined in ISO 12001, except for short duration, impulsive events.
This document is applicable to all types and sizes of noise source (e.g. stationary or slowly moving component or sub-assembly), provided that the conditions for the measurements can be met.
NOTE   It is possible that the conditions for measurements given in this document are impracticable for very tall or very long sources such as chimneys, ducts, conveyors and multi-source industrial plants. A noise test code for the determination of noise emission of specific sources can provide alternative methods in such cases.
1.3        Test environment
The test environments that are applicable for measurements made in accordance with this document can be located indoors or outdoors, with one or more sound-reflecting planes present on or near which the noise source under test is mounted. The ideal environment is a completely open space with no bounding or reflecting surfaces other than the reflecting plane(s), such as that provided by a qualified hemi-anechoic chamber, but procedures are given for applying corrections (within limits that are specified) in the case of environments that are less than ideal. Annex A or ISO 26101-2 specifies methods for determining the adequacy of the test environment and for determination of corrections to be applied to account for the effect of the test environment.
1.4        Measurement uncertainty
Information is given on the uncertainty of the sound power levels determined in accordance with this document, for measurements made in limited bands of frequency and with frequency A-weighting applied. Annex I specifies procedures for testing laboratories that can be used to reduce measurement uncertainty. The uncertainty conforms to ISO 12001, accuracy grade 2 (engineering grade). General information on measurement uncertainty is provided in this document and additional information can be found in ISO 5114-1[8].

  • Standard
    74 pages
    English language
    e-Library read for
    ×1 day

IEC 62127-3:2022 specifies relevant hydrophone characteristics. This document is applicable to:
- hydrophones employing piezoelectric sensor elements, designed to measure the pulsed and continuous wave ultrasonic fields generated by ultrasonic equipment;
- hydrophones used for measurements made in water;
- hydrophones with or without an associated pre-amplifier.
IEC 62127-3:2022 cancels and replaces the first edition published in 2007 and Amendment 1:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) The upper frequency limit of 40 MHz has been removed.
b) Hydrophone sensitivity definitions have been changed to recognize sensitivities as complex-valued quantities.
c) Procedures to determine the effective hydrophone size have been changed according to the rationale outlined in Annex B.
d) Requirements on the frequencies for which the effective hydrophone size shall be provided have been changed to achieve practicality for increased frequency bands.
e) The new Annex B and Annex C have been added.
f) Annex A has been updated to reflect the changes of the normative parts.

  • Standard
    96 pages
    English language
    sale 15% off
  • Standard
    62 pages
    English language
    sale 15% off
  • Standard
    62 pages
    English and French language
    sale 15% off
  • Standard
    6 pages
    English language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off
  • Standard
    13 pages
    English and French language
    sale 15% off

IEC 60704-2-20:2026 specifies the determination of airborne acoustical noise of mains operated and cordless wet hard floor cleaning appliances for household or similar use. In the case of appliances with combined functionality, this document only addresses the wet cleaning functionality. This document does not apply to wet hard floor cleaning appliances for industrial or professional purposes and robotic wet hard floor cleaning appliances. This document is not intended for cleaning appliances according to IEC 60335-2-79, IEC 60704-2-1, IEC 60704-2-17. This document describes the determination of the noise emission of wet hard floor cleaners under normal operating conditions on hard floor in accordance with 4.6 of IEC/ASTM 62885-6:2023. For determining and verifying noise emission values declared in product specifications, see IEC 60704-3. This document is intended to be used in conjunction with IEC 60704 1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.

  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    69 pages
    English language
    sale 15% off
  • Standard
    17 pages
    French language
    sale 15% off
  • Standard
    33 pages
    English and French language
    sale 15% off

IEC 61252:2025 specifies
– performance specifications for personal sound exposure meters,
– details of the tests necessary to verify conformance to all mandatory specifications for the purpose of pattern evaluation, and
– procedures for periodic testing of a personal sound exposure meter.
Personal sound exposure meters conforming to the requirements of this document have a specified frequency response for sound incident on the microphone from all directions.
This document is applicable to instruments that are designed to be worn on a person in a configuration specified by the manufacturer for the measurement of sound immission resulting from steady, intermittent, fluctuating, irregular, or impulsive sounds. For reproducibility of results, specifications and tests for the response to sound waves apply without an operator present in the sound field.
Pattern evaluation tests and periodic tests described in this this document apply to personal sound exposure meters for which the manufacturer claims conformance to the specifications given in this document.
IEC 61252:2025 cancels and replaces the first edition published in 1993, Amendment 1:2000, and Amendment 2:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) personal sound exposure meters are required to provide indications of time-averaged sound level and peak sound level;
b) sound exposure is an optional quantity for indication;
c) specifications for physical quantities that do not follow the principle of equal-energy exchange rate have been added;
d) specifications for directional response have been added;
e) specifications for frequency weightings apply to the relative diffuse-field frequency response;
f) determination of conformance to specifications takes account of uncertainties of measurement;
g) detailed requirements for pattern-evaluation tests and periodic testing have been added.

  • Standard
    54 pages
    English language
    e-Library read for
    ×1 day

IEC 60704-2-19:2026 applies to stationary freestanding and wall-mounted air cleaners for domestic and similar use, supplied from mains, d.c. voltage not exceeding 48 V or batteries. This document includes combination products, where air cleaning is combined with for example humidification, but can be used only for the air cleaning function.
This Part 2-19 is intended to be used in conjunction with IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    55 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off
  • Standard
    24 pages
    English and French language
    sale 15% off

This document specifies the procedure for measuring the capacity of a high-speed or medium-speed engine to generate vibration and the determination of the frequency limits of validity of the information quoted. The method described in this document is not suitable for low-speed engines. This document describes an engineering and not a precision method. Whether the tests are carried out on the test bed or on site will be agreed between the user and the manufacturer. This document is applicable to high-speed and medium-speed reciprocating internal combustion engines for land, rail traction and marine use; this document is not applicable to engines used to propel agricultural tractors, road vehicles and aircraft. This document can also be applied to engines used to propel road-construction and earth-moving machines, industrial trucks and for other applications with engines where no suitable International Standard exists.

  • Standard
    22 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off

This document specifies a test method for measuring a quantity representative of the intrinsic characteristics of airborne sound insulation for road traffic noise reducing devices: the sound insulation index.
This document is applicable to:
—   determination of the intrinsic characteristics of airborne sound insulation of noise reducing devices to be installed along roads, to be measured either on typical installations alongside roads or in laboratory conditions;
—   determination of the intrinsic characteristics of airborne sound insulation of road traffic noise reducing devices in actual use;
—   comparison of design specifications with actual performance data after the completion of the construction work;
—   verification of the long-term performance of road traffic noise reducing devices (with a repeated application of the method);
—   interactive design process of new products, including the formulation of installation manuals.
This document does not apply to:
—   the determination of the intrinsic characteristics of airborne sound insulation of road traffic noise reducing devices to be installed in reverberant conditions, e.g. inside tunnels or deep trenches or under covers.
Results for the sound insulation index are expressed as a function of frequency in one-third octave bands, between 200 Hz and 5 kHz for qualification purposes. If it is not possible to get valid measurement results over the whole frequency range indicated, the results are given in a restricted frequency range and the reasons for the restriction(s) are clearly reported.
For indoor measurements, see Annex D.

  • Standard
    60 pages
    English language
    e-Library read for
    ×1 day

This document specifies a test method for determining the intrinsic characteristics of sound diffraction of added devices installed on the top of road traffic noise reducing devices. The test method prescribes measurements of the sound pressure level at several reference points near the top edge of a road traffic noise reducing device with and without the added device installed on its top. The effectiveness of the added device is calculated as the difference between the measured values with and without the added devices, correcting for any change in height (the method specified gives the acoustic benefit over a simple barrier of the same height; however, in practice the added device can raise the height and this could provide additional screening depending on the source and receiver positions).
This document is applicable to:
—   the preliminary qualification, outdoors or indoors, of added devices to be installed on road traffic noise reducing devices;
—   the determination of sound diffraction index difference of added devices in actual use;
—   the comparison of design specifications with actual performance data after the completion of the construction work;
—   the verification of the long-term performance of added devices (with a repeated application of the method);
—   the interactive design process of new products, including the formulation of installation manuals.
The test method can be applied both in situ and on samples purposely built to be tested using the method described here.
Results are expressed as a function of frequency, in one-third octave bands between 100 Hz and 5 kHz. If it is not possible to get valid measurements results over the whole frequency range indicated, the results are given in the restricted frequency range and the reasons of the restriction(s) are clearly reported. A single-number rating is calculated from frequency data.
For indoor measurements, see Annex D.

  • Standard
    49 pages
    English language
    e-Library read for
    ×1 day

This document specifies a normalized traffic noise spectrum for the evaluation and assessment of the acoustic performance of devices designed to reduce traffic noise near roads.

  • Standard
    7 pages
    English language
    e-Library read for
    ×1 day

This document specifies the laboratory method for measuring the airborne sound insulation performance of road traffic noise reducing devices in reverberant conditions. It covers the assessment of the intrinsic performance of barriers that can reasonably be assembled inside the testing facility described in EN ISO 10140-2 and EN ISO 10140-4.
This method is not intended for the determination of the intrinsic characteristics of airborne sound insulation of noise reducing devices to be installed on roads in non-reverberant conditions.

  • Standard
    22 pages
    English language
    e-Library read for
    ×1 day

This document specifies the laboratory method for measuring the sound absorption performance of road traffic noise reducing devices in reverberant conditions. It covers the assessment of the intrinsic sound absorption performance of devices that can reasonably be assembled inside the testing facility described in EN ISO 354.
This method is not intended for the determination of the intrinsic characteristics of sound absorption of noise reducing devices to be installed on roads in non-reverberant conditions.
The test method in EN ISO 354 referred to in this document excludes devices that act as weakly damped resonators. Some devices will depart significantly from these requirements and in these cases, care is needed in interpreting the results.

  • Standard
    30 pages
    English language
    e-Library read for
    ×1 day

This document specifies a test method for measuring a quantity representative of the intrinsic characteristics of sound reflection from road noise reducing devices, the sound reflection index, and then calculate a single-number rating for sound absorption from it.
This document is applicable to:
—   the determination of the intrinsic characteristics of sound absorption of noise reducing devices to be installed along roads, to be measured either on typical installations alongside roads or on a relevant test specimen section;
—   the determination of the intrinsic characteristics of sound absorption of road traffic noise reducing devices in actual use under direct sound field conditions;
—   the comparison of design specifications with actual performance data after the completion of the construction work;
—   the verification of the long-term performance of road traffic noise reducing devices (with a repeated application of the method).
This document does not apply to:
—   the determination of the intrinsic characteristics of sound absorption of road traffic noise reducing devices to be installed in reverberant conditions, e.g. inside tunnels or deep trenches.
Results for the sound reflection index are expressed as a function of frequency, in one-third octave bands between 200 Hz and 5 kHz, for qualification purposes. If it is not possible to get valid measurement results over the whole frequency range indicated, the results are given in a restricted frequency range, and the reasons for the restriction(s) are clearly reported.
For indoor measurements, see Annex D.

  • Standard
    73 pages
    English language
    e-Library read for
    ×1 day

This document specifies a test method for measuring a quantity representative of the intrinsic characteristics of airborne sound insulation for road traffic noise reducing devices: the sound insulation index.
This document is applicable to:
—   determination of the intrinsic characteristics of airborne sound insulation of noise reducing devices to be installed along roads, to be measured either on typical installations alongside roads or in laboratory conditions;
—   determination of the intrinsic characteristics of airborne sound insulation of road traffic noise reducing devices in actual use;
—   comparison of design specifications with actual performance data after the completion of the construction work;
—   verification of the long-term performance of road traffic noise reducing devices (with a repeated application of the method);
—   interactive design process of new products, including the formulation of installation manuals.
This document does not apply to:
—   the determination of the intrinsic characteristics of airborne sound insulation of road traffic noise reducing devices to be installed in reverberant conditions, e.g. inside tunnels or deep trenches or under covers.
Results for the sound insulation index are expressed as a function of frequency in one-third octave bands, between 200 Hz and 5 kHz for qualification purposes. If it is not possible to get valid measurement results over the whole frequency range indicated, the results are given in a restricted frequency range and the reasons for the restriction(s) are clearly reported.
For indoor measurements, see Annex D.

  • Standard
    60 pages
    English language
    e-Library read for
    ×1 day

This document specifies the laboratory method for measuring the sound absorption performance of road traffic noise reducing devices in reverberant conditions. It covers the assessment of the intrinsic sound absorption performance of devices that can reasonably be assembled inside the testing facility described in EN ISO 354.
This method is not intended for the determination of the intrinsic characteristics of sound absorption of noise reducing devices to be installed on roads in non-reverberant conditions.
The test method in EN ISO 354 referred to in this document excludes devices that act as weakly damped resonators. Some devices will depart significantly from these requirements and in these cases, care is needed in interpreting the results.

  • Standard
    30 pages
    English language
    e-Library read for
    ×1 day

This document specifies a test method for measuring a quantity representative of the intrinsic characteristics of sound reflection from road noise reducing devices, the sound reflection index, and then calculate a single-number rating for sound absorption from it.
This document is applicable to:
—   the determination of the intrinsic characteristics of sound absorption of noise reducing devices to be installed along roads, to be measured either on typical installations alongside roads or on a relevant test specimen section;
—   the determination of the intrinsic characteristics of sound absorption of road traffic noise reducing devices in actual use under direct sound field conditions;
—   the comparison of design specifications with actual performance data after the completion of the construction work;
—   the verification of the long-term performance of road traffic noise reducing devices (with a repeated application of the method).
This document does not apply to:
—   the determination of the intrinsic characteristics of sound absorption of road traffic noise reducing devices to be installed in reverberant conditions, e.g. inside tunnels or deep trenches.
Results for the sound reflection index are expressed as a function of frequency, in one-third octave bands between 200 Hz and 5 kHz, for qualification purposes. If it is not possible to get valid measurement results over the whole frequency range indicated, the results are given in a restricted frequency range, and the reasons for the restriction(s) are clearly reported.
For indoor measurements, see Annex D.

  • Standard
    73 pages
    English language
    e-Library read for
    ×1 day

This document specifies a normalized traffic noise spectrum for the evaluation and assessment of the acoustic performance of devices designed to reduce traffic noise near roads.

  • Standard
    7 pages
    English language
    e-Library read for
    ×1 day

This document specifies the laboratory method for measuring the airborne sound insulation performance of road traffic noise reducing devices in reverberant conditions. It covers the assessment of the intrinsic performance of barriers that can reasonably be assembled inside the testing facility described in EN ISO 10140-2 and EN ISO 10140-4.
This method is not intended for the determination of the intrinsic characteristics of airborne sound insulation of noise reducing devices to be installed on roads in non-reverberant conditions.

  • Standard
    22 pages
    English language
    e-Library read for
    ×1 day

This document specifies a test method for determining the intrinsic characteristics of sound diffraction of added devices installed on the top of road traffic noise reducing devices. The test method prescribes measurements of the sound pressure level at several reference points near the top edge of a road traffic noise reducing device with and without the added device installed on its top. The effectiveness of the added device is calculated as the difference between the measured values with and without the added devices, correcting for any change in height (the method specified gives the acoustic benefit over a simple barrier of the same height; however, in practice the added device can raise the height and this could provide additional screening depending on the source and receiver positions).
This document is applicable to:
—   the preliminary qualification, outdoors or indoors, of added devices to be installed on road traffic noise reducing devices;
—   the determination of sound diffraction index difference of added devices in actual use;
—   the comparison of design specifications with actual performance data after the completion of the construction work;
—   the verification of the long-term performance of added devices (with a repeated application of the method);
—   the interactive design process of new products, including the formulation of installation manuals.
The test method can be applied both in situ and on samples purposely built to be tested using the method described here.
Results are expressed as a function of frequency, in one-third octave bands between 100 Hz and 5 kHz. If it is not possible to get valid measurements results over the whole frequency range indicated, the results are given in the restricted frequency range and the reasons of the restriction(s) are clearly reported. A single-number rating is calculated from frequency data.
For indoor measurements, see Annex D.

  • Standard
    49 pages
    English language
    e-Library read for
    ×1 day

1.1 General This document specifies methods for determining the sound power level of a noise source from sound pressure levels measured on a surface enveloping the noise source (machinery or equipment) in an environment that approximates to an acoustic free field near one or more reflecting planes. The sound power level produced by the noise source, in frequency bands or with A-weighting applied, is calculated using those measurements. NOTE Differently shaped measurement surfaces can yield differing estimates of the sound power level of a given noise source which are accounted for in the uncertainty associated with this test method. An appropriately drafted noise test code (see ISO 12001) gives detailed information on the selection of the surface. 1.2 Types of noise and noise sources The methods specified in this document are suitable for all types of noise (steady, non-steady, and fluctuating) as defined in ISO 12001, except for short duration, impulsive events. This document is applicable to all types and sizes of noise source (e.g. stationary or slowly moving component or sub-assembly), provided that the conditions for the measurements can be met. NOTE It is possible that the conditions for measurements given in this document are impracticable for very tall or very long sources such as chimneys, ducts, conveyors and multi-source industrial plants. A noise test code for the determination of noise emission of specific sources can provide alternative methods in such cases. 1.3 Test environment The test environments that are applicable for measurements made in accordance with this document can be located indoors or outdoors, with one or more sound-reflecting planes present on or near which the noise source under test is mounted. The ideal environment is a completely open space with no bounding or reflecting surfaces other than the reflecting plane(s), such as that provided by a qualified hemi-anechoic chamber, but procedures are given for applying corrections (within limits that are specified) in the case of environments that are less than ideal. Annex A or ISO 26101-2 specifies methods for determining the adequacy of the test environment and for determination of corrections to be applied to account for the effect of the test environment. 1.4 Measurement uncertainty Information is given on the uncertainty of the sound power levels determined in accordance with this document, for measurements made in limited bands of frequency and with frequency A-weighting applied. Annex I specifies procedures for testing laboratories that can be used to reduce measurement uncertainty. The uncertainty conforms to ISO 12001, accuracy grade 2 (engineering grade). General information on measurement uncertainty is provided in this document and additional information can be found in ISO 5114-1[8].

  • Standard
    61 pages
    English language
    sale 15% off
  • Standard
    61 pages
    English language
    sale 15% off
  • Standard
    61 pages
    English language
    sale 15% off
  • Standard
    63 pages
    French language
    sale 15% off
  • Standard
    63 pages
    French language
    sale 15% off
  • Standard
    63 pages
    French language
    sale 15% off

This document defines the procedures for noise control of primarily open plants and the requirements on equipment suppliers for reporting and testing of noise. It is applicable to the following: — specification of procedures for noise control during engineering of a new plant and modification/extension of existing plants (construction and commissioning noise procedures are outside the scope of this document); — definition of responsibilities of parties involved, viz. “end-user”, “engineering contractor” and “equipment supplier”; — description of general procedures to arrive at noise requirements for individual equipment, based on overall noise requirements for the plant. Input to purchase specifications is presented in REF Annex_sec_A \r \h Annex A. A schematic flowchart, reviewing the noise control process, is presented in REF Annex_sec_B \r \h Annex B 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000C00000041006E006E00650078005F007300650063005F0042000000 and a summary of action items is presented in REF Annex_sec_C \r \h Annex C 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000C00000041006E006E00650078005F007300650063005F0043000000 . An example of an equipment noise data sheet is presented in REF Annex_sec_E \r \h Annex E 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000C00000041006E006E00650078005F007300650063005F0045000000 .

  • Standard
    29 pages
    English language
    sale 15% off

IEC 61252:2025 specifies – performance specifications for personal sound exposure meters, – details of the tests necessary to verify conformance to all mandatory specifications for the purpose of pattern evaluation, and – procedures for periodic testing of a personal sound exposure meter. Personal sound exposure meters conforming to the requirements of this document have a specified frequency response for sound incident on the microphone from all directions. This document is applicable to instruments that are designed to be worn on a person in a configuration specified by the manufacturer for the measurement of sound immission resulting from steady, intermittent, fluctuating, irregular, or impulsive sounds. For reproducibility of results, specifications and tests for the response to sound waves apply without an operator present in the sound field. Pattern evaluation tests and periodic tests described in this this document apply to personal sound exposure meters for which the manufacturer claims conformance to the specifications given in this document. IEC 61252:2025 cancels and replaces the first edition published in 1993, Amendment 1:2000, and Amendment 2:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) personal sound exposure meters are required to provide indications of time-averaged sound level and peak sound level; b) sound exposure is an optional quantity for indication; c) specifications for physical quantities that do not follow the principle of equal-energy exchange rate have been added; d) specifications for directional response have been added; e) specifications for frequency weightings apply to the relative diffuse-field frequency response; f) determination of conformance to specifications takes account of uncertainties of measurement; g) detailed requirements for pattern-evaluation tests and periodic testing have been added.

  • Standard
    54 pages
    English language
    e-Library read for
    ×1 day

This document specifies determining sound power levels of fans under standardized laboratory conditions from sound pressure levels measured in a reverberant room. This document is applicable for determination of the acoustic performance of fans. This document can additionally be applied to determine the acoustic performance of fans combined with an ancillary device, such as a roof cowl or damper or, where the fan is fitted with a silencer, the sound power resulting from the fan and silencer combination. For guidance of testing with ancillary items, see Annex C. This document applies to fans as defined in ISO 13349-1. It is limited to the determination of airborne sound emission for the specified set-ups. Vibration is not measured, nor is the sensitivity of airborne sound emission to vibration effects determined. This document is intended to be used in conjunction with ISO 5136, which covers the in-duct method, and ISO 10302-1 for small fans. The size of fans which can be tested in accordance with this document is limited only by the practical aspects of the test set-up. Test fan dimensions and air performance will control the room size. NOTE Based on usage, small fans can be tested according to this document or to ISO 10302-1. For reverberant field tests, the size of equipment under test is limited to less than 2 % of the room volume. For low power fans (up to 3 kW) that can be run from a domestic power supply (single phase AC at a voltage not exceeding 250 V and a current not exceeding 16 A), reference IEC 60704-2-7[18]. The test arrangements in this document establish the laboratory conditions necessary for a successful test. It is difficult to meet these requirements in situ and this document is not intended for field measurements. In these situations, users are reminded that the acoustic environment is unlikely to meet the specified conditions and there can be additional acoustic system effects where inlet and outlet conditions at the fan are less than ideal.

  • Standard
    22 pages
    English language
    sale 15% off
  • Standard
    23 pages
    French language
    sale 15% off

IEC 60645-7:2025 applies to instruments designed for the measurement of auditory evoked potentials from the inner ear, the auditory nerve, and the brainstem, evoked by either acoustic or vibratory stimuli of short duration. This document defines the characteristics to be specified by the manufacturer, specifies performance requirements for two types of instruments (screening and diagnostic/clinical), and specifies the functions to be provided on these types. It also specifies a means of describing the physical characteristics, in terms of electrical waveforms, of audiometric reference and test signals of short duration used with auditory evoked potential equipment and other equipment (e.g. otoacoustic emission instruments), and methods for their measurement. The purpose of this document is to ensure that measurements made under comparable test conditions with different instruments complying with this document will be consistent. This document is not intended to restrict development or incorporation of new features, nor to discourage innovative approaches. Evoked response measurement using the application of electric stimuli to a subject is beyond the scope of this document.

  • Standard
    24 pages
    English language
    e-Library read for
    ×1 day

IEC 61252:2025 specifies
– performance specifications for personal sound exposure meters,
– details of the tests necessary to verify conformance to all mandatory specifications for the purpose of pattern evaluation, and
– procedures for periodic testing of a personal sound exposure meter.
Personal sound exposure meters conforming to the requirements of this document have a specified frequency response for sound incident on the microphone from all directions.
This document is applicable to instruments that are designed to be worn on a person in a configuration specified by the manufacturer for the measurement of sound immission resulting from steady, intermittent, fluctuating, irregular, or impulsive sounds. For reproducibility of results, specifications and tests for the response to sound waves apply without an operator present in the sound field.
Pattern evaluation tests and periodic tests described in this this document apply to personal sound exposure meters for which the manufacturer claims conformance to the specifications given in this document.
IEC 61252:2025 cancels and replaces the first edition published in 1993, Amendment 1:2000, and Amendment 2:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) personal sound exposure meters are required to provide indications of time-averaged sound level and peak sound level;
b) sound exposure is an optional quantity for indication;
c) specifications for physical quantities that do not follow the principle of equal-energy exchange rate have been added;
d) specifications for directional response have been added;
e) specifications for frequency weightings apply to the relative diffuse-field frequency response;
f) determination of conformance to specifications takes account of uncertainties of measurement;
g) detailed requirements for pattern-evaluation tests and periodic testing have been added.

  • Standard
    50 pages
    English language
    sale 15% off
  • Standard
    56 pages
    French language
    sale 15% off
  • Standard
    106 pages
    English and French language
    sale 15% off

IEC 60645-7:2025 applies to instruments designed for the measurement of auditory evoked potentials from the inner ear, the auditory nerve, and the brainstem, evoked by either acoustic or vibratory stimuli of short duration. This document defines the characteristics to be specified by the manufacturer, specifies performance requirements for two types of instruments (screening and diagnostic/clinical), and specifies the functions to be provided on these types. It also specifies a means of describing the physical characteristics, in terms of electrical waveforms, of audiometric reference and test signals of short duration used with auditory evoked potential equipment and other equipment (e.g. otoacoustic emission instruments), and methods for their measurement. The purpose of this document is to ensure that measurements made under comparable test conditions with different instruments complying with this document will be consistent. This document is not intended to restrict development or incorporation of new features, nor to discourage innovative approaches. Evoked response measurement using the application of electric stimuli to a subject is beyond the scope of this document.

  • Standard
    24 pages
    English language
    e-Library read for
    ×1 day

This document specifies measurement methods and conditions to obtain reproducible and comparable exterior noise emission levels and spectra for all kinds of vehicles operating on rails or other types of fixed track, hereinafter conventionally called “unit”.
This document is applicable to type testing of units.
It provides measurement procedures for vehicle exterior noise (in general, a vehicle type test is carried out using only a selected subset of these tests):
—     when the vehicle is moving at constant speed;
—     when the vehicle is accelerating or decelerating;
—     when the vehicle is stationary in different operating conditions.
It does not include all the instructions to characterize the noise emission of the infrastructure related sources (bridges, crossings, switching, impact noise, curving noise, etc.).
This document does not apply to
—     the noise emission of track maintenance units while working,
—     environmental impact assessment (collection of data to be used in a prediction method for environmental assessment),
—     noise immission assessment,
—     guided buses, and
—     warning signal noise.
The results can be used, for example
—     to characterize the exterior noise emitted by units,
—     to compare the noise emission of various units on a particular track section, and
—     to collect basic source data for units.
NOTE            Additional guidance is provided in Annex E for measurements in the specific case of urban rail vehicles.

  • Standard
    100 pages
    English language
    e-Library read for
    ×1 day

IEC 60704-2-3:2025 applies to single unit electric dishwashers for household and similar use, with or without automatic programme control, for cold and/or warm water supply, for detachable or permanent connection to water supply or sewage systems, intended for placing on the floor against a wall, for building-in or placing under a counter, a kitchen worktop or under a sink, for wall-mounting or on a counter. This fourth edition cancels and replaces the third edition published in 2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60704-1:2021,
b) change of the position of the test sample in the test enclosure (aligned to IEC 60704 1:2021),
c) detergent changed (aligned to IEC 60436:2025).
This International Standard is intended to be used in conjunction with the fourth edition of IEC 60704-1:2021.

  • Standard
    16 pages
    English language
    e-Library read for
    ×1 day

Loading...