SIGNIFICANCE AND USE
4.1 This practice is for use by design engineers, specifiers, regulatory agencies, owners, installers, and inspection organizations who are involved in the rehabilitation of pipes through the use of a Mechanical Trenchless Point Repair Sleeve with a Locking Gear Mechanism for Pipes of Varying Inner Diameter and Offset Joints within a damaged existing pipe.  
4.2 This practice applies to the following types of defects in pipe that can be repaired: longitudinal, radial and circumferential cracks, fragmentation, leaking joints, displacement or joint misalignment, closing or sealing unused laterals, corrosion, spalling, wear, leaks in the barrel of the pipe, deformation in the pipe and root penetration. There are no limitations on the diameters of the laterals that can be sealed. The degree of deformation that can be repaired is dependent on the minimum and maximum diameters for which the sleeve is applicable as listed in the tables of dimensions shown in Appendix X1 but shall never exceed 5 %.  
4.3 This practice applies to pipes made of vitrified clay, concrete, reinforced concrete, plastics, glass reinforced plastics, cast iron, ductile iron and steel for both pressure and non-pressure applications.  
4.4 In this practice, no issues of snagging waste or build-up of sludge or sediment have been recorded to date; the performance of this sleeve, however, depends on many factors; therefore, past operational records may not include all possible future conditions under which the user may install these sleeves.  
4.5 The suitability of the technology covered in this practice for a particular application shall be jointly decided by the authority, the engineer and the installer.
SCOPE
1.1 This practice establishes minimum requirements for good practices for the materials and installation of mechanical trenchless repair sleeve with a locking gear mechanism for pipes of varying inner diameter and offset joints in the range of 6 in. to 72 in. (150 mm to 1800 mm).  
1.2 This practice applies to storm, potable water, wastewater and industrial pipes, conduits and drainage culverts.  
1.3 When the specified materials are used in manufacturing the sleeve and installed in accordance with this practice, the sleeve shall extend over a predetermined length of the host pipe as a continuous, tight fitting, corrosion resistant and verifiable non-leaking pipe repaired using one or more pieces of the repair sleeve mechanism. The maximum internal pressure this sleeve can carry depends on the diameter and the wall thickness, ranging from 10 to 15 bars; the external pressure shall not exceed 1.5 bars.  
1.4 All materials in contact with potable water shall be certified to meet NSF/ANSI 61/372.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    14 pages
    English language

SIGNIFICANCE AND USE
3.1 Definitions in this standard are to be regarded as correct for the terms found in other ASTM standards of Committee F36. Certain terms may be found in more than one standard issued under the jurisdiction of this committee and many of these terms have been placed in this standard.
SCOPE
1.1 This terminology standard is a compilation of definitions of technical terms related to optical fiber sensing systems, used in the various sections of standards under the jurisdiction of ASTM Committee F36.  
1.2 Where possible, definitions are stated as a single sentence, with necessary supplementary information as a Discussion. This approach is used to simplify explanations of the meanings of technical terms for the benefit of those not conversant with them, to facilitate a precise understanding and interpretation of F36 ASTM standards.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    12 pages
    English language

SIGNIFICANCE AND USE
4.1 Significance:  
4.1.1 Collection system maintenance requires allocating cleaning resources to the right place prior to system failure (sanitary sewer overflows, mainline blockages, and building backups). Transmissive acoustic inspection provides a tool to assist in allocating cleaning resources by prioritizing pipe segments based on their blockage assessment and thereby facilitating efficient cleaning resource allocation.  
4.1.2 This standard practice provides minimum requirements and suggested practices regarding the transmissive acoustic inspection of gravity-fed sewer line blockage assessment to meet the needs of maintenance personnel, engineers, contractors, authorities, regulatory agencies, and financing institutions.  
4.2 Limitations and Appropriate Uses:  
4.2.1 The blockage assessment provided by the transmissive acoustic inspection may not resolve the type of blockage(s) within the pipe segment nor resolve the location(s) of the blockage(s) within the pipe segment.  
4.2.2 Due to the physics associated with transmissive acoustic inspection, the blockage assessment may be confounded due to:
(1) Structural designs resulting in poor acoustic coupling,
(2) Pipe segments completely filled with water, for example, full pipe sag or inverted siphon, and
(3) Transient conditions within the pipe, for example, active lateral discharge or temporary flow surcharges.
These issues are addressed as part of the performance criteria specified in X1.5.  
4.2.3 Due to physics associated with acoustics and trade-offs in equipment design for conducting transmissive acoustic inspection, there are limitations based on the following pipe segment attributes:
(1) Pipe diameter,
(2) Pipe segment length,
(3) MH depth, and
(4) Flow levels.
Inspections conducted outside the manufacturer’s recommended ranges for these pipe segment attributes may result in the transmissive acoustic blockage assessment deviating from the performance criteria specified in X1.5...
SCOPE
1.1 This practice covers procedures for assessing the blockage within gravity-fed sewer pipes using transmissive acoustics for the purpose of prioritizing sewer pipe cleaning operations.2 The assessment is based on an acoustic receiver measuring the acoustic plane wave transmitted through the pipe segment under test in order to evaluate the blockage condition of an entire segment and to provide an onsite assessment of the blockage within the pipe segment. (1, 2, 3, 4, 5)3  
1.2 The scope of this practice covers the use of the transmissive acoustic inspection as a screening tool. The blockage assessment provided by the acoustic inspection should be used to identify and prioritize pipe segments requiring further maintenance action such as cleaning or visual inspection, or both. Thereby, also identifying the pipe segments which are sufficiently clean and do not require additional maintenance action.  
1.3 This standard practice does not address structural issues with the pipe wall.  
1.4 The inspection process requires access to the manhole (MH) from ground level. It does not require physical access to the sewer line by either the equipment or the operator.  
1.5 This standard practice applies to all types of pipe material.  
1.6 The inspection process requires access to sewers and operations along roadways or other locations that are safety hazards. This standard does not describe the hazards likely to be encountered or the safety procedures that must be carried out when operating in these hazardous environments.  
1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate s...

  • Standard
    7 pages
    English language

ABSTRACT
This practice describes the procedures involved in the structural reinforcement, sealing, protection, and rehabilitation of sanitary sewer manholes by the application of a prepackaged protective cementitious liner system to all cleaned interior surface from the bottom of the frame to the bench. The manholes to which the cementitious liner shall be applied may be made of brick, concrete, block, and various other materials. Detailed descriptions are given for all prepackaged materials necessary for this practice that include materials for substrate repairs, cementitious repair materials, infiltration water control materials, cementitious water control materials, chemical grout materials, and lining materials. Detailed descriptions are also provided for each procedure involved here which includes surface preparation, high pressure cleaning, surface repair, mixing of prepackaged cementitious repair materials, spray application of the cement liner by manual surface sealing or centrifugal cast process, and curing of the freshly applied cementitious mortar.
SCOPE
1.1 This specification describes all the work required to structurally reinforce, seal, and protect sanitary sewer manholes. Applications include applying a prepackaged cementitious liner that can function as a full depth restoration or a partial depth repair. A uniform high-strength, fiber-reinforced cementitious mortar should be manually sprayed and hand troweled or centrifugally cast in a uniform, prescribed thickness to all cleaned, interior surfaces from the bottom of the frame to the bench. The cementitious liner may be applied to manholes constructed of brick, concrete, block, and various other materials.  
1.2 A manufacturer’s approved applicator shall furnish the complete application of the protective, prepackaged cementitious liner material. All of the cleaning, preparation, and application procedures shall be in accordance with the manufacturer’s recommendations.  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Manholes are permit required confined spaces in accordance with OSHA definition and should be treated as such, requiring confined space entry permits, appropriate monitoring equipment, and the associated personal protective equipment.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
3.1 This practice is used as a guide for the installation of chemical grout in the practice of sealing sewer manholes from leaks, cracks, and around penetrations. It is attended to assist sewer owners and engineer, owner’s representative, or authorized inspectors for installation method specification and for contractors to refer to during installations of chemical grout for manhole sealing.
SCOPE
1.1 This practice covers proposed selection of materials, installation techniques, and inspection required for sealing manholes using chemical grout. Manholes or sections of manholes with active leaks shall be repaired. Manholes to be grouted are of brick, block, cast-in-place concrete, precast concrete, or fiberglass construction. Manholes or sections of manholes with active leaks will be designated by the engineer, owner’s representative, or authorized inspector, for manhole grouting.  
1.2 The contractor shall be responsible for furnishing all labor, supervision, materials, equipment, and inspection follow-up required for the completion of chemical grouting of manhole defects in accordance with the contract documents.  
1.3 Materials, additives, mixture ratios, and procedures utilized for the grouting process shall be in accordance with manufacturer’s recommendations and shall be appropriate for the application.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is for use by engineers, regulatory agencies, owners, and inspection organizations who are involved in the removal and replacement of AC pipes through the use of a method that is in compliance with the rules for removing and replacing AC pipe in accordance with NESHAP and OSHA requirements governing the handling, removal, and disposal of any ACM.
SCOPE
1.1 This practice covers the requirements and test methods of an EPA-approved alternative work practice (AWP) for the replacing of an Asbestos Cement (AC) pipe by the Close Tolerance Pipe Slurrification Method in accordance with said EPA CTPS AWP issued on June 10, 2019. This process utilizes a patented method (US 10,557,587 B2)2 and other specially designed tools designed to work with the EPA regulations surrounding AC pipe work. Specifically, the special (patented) back reaming tool (US 8,365,841 B2)2 delivers the required bentonite-based fluid to maintain a wet cutting environment which is an important requirement for cutting Asbestos Cement Material (ACM). The sizing of the cutting head is set at 0.25 in. in diameter greater than the replacement pipe's outside diameter to facilitate the removal of the ACM. This close tolerance sizing creates a scenario where the new pipe, along with the injection of the drill fluid, will allow the slurry to flow and subsequently expel at pre-determined pit locations. The slurry containing the ACM is then removed from the site and properly disposed of. Any remaining trace amounts of asbestos fiber in the ground are encapsulated in a skim coat of the slurry remaining around the new pipe, the skim coat having the consistency of a lightweight concrete material commonly known as excavatable flowable fill.  
1.2 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
4.1 The inspection, testing, and repair of sewer pipe joints is a practice that can assist in maintaining and optimizing sewer performance. It is important to identify methods that use the most current compounds and technology to ensure the reduction of infiltration and exfiltration. The method selected should utilize environmentally safe grout and minimize the disruption of traffic.  
4.2 This practice serves as a means to inspect, test, and seal sewer pipe joints, having selected the appropriate chemical grouts, using the packer method. Television inspection and joint testing are used to identify sewer line conditions, defective joints, and document the repairs undertaken. Instruction on joint sealing, if necessary, is then detailed, using pressure injection into the soils encompassing the pipe joint with a chemical grout (chemical sealing material).  
4.3 This practice should not be used for longitudinally cracked pipe, severely corroded pipe, structurally unsound pipe, flattened, or out-of-roundpipe. In areas with high groundwater pressure, greater than 10 psi (68.9 ksi) at the test point, consult equipment manufacturers.
SCOPE
1.1 This practice describes the procedures for testing and sealing individual sewer pipe joints with appropriate chemical grouts using the packer method. Sewer systems shall include sanitary, storm, and combined and their appurtenances. Chemical grouting is a soil sealing process, which seals the voids within the soil surrounding the exterior of the pipe at the point of leakage. Chemical grouting is not considered a structural repair.  
1.2 This practice applies to sewers 6 in. to 42 in. (18 cm to 107 cm) in diameter. Larger diameter pipe may be grouted with specialized packers or man entry methods. Host pipe interior surfaces must be adequate to create an effective seal for the packer elements.  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.4 Worker safety training should include reviewing the hazards associated with hoses, pumps, tanks, couplers, compressors, bottles, motors, and all other related application apparatus. Additional safety considerations including safely handling, mixing, and transporting of chemical grouts should be provided by the chemical grout manufacturer or supplier or both. Their safe operating practices and procedures should describe in detail appropriate personal protective equipment (PPE) for the various grouting operations. Operations covered should include the proper storage, transportation, mixing, and disposal of chemical grouts, additives, and their associated containers.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    8 pages
    English language
  • Standard
    8 pages
    English language

SIGNIFICANCE AND USE
4.1 Hydraulic cleaning methods include equipment that uses water and water velocity to clean the invert and walls of Thermoplastic Sewer Pipe.  
4.2 The practice of high-velocity sewer cleaning is best described as a hydraulic cleaning method that uses water pressure to remove obstructions and deposits in sewers or storm drains.  
4.3 There are different configurations of high-velocity sewer-cleaning machines. These units can generate variable water pressures up to 5000 psi (34 MPa) and variable flow rates of 50 gal per min (gpm) to 125 gal per min (gpm) (180 L per min to 473 L per min).  
4.4 The water tank capacity on these units varies from 1000 gal to 1500 gal (3785 L to 5678 L).  
4.5 The hose lengths vary between 500 ft and 1000 ft (152 m and 305 m) in length with a diameter of 3/4 in. to 11/4 in. NPT.  
4.6 There are a number of different nozzles and tools that may be used during the cleaning process.  
4.7 Some high-velocity sewer cleaners have a vacuum conveyance system that uses large fans or positive displacement vacuum pumps for material removal capabilities. With this type of system, material can be vacuumed from the manhole into a debris tank as it is brought back with the jet or tool and taken to a disposal area. These systems can be either trailer- or truck-mounted and are generally known as combination machines.  
4.8 The Occupational Safety and Health Administration (OSHA) has set guidelines for the safe removal of hazardous and nonhazardous substances as stated in OSHA Section 5 of Public Law 91-596; OSHA 29 USC 654; 29 CFR 1910.120; as well as DOT CFR 49 Parts 106–107, 171–180, and 390–397.
SCOPE
1.1 This practice covers the personnel requirements, operator training, Environmental Protection Agency (EPA) Guidelines, operating procedures, and recommended equipment performance/design for the proper operation of pressure water-jet cleaning and cutting equipment as normally used by municipalities and contractors concerned with operations, maintenance, and cleaning work of Municipal Thermoplastic gravity sewer pipe.  
1.2 The term high-pressure water jetting within this practice covers all water jetting, including the use of jets and hydro mechanical tooling at pressures below 2000 psi (0.69 MPa).  
1.3 This practice covers the high-pressure water jetting of Thermoplastic pipe and should not be applied to other pipe and pipe-lining materials without evaluating the recommended cleaning procedure from the pipe manufacturer to avoid damage.  
1.4 This practice applies to High-Density Polyethylene, Polypropylene, and Polyvinyl Chloride (HDPE, PP, and PVC) Thermoplastic sewer pipe manufactured in accordance with ASTM Standards. It may also be considered for use for any similar thermoplastic pipe products not covered by this list but with similar performance characteristics.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 5 on Hazards/Safety.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 Laser profiling assessment is a quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling capabilities include:  
4.1.1 Measurement of the structural shape, cross sectional area and defects;  
4.1.2 Collection of data needed for pipe rehabilitation or replacement design; and  
4.1.3 Post rehabilitation, replacement or new construction workmanship verification.  
4.2 A laser profile pre-acceptance and condition assessment survey provides significant information in a clear and concise manner, including but not limited to graphs and still frame digital images of pipe condition prior to acceptance, thereby providing objective data on the installed quality and percentage ovality, or degree of deformation, deflection or deviation, that is often not possible from an inspection by either a mandrel or only CCTV.
SCOPE
1.1 This practice covers the procedure for the post installation verification and acceptance of buried pipe deformation using a visible rotating laser light diode(s), a pipeline and conduit inspection analog or digital CCTV camera system and image processing software. The combination CCTV pipe inspection system, with cable distance counter or onboard distance encoder, rotating laser light diode(s) and ovality measurement software shall be used to perform a pipe measurement and ovality confirmation survey, of new or existing pipelines and conduits as directed by the responsible contracting authority. This standard practice provides minimum requirements on means and methods for laser profiling to meet the needs of engineers, contractors, owners, regulatory agencies, and financing institutions.  
1.2 This practice applies to all types of material, all types of construction, or shape.  
1.3 This practice applies to gravity flow storm sewers, drains, sanitary sewers, and combined sewers with diameters from 6 in. to 72 in. (150 mm to 1800 mm).  
1.4 The Laser Light Diode(s) shall be tested, labeled and certified to conform to US requirements for CDRH Class 2 or below (not considered to be hazardous) laser products or certified to conform to EU requirements for Class 2M or below laser products as per IEC 60825-1, or both.  
1.5 The profiling process may require physical access to lines, entry manholes and operations along roadways that may include safety hazards.  
1.6 This practice includes inspection requirements for determining pipeline and conduit ovality only and does not include all the required components of a complete inspection. The user of this practice should consider additional items outside this practice for inspection such as joint gap measurement, soil/water infiltration, crack and hole measurement, surface damage evaluation, evaluation of any pipeline repairs, and corrosion evaluation.  
1.7 This standard practice does not address limitations in accuracy due to improper lighting, dust, humidity, fog, moisture on pipe walls or horizontal/vertical offsets. Care should be taken to limit environmental factors in the pipeline that affect accuracy of the inspection.  
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. There are no safety hazards specifically, however, associated with the use of the laser profiler specified (listed and labeled as specified in 1.3).  
1.10 This international standard was deve...

  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
3.1 The inspection, testing, and repair of lateral connections for sanitary sewers are regular practice necessary for the maintenance and optimal performance of the system. It is important to identify methods that use the most current compounds and technology to ensure the reduction of infiltration and exfiltration. It is important to minimize disruption to traffic and lessen the environmental impacts for both the municipal and private owners.  
3.2 This practice serves as a means to inspect, test, and seal sewer lateral connections and a predetermined portion of the lateral lines from the mainline sewer, having selected the appropriate chemical grouts using the lateral packer method. Television (or optical) inspection and sewer lateral connection testing are used to assess the condition and document any repairs.  
3.3 This practice should not be used where mainline and lateral connections are found with longitudinally cracked pipe, structurally unsound pipe, or flattened or out of round pipe.
SCOPE
1.1 This practice covers the procedures for testing and sealing sewer lateral connections and lateral lines from the mainline sewer with appropriate chemical grouts using the lateral packer method. Chemical grouting is used to stop infiltration of ground water and exfiltration of sewage in gravity flow sewer systems that are structurally sound.  
1.2 This practice applies to mainline sewer diameters of 6 in. to 24 in. with 4 in., 5 in., or 6 in. diameter laterals. Larger diameter pipes with lateral connections and lines can be grouted with special packers or man-entry methods. The mainline and lateral pipes must be structurally adequate to create an effective seal.  
1.3 Worker safety training should include reviewing the biohazards and gases from sewage, confined spaces, pumping equipment, and related apparatus. Additional safety considerations including proper handling, mixing, and transporting of chemical grouts should be provided by the chemical grout manufacturer or supplier, or both. Their safe operating practices and procedures should describe in detail appropriate personal protective equipment (PPE) for the various grouting operations. Operations covered should include the proper storage, transportation, mixing, and disposal of chemical grouts, additives, and their associated containers.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
5.1 This is intended to outline O&M issues that require discussion and mutual agreement by both the optical fiber cable owner and sewer pipeline operator. The purpose is developing sufficient written procedures and practices to allow optical fiber systems to coexist as a secondary use within a sewer. To the extent that sewers are primarily for conveying flow, it is the responsibility of the optical fiber cable owner to accommodate sewer O&M practices and develop optical fiber system O&M procedures that will not material impact the sewer’s primary function.  
5.2 Since the practice of integrating sewers and optical fiber systems is an emerging activity, this practice will help establish guidelines for its rapid and safe deployment, ensuring that the installed facilities are operable as intended on a long-term basis.
SCOPE
1.1 This practice applies to the operation and maintenance of sewers with a subsequent installation of optical fiber cable in accordance with Practice F2303.  
1.2 This practice applies to gravity flow storm sewers, sanitary sewers, and combined sewers.  
1.3 This practice does not apply to force mains, siphons, or other pressurized sewers.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended to assist engineers and sewer owner/operators in determining the suitability of sewers for a secondary use as hosts for optical fiber cables and conduits. It must be kept in mind that the primary use of the sewers is to carry wastewater or storm water, or both. Any secondary use of the system shall not significantly impair the primary use. It is up to the engineer to decide upon any exceptions that may be involved in the selection process.  
5.2 Before the selection procedure begins, the installer must have explicit authorization from the owner/operator allowing an evaluation to be conducted for the installation of optical fiber cables or conduits within their sewer system.  
5.3 Engineers and owners should also be cognizant of how the installation of optical fiber cable or conduits will impact the future operational, maintenance, and rehabilitation needs of the sewers.
SCOPE
1.1 This practice specifically addresses the criteria for determining the suitability of gravity sewers for secondary uses such as the installation of optical fiber systems.  
1.1.1 This practice applies to the process of selecting gravity sewers that are appropriate for accepting an optical fiber system as opposed to standards for the installation, operation and maintenance of such system within sewers.  
1.2 This practice applies to both man accessible and man inaccessible sewer systems.  
1.3 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 Safety factors must be addressed and incorporated into the work to protect the workers and the public, and construction activities may need to be altered accordingly. Engineering and construction costs are a part of the analysis.  
4.2 Access rights to the work should be considered in the design of the project.  
4.3 A construction professional, who has field experience in construction activities similar to the scope of work anticipated, should review the plans for constructability prior to starting the project.  
4.4 Proper insurance and surety bonding to protect the interests of all parties to the agreement or contract should be considered.  
4.5 Risk management assessment will identify the parties that are in the best position to control and be responsible for the different risks.
SCOPE
1.1 This guide addresses only primary safety concerns, easements, constructability, liability of the various parties, and risk management related to constructing, installing, maintaining, or changing an optical fiber network in an existing sewer.  
1.2 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory requirements prior to use. See 4.1 and 5.1 – 5.1.7 for specific safety information.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Guide
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 Laser profiling assessment is a quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling can be used for:  
4.1.1 Measurement of the structural shape, cross sectional area and defects;  
4.1.2 Collection of data needed for pipe rehabilitation or replacement design; and  
4.1.3 Post rehabilitation, replacement or new construction workmanship verification.  
4.2 A laser profile pre-acceptance and condition assessment survey provides significant information in a clear and concise manner, including but not limited to graphs and still frame digital images of pipe condition prior to acceptance, thereby providing objective data on the installed quality and percentage ovality, deformation, deflection or deviation, that is often not possible from an inspection by either a mandrel or CCTV only survey.
SCOPE
1.1 Laser profiling is a non-contact inspection method used to create a pipe wall profile and internal measurement using a standard CCTV pipe inspection system, 360 degree laser light projector, a measurement by means of infrared sensors and geometrical profiling software. This practice covers the procedure for the measurement to determine any deviation of the internal surface of installed pipe compared to the design. The measurements may be used to verify that the installation has met design requirements for acceptance or to collect data that will facilitate an assessment of the condition of pipe or conduit due to structural deviations or deterioration. This standard practice provides minimum requirements on means and methods for laser profiling to meet the needs of engineers, contractors, owners, regulatory agencies, and financing institutions.  
1.2 This practice applies to all types of pipe material, all types of construction, and pipe shapes.  
1.3 This practice applies to depressurized and gravity flow storm sewers, drains, sanitary sewers, and combined sewers with diameters from 6 in. to 72 in. (150 mm and 1800 mm).  
1.4 This standard does not include all aspects of pipe inspection, such as joint gaps, soil/water infiltration in joints, cracks, holes, surface damage, repairs, corrosion, and structural problems associated with these conditions.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 The profiling process may require physical access to lines, entry manholes, and operations along roadways that may include safety hazards.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. There are no safety hazards specifically, however, associated with the use of the laser ring profiler specified (listed and labeled as specified in 1.3).  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SCOPE
1.1 This terminology is a compilation of definitions of technical terms used in the underground infrastructure and plastic piping industry. Terms that are generally understood or adequately defined in other readily available sources are not included.  
1.2 When a term is used in an ASTM document for which Committee F36 is responsible, it is included only when judged, after review, by Subcommittee F36.91 to be a generally usable term.  
1.3 Definitions that are identical to those published by other ASTM committees or other standards organizations are identified with the committee number (for example, F17) or with the abbreviation of the name of the organization (for example, IUPAC, International Union of Pure and Applied Chemistry).  
1.4 A definition is a single sentence with additional information included in discussions.  
1.5 Definitions are followed by the committee responsible for the standard(s) (for example, [F36.10]) and standard numbers(s) in which they are used (for example, F2233).  
1.6 Abbreviated Terminology:  
1.6.1 Abbreviated terminology is intended to provide uniform contractions of terms relating to infrastructure that have evolved through widespread common usage. The compilation in this standard has been prepared to avoid the occurrence of more than one abbreviated term for a given term and to avoid multiple meanings for abbreviated terms.  
1.6.2 The abbreviated terminology and descriptions in this standard are intended to be consistent with usage in the infrastructure industry and the standards under F36 jurisdiction. Other ASTM committees may assign a different word-phrase description to the same abbreviated terminology. In such cases, the abbreviated terms in this standard shall apply to usage in F36 standards, or if widespread misunderstanding could result from conflicting abbreviated terminology descriptions, the abbreviated terminology for the word-phrase shall not be used in F36 standards.  
1.6.3 Acronyms and Initialisms—A word formed from the letters or parts of words of a longer word-phrase, usually from the initial letters or parts of the words. An acronym is pronounced as a word, for example, radar for radio detection and ranging. An initialism is pronounced as a series of letters, for example, DOT for Department of Transportation.  
1.6.4 The acronym or initialism description is the origin word-phrase for the acronym or initialism, not a definition.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended to assist engineers, contractors and owner/operators of underground utilities and tunnels with the successful implementation of distributed optical fiber sensing for monitoring ground movements prior to construction for site planning and during utility and tunnel construction and operation and the impact of such ground movements on existing utilities.  
5.2 Before the installation of distributed optical fiber sensing begins, the contractor shall secure written explicit authorization from the owner/operator of the new tunnel/utility and the existing utilities allowing an evaluation to be conducted for the feasibility of distributed optical fiber sensing for monitoring ground movements for the intended purpose and to have access to certain locations of the structure and the surrounding ground. It may also be necessary for the installer to have written explicit authorization from applicable jurisdictional agencies such as the Department of Transportation, the Army Corps of Engineers, the Department of Environmental Protection and other.  
5.3 Engineers, contractors, and owners/operators shall also be cognizant of how the use of distributed optical fiber sensing for monitoring ground movements around utilities and tunnels might interfere with the use of certain equipment or tools near the installed optical fiber sensing cable in some special situations. For example, repair activities may have to temporarily remove, relocate, or avoid the optical fiber cable.  
5.4 Engineers, contractors, and owners/operators should be cognizant of how installation techniques and optical fiber (OF) cable location and protection can affect the performance of DOFSS.
SCOPE
1.1 This practice specifically addresses the means and methods for the use of distributed optical fiber sensors for monitoring ground movements during tunnel and utility construction and its impact on existing utilities.  
1.2 This practice applies to the process of selecting suitable materials, design, installation, data collection, data processing and reporting of results.  
1.3 This practice applies to all utilities that transport water, sewage, oil, gas, chemicals, electric power, communications and mass media content.  
1.4 This practice applies to all tunnels that transport and/or store water or sewage.  
1.5 This practice also applies to tunnels that carry the utilities in (1.3), water for hydropower, traffic, rail, freight, capsule transport, and those used for storage.  
1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    19 pages
    English language

SIGNIFICANCE AND USE
3.1 Definitions in this standard are to be regarded as correct for the terms found in other ASTM standards of Committee F36. Certain terms may be found in more than one standard issued under the jurisdiction of this committee and many of these terms have been placed in this standard.
SCOPE
1.1 This terminology standard is a compilation of definitions of technical terms related to optical fiber sensing systems, used in the various sections of standards under the jurisdiction of ASTM Committee F36.  
1.2 Where possible definitions are stated as a single sentence, with necessary supplementary information as a Discussion. This approach is used to simplify explanations of the meanings of technical terms for the benefit of those not conversant with them, to facilitate a precise understanding and interpretation of F36 ASTM standards.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    12 pages
    English language
  • Standard
    12 pages
    English language
  • Standard
    12 pages
    English language

SIGNIFICANCE AND USE
4.1 This practice is for use by design engineers, specifiers, regulatory agencies, owners, installers, and inspection organizations who are involved in the rehabilitation of pipes through the use of a Mechanical Trenchless Point Repair Sleeve with a Locking Gear Mechanism for Pipes of Varying Inner Diameter and Offset Joints within a damaged existing pipe.  
4.2 This practice applies to the following types of defects in pipe that can be repaired: longitudinal, radial and circumferential cracks, fragmentation, leaking joints, displacement or joint misalignment, closing or sealing unused laterals, corrosion, spalling, wear, leaks in the barrel of the pipe, deformation in the pipe and root penetration. There are no limitations on the diameters of the laterals that can be sealed. The degree of deformation that can be repaired is dependent on the minimum and maximum diameters for which the sleeve is applicable as listed in the tables of dimensions shown in Appendix X1 but shall never exceed 5 %.  
4.3 This practice applies to pipes made of vitrified clay, concrete, reinforced concrete, plastics, glass reinforced plastics, cast iron, ductile iron and steel for both pressure and non-pressure applications.  
4.4 In this practice, no issues of snagging waste or build-up of sludge or sediment have been recorded to date; the performance of this sleeve, however, depends on many factors; therefore, past operational records may not include all possible future conditions under which the user may install these sleeves.  
4.5 The suitability of the technology covered in this practice for a particular application shall be jointly decided by the authority, the engineer and the installer.
SCOPE
1.1 This practice establishes minimum requirements for good practices for the materials and installation of mechanical trenchless repair sleeve with a locking gear mechanism for pipes of varying inner diameter and offset joints in the range of 6 to 72 in. (150 to 1800 mm).  
1.2 This practice applies to storm, potable water, wastewater and industrial pipes, conduits and drainage culverts.  
1.3 When the specified materials are used in manufacturing the sleeve and installed in accordance with this practice, the sleeve shall extend over a predetermined length of the host pipe as a continuous, tight fitting, corrosion resistant and verifiable non-leaking pipe repaired using one or more pieces of the repair sleeve mechanism. The maximum internal pressure this sleeve can carry depends on the diameter and the wall thickness, ranging from 10 to 15 bars; the external pressure shall not exceed 1.5 bars.  
1.4 All materials in contact with potable water shall be certified to meet NSF/ANSI 61/372.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    14 pages
    English language
  • Standard
    14 pages
    English language
  • Standard
    14 pages
    English language

SIGNIFICANCE AND USE
4.1 Laser profiling assessment is a quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling can be used for:  
4.1.1 Measurement of the structural shape, cross sectional area and defects;  
4.1.2 Collection of data needed for pipe rehabilitation or replacement design; and  
4.1.3 Post rehabilitation, replacement or new construction workmanship verification.  
4.2 A laser profile pre-acceptance and condition assessment survey provides significant information in a clear and concise manner, including but not limited to graphs and still frame digital images of pipe condition prior to acceptance, thereby providing objective data on the installed quality and percentage ovality, deformation, deflection or deviation, that is often not possible from an inspection by either a mandrel or CCTV only survey.
SCOPE
1.1 Laser profiling is a non-contact inspection method used to create a pipe wall profile and internal measurement using a standard CCTV pipe inspection system, 360 degree laser light projector, and special geometrical profiling software. This practice covers the procedure for the measurement to determine any deviation of the internal surface of installed pipe compared to the design. The measurements may be used to verify that the installation has met design requirements for acceptance or to collect data that will facilitate an assessment of the condition of pipe or conduit due to structural deviations or deterioration. This standard practice provides minimum requirements on means and methods for laser profiling to meet the needs of engineers, contractors, owners, regulatory agencies, and financing institutions.  
1.2 This practice applies to all types of pipe material, all types of construction, and pipe shapes.  
1.3 This practice applies to depressurized and gravity flow storm sewers, drains, sanitary sewers, and combined sewers with diameters from 6 to 72 in. (150 and 1800 mm).  
1.4 This standard does not include all aspects of pipe inspection, such as joint gaps, soil/water infiltration in joints, cracks, holes, surface damage, repairs, corrosion, and structural problems associated with these conditions.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 The profiling process may require physical access to lines, entry manholes, and operations along roadways that may include safety hazards.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. There are no safety hazards specifically, however, associated with the use of the laser ring profiler specified (listed and labeled as specified in 1.3).  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
4.1 Laser profiling assessment is a quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling capabilities include:  
4.1.1 Measurement of the structural shape, cross sectional area and defects;  
4.1.2 Collection of data needed for pipe rehabilitation or replacement design; and  
4.1.3 Post rehabilitation, replacement or new construction workmanship verification.  
4.2 A laser profile pre-acceptance and condition assessment survey provides significant information in a clear and concise manner, including but not limited to graphs and still frame digital images of pipe condition prior to acceptance, thereby providing objective data on the installed quality and percentage ovality, or degree of deformation, deflection or deviation, that is often not possible from an inspection by either a mandrel or only CCTV.
SCOPE
1.1 This practice covers the procedure for the post installation verification and acceptance of buried pipe deformation using a visible rotating laser light diode(s), a pipeline and conduit inspection analog or digital CCTV camera system and image processing software. The combination CCTV pipe inspection system, with cable distance counter or onboard distance encoder, rotating laser light diode(s) and ovality measurement software shall be used to perform a pipe measurement and ovality confirmation survey, of new or existing pipelines and conduits as directed by the responsible contracting authority. This standard practice provides minimum requirements on means and methods for laser profiling to meet the needs of engineers, contractors, owners, regulatory agencies, and financing institutions.  
1.2 This practice applies to all types of material, all types of construction, or shape.  
1.3 This practice applies to gravity flow storm sewers, drains, sanitary sewers, and combined sewers with diameters from 6 to 72 in. (150 to 1800 mm).  
1.4 The Laser Light Diode(s) shall be tested, labeled and certified to conform to US requirements for CDRH Class 2 or below (not considered to be hazardous) laser products or certified to conform to EU requirements for Class 2M or below laser products as per IEC 60825-1, or both.  
1.5 The profiling process may require physical access to lines, entry manholes and operations along roadways that may include safety hazards.  
1.6 This practice includes inspection requirements for determining pipeline and conduit ovality only and does not include all the required components of a complete inspection. The user of this practice should consider additional items outside this practice for inspection such as joint gap measurement, soil/water infiltration, crack and hole measurement, surface damage evaluation, evaluation of any pipeline repairs, and corrosion evaluation.  
1.7 This standard practice does not address limitations in accuracy due to improper lighting, dust, humidity, fog, moisture on pipe walls or horizontal/vertical offsets. Care should be taken to limit environmental factors in the pipeline that affect accuracy of the inspection.  
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. There are no safety hazards specifically, however, associated with the use of the laser profiler specified (listed and labeled as specified in 1.3).  
1.10 This international standard was developed i...

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
4.1 Laser profiling assessment is a quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling capabilities include:  
4.1.1 Measurement of the structural shape, cross sectional area and defects;  
4.1.2 Collection of data needed for pipe rehabilitation or replacement design; and  
4.1.3 Post rehabilitation, replacement or new construction workmanship verification.  
4.2 A laser profile pre-acceptance and condition assessment survey provides significant information in a clear and concise manner, including but not limited to graphs and still frame digital images of pipe condition prior to acceptance, thereby providing objective data on the installed quality and percentage ovality, or degree of deformation, deflection or deviation, that is often not possible from an inspection by either a mandrel or only CCTV.
SCOPE
1.1 This practice covers the procedure for the post installation verification and acceptance of buried pipe deformation using a visible rotating laser light diode(s), a pipeline and conduit inspection analog or digital CCTV camera system and image processing software. The combination CCTV pipe inspection system, with cable distance counter or onboard distance encoder, rotating laser light diode(s) and ovality measurement software shall be used to perform a pipe measurement and ovality confirmation survey, of new or existing pipelines and conduits as directed by the responsible contracting authority. This standard practice provides minimum requirements on means and methods for laser profiling to meet the needs of engineers, contractors, owners, regulatory agencies, and financing institutions.  
1.2 This practice applies to all types of material, all types of construction, or shape.  
1.3 This practice applies to gravity flow storm sewers, drains, sanitary sewers, and combined sewers with diameters from 6 to 72 in. (150 to 1800 mm).  
1.4 The Laser Light Diode(s) shall be tested, labeled and certified to conform to US requirements for CDRH Class 2 or below (not considered to be hazardous) laser products or certified to conform to EU requirements for Class 2M or below laser products as per IEC 60825-1, or both.  
1.5 The profiling process may require physical access to lines, entry manholes and operations along roadways that may include safety hazards.  
1.6 This practice includes inspection requirements for determining pipeline and conduit ovality only and does not include all the required components of a complete inspection. The user of this practice should consider additional items outside this practice for inspection such as joint gap measurement, soil/water infiltration, crack and hole measurement, surface damage evaluation, evaluation of any pipeline repairs, and corrosion evaluation.  
1.7 This standard practice does not address limitations in accuracy due to improper lighting, dust, humidity, fog, moisture on pipe walls or horizontal/vertical offsets. Care should be taken to limit environmental factors in the pipeline that affect accuracy of the inspection.  
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. There are no safety hazards specifically, however, associated with the use of the laser profiler specified (listed and labeled as specified in 1.3).  
1.10 This international standard was developed in accordance wit...

  • Standard
    5 pages
    English language
  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
4.1 Laser profiling assessment is a quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling can be used for:  
4.1.1 Measurement of the structural shape, cross sectional area and defects;  
4.1.2 Collection of data needed for pipe rehabilitation or replacement design; and  
4.1.3 Post rehabilitation, replacement or new construction workmanship verification.  
4.2 A laser profile pre-acceptance and condition assessment survey provides significant information in a clear and concise manner, including but not limited to graphs and still frame digital images of pipe condition prior to acceptance, thereby providing objective data on the installed quality and percentage ovality, deformation, deflection or deviation, that is often not possible from an inspection by either a mandrel or CCTV only survey.
SCOPE
1.1 Laser profiling is a non-contact inspection method used to create a pipe wall profile and internal measurement using a standard CCTV pipe inspection system, 360 degree laser light projector, and special geometrical profiling software. This practice covers the procedure for the measurement to determine any deviation of the internal surface of installed pipe compared to the design. The measurements may be used to verify that the installation has met design requirements for acceptance or to collect data that will facilitate an assessment of the condition of pipe or conduit due to structural deviations or deterioration. This standard practice provides minimum requirements on means and methods for laser profiling to meet the needs of engineers, contractors, owners, regulatory agencies, and financing institutions.  
1.2 This practice applies to all types of pipe material, all types of construction, and pipe shapes.  
1.3 This practice applies to depressurized and gravity flow storm sewers, drains, sanitary sewers, and combined sewers with diameters from 6 to 72 in. (150 and 1800 mm).  
1.4 This standard does not include all aspects of pipe inspection, such as joint gaps, soil/water infiltration in joints, cracks, holes, surface damage, repairs, corrosion, and structural problems associated with these conditions.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 The profiling process may require physical access to lines, entry manholes, and operations along roadways that may include safety hazards.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. There are no safety hazards specifically, however, associated with the use of the laser ring profiler specified (listed and labeled as specified in 1.3).  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
4.1 Significance:  
4.1.1 Collection system maintenance requires allocating cleaning resources to the right place prior to system failure (sanitary sewer overflows, mainline blockages, and building backups). Transmissive acoustic inspection provides a tool to assist in allocating cleaning resources by prioritizing pipe segments based on their blockage assessment and thereby facilitating efficient cleaning resource allocation.  
4.1.2 This standard practice provides minimum requirements and suggested practices regarding the transmissive acoustic inspection of gravity-fed sewer line blockage assessment to meet the needs of maintenance personnel, engineers, contractors, authorities, regulatory agencies, and financing institutions.  
4.2 Limitations and Appropriate Uses:  
4.2.1 The blockage assessment provided by the transmissive acoustic inspection may not resolve the type of blockage(s) within the pipe segment nor resolve the location(s) of the blockage(s) within the pipe segment.  
4.2.2 Due to the physics associated with transmissive acoustic inspection, the blockage assessment may be confounded due to:
(1) Structural designs resulting in poor acoustic coupling,
(2) Pipe segments completely filled with water, for example, full pipe sag or inverted siphon, and
(3) Transient conditions within the pipe, for example, active lateral discharge or temporary flow surcharges.
These issues are addressed as part of the performance criteria specified in X1.5.  
4.2.3 Due to physics associated with acoustics and trade-offs in equipment design for conducting transmissive acoustic inspection, there are limitations based on the following pipe segment attributes:
(1) Pipe diameter,
(2) Pipe segment length,
(3) MH depth, and
(4) Flow levels.
Inspections conducted outside the manufacturer’s recommended ranges for these pipe segment attributes may result in the transmissive acoustic blockage assessment deviating from the performance criteria specified in X1.5...
SCOPE
1.1 This practice covers procedures for assessing the blockage within gravity-fed sewer pipes using transmissive acoustics for the purpose of prioritizing sewer pipe cleaning operations.2 The assessment is based on an acoustic receiver measuring the acoustic plane wave transmitted through the pipe segment under test in order to evaluate the blockage condition of an entire segment and to provide an onsite assessment of the blockage within the pipe segment. (1, 2, 3, 4, 5)3  
1.2 The scope of this practice covers the use of the transmissive acoustic inspection as a screening tool. The blockage assessment provided by the acoustic inspection should be used to identify and prioritize pipe segments requiring further maintenance action such as cleaning or visual inspection, or both. Thereby, also identifying the pipe segments which are sufficiently clean and do not require additional maintenance action.  
1.3 This standard practice does not address structural issues with the pipe wall.  
1.4 The inspection process requires access to the manhole (MH) from ground level. It does not require physical access to the sewer line by either the equipment or the operator.  
1.5 This standard practice applies to all types of pipe material.  
1.6 The inspection process requires access to sewers and operations along roadways or other locations that are safety hazards. This standard does not describe the hazards likely to be encountered or the safety procedures that must be carried out when operating in these hazardous environments.  
1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate s...

  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
3.1 This practice is used as a guide for the installation of chemical grout in the practice of sealing sewer manholes from leaks, cracks, and around penetrations. It is attended to assist sewer owners and engineer, owner’s representative, or authorized inspectors for installation method specification and for contractors to refer to during installations of chemical grout for manhole sealing.
SCOPE
1.1 This practice covers proposed selection of materials, installation techniques, and inspection required for sealing manholes using chemical grout. Manholes or sections of manholes with active leaks shall be repaired. Manholes to be grouted are of brick, block, cast-in-place concrete, precast concrete, or fiberglass construction. Manholes or sections of manholes with active leaks will be designated by the engineer, owner’s representative, or authorized inspector, for manhole grouting.  
1.2 The contractor shall be responsible for furnishing all labor, supervision, materials, equipment, and inspection follow-up required for the completion of chemical grouting of manhole defects in accordance with the contract documents.  
1.3 Materials, additives, mixture ratios, and procedures utilized for the grouting process shall be in accordance with manufacturer’s recommendations and shall be appropriate for the application.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
3.1 The inspection, testing, and repair of lateral connections for sanitary sewers are regular practice necessary for the maintenance and optimal performance of the system. It is important to identify methods that use the most current compounds and technology to ensure the reduction of infiltration and exfiltration. It is important to minimize disruption to traffic and lessen the environmental impacts for both the municipal and private owners.  
3.2 This practice serves as a means to inspect, test, and seal sewer lateral connections and a predetermined portion of the lateral lines from the mainline sewer, having selected the appropriate chemical grouts using the lateral packer method. Television (or optical) inspection and sewer lateral connection testing are used to assess the condition and document any repairs.  
3.3 This practice should not be used where mainline and lateral connections are found with longitudinally cracked pipe, structurally unsound pipe, or flattened or out of round pipe.
SCOPE
1.1 This practice covers the procedures for testing and sealing sewer lateral connections and lateral lines from the mainline sewer with appropriate chemical grouts using the lateral packer method. Chemical grouting is used to stop infiltration of ground water and exfiltration of sewage in gravity flow sewer systems that are structurally sound.  
1.2 This practice applies to mainline sewer diameters of 6 to 24 in. with 4, 5, or 6 in. diameter laterals. Larger diameter pipes with lateral connections and lines can be grouted with special packers or man-entry methods. The mainline and lateral pipes must be structurally adequate to create an effective seal.  
1.3 Worker safety training should include reviewing the biohazards and gases from sewage, confined spaces, pumping equipment, and related apparatus. Additional safety considerations including proper handling, mixing, and transporting of chemical grouts should be provided by the chemical grout manufacturer or supplier, or both. Their safe operating practices and procedures should describe in detail appropriate personal protective equipment (PPE) for the various grouting operations. Operations covered should include the proper storage, transportation, mixing, and disposal of chemical grouts, additives, and their associated containers.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    6 pages
    English language
  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
4.1 The inspection, testing, and repair of sewer pipe joints is a practice that can assist in maintaining and optimizing sewer performance. It is important to identify methods that use the most current compounds and technology to ensure the reduction of infiltration and exfiltration. The method selected should utilize environmentally safe grout and minimize the disruption of traffic.  
4.2 This practice serves as a means to inspect, test, and seal sewer pipe joints, having selected the appropriate chemical grouts, using the packer method. Television inspection and joint testing are used to identify sewer line conditions, defective joints, and document the repairs undertaken. Instruction on joint sealing, if necessary, is then detailed, using pressure injection into the soils encompassing the pipe joint with a chemical grout (chemical sealing material).  
4.3 This practice should not be used for longitudinally cracked pipe, severely corroded pipe, structurally unsound pipe, flattened, or out-of-roundpipe. In areas with high groundwater pressure, greater than 10 psi (68.9 ksi) at the test point, consult equipment manufacturers.
SCOPE
1.1 This practice describes the procedures for testing and sealing individual sewer pipe joints with appropriate chemical grouts using the packer method. Sewer systems shall include sanitary, storm, and combined and their appurtenances. Chemical grouting is a soil sealing process, which seals the voids within the soil surrounding the exterior of the pipe at the point of leakage. Chemical grouting is not considered a structural repair.  
1.2 This practice applies to sewers 6 to 42 in. (18 to 107 cm) in diameter. Larger diameter pipe may be grouted with specialized packers or man entry methods. Host pipe interior surfaces must be adequate to create an effective seal for the packer elements.  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.4 Worker safety training should include reviewing the hazards associated with hoses, pumps, tanks, couplers, compressors, bottles, motors, and all other related application apparatus. Additional safety considerations including safely handling, mixing, and transporting of chemical grouts should be provided by the chemical grout manufacturer or supplier or both. Their safe operating practices and procedures should describe in detail appropriate personal protective equipment (PPE) for the various grouting operations. Operations covered should include the proper storage, transportation, mixing, and disposal of chemical grouts, additives, and their associated containers.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    8 pages
    English language
  • Standard
    8 pages
    English language

ABSTRACT
This practice describes the procedures involved in the structural reinforcement, sealing, protection, and rehabilitation of sanitary sewer manholes by the application of a prepackaged protective cementitious liner system to all cleaned interior surface from the bottom of the frame to the bench. The manholes to which the cementitious liner shall be applied may be made of brick, concrete, block, and various other materials. Detailed descriptions are given for all prepackaged materials necessary for this practice that include materials for substrate repairs, cementitious repair materials, infiltration water control materials, cementitious water control materials, chemical grout materials, and lining materials. Detailed descriptions are also provided for each procedure involved here which includes surface preparation, high pressure cleaning, surface repair, mixing of prepackaged cementitious repair materials, spray application of the cement liner by manual surface sealing or centrifugal cast process, and curing of the freshly applied cementitious mortar.
SCOPE
1.1 This specification describes all the work required to structurally reinforce, seal, and protect sanitary sewer manholes. Applications include applying a prepackaged cementitious liner that can function as a full depth restoration or a partial depth repair. A uniform high-strength, fiber-reinforced cementitious mortar should be manually sprayed and hand troweled or centrifugally cast in a uniform, prescribed thickness to all cleaned, interior surfaces from the bottom of the frame to the bench. The cementitious liner may be applied to manholes constructed of brick, concrete, block, and various other materials.  
1.2 A manufacturer’s approved applicator shall furnish the complete application of the protective, prepackaged cementitious liner material. All of the cleaning, preparation, and application procedures shall be in accordance with the manufacturer’s recommendations.  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Manholes are permit required confined spaces in accordance with OSHA definition and should be treated as such, requiring confined space entry permits, appropriate monitoring equipment, and the associated personal protective equipment.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended to assist engineers and sewer owner/operators in determining the suitability of sewers for a secondary use as hosts for optical fiber cables and conduits. It must be kept in mind that the primary use of the sewers is to carry wastewater or storm water, or both. Any secondary use of the system shall not significantly impair the primary use. It is up to the engineer to decide upon any exceptions that may be involved in the selection process.  
5.2 Before the selection procedure begins, the installer must have explicit authorization from the owner/operator allowing an evaluation to be conducted for the installation of optical fiber cables or conduits within their sewer system.  
5.3 Engineers and owners should also be cognizant of how the installation of optical fiber cable or conduits will impact the future operational, maintenance, and rehabilitation needs of the sewers.
SCOPE
1.1 This practice specifically addresses the criteria for determining the suitability of gravity sewers for secondary uses such as the installation of optical fiber systems.  
1.1.1 This practice applies to the process of selecting gravity sewers that are appropriate for accepting an optical fiber system as opposed to standards for the installation, operation and maintenance of such system within sewers.  
1.2 This practice applies to both man accessible and man inaccessible sewer systems.  
1.3 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    4 pages
    English language
  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
5.1 This is intended to outline O&M issues that require discussion and mutual agreement by both the optical fiber cable owner and sewer pipeline operator. The purpose is developing sufficient written procedures and practices to allow optical fiber systems to coexist as a secondary use within a sewer. To the extent that sewers are primarily for conveying flow, it is the responsibility of the optical fiber cable owner to accommodate sewer O&M practices and develop optical fiber system O&M procedures that will not material impact the sewer’s primary function.  
5.2 Since the practice of integrating sewers and optical fiber systems is an emerging activity, this practice will help establish guidelines for its rapid and safe deployment, ensuring that the installed facilities are operable as intended on a long-term basis.
SCOPE
1.1 This practice applies to the operation and maintenance of sewers with a subsequent installation of optical fiber cable in accordance with Practice F2303.  
1.2 This practice applies to gravity flow storm sewers, sanitary sewers, and combined sewers.  
1.3 This practice does not apply to force mains, siphons, or other pressurized sewers.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
4.1 Safety factors must be addressed and incorporated into the work to protect the workers and the public, and construction activities may need to be altered accordingly. Engineering and construction costs are a part of the analysis.  
4.2 Access rights to the work should be considered in the design of the project.  
4.3 A construction professional, who has field experience in construction activities similar to the scope of work anticipated, should review the plans for constructability prior to starting the project.  
4.4 Proper insurance and surety bonding to protect the interests of all parties to the agreement or contract should be considered.  
4.5 Risk management assessment will identify the parties that are in the best position to control and be responsible for the different risks.
SCOPE
1.1 This guide addresses only primary safety concerns, easements, constructability, liability of the various parties, and risk management related to constructing, installing, maintaining, or changing an optical fiber network in an existing sewer.  
1.2 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. See 4.1 and 5.1 – 5.1.7 for specific safety information.

  • Guide
    4 pages
    English language
  • Guide
    4 pages
    English language

SIGNIFICANCE AND USE
4.1 This practice is for use by design engineers, specifiers, regulatory agencies, owners, installers, and inspection organizations who are involved in the rehabilitation of pipes through the use of a Mechanical Trenchless Point Repair Sleeve with a Locking Gear Mechanism for Pipes of Varying Inner Diameter and Offset Joints within a damaged existing pipe.  
4.2 This practice applies to the following types of defects in pipe that can be repaired: longitudinal, radial and circumferential cracks, fragmentation, leaking joints, displacement or joint misalignment, closing or sealing unused laterals, corrosion, spalling, wear, leaks in the barrel of the pipe, deformation in the pipe and root penetration. There are no limitations on the diameters of the laterals that can be sealed. The degree of deformation that can be repaired is dependent on the minimum and maximum diameters for which the sleeve is applicable as listed in the tables of dimensions shown in Appendix X1 but shall never exceed 5 %.  
4.3 This practice applies to pipes made of vitrified clay, concrete, reinforced concrete, plastics, glass reinforced plastics, cast iron, ductile iron and steel for both pressure and non-pressure applications.  
4.4 In this practice, no issues of snagging waste or build-up of sludge or sediment have been recorded to date; the performance of this sleeve, however, depends on many factors; therefore, past operational records may not include all possible future conditions under which the user may install these sleeves.  
4.5 The suitability of the technology covered in this practice for a particular application shall be jointly decided by the authority, the engineer and the installer.
SCOPE
1.1 This practice establishes minimum requirements for good practices for the materials and installation of mechanical trenchless repair sleeve with a locking gear mechanism for pipes of varying inner diameter and offset joints in the range of 6 to 72 in. (150 to 1800 mm).  
1.2 This practice applies to storm, potable water, wastewater and industrial pipes, conduits and drainage culverts.  
1.3 When the specified materials are used in manufacturing the sleeve and installed in accordance with this practice, the sleeve shall extend over a predetermined length of the host pipe as a continuous, tight fitting, corrosion resistant and verifiable non-leaking pipe repaired using one or more pieces of the repair sleeve mechanism. The maximum internal pressure this sleeve can carry depends on the diameter and the wall thickness, ranging from 10 to 15 bars; the external pressure shall not exceed 1.5 bars.  
1.4 All materials in contact with potable water shall be certified to meet NSF/ANSI 61/372.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.

  • Standard
    14 pages
    English language

SIGNIFICANCE AND USE
5.1 This practice is intended to assist engineers, contractors and owner/operators of underground utilities and tunnels with the successful implementation of distributed optical fiber sensing for monitoring ground movements prior to construction for site planning and during utility and tunnel construction and operation and the impact of such ground movements on existing utilities.  
5.2 Before the installation of distributed optical fiber sensing begins, the contractor shall secure written explicit authorization from the owner/operator of the new tunnel/utility and the existing utilities allowing an evaluation to be conducted for the feasibility of distributed optical fiber sensing for monitoring ground movements for the intended purpose and to have access to certain locations of the structure and the surrounding ground. It may also be necessary for the installer to have written explicit authorization from applicable jurisdictional agencies such as the Department of Transportation, the Army Corps of Engineers, the Department of Environmental Protection and other.  
5.3 Engineers, contractors, and owners/operators shall also be cognizant of how the use of distributed optical fiber sensing for monitoring ground movements around utilities and tunnels might interfere with the use of certain equipment or tools near the installed optical fiber sensing cable in some special situations. For example, repair activities may have to temporarily remove, relocate, or avoid the optical fiber cable.  
5.4 Engineers, contractors, and owners/operators should be cognizant of how installation techniques and optical fiber (OF) cable location and protection can affect the performance of DOFSS.
SCOPE
1.1 This practice specifically addresses the means and methods for the use of distributed optical fiber sensors for monitoring ground movements during tunnel and utility construction and its impact on existing utilities.  
1.2 This practice applies to the process of selecting suitable materials, design, installation, data collection, data processing and reporting of results.  
1.3 This practice applies to all utilities that transport water, sewage, oil, gas, chemicals, electric power, communications and mass media content.  
1.4 This practice applies to all tunnels that transport and/or store water or sewage.  
1.5 This practice also applies to tunnels that carry the utilities in (1.3), water for hydropower, traffic, rail, freight, capsule transport, and those used for storage.  
1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    19 pages
    English language

SIGNIFICANCE AND USE
4.1 Operational experience and independent testing have fully documented that the usable life, maintenance and failure and mean time between failures (MTBF) in buried storm and wastewater lines can be directly affected by the defects during manufacturing, incorrect pipe storage, and improper installation, including improper compaction often resulting in the deformation and physical damage in newly installed, repaired and replaced pipelines. Laser profiling assessment is an effective quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing valuable means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling capabilities include:  
4.1.1 Measurement of the structural shape, cross sectional area and defects;  
4.1.2 Collection of data needed for better pipe rehabilitation or replacement design; and  
4.1.3 Post rehabilitation, replacement or new construction workmanship verification.  
4.2 This standard practice provides minimum requirements on means and methods for laser profiling to meet the needs of engineers, contractors, owners, regulatory agencies and financing institutions.  
4.3 A laser profile pre-acceptance and condition assessment survey shall provide significant information in a clear and concise manner, including but not limited to graphs and still frame digital images of pipe condition prior to acceptance, thereby providing objective data on the installed quality and percentage ovality, or degree of deformation, deflection or deviation, that is often not possible from an inspection by either a mandrel or only CCTV.  
4.4 This practice applies to gravity flow lines—storm sewers, sanitary sewers, combined sewers, siphons, edge drains, highway drains, and culverts, and to all other pipelines, ducts and conduits that are made accessible and meet the requirements of 1.3, regardless of shape, design configuration or...
SCOPE
1.1 This practice covers the procedure for the post installation verification and acceptance of buried pipe deformation using a visible rotating laser light diode(s), a pipeline and conduit inspection analog or digital CCTV camera system and image processing software. The combination CCTV pipe inspection system, with cable distance counter or onboard distance encoder, rotating laser light diode(s) and ovality measurement software shall be used to perform a pipe measurement and ovality confirmation survey, of new or existing pipelines and conduits as directed by the responsible contracting authority.  
1.2 This practice applies to all types of material, all types of construction, or shape.  
1.3 This practice applies to gravity flow storm sewers, drains, sanitary sewers, and combined sewers with diameters from 6 to 72 in. (150 to 1800 mm). The pipe shall be pre-cleaned and free of debris that would prevent the CCTV camera and laser diode assembly, shown in Fig. 1, from moving through the pipe, or adversely affect the accuracy of the survey. Flow or debris, within the line, shall be less than 10 % of the nominal pipe diameter or 6 in. (150 mm) in depth whichever is the lesser.
FIG. 1 CCTV—Rotating Laser Profile Camera in Pipe  
1.4 The Laser Light Diode(s) shall be tested, labeled and certified to conform to US requirements for CDRH Class 2 or below (not considered to be hazardous) laser products or certified to conform to EU requirements for Class 2M or below laser products as per IEC 60825-1, or both.  
1.5 The profiling process may require physical access to lines, entry manholes and operations along roadways that may include safety hazards.  
1.6 This practice includes inspection requirements for determining pipeline and conduit ovality only and does not include all the required components of a complete inspection. The user of this practice should consider additional items outside this practice for inspection su...

  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
4.1 Operational experience and independent testing have fully documented that the usable life, maintenance and failure and mean time between failures (MTBF) in buried storm and wastewater lines can be directly affected by the defects during manufacturing, incorrect pipe storage, and improper installation, including improper compaction often resulting in the deformation (Ovality or shape, or both) and physical damage in newly installed, repaired and replaced pipelines. Laser profiling assessment is an effective quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing valuable means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling can be used for:  
4.1.1 Measurement of the structural shape, cross sectional area and defects;  
4.1.2 Collection of data needed for better pipe rehabilitation or replacement design; and  
4.1.3 Post rehabilitation, replacement or new construction workmanship verification.  
4.2 This standard practice provides minimum requirements on means and methods for laser profiling to meet the needs of engineers, contractors, owners, regulatory agencies and financing institutions.  
4.3 A laser profile pre-acceptance and condition assessment survey shall provide significant information in a clear and concise manner, including but not limited to graphs and still frame digital images of pipe condition prior to acceptance, thereby providing objective data on the installed quality and percentage ovality, deformation, deflection or deviation, that is often not possible from an inspection by either a mandrel or CCTV only survey.  
4.4 This practice applies to gravity flow or depressurized lines–storm sewers, sanitary sewers, combined sewers, siphons, edge drains, highway drains, and culverts, and to all other pipelines, ducts and conduits that are made accessible and meet the requirements of 1.3, regardless...
SCOPE
1.1 This practice covers the procedure for the measurement to determine any deviation of the internal surface of installed pipe compared to the design. The measurements may be used to verify that the installation has met design requirements for acceptance or to collect data that will facilitate an assessment of the condition of pipe or conduit due to structural deviations or deterioration.  
1.2 This practice applies to all types of pipe material, all types of construction, and pipe shapes.  
1.3 This practice applies to depressurized and gravity flow storm sewers, drains, sanitary sewers, and combined sewers with diameters from 6 to 72 in. (150 and 1800 mm). The pipe shall be precleaned and free of debris that would prevent the CCTV camera and laser projector assembly, shown in Fig. 1, from moving through the pipe, or adversely affect the accuracy of the survey. Flow or debris, within the line, shall be less than 10 % of the nominal pipe diameter or 6 in. in depth whichever is the lesser.  
1.4 The laser light projector shall be tested, labeled and certified to conform to US requirements for CDRH Class 2 or below (not considered to be hazardous) laser products or certified to conform to EU requirements for Class 2M or below laser products as per IEC 60825-1, or both.  
1.5 The profiling process may require physical access to lines, entry manholes and operations along roadways that may include safety hazards.  
1.6 This standard does not include all aspects of pipe inspection; for example the following are not covered by this standard: joint gaps, soil/water infiltration in joints, cracks, holes, surface damage, repairs, corrosion, and structural problems associated with these.  
1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.8 This standard...

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
3.1 Definitions in this standard are to be regarded as correct for the terms found in other ASTM standards of Committee F36. Certain terms may be found in more than one standard issued under the jurisdiction of this committee and many of these terms have been placed in this standard.
SCOPE
1.1 This terminology standard is a compilation of definitions of technical terms related to optical fiber sensing systems, used in the various sections of standards under the jurisdiction of ASTM Committee F36.  
1.2 Where possible definitions are stated as a single sentence, with necessary supplementary information as a Discussion. This approach is used to simplify explanations of the meanings of technical terms for the benefit of those not conversant with them, to facilitate a precise understanding and interpretation of F36 ASTM standards.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  • Standard
    12 pages
    English language

SIGNIFICANCE AND USE
3.1 The testing of sewers for leaks is a regular practice necessary for the maintenance and optimal performance of sewer collection systems so remedial action can be prioritized, designed, and carried out to reduce infiltration and exfiltration.  
3.2 This practice serves as a means to detect and locate all types of pipe defects that are potential sources of water leaks either into or out of electrically non-conducting pipes. Leaking joints and defective service connections are detected that often may not show as a defect when viewed from inside the pipe. The scan data may be processed and analyzed to provide some information on the size and type of pipe defect. (8.4.1)  
3.3 This practice applies to mainline and lateral gravity flow storm sewers, sanitary sewers, and combined sewers fabricated from electrically non-conducting material with diameters between 3 and 60 in. (75 and 1500 mm). The pipes must be free of obstructions that prevent the probe passing through the pipe.
SCOPE
1.1 This practice covers procedures for measuring the variation of electric current flow to detect and locate potential pipe leaks in pipes fabricated from electrically nonconductive materials such as brick, clay, concrete, and plastic pipes (that is, reinforced and non-reinforced). The method uses the variation of electric current flow through the pipe wall to locate defects that are potential water leakage paths either into or out of the pipe.  
1.2 This practice applies to mainline and lateral gravity flow storm sewers, sanitary sewers, and combined sewers with diameters between 3 and 60 in. (75 and 1500 mm). The pipes must be free of obstructions that prevent the probe passing through the pipe.  
1.3 The scanning process requires access to sewers, filling sewers, and operations along roadways that are safety hazards. This standard does not describe the hazards likely to be encountered or the safety procedures that must be carried out when operating in these hazardous environments. (7.1.3) There are no safety hazards specifically associated with the use of an electro-scan apparatus that complies with the specifications provided in this standard. (6.7 and 6.10.)  
1.4 The measurement of the variation of electric current requires the insertion of various items into a sewer. There is always a risk that due to unknown structural conditions in the sewer such items may become lodged in the pipe or may cause the state of a sewer in poor structural condition to further deteriorate. This standard does not describe methods to assess the structural risk of a sewer.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    7 pages
    English language
  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
The inspection, testing, and repair of lateral connections for sanitary sewers are regular practice necessary for the maintenance and optimal performance of the system. It is important to identify methods that use the most current compounds and technology to ensure the reduction of infiltration and exfiltration. It is important to minimize disruption to traffic and lessen the environmental impacts for both the municipal and private owners.
This practice serves as a means to inspect, test, and seal sewer lateral connections and a predetermined portion of the lateral lines from the mainline sewer, having selected the appropriate chemical grouts using the lateral packer method. Television (or optical) inspection and sewer lateral connection testing are used to assess the condition and document any repairs.
This practice should not be used where mainline and lateral connections are found with longitudinally cracked pipe, structurally unsound pipe, or flattened or out of round pipe.
SCOPE
1.1 This practice covers the procedures for testing and sealing sewer lateral connections and lateral lines from the mainline sewer with appropriate chemical grouts using the lateral packer method. Chemical grouting is used to stop infiltration of ground water and exfiltration of sewage in gravity flow sewer systems that are structurally sound.
1.2 This practice applies to mainline sewer diameters of 6 to 24 in. with 4, 5, or 6 in. diameter laterals. Larger diameter pipes with lateral connections and lines can be grouted with special packers or man-entry methods. The mainline and lateral pipes must be structurally adequate to create an effective seal.
1.3 Worker safety training should include reviewing the biohazards and gases from sewage, confined spaces, pumping equipment, and related apparatus. Additional safety considerations including proper handling, mixing, and transporting of chemical grouts should be provided by the chemical grout manufacturer or supplier, or both. Their safe operating practices and procedures should describe in detail appropriate personal protective equipment (PPE) for the various grouting operations. Operations covered should include the proper storage, transportation, mixing, and disposal of chemical grouts, additives, and their associated containers.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
The inspection, testing, and repair of sewer pipe joints is a practice that can assist in maintaining and optimizing sewer performance. It is important to identify methods that use the most current compounds and technology to ensure the reduction of infiltration and exfiltration. The method selected should utilize environmentally safe grout and minimize the disruption of traffic.
This practice serves as a means to inspect, test, and seal sewer pipe joints, having selected the appropriate chemical grouts, using the packer method. Television inspection and joint testing are used to identify sewer line conditions, defective joints, and document the repairs undertaken. Instruction on joint sealing, if necessary, is then detailed, using pressure injection into the soils encompassing the pipe joint with a chemical grout (chemical sealing material).
This practice should not be used for longitudinally cracked pipe, severely corroded pipe, structurally unsound pipe, flattened, or out-of-roundpipe. In areas with high groundwater pressure, greater than 10 psi (68.9 ksi) at the test point, consult equipment manufacturers.
SCOPE
1.1 This practice describes the procedures for testing and sealing individual sewer pipe joints with appropriate chemical grouts using the packer method. Sewer systems shall include sanitary, storm, and combined and their appurtenances. Chemical grouting is a soil sealing process, which seals the voids within the soil surrounding the exterior of the pipe at the point of leakage. Chemical grouting is not considered a structural repair.
1.2 This practice applies to sewers 6 to 42 in. (18 to 107 cm) in diameter. Larger diameter pipe may be grouted with specialized packers or man entry methods. Host pipe interior surfaces must be adequate to create an effective seal for the packer elements.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 Worker safety training should include reviewing the hazards associated with hoses, pumps, tanks, couplers, compressors, bottles, motors, and all other related application apparatus. Additional safety considerations including safely handling, mixing, and transporting of chemical grouts should be provided by the chemical grout manufacturer or supplier or both. Their safe operating practices and procedures should describe in detail appropriate personal protective equipment (PPE) for the various grouting operations. Operations covered should include the proper storage, transportation, mixing, and disposal of chemical grouts, additives, and their associated containers.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    8 pages
    English language
  • Standard
    8 pages
    English language

SIGNIFICANCE AND USE
This is intended to outline O&M issues that require discussion and mutual agreement by both the optical fiber cable owner and sewer pipeline operator. The purpose is developing sufficient written procedures and practices to allow optical fiber systems to coexist as a secondary use within a sewer. To the extent that sewers are primarily for conveying flow, it is the responsibility of the optical fiber cable owner to accommodate sewer O&M practices and develop optical fiber system O&M procedures that will not material impact the sewer’s primary function.
Since the practice of integrating sewers and optical fiber systems is an emerging activity, this practice will help establish guidelines for its rapid and safe deployment, ensuring that the installed facilities are operable as intended on a long-term basis.
SCOPE
1.1 This practice applies to the operation and maintenance of sewers with a subsequent installation of optical fiber cable in accordance with Practice F2303.
1.2 This practice applies to gravity flow storm sewers, sanitary sewers, and combined sewers.
1.3 This practice does not apply to force mains, siphons, or other pressurized sewers.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
Safety factors must be addressed and incorporated into the work to protect the workers and the public, and construction activities may need to be altered accordingly. Engineering and construction costs are a part of the analysis.
Access rights to the work should be considered in the design of the project.
A construction professional, who has field experience in construction activities similar to the scope of work anticipated, should review the plans for constructability prior to starting the project.
Proper insurance and surety bonding to protect the interests of all parties to the agreement or contract should be considered.
Risk management assessment will identify the parties that are in the best position to control and be responsible for the different risks.
SCOPE
1.1 This guide addresses only primary safety concerns, easements, constructability, liability of the various parties, and risk management related to constructing, installing, maintaining, or changing an optical fiber network in an existing sewer.
1.2 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. See 4.1 and 5.1-5.1.7 for specific safety information.

  • Guide
    4 pages
    English language

SIGNIFICANCE AND USE
This practice is intended to assist engineers and sewer owner/operators in determining the suitability of sewers for a secondary use as hosts for optical fiber cables and conduits. It must be kept in mind that the primary use of the sewers is to carry wastewater or storm water, or both. Any secondary use of the system shall not significantly impair the primary use. It is up to the engineer to decide upon any exceptions that may be involved in the selection process.
Before the selection procedure begins, the installer must have explicit authorization from the owner/operator allowing an evaluation to be conducted for the installation of optical fiber cables or conduits within their sewer system.
Engineers and owners should also be cognizant of how the installation of optical fiber cable or conduits will impact the future operational, maintenance, and rehabilitation needs of the sewers.
SCOPE
1.1 This practice specifically addresses the criteria for determining the suitability of gravity sewers for secondary uses such as the installation of optical fiber systems.
1.1.1 This practice applies to the process of selecting gravity sewers that are appropriate for accepting an optical fiber system as opposed to standards for the installation, operation and maintenance of such system within sewers.
1.2 This practice applies to both man accessible and man inaccessible sewer systems.
1.3 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    4 pages
    English language

ABSTRACT
This practice describes the procedures involved in the structural reinforcement, sealing, protection, and rehabilitation of sanitary sewer manholes by the application of a prepackaged protective cementitious liner system to all cleaned interior surface from the bottom of the frame to the bench. The manholes to which the cementitious liner shall be applied may be made of brick, concrete, block, and various other materials. Detailed descriptions are given for all prepackaged materials necessary for this practice that include materials for substrate repairs, cementitious repair materials, infiltration water control materials, cementitious water control materials, chemical grout materials, and lining materials. Detailed descriptions are also provided for each procedure involved here which includes surface preparation, high pressure cleaning, surface repair, mixing of prepackaged cementitious repair materials, spray application of the cement liner by manual surface sealing or centrifugal cast process, and curing of the freshly applied cementitious mortar.
SCOPE
1.1 This specification describes all the work required to structurally reinforce, seal, and protect sanitary sewer manholes. Applications include applying a prepackaged cementitious liner that can function as a full depth restoration or a partial depth repair. A uniform high-strength, fiber-reinforced cementitious mortar should be manually sprayed and hand troweled or centrifugally cast in a uniform, prescribed thickness to all cleaned, interior surfaces from the bottom of the frame to the bench. The cementitious liner may be applied to manholes constructed of brick, concrete, block, and various other materials.  
1.2 A manufacturer’s approved applicator shall furnish the complete application of the protective, prepackaged cementitious liner material. All of the cleaning, preparation, and application procedures shall be in accordance with the manufacturer’s recommendations.  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Manholes are permit required confined spaces in accordance with OSHA definition and should be treated as such, requiring confined space entry permits, appropriate monitoring equipment, and the associated personal protective equipment.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
This practice is used as a guide for the installation of chemical grout in the practice of sealing sewer manholes from leaks, cracks, and around penetrations. It is attended to assist sewer owners and engineer, owner’s representative, or authorized inspectors for installation method specification and for contractors to refer to during installations of chemical grout for manhole sealing.
SCOPE
1.1 This practice covers proposed selection of materials, installation techniques, and inspection required for sealing manholes using chemical grout. Manholes or sections of manholes with active leaks shall be repaired. Manholes to be grouted are of brick, block, cast-in-place concrete, precast concrete, or fiberglass construction. Manholes or sections of manholes with active leaks will be designated by the engineer, owner’s representative, or authorized inspector, for manhole grouting.
1.2 The contractor shall be responsible for furnishing all labor, supervision, materials, equipment, and inspection follow-up required for the completion of chemical grouting of manhole defects in accordance with the contract documents.
1.3 Materials, additives, mixture ratios, and procedures utilized for the grouting process shall be in accordance with manufacturer’s recommendations and shall be appropriate for the application.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
The testing of sewers for leaks is a regular practice necessary for the maintenance and optimal performance of sewer collection systems so remedial action can be prioritized, designed, and carried out to reduce infiltration and exfiltration.  
This practice serves as a means to detect and locate all types of pipe defects that are potential sources of water leaks either into or out of electrically non-conducting pipes. Leaking joints and defective service connections are detected that often may not show as a defect when viewed from inside the pipe. The electro-scan data maybe processed and analyzed to provide some information on the size and type of pipe defect. (8.4.1)
This practice applies to mainline and lateral gravity flow storm sewers, sanitary sewers, and combined sewers fabricated from electrically non-conducting material with diameters between 3 and 60 in. (75 and 1500 mm). The pipes must be free of obstructions that prevent the sonde passing through the pipe.
SCOPE
1.1 This practice covers procedures for using the electro-scan method to detect and locate potential pipe leak defects that are potential sources of leaks in pipes fabricated from electrically nonconductive material such as plastic, clay, and concrete (reinforced and non-reinforced). The electro-scan method uses the variation of electric current flow through the pipe wall to locate defects that are potential water leakage paths either into or out of the pipe.
1.2 This practice applies to mainline and lateral gravity flow storm sewers, sanitary sewers, and combined sewers with diameters between 3 and 60 in. (75 and 1500 mm). The pipes must be free of obstructions that prevent the sonde passing through the pipe.
1.3 The use of the electro-scan requires access to sewers, filling sewers, and operations along roadways that are safety hazards. This standard does not describe the hazards likely to be encountered or the safety procedures that must be carried out when operating in these hazardous environments. () There are no safety hazards specifically associated with the use of an electro-scan apparatus that complies with the specifications provided in this standard. ( and .)
1.4 The use of electro-scan requires the insertion of various items into a sewer. There is always a risk that due to unknown structural conditions in the sewer such items may become lodged in the pipe or may cause the state of a sewer in poor structural condition to further deteriorate. This standard does not describe methods to assess the structural risk of a sewer.
1.5 The values stated in inch/pound units are to be regarded as the standard. The values in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    7 pages
    English language

SIGNIFICANCE AND USE
This is intended to outline O&M issues that require discussion and mutual agreement by both the optical fiber cable owner and sewer pipeline operator. The purpose is developing sufficient written procedures and practices to allow optical fiber systems to coexist as a secondary use within a sewer. To the extent that sewers are primarily for conveying flow, it is the responsibility of the optical fiber cable owner to accommodate sewer O&M practices and develop optical fiber system O&M procedures that will not material impact the sewer’s primary function.
Since the practice of integrating sewers and optical fiber systems is an emerging activity, this practice will help establish guidelines for its rapid and safe deployment, ensuring that the installed facilities are operable as intended on a long-term basis.
SCOPE
1.1 This practice applies to the operation and maintenance of sewers with a subsequent installation of optical fiber cable per Practice F 2303.
1.2 This practice applies to gravity flow storm sewers, sanitary sewers, and combined sewers.
1.3 This practice does not apply to force mains, siphons or other pressurized sewers.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
The inspection, testing, and repair of lateral connections for sanitary sewers are regular practice necessary for the maintenance and optimal performance of the system. It is important to identify methods that use the most current compounds and technology to ensure the reduction of infiltration and exfiltration. It is important to minimize disruption to traffic and lessen the environmental impacts for both the municipal and private owners.
This practice serves as a means to inspect, test, and seal sewer lateral connections and a predetermined portion of the lateral lines from the mainline sewer, having selected the appropriate chemical grouts using the lateral packer method. Television (or optical) inspection and sewer lateral connection testing are used to assess the condition and document any repairs.
This practice should not be used where mainline and lateral connections are found with longitudinally cracked pipe, structurally unsound pipe, or flattened or out of round pipe.
SCOPE
1.1 This practice covers the procedures for testing and sealing sewer lateral connections and lateral lines from the mainline sewer with appropriate chemical grouts using the lateral packer method. Chemical grouting is used to stop infiltration of ground water and exfiltration of sewage in gravity flow sewer systems that are structurally sound.
1.2 This practice applies to mainline sewer diameters of 6 to 24 in. with 4, 5, or 6 in. diameter laterals. Larger diameter pipes with lateral connections and lines can be grouted with special packers or man-entry methods. The mainline and lateral pipes must be structurally adequate to create an effective seal.
1.3 Worker safety training should include reviewing the biohazards and gases from sewage, confined spaces, pumping equipment, and related apparatus. Additional safety considerations including proper handling, mixing, and transporting of chemical grouts should be provided by the chemical grout manufacturer or supplier, or both. Their safe operating practices and procedures should describe in detail appropriate personal protective equipment (PPE) for the various grouting operations. Operations covered should include the proper storage, transportation, mixing, and disposal of chemical grouts, additives, and their associated containers.
1.4 The values stated in inch/pound units are to be regarded as the standard. The values in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    6 pages
    English language

SIGNIFICANCE AND USE
This practice is used as a guide for the installation of chemical grout in the practice of sealing sewer manholes from leaks, cracks, and around penetrations. It is attended to assist sewer owners and engineer, owner’s representative, or authorized inspectors for installation method specification and for contractors to refer to during installations of chemical grout for manhole sealing.
SCOPE
1.1 This practice covers proposed selection of materials, installation techniques, and inspection required for sealing manholes using chemical grout. Manholes or sections of manholes with active leaks shall be repaired. Manholes to be grouted are of brick, block, cast-in-place concrete, precast concrete, or fiberglass construction. Manholes or sections of manholes with active leaks will be designated by the engineer, owners representative, or authorized inspector, for manhole grouting.
1.2 The contractor shall be responsible for furnishing all labor, supervision, materials, equipment, and inspection follow-up required for the completion of chemical grouting of manhole defects in accordance with the contract documents.
1.3 Materials, additives, mixture ratios, and procedures utilized for the grouting process shall be in accordance with manufacturers recommendations and shall be appropriate for the application.
1.4 The values stated in inch/pound units are to be regarded as the standard. The values in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    4 pages
    English language

SIGNIFICANCE AND USE
This practice is intended to assist engineers, LDC’and installers in determining the suitability of gas pipelines for a secondary use as carriers for optical fiber systems. It must be kept in mind that the primary use of the gas pipelines is to deliver natural gas to the end customer. Any secondary use of the system shall have minimal impact on its primary function. It is up to the engineer to decide upon the order of operations and any exceptions that may be involved in the selection process.
Before the selection procedure begins, the LDC must have developed an explicit agreement authorizing an installer to place optical fiber cables within their piping system.
The relevant LDC engineers should also be cognizant of how the installation of optical fiber cable will impact the future gas deliverability, operation, maintenance, and rehabilitation needs of the pipelines to be used as carriers of optical fiber systems.
SCOPE
1.1 This practice specifically addresses the criteria for determining the suitability of natural gas pipelines for use as conduits for optical fiber cable systems, as opposed to standards for the operation and maintenance of such a system.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values provided in parentheses are for information purposes only.
1.3 This practice does not apply to natural gas transmission lines.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    3 pages
    English language

SIGNIFICANCE AND USE
This practice is intended to assist optical fiber cable owners and pipeline operators in developing operating and maintenance procedures and practices for the secondary use of gas pipelines as conduits for optical fiber cables. It must be kept in mind that the primary use of gas pipelines is for transportation of natural gas and any secondary use of the system must not materially impact the primary function. It is the responsibility of the optical fiber cable owner and pipeline operator to decide how best to integrate operating and maintenance procedures for the pipeline, the optical fiber system, and the optical fiber cable so that safety is not compromised, customers are served in the best way possible, and incremental costs are minimized.
Since the practice of integrating gas pipeline facilities and fiber optics for telecommunications purposes is a new and emerging activity, this standard will help establish guidelines for its rapid and safe deployment and will ensure that the facilities installed are maintained to operate on a long-term basis.
SCOPE
1.1 This practice covers the operation and maintenance of natural gas distribution and service pipelines containing optical fiber cable and the operation and maintenance of the optical fiber system.
1.2 This practice applies to distribution and service lines used to transport natural gas.
1.3 This practice does not apply to natural gas transmission lines.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    5 pages
    English language

SIGNIFICANCE AND USE
This practice is intended to assist engineers and sewer owner/operators in determining the suitability of sewers for a secondary use as hosts for optical fiber cables and conduits. It must be kept in mind that the primary use of the sewers is to carry wastewater and/or storm water. Any secondary use of the system shall not significantly impair the primary use. It is up to the engineer to decide upon any exceptions that may be involved in the selection process.
Before the selection procedure begins, the installer must have explicit authorization from the owner/operator allowing an evaluation to be conducted for the installation of optical fiber cables or conduits within their sewer system.
Engineers and owners should also be cognizant of how the installation of optical fiber cable or conduits will impact the future operational, maintenance and rehabilitation needs of the sewers.
SCOPE
1.1 This practice specifically addresses the criteria for determining the suitability of gravity sewers for secondary uses such as the installation of optical fiber systems.
1.1.1 This practice applies to the process of selecting gravity sewers that are appropriate for accepting an optical fiber system as opposed to standards for the installation, operation and maintenance of such system within sewers.
1.2 This practice applies to both man accessible and man inaccessible sewer systems.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values provided in parentheses are for information purposes only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    4 pages
    English language

Frequently Asked Questions

F36 is a Technical Committee within ASTM International. It is named "Technology and Underground Utilities" and is responsible for: The scope of the Committee shall be the development of standards (test methods, practices, guides, specifications, classifications, and terminology) for the: * Use of underground utilities and their appurtenance for uses other than their originally intended function; * Application of current technology for the maintenance and repair of underground utilities, and * Additional design considerations for unique environments. Specific focuses under this scope include, but are not limited to: * The installing and operating of optical fiber systems in existing sewer systems. Existing gravity sewer systems shall include sanitary, storm, and combined, and their appurtenances. * The rehabilitation of sewer systems using chemical grouting. Existing sewer systems shall include sanitary, storm and combined, and their appurtenances; and * The parameters for design of water systems to incorporate best practices for ensuring their integrity during seismic events. This is inclusive of below-grade water conveyance systems, with exception to the consideration of aboveground cylindrical storage tanks. The work of the Committee will be coordinated with other ASTM Activities and Committees, and with other organizations having mutual interest. This committee has published 55 standards.

F36 develops ASTM standards in the area of Information technology. The scope of work includes: The scope of the Committee shall be the development of standards (test methods, practices, guides, specifications, classifications, and terminology) for the: * Use of underground utilities and their appurtenance for uses other than their originally intended function; * Application of current technology for the maintenance and repair of underground utilities, and * Additional design considerations for unique environments. Specific focuses under this scope include, but are not limited to: * The installing and operating of optical fiber systems in existing sewer systems. Existing gravity sewer systems shall include sanitary, storm, and combined, and their appurtenances. * The rehabilitation of sewer systems using chemical grouting. Existing sewer systems shall include sanitary, storm and combined, and their appurtenances; and * The parameters for design of water systems to incorporate best practices for ensuring their integrity during seismic events. This is inclusive of below-grade water conveyance systems, with exception to the consideration of aboveground cylindrical storage tanks. The work of the Committee will be coordinated with other ASTM Activities and Committees, and with other organizations having mutual interest. Currently, there are 55 published standards from this technical committee.

ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.

A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.

Loading...