Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power

This part of CISPR 16 is designated a basic standard, which specifies the methods of measurement of disturbance power using the absorbing clamp in the frequency range 30 MHz to 1 000 MHz. CISPR 16-2 has been reorganised into 4 parts, to accommodate growth and easier maintenance. This first edition of CISPR 16-2-2, together with CISPR 16-2-1, CISPR 16-2-3 and CISPR 16-2-4, cancels and replaces the second edition of CISPR 16-2, published in 2003. It contains the relevant clauses of CISPR 16-2 without technical changes.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2-2: Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Messung der Störleistung

Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 2-2: Méthodes de mesure des perturbations et de l'immunité - Mesure de la puissance perturbatrice

La présente partie de la CISPR 16 est une norme fondamentale qui spécifie la méthode de mesure de la puissance perturbatrice, utilisant la pince absorbante, dans la gamme de fréquences de 30 MHz à 1 000 MHz. La publication CISPR 16-2 a été réorganisée en 4 parties, dans le but de pouvoir gérer plus facilement son évolution et maintenance. Cette première édition de la CISPR 16-2-2, ainsi que les CISPR 16-2-1, CISPR 16-2-3 et CISPR 16-2-4, annule et remplace la seconde édition de la CISPR 16-2 publiée en 2003. Elle contient les articles en rapport avec la CISPR 16-2 sans modifications de leur contenu technique.

Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti – 2-2. del: Metode za merjenje radijskih motenj in odpornosti – Merjenje moči motenj (CISPR 16-2-2:2003)

General Information

Status
Withdrawn
Publication Date
21-Oct-2004
Withdrawal Date
31-Aug-2007
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
02-Jan-2014
Completion Date
02-Jan-2014

Relations

Effective Date
29-Jan-2023
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
29-Jan-2023
Effective Date
28-Jan-2023

Get Certified

Connect with accredited certification bodies for this standard

TL 9000 QuEST Forum

Telecommunications quality management system.

ANAB United States Verified

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 55016-2-2:2004 is a standard published by CLC. Its full title is "Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power". This standard covers: This part of CISPR 16 is designated a basic standard, which specifies the methods of measurement of disturbance power using the absorbing clamp in the frequency range 30 MHz to 1 000 MHz. CISPR 16-2 has been reorganised into 4 parts, to accommodate growth and easier maintenance. This first edition of CISPR 16-2-2, together with CISPR 16-2-1, CISPR 16-2-3 and CISPR 16-2-4, cancels and replaces the second edition of CISPR 16-2, published in 2003. It contains the relevant clauses of CISPR 16-2 without technical changes.

This part of CISPR 16 is designated a basic standard, which specifies the methods of measurement of disturbance power using the absorbing clamp in the frequency range 30 MHz to 1 000 MHz. CISPR 16-2 has been reorganised into 4 parts, to accommodate growth and easier maintenance. This first edition of CISPR 16-2-2, together with CISPR 16-2-1, CISPR 16-2-3 and CISPR 16-2-4, cancels and replaces the second edition of CISPR 16-2, published in 2003. It contains the relevant clauses of CISPR 16-2 without technical changes.

EN 55016-2-2:2004 is classified under the following ICS (International Classification for Standards) categories: 33.100.10 - Emission; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 55016-2-2:2004 has the following relationships with other standards: It is inter standard links to EN 55016-2-2:2011, EN 55016-2-4:2004, EN 55016-4-2:2004, EN 55016-2-3:2004, EN 55013:2001, EN 55014-1:2000, EN 55016-1-3:2004, EN 55016-1-3:2006, EN 55016-1-1:2004, EN 55014-1:2006, EN 55016-2-1:2004, EN 55013:2013, EN 55016-2-3:2006, EN 55016-2-2:2004/A2:2005, EN 55016-2-2:2004/A1:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 55016-2-2:2004 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 89/336/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 55016-2-2:2004 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI SIST EN 55016-2-2:2005

STANDARD
julij 2005
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in
odpornosti – 2-2. del: Metode za merjenje radijskih motenj in odpornosti –
Merjenje moči motenj (CISPR 16-2-2:2003)
Specification for radio disturbance and immunity measuring apparatus and methods
– Part 2-2: Methods of measurement of disturbances and immunity – Measurement
of disturbance power (CISPR 16-2-2:2003)
ICS 17.220.20; 33.100.20 Referenčna številka
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

EUROPEAN STANDARD EN 55016-2-2
NORME EUROPÉENNE
EUROPÄISCHE NORM October 2004

ICS 33.100.10; 33.100.20
English version
Specification for radio disturbance and immunity
measuring apparatus and methods
Part 2-2: Methods of measurement of disturbances and immunity –
Measurement of disturbance power
(CISPR 16-2-2:2003)
Spécifications des méthodes  Anforderungen an Geräte und
et des appareils de mesure Einrichtungen sowie Festlegung der
des perturbations radioélectriques Verfahren zur Messung der
et de l'immunité aux perturbations hochfrequenten Störaussendung
radioélectriques (Funkstörungen) und Störfestigkeit
Partie 2-2: Méthodes de mesure Teil 2-2: Verfahren zur Messung der
des perturbations et de l'immunité – hochfrequenten Störaussendung
Mesure de la puissance perturbatrice (Funkstörungen) und Störfestigkeit –
(CISPR 16-2-2:2003) Messung der Störleistung
(CISPR 16-2-2:2003)
This European Standard was approved by CENELEC on 2004-09-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 55016-2-2:2004 E
Foreword
The text of the International Standard CISPR
...