SIST EN 60730-2-3:1996/A11:2005
(Amendment)Automatic electrical controls for household and similar use -- Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
General Information
- Abstract
Superseded by EN 60730-2-3:2007
- Status
- Published
- Publication Date
- 30-Apr-2005
- Technical Committee
- KNG - Automatic controls for household use
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-May-2005
- Due Date
- 01-May-2005
- Completion Date
- 01-May-2005
Overview
SIST EN 60730-2-3:1996/A11:2005 specifies the particular requirements for automatic electrical controls, specifically thermal protectors used in ballasts for tubular fluorescent lamps. Developed by the Slovenski inštitut za standardizacijo (SIST), this European standard serves as an essential reference for manufacturers, suppliers, and installers of household and similar electrical devices. It ensures safety, reliability, and efficiency in the functioning of thermal protectors, specifically designed for ballasts operating tubular fluorescent lighting systems.
The amendment A11 modifies the earlier EN 60730-2-3:1992 standard, clarifying its application and harmonizing its use across member countries of the European Committee for Electrotechnical Standardization (CENELEC).
Key Topics
- Scope of Application: The standard is limited to thermal protectors used in ballasts for tubular fluorescent lamps, excluding other types of controls (EN 60730-2-1 is not applicable).
- Safety Requirements: Focuses on ensuring thermal protectors perform reliably under defined conditions, minimizing fire risks and electrical hazards.
- Amendment Details: Provides clarification on the withdrawal of superseded standards and national adoption processes across Europe.
Highlights
- Precise guidelines for design, construction, and testing of thermal protectors.
- Alignment with European regulatory requirements for household electrical safety.
- Updated conformity dates and national standard withdrawal timelines.
Applications
Thermal protectors regulated by SIST EN 60730-2-3:1996/A11:2005 are vital components in:
- Fluorescent Lighting: Installed in ballasts for tubular fluorescent lamps in residential, commercial, and similar environments.
- Household Appliances: Used in electrical control systems where tubular fluorescent lighting is implemented, ensuring safe and efficient operation.
- Building Automation and Facility Management: Integrated into lighting systems for energy efficiency, overheating prevention, and equipment protection.
Practical Value:
- Manufacturers: Assure product safety and marketability by conforming to a recognized European standard.
- Installers and Maintenance Professionals: Rely on standardized safety features and compatibility for replacement parts in electrical systems.
- Regulatory Bodies: Reference for product certification, compliance checks, and market surveillance.
Related Standards
When implementing or referencing SIST EN 60730-2-3:1996/A11:2005, stakeholders should be aware of associated and superseded standards, ensuring comprehensive compliance:
- EN 60730-2-1: General requirements for automatic electrical controls (not applicable to thermal protectors for fluorescent lamp ballasts under this standard).
- EN 60730 Series: Covers a broader range of automatic electric controls for household and similar use.
- EN 60730-2-2 & EN 60730-2-2:2002: Additional part 2 standards for specific device categories.
- National Lighting Equipment Safety Regulations: For local conformity.
Keywords: automatic electrical controls, thermal protectors, ballasts, tubular fluorescent lamps, electrical safety standard, SIST, EN 60730-2-3, household electrical devices, fluorescent lighting safety.
For organizations involved in lighting and electrical appliance manufacturing or installation, adhering to SIST EN 60730-2-3:1996/A11:2005 ensures alignment with European best practices and enhances product safety and reliability in everyday applications.
Relations
- Effective Date
- 01-Sep-2010
- Effective Date
- 21-Sep-2010
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
SIST EN 60730-2-3:1996/A11:2005 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Automatic electrical controls for household and similar use -- Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps". This standard covers: Superseded by EN 60730-2-3:2007
Superseded by EN 60730-2-3:2007
SIST EN 60730-2-3:1996/A11:2005 is classified under the following ICS (International Classification for Standards) categories: 29.140.30 - Fluorescent lamps. Discharge lamps; 97.120 - Automatic controls for household use. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 60730-2-3:1996/A11:2005 has the following relationships with other standards: It is inter standard links to SIST EN 60730-2-3:2008, SIST EN 60730-2-3:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 60730-2-3:1996/A11:2005 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 60730-2-3:1996/A11:2005 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI SIST EN 60730-2-
3:1996/A11:2005
STANDARD
maj 2005
Avtomatske električne krmilne naprave za uporabo v gospodinjstvu in za
podobno uporabo - 2-3. del: Posebne zahteve za toplotno zaščito
predstikalnih naprav cevnih fluorescenčnih sijalk
Automatic electrical controls for household and similar use - Part 2-3: Particular
requirements for thermal protectors for ballasts for tubular fluorescent lamps
ICS 29.140.30; 97.120 Referenčna številka
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
EUROPEAN STANDARD EN 60730-2-3/A11
NORME EUROPÉENNE
EUROPÄISCHE NORM January 2005
ICS 29.140.30; 97.120
English version
Automatic electrical controls for household and similar use
Part 2-3: Particular requirements for thermal protectors
for ballasts for tubular fluorescent lamps
Dispositifs de commande électrique Automatische elektrische Regel-
automatiques à usage domestique und Steuergeräte für den Hausgebrauch
et analogue und ähnliche Anwendungen
Partie 2-3: Règles particulières Teil 2-3: Besondere Anforderungen an
pour les protecteurs thermiques thermische Schutzeinrichtungen
des ballasts pour lampes tubulaires für Vorschaltgeräte für röhrenförmige
à fluorescence Leuchtstofflampen
This amendment A11 modifies the European Standard EN 60730-2-3:1992; it was approved by
CENELEC on 2004-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal
Regulations which stipulate the conditions for giving this amendment the status of a national standard without
any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC
...