EN 13859-2:2004+A1:2008
(Main + Amendment)Flexible sheets for waterproofing - Definitions and characteristics of underlays - Part 2: Underlays for walls
Flexible sheets for waterproofing - Definitions and characteristics of underlays - Part 2: Underlays for walls
This document specifies the characteristics of flexible sheets for underlays for walls which are to be used in walls behind outside wall coverings in order to avoid penetration of wind and water from outside. It specifies the requirements and test methods and provides for the evaluation of conformity of the products with the requirements of this document.
Abdichtungsbahnen - Definitionen und Eigenschaften von Unterdeck- und Unterspannbahnen - Teil 2: Unterdeck- und Unterspannbahnen für Wände
Dieses Dokument legt Eigenschaften für Unterdeck- und Unterspannbahnen für Wände fest, die hinter außenseitigen Wandverkleidungen zu verlegen sind, um das Eindringen von Wind und Wasser von außen zu verhindern. Sie enthält Festlegungen der Anforderungen und Prüfverfahren sowie der Bewertung der Konformität von Produkten nach den Anforderungen dieses Dokumentes.
Feuilles souples d'étanchéité - Définitions et caractéristiques des écrans souples - Partie 2: Ecrans souples pour murs extérieurs
La présente Norme européenne spécifie les caractéristiques des écrans souples pare-pluie, destinés à être utilisés derrière l’habillage des murs extérieur, afin d’éviter la pénétration du vent et de l’eau venant de l’extérieur. Elle exprime les spécifications et les méthodes d’essai destinées à évaluer la conformité des produits avec les prescriptions du présent document.
Hidroizolacijski trakovi - Definicije in lastnosti podložnih folij - 2. del: Podložne folije za stene
General Information
- Status
- Withdrawn
- Publication Date
- 30-Sep-2008
- Withdrawal Date
- 22-Jun-2010
- Technical Committee
- CEN/TC 254 - Flexible sheets for water proofing
- Drafting Committee
- CEN/TC 254/WG 9 - Underlays for discontinuous roof coverings
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 23-Jun-2010
- Completion Date
- 23-Jun-2010
- Directive
- 89/106/EEC - Construction products
Relations
- Effective Date
- 19-Jan-2023
- Effective Date
- 28-Jun-2010
Get Certified
Connect with accredited certification bodies for this standard

ICC Evaluation Service
Building products evaluation and certification.

QAI Laboratories
Building and construction product testing and certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
EN 13859-2:2004+A1:2008 is a standard published by the European Committee for Standardization (CEN). Its full title is "Flexible sheets for waterproofing - Definitions and characteristics of underlays - Part 2: Underlays for walls". This standard covers: This document specifies the characteristics of flexible sheets for underlays for walls which are to be used in walls behind outside wall coverings in order to avoid penetration of wind and water from outside. It specifies the requirements and test methods and provides for the evaluation of conformity of the products with the requirements of this document.
This document specifies the characteristics of flexible sheets for underlays for walls which are to be used in walls behind outside wall coverings in order to avoid penetration of wind and water from outside. It specifies the requirements and test methods and provides for the evaluation of conformity of the products with the requirements of this document.
EN 13859-2:2004+A1:2008 is classified under the following ICS (International Classification for Standards) categories: 01.040.91 - Construction materials and building (Vocabularies); 91.100.50 - Binders. Sealing materials. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 13859-2:2004+A1:2008 has the following relationships with other standards: It is inter standard links to EN 13859-2:2004, EN 13859-2:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 13859-2:2004+A1:2008 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/102. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 13859-2:2004+A1:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Hidroizolacijski trakovi - Definicije in lastnosti podložnih folij - 2. del: Podložne folije za steneAbdichtungsbahnen - Definitionen und Eigenschaften von Unterdeck- und Unterspannbahnen - Teil 2: Unterdeck- und Unterspannbahnen für WändeFeuilles souples d'étanchéité - Définitions et caractéristiques des écrans souples - Partie 2: Ecrans souples pour murs extérieursFlexible sheets for waterproofing - Definitions and characteristics of underlays - Part 2: Underlays for walls91.100.50Veziva. Tesnilni materialiBinders. Sealing materials91.060.10Stene. Predelne stene. FasadeWalls. Partitions. Facades01.040.91Gradbeni materiali in gradnja (Slovarji)Construction materials and building (Vocabularies)ICS:Ta slovenski standard je istoveten z:EN 13859-2:2004+A1:2008SIST EN 13859-2:2005+A1:2009en,fr,de01-januar-2009SIST EN 13859-2:2005+A1:2009SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13859-2:2004+A1
October 2008 ICS 01.040.91; 91.100.50 Supersedes EN 13859-2:2004 English Version
Flexible sheets for waterproofing -Definitions and characteristics of underlays - Part 2: Underlays for walls
Feuilles souples d'étanchéité - Définitions et caractéristiques des écrans souples - Partie 2: Ecrans souples pour murs extérieurs
Abdichtungsbahnen - Definitionen und Eigenschaften von Unterdeck- und Unterspannbahnen - Teil 2: Unterdeck-und Unterspannbahnen für Wände This European Standard was approved by CEN on 20 October 2004 and includes Amendment 1 approved by CEN on 8 August 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2008 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13859-2:2004+A1:2008: ESIST EN 13859-2:2005+A1:2009
Determination of tensile properties.13 Annex B (normative)
Determination of resistance to tearing.16 Annex C (normative)
Artificial ageing by exposure to UV and heat.18 SIST EN 13859-2:2005+A1:2009
Initial type test and frequencies of testing for factory production control.21 Annex E (informative)
Example of a product data sheet.23 Annex ZA (informative)
Clauses of this European Standard addressing provision of the Construction Products Directive (CPD).25 Bibliography.32
3.2 manufacturer's limiting value (MLV) value stated by the manufacturer to be met during testing. The manufacturer's limiting value can be a minimum or a maximum value according to statements made under product characteristics of this document 3.3 manufacturer's declared value (MDV) value declared by the manufacturer accompanied by a declared tolerance 3.4 sampling procedure used to select or constitute a sample 3.5 sample sheet from which a test piece is taken 3.6 test piece part of the sample from which test specimens are taken 3.7 test specimen piece of precise dimensions taken from the test piece SIST EN 13859-2:2005+A1:2009
4.3 Application related characteristics 4.3.1 Reaction to fire Where required, the reaction to fire shall be determined in accordance with 5.2.2. 4.3.2 Resistance to water penetration 4.3.2.1 Class W1 The product shall be classified as resistant to water penetration Class W1 if it passes the resistance to water penetration test in accordance with 5.2.3. If the product fails the test of resistance to water penetration indicated in 5.2.3, it shall be tested in accordance with 4.3.2.2. 4.3.2.2 Class W2 A product failing to pass the test indicated in 5.2.3 shall be tested in accordance with 5.2.4. If the measured mean volume of water passing through the specimens tested is less than 100 ml, the product shall be classified as resistant to water penetration Class W2. 4.3.2.3 Class W3 If the product fails the test indicated in 4.3.2.2, e.g. the measured mean volume passing the specimens exceeds 100 ml, it shall be classified as resistant to water penetration Class W3. SIST EN 13859-2:2005+A1:2009
4.3.3 Water vapour transmission properties The product shall be tested in accordance with 5.2.5 and the results shall lie within the declared tolerance of the manufacturer’s declared value. Other measuring methods shall also be allowed if the correlation with 5.2.5 is proved and recorded. If the water vapour diffusion-equivalent air layer thickness sd is above or equal to 0,2 m the product shall be tested in accordance with 5.2.5.1. If the sd value is below 0,2 m the product shall be tested in accordance with 5.2.5.2. If the sd value is below 0,1 m the standard deviation s shall also be recorded in the test report. 4.3.4 Resistance to penetration of air The product shall be tested in accordance with 5.2.6. The test result shall be given as air permeability, expressed in m³ air per m², hour and 50 Pascals pressure difference (m³/(m² x h x 50 Pa)). The value of air permeability shall be equal to or lower than the manufacturer's limiting value. 4.3.5 Tensile properties The product shall be tested in accordance with 5.2.7 and the results shall lie within the declared tolerance of the manufacturer’s declared values for tensile strength and the maximum and/or minimum values for elongation for both longitudinal and transverse directions. 4.3.6 Resistance to tearing The resistance to tearing of underlays shall be tested in accordance with 5.2.8 and the results shall lie within the declared tolerance of the manufacturer's declared value in both (longitudinal and transverse) directions. 4.3.7 Dimensional stability The dimensional stability shall be determined in accordance with 5.2.9. 4.3.8 Flexibility at low temperature (pliability) Where appropriate, the flexibility at low temperature (pliability) determined in accordance with 5.2.10 shall be equal to or less than the manufacturer’s limiting value. 4.3.9 Artificial ageing behaviour The product shall be tested in accordance with 5.2.11. The mean values of tensile strength and elongation of the test specimens before and after artificial ageing shall be declared on the product data sheet by the manufacturer. The resistance to water penetration of artificially aged materials shall pass the same class declared by the manufacturer as defined in 4.3.2. For walls which do not exclude UV exposure, e.g. with open joints, the artificial ageing by UV shall be extended over a period of 5 000 h. NOTE "UV-exposed“ means that there are designed open joints in the wall covering which allow the penetration of daylight to reach the product. 4.4 Dangerous substances For products placed on the market within the European Economic Area see ZA.1. Outside the EEA products shall conform to any applicable provisions related to dangerous substances valid in the place of use. Underlays covered by this document shall not contain asbestos or coal tar constituents. The manufacturer shall disclose on the product wrapper and in the health and safety data sheets the use of any additive or constituent considered hazardous. SIST EN 13859-2:2005+A1:2009
If the intended use of the underlay is solely limited to being supported on a specific substrate, e. g. wood, mineral wool, polyurethane, it shall be tested in the end use application in accordance with EN 13238." 5.2.3 Determination of resistance to water penetration Class W1 The resistance to water penetration Class W1 shall be determined in accordance with !EN 1928:2000", Method A, with the modifications that: the water column shall be 200 mm; using water dyed with 0,05 % eosin (instead of a moisture indicating mixture of sugar and methylene blue); one layer of laboratory filter paper with a mass per unit area of 80 g/m²; test period: 2 h (instead of 24 h); three test specimens are used. 5.2.4 Determination of resistance to water penetration Class W2 The resistance to water penetration Class W2 shall be determined in accordance with EN 13111 using three test specimens. SIST EN 13859-2:2005+A1:2009
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.