kSIST FprEN 18299:2026
(Main)Soil improvers and growing media - Methods for the detection of Salmonella spp. and the enumeration of Escherichia coli and enterococci
- Abstract
This document specifies references to methods to be used for the detection of Salmonella spp. and the enumeration of Escherichia coli and enterococci in soil improvers and growing media, but does not contain the methods themselves.
This document is applicable to the fertilizing product blends where a blend is a mix of two or more fertilizing products belonging to the categories of fertilizers, liming material, soil improvers, growing media, inhibitors and plant biostimulants, and where soil improvers and/or growing media are the components with the highest percentage in the blend by mass or volume, or in the case of products in liquid form by dry mass. If the soil improvers and/or growing media are not the components with the highest percentage in the blend, the European Standard relevant to the component with the highest percentage in the blend applies. In case a blend is composed of fertilizing products mixed in equal quantities, the user of the standard decides which standard to apply.
NOTE A soil improver or a growing medium consists of a single bulky (volume-building) component or a mix of bulky (volume-building) components (for example peat, wood fibres, coconut coir, compost, expanded perlite).
- Status
- Not Published
- Public Enquiry End Date
- 01-Apr-2026
- Technical Committee
- KAT - Soil quality
- Current Stage
- 5020 - Formal vote (FV) (Adopted Project)
- Start Date
- 13-Nov-2026
- Due Date
- 01-Jan-2027
kSIST FprEN 18299:2026 is the SIST publication of the draft European Standard prEN 18299:2026 from CEN. It specifies which referenced methods are to be used for detecting Salmonella spp. and enumerating Escherichia coli and enterococci in soil improvers and growing media.
What does kSIST FprEN 18299:2026 specify?
kSIST FprEN 18299:2026 sets out the scope for microbiological checking of soil improvers, growing media, and certain fertilizing product blends. It does not give the test methods themselves; instead, it points the reader to the standards to use for sampling, sample preparation, detection, and enumeration.
The document applies to blends of two or more fertilising products when soil improvers and/or growing media are the components with the highest percentage by mass or volume, or by dry mass for liquid products. If another component is present in the highest percentage, the standard for that component applies instead. Where a blend contains products in equal quantities, the user decides which standard to apply.
| Annex / clause | What it covers |
|---|---|
| Clause 1 | Scope and applicability to soil improvers, growing media, and blends |
| Clause 2 | Normative references used by the document |
| Clause 3 | Terms and definitions taken from another standard |
| Clause 4 | Sampling and sample preparation |
| Clause 5 | Detection and enumeration steps by organism |
| Annex ZA | Link between the standard and Regulation (EU) 2019/1009 |
What are the key requirements of kSIST FprEN 18299:2026?
kSIST FprEN 18299:2026 is mainly a routing document: it tells the user which standards must be followed at each stage of the microbiological check. In practice, this matters because compliance work depends on taking the sample, preparing it, and then applying the correct organism-specific method.
Sampling and sample preparation
Clause 4 requires sampling to be done in accordance with EN 12579:2024. It also requires sample preparation to be done in accordance with prEN 13040-2:2025. For laboratories and sampling teams, this means the microbiological result depends on using the correct front-end handling before any organism is tested.
Detection and enumeration methods
Clause 5 links each microbiological target to a separate referenced method:
- Salmonella spp. detection uses prEN 18278:2026.
- Escherichia coli enumeration uses prEN 18280:2026.
- Enterococci enumeration uses prEN 18279:2026.
This structure matters because the document separates pathogen detection from organism counts, so users can select the correct method for the claim, specification, or regulatory check they need to perform.
Applicability to blends
The scope gives the rule for choosing the right standard when fertilising products are blended. That decision point is important in practice because the microbiological test standard follows the component that dominates the blend, not automatically the soil improver or growing medium component in every case.
Link to EU fertilising product requirements
Annex ZA connects the standard to Regulation (EU) 2019/1009 for the product function categories PFC 3 and PFC 4. For users working to EU fertilising product requirements, this annex shows how the clauses relate to the essential safety requirements for organic and inorganic soil improvers and for growing media.
What terms does kSIST FprEN 18299:2026 define?
kSIST FprEN 18299:2026 uses the terms and definitions from prEN 17732:2025. The document’s own technical language is centered on a few recurring terms.
- Soil improvers - Product function category PFC 3; the document treats these as products assessed for specific microbiological safety requirements.
- Growing media - Product function category PFC 4; the document applies the same microbiological framework to these products.
- Blend - A mix of two or more fertilising products from the listed categories, with the applicable standard depending on which component has the highest share.
- Salmonella spp. - The organism group for which the document requires a detection method.
- Escherichia coli - The organism for which the document requires an enumeration method.
- Enterococci - The organism for which the document requires an enumeration method.
- PFC - Product function category, the classification used in Regulation (EU) 2019/1009.
- OJEU - Official Journal of the European Union, where citation of the standard affects presumption of conformity.
Who uses kSIST FprEN 18299:2026?
kSIST FprEN 18299:2026 is used by laboratories, manufacturers, conformity assessment bodies, and regulatory users working with soil improvers, growing media, and fertilising product blends. It is relevant for sampling teams, microbiology labs, and quality staff who need to check Salmonella spp., Escherichia coli, and enterococci according to the referenced methods.
It also matters to suppliers placing EU fertilising products on the market under Regulation (EU) 2019/1009, because Annex ZA links the standard to the essential safety requirements for PFC 3 and PFC 4 products.
Which standards are used with kSIST FprEN 18299:2026?
kSIST FprEN 18299:2026 relies on several companion standards:
- prEN 17732:2025 - terminology for soil improvers and growing media
- EN 12579:2024 - sampling
- prEN 13040-2:2025 - sample preparation for microbiological examination
- prEN 18278:2026 - detection of Salmonella spp.
- prEN 18279:2026 - enumeration of enterococci
- prEN 18280:2026 - enumeration of Escherichia coli
These references are part of the document’s method chain, so users apply them together rather than treating this standard as a standalone test method.
What does the kSIST FprEN 18299:2026 document contain?
kSIST FprEN 18299:2026 contains five clauses, an informative Annex ZA, and a bibliography. Clause 4 and Clause 5 do the practical work by pointing to the sampling, preparation, detection, and enumeration standards that must be used.
Annex ZA provides the relationship with Regulation (EU) 2019/1009 and includes Table ZA.1, which maps the clauses to the relevant essential safety requirements for PFC 3 and PFC 4. The bibliography lists the regulation that frames the document’s market-access context.
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.

ECOCERT
Organic and sustainability certification.

FSC International
Forest Stewardship Council certification.
Sponsored listings
Frequently Asked Questions
kSIST FprEN 18299:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Soil improvers and growing media - Methods for the detection of Salmonella spp. and the enumeration of Escherichia coli and enterococci". This standard covers: This document specifies references to methods to be used for the detection of Salmonella spp. and the enumeration of Escherichia coli and enterococci in soil improvers and growing media, but does not contain the methods themselves. This document is applicable to the fertilizing product blends where a blend is a mix of two or more fertilizing products belonging to the categories of fertilizers, liming material, soil improvers, growing media, inhibitors and plant biostimulants, and where soil improvers and/or growing media are the components with the highest percentage in the blend by mass or volume, or in the case of products in liquid form by dry mass. If the soil improvers and/or growing media are not the components with the highest percentage in the blend, the European Standard relevant to the component with the highest percentage in the blend applies. In case a blend is composed of fertilizing products mixed in equal quantities, the user of the standard decides which standard to apply. NOTE A soil improver or a growing medium consists of a single bulky (volume-building) component or a mix of bulky (volume-building) components (for example peat, wood fibres, coconut coir, compost, expanded perlite).
This document specifies references to methods to be used for the detection of Salmonella spp. and the enumeration of Escherichia coli and enterococci in soil improvers and growing media, but does not contain the methods themselves. This document is applicable to the fertilizing product blends where a blend is a mix of two or more fertilizing products belonging to the categories of fertilizers, liming material, soil improvers, growing media, inhibitors and plant biostimulants, and where soil improvers and/or growing media are the components with the highest percentage in the blend by mass or volume, or in the case of products in liquid form by dry mass. If the soil improvers and/or growing media are not the components with the highest percentage in the blend, the European Standard relevant to the component with the highest percentage in the blend applies. In case a blend is composed of fertilizing products mixed in equal quantities, the user of the standard decides which standard to apply. NOTE A soil improver or a growing medium consists of a single bulky (volume-building) component or a mix of bulky (volume-building) components (for example peat, wood fibres, coconut coir, compost, expanded perlite).
kSIST FprEN 18299:2026 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.
kSIST FprEN 18299:2026 is associated with the following European legislation: EU Directives/Regulations: 2003/2003, 2019/1009; Standardization Mandates: M/564, M/564 Amd 1, M/564 Amd 2, M/XXX. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
kSIST FprEN 18299:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN 18299:2026
01-marec-2026
Izboljševalci tal in rastni substrati - Metode za ugotavljanje prisotnosti Salmonella
spp. ter ugotavljanje števila Escherichia coli in enterokokov
Soil improvers and growing media - Methods for the detection of Salmonella spp. and the
enumeration of Escherichia coli and enterococci
Organische Bodenverbesserungsmittel und Kultursubstrate - Nachweis spezifischer
Pathogene
Amendements du sol et supports de culture - Méthodes de recherche des Salmonella
spp. et de dénombrement des Escherichia coli et des entérocoques
Ta slovenski standard je istoveten z: prEN 18299
ICS:
65.080 Gnojila Fertilizers
oSIST prEN 18299:2026 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
oSIST prEN 18299:2026
oSIST prEN 18299:2026
DRAFT
EUROPEAN STANDARD
prEN 18299
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2026
ICS 65.080
English Version
Soil improvers and growing media - Methods for the
detection of Salmonella spp. and the enumeration of
Escherichia coli and enterococci
Amendements du sol et supports de culture - Méthodes Bodenverbesserungsmittel und Kultursubstrate -
de recherche des Salmonella spp. et de dénombrement Verfahren zum Nachweis von Salmonella spp. und zur
des Escherichia coli et des entérocoques Auszählung von Escherichia coli und Enterokokken
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 223.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATIO N
EUROPÄISCHES KOMITEE FÜR NORMUN G
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 18299:2026 E
worldwide for CEN national Members.
oSIST prEN 18299:2026
prEN 18299:2026 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Sampling and sample preparation . 5
5 Detection and enumeration . 6
Annex ZA (informative) Relationship of this European Standard and the essential requirements of
Regulation (EU) 2019/1009 making available on the market of EU fertilising products
aimed to be covered . 7
Bibliography . 8
oSIST prEN 18299:2026
prEN 18299:2026 (E)
European foreword
This document (prEN 18299:2026) has been prepared by Technical Committee CEN/TC 223 “Soil
improvers and growing media”, the secretariat of which is held by NEN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a standardisation request addressed to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
For the relationship with EU Legislation, see informative Annex ZA, which is an integral part of this
document.
oSIST prEN 18299:2026
prEN 18299:2026 (E)
Introduction
Different product functions warrant different product safety, quality and quantity requirements adapted
to their different intended uses. EU fertilizing products have therefore been divided into different product
function categories (PFCs), which are subject to specific safety, quality and quantity requirements, as
specified in the Regulation (EU) 2019/1009 [1].
Soil improvers have been classified as PFC 3, growing media have been classified as PFC 4. The specific
requirements in relation to specific pathogens (Escherichia coli, enterococci and Salmonella spp
...