SIST EN 60730-2-3:1996
(Main)Automatic electrical controls for household and similar use -- Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
General Information
- Abstract
Applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal protectors for ballasts for tubular fluorescent lamps supplied up to 600 V (50 Hz or 60 Hz).
- Status
- Published
- Publication Date
- 29-Feb-1996
- Technical Committee
- EPR - Electrical accessories
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Mar-1996
- Due Date
- 01-Mar-1996
- Completion Date
- 01-Mar-1996
Overview
SIST EN 60730-2-3:1996 specifies the particular requirements for thermal protectors used in ballasts for tubular fluorescent lamps. Developed by the Slovenski inštitut za standardizacijo (SIST), this standard addresses safety, operational values, and testing protocols for thermal protectors in household and similar electrical applications. It applies to devices operating with voltages up to 600 V at 50 Hz or 60 Hz, ensuring that these critical components maintain reliability and safety in lighting systems.
Key Topics
- Inherent Safety: The standard outlines criteria to guarantee the thermal protector's safe operation within fluorescent lamp ballasts, focusing on preventing overheating and potential fire hazards.
- Operating Values and Times: Defines essential parameters for the correct functioning of thermal protectors, including activation temperature thresholds and allowable response times.
- Operational Sequences: Specifies the necessary operation cycles and their connection to overall equipment safety.
- Testing Conditions: Establishes methods and requirements for testing thermal protectors to verify compliance with safety and performance standards.
Applications
Thermal protectors for ballasts play a vital role in both residential and commercial environments where tubular fluorescent lamps are used. Key practical applications include:
- Household Lighting Fixtures: Enhancing the safety and performance of lighting by preventing ballast overheating in kitchens, garages, basements, and living areas.
- Commercial Lighting Systems: Ensuring safe operation in offices, retail spaces, and industrial facilities where tubular fluorescent lamps are widespread.
- Retrofit and Replacement Parts: Providing reliable protection for replacement ballasts in both new installations and upgrades of existing lighting systems.
- Safety Compliance: Assisting manufacturers and installers in meeting regional and international safety regulations for lighting components.
By adhering to SIST EN 60730-2-3:1996, manufacturers can demonstrate compliance, support product certification, and decrease risks associated with thermal failures in fluorescent lighting systems.
Related Standards
For broader context and compliance, the following standards are often used alongside or referenced by SIST EN 60730-2-3:1996:
- EN 60730-1: General requirements for automatic electrical controls for household and similar use.
- IEC 730-2-3:1990: International equivalent focusing on thermal protectors for ballasts.
- IEC 60598 Series: Standards for general requirements and safety of luminaire equipment.
- SIST EN 61347 Series: Controls and requirements for lamp control gear.
Summary
SIST EN 60730-2-3:1996 plays a key role in the safety, functionality, and reliability of lighting systems using tubular fluorescent lamps. By specifying strict requirements for thermal protectors in ballasts, this standard helps reduce equipment failure, improve operational safety, and ensures conformity with European and international lighting standards. Adopting these guidelines supports safer and more reliable lighting environments in both domestic and commercial settings.
Relations
- Effective Date
- 01-Sep-2010
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 21-Sep-2010
- Effective Date
- 21-Sep-2010
- Effective Date
- 21-Sep-2010
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
SIST EN 60730-2-3:1996 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Automatic electrical controls for household and similar use -- Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps". This standard covers: Applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal protectors for ballasts for tubular fluorescent lamps supplied up to 600 V (50 Hz or 60 Hz).
Applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal protectors for ballasts for tubular fluorescent lamps supplied up to 600 V (50 Hz or 60 Hz).
SIST EN 60730-2-3:1996 is classified under the following ICS (International Classification for Standards) categories: 29.140.30 - Fluorescent lamps. Discharge lamps; 97.120 - Automatic controls for household use. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 60730-2-3:1996 has the following relationships with other standards: It is inter standard links to SIST EN 60730-2-3:2008, SIST EN 61558-1:2006, SIST EN 61046:2000, SIST EN 60928:1995, SIST EN 60922:1999, SIST EN 61347-1:2002, SIST EN 60730-2-3:1996/A2:2002, SIST EN 60730-2-3:1996/A11:2005, SIST EN 60730-2-3:1996/A1:1998. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 60730-2-3:1996 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 60730-2-3:1996 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI SIST EN 60730-2-3:1996
prva izdaja
STANDARD
marec 1996
Automatic electrical controls for household and similar use - Part 2: Particular
requirements for thermal protectors for ballasts for tubular fluorescent lamps (IEC
730-2-3:1990, modified)
ICS 29.1
...