General Information

Abstract

D106/050: New dow * Corrigendum to EN/A1 issued March 2001

Status
Published
Publication Date
31-Aug-1998
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Sep-1998
Due Date
01-Sep-1998
Completion Date
01-Sep-1998

Buy Documents

Amendment

SIST EN 60730-2-3:1996/A1:1998

English language (7 pages)
Preview
Preview
e-Library read for
×1 day

Overview

SIST EN 60730-2-3:1996/A1:1998 is a Slovenski standard that specifies particular requirements for thermal protectors for ballasts used with tubular fluorescent lamps within automatic electrical controls for household and similar use. This document acts as an amendment to the previous standard, aligning with the modified IEC 60730-2-3:1990/A1:1995 and reflecting updates and corrections crucial to the safety and performance of such controls.

Thermal protectors are essential components designed to enhance the safety and reliability of electrical ballasts in fluorescent lighting systems. By automatically disconnecting or regulating the ballast under abnormal temperature conditions, these controls prevent potential hazards such as overheating or fire, making compliance with this standard critical for manufacturers and suppliers in the lighting and electrical industries.

Key Topics

  • Scope and Purpose
    The standard addresses the construction, operation, and testing of thermal protectors specifically intended for ballasts used with tubular fluorescent lamps, ensuring uniformity and safety in household electrical controls.

  • Amendments and Corrections
    Includes updates in line with Corrigendum to EN/A1 (March 2001), to correct and clarify existing text, improving the reliability of the standard for stakeholders.

  • Safety Requirements
    Sets out performance criteria and test procedures for thermal protection devices, focusing on electrical, mechanical, and thermal stability under normal and fault conditions.

  • Compatibility
    Applies to thermal protectors intended for use within automatic control equipment for both domestic and similar non-household applications, ensuring broad relevance across various installations.

  • Compliance and Testing
    Details assessment methods to verify that thermal protectors meet the necessary operational and safety benchmarks for use in fluorescent lamp ballasts.

Applications

Thermal protectors for ballasts for tubular fluorescent lamps are widely used in:

  • Residential lighting systems
    Ensuring safety in homes where tubular fluorescent lamps are used in kitchens, garages, basements, and other living spaces.
  • Commercial and industrial environments
    Applied within offices, retail, and manufacturing facilities where fluorescent lighting forms a core part of the illumination system.
  • Product development and certification
    Mandatory for manufacturers developing ballasts or lighting fixtures that utilize tubular fluorescent lamps and require certification for compliance with EU and international safety legislation.
  • Maintenance and safety upgrades
    Valuable for retrofitting older lighting installations with up-to-date thermal protection to meet current regulatory and safety requirements.

Related Standards

  • EN 60730-1 - General requirements for automatic electrical controls for household and similar use.
  • EN 60730-2-1 - Specific requirements for controls for electrical operating devices.
  • IEC 60730 - International series for automatic electrical control standards.
  • EN/IEC 60598 - Luminaires - General requirements and tests.
  • SIST EN 60730 series - Other national adaptations for specific control types and applications.

By adhering to SIST EN 60730-2-3:1996/A1:1998, manufacturers can demonstrate their commitment to product safety, regulatory compliance, and enhanced reliability in household and similar-use electrical controls, particularly for the vital application of thermal protectors in fluorescent lamp ballasts.

Relations

Effective Date
01-Sep-2010
Effective Date
21-Sep-2010

Buy Documents

Amendment

SIST EN 60730-2-3:1996/A1:1998

English language (7 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

SIST EN 60730-2-3:1996/A1:1998 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Automatic electrical controls for household and similar use -- Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps". This standard covers: D106/050: New dow * Corrigendum to EN/A1 issued March 2001

D106/050: New dow * Corrigendum to EN/A1 issued March 2001

SIST EN 60730-2-3:1996/A1:1998 is classified under the following ICS (International Classification for Standards) categories: 29.140.30 - Fluorescent lamps. Discharge lamps; 97.120 - Automatic controls for household use. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 60730-2-3:1996/A1:1998 has the following relationships with other standards: It is inter standard links to SIST EN 60730-2-3:2008, SIST EN 60730-2-3:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 60730-2-3:1996/A1:1998 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 60730-2-3:1996/A1:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-1998
Automatic electrical controls for household and similar use - Part 2: Particular
requirements for thermal protectors for ballasts for tubular fluorescent lamps -
Amendment A1 (IEC 60730-2-3:1990/A1:1995, modified)
Automatic electrical controls for household and similar use -- Part 2-3: Particular
requirements for thermal protectors for ballasts for tubular fluorescent lamps
Automatische elektrische Regel- und Steuergeräte für den Hausgebrauch und ähnliche
Anwendungen -- Teil 2-3: Besondere Anforderungen an thermische Schutzeinrichtungen
für Vorschaltgeräte für röhrenförmige Leuchtstofflampen
Dispositifs de commande électrique automatiques à usage domestique et analogue --
Partie 2-3: Règles particulières pour les protecteurs thermiques des ballasts pour lampes
tubulaires à fluorescence
Ta slovenski standard je istoveten z: EN 60730-2-3:1992/A1:1998
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
97.120 Avtomatske krmilne naprave Autom
...