Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance

This document specifies principles and testing procedures for determining, by means of the guarded hot plate or heat flow meter methods, the thermal resistance of dry test specimens having a thermal resistance of not less than 0,5 m2·K/W.
NOTE 1  The above limit is due to the effect of contact thermal resistances. An upper limit for measurable thermal resistance depends upon a number of factors described in this document, but a unique figure cannot be assigned.
It applies in principle to any mean test temperature, but the equipment design in Annex D is essentially intended to operate between a minimum cooling unit temperature of -100 °C and maximum heating unit temperature of +100 °C.
NOTE 2   Limits to the mean test temperature are only imposed by the materials used in the apparatus construction and by ancillary equipment.
This document does not supply general guidance and background information (e.g. the heat transfer property to be reported, product-dependent specimen preparations, procedures requiring multiple measurements, such as those to assess the effect of specimen non-homogeneities, those to test specimens whose thickness exceeds the apparatus capabilities, and those to assess the relevance of the thickness effect).
This document does not apply to cover measurements on moist products of any thermal resistance or measurements on thick products of high and medium thermal resistance.

Wärmetechnisches Verhalten von Baustoffen und Bauprodukten - Bestimmung des Wärmedurchlasswiderstandes nach dem Verfahren mit dem Plattengerät und dem Wärmestrommessplatten-Gerät - Produkte mit hohem und mittlerem Wärmedurchlasswiderstand

Dieses Dokument legt die Grundlagen und Prüfverfahren zur Bestimmung des Wärmedurchlasswiderstandes von trockenen Probekörpern mit einem Wärmedurchlasswiderstand von mindestens 0,5 m2 · K/W nach dem Verfahren mit dem Plattengerät und dem Wärmestrommessplatten-Gerät fest.
ANMERKUNG 1   Der oben genannte Grenzwert ist bedingt durch den Einfluss von Kontaktwärmewiderständen. Ein oberer Grenzwert für den messbaren Wärmedurchlasswiderstand hängt von einer Reihe von Faktoren ab, die in diesem Dokument beschrieben sind, wobei eine eindeutige Zahl jedoch nicht angegeben werden kann.
Es gilt grundsätzlich für alle mittleren Prüftemperaturen. Der Betrieb der Geräte, die nach Anhang D konstruiert wurden, ist im Wesentlichen für den Betrieb zwischen einer Mindesttemperatur der Kühlplatte von -100 °C und einer Höchsttemperatur der Heizplatte von +100 °C vorgesehen.
ANMERKUNG 2   Einschränkungen der mittleren Prüftemperatur ergeben sich nur durch die Werkstoffe, die für die Konstruktion der Geräte verwendet wurden, und durch die Zusatzgeräte.
Diese Norm enthält keine allgemeinen Hinweise und Hintergrundinformationen (z. B. über die anzugebende Wärmeübertragungseigenschaft, die produktabhängige Vorbereitung von Probekörpern, Verfahren, die Mehrfachmessungen erfordern, wie z. B. Verfahren zur Beurteilung des Einflusses von Inhomogenitäten von Probekörpern, Prüfverfahren für Probekörper, deren Dicke die Leistung der Geräte übersteigt, und Prüfverfahren zur Beurteilung des Einflusses der Dicke).
Dieses Dokument gilt nicht für Messungen an feuchten Produkten mit beliebigem Wärmedurchlasswiderstand oder Messungen an dicken Produkten mit hohem und mittlerem Wärmedurchlasswiderstand.

Performance thermique des matériaux et produits pour le bâtiment - Détermination de la résistance thermique par la méthode de la plaque chaude gardée et la méthode fluxmétrique - Produits de haute et moyenne résistance thermique

Le présent document spécifie les principes et les modes opératoires d’essai relatifs à la détermination, par les méthodes de la plaque chaude gardée ou fluxmétrique, la résistance thermique des éprouvettes d’essai ayant une résistance thermique d’au moins 0,5 m2·K/W.
NOTE 1 La limite ci dessus est due à l’influence des résistances thermiques de contact. Une limite supérieure de résistance thermique pouvant être mesurée dépend de plusieurs facteurs décrits dans le présent document, mais un nombre unique ne peut pas être donné.
Elle s’applique en principe à toute température moyenne d’essai, mais la conception d’équipement à l’Annexe D vise essentiellement un fonctionnement entre une température minimale de l’élément froid de -100 °C et une température maximale de l’élément chaud de +100 °C.
NOTE 2 Les limitations relatives à la température moyenne d’essai sont uniquement imposées par les matériaux utilisés dans la construction de l’appareil et par les équipements auxiliaires.
Le présent document ne fournit pas d’instructions générales ni d’informations de base (par exemple la propriété de transmission thermique à mentionner, les préparations des éprouvettes dépendantes des produits, les modes opératoires qui exigent des mesurages multiples, tels que ceux pour l’évaluation de l’effet des non homogénéités des éprouvettes, ceux pour l’essai d’éprouvettes dont l’épaisseur dépasse les capacités de l’appareil et ceux pour l’évaluation de la pertinence de l’effet d’épaisseur).
Le présent document ne s’applique pas aux mesurages de produits humides de résistance thermique quelconque ou aux mesurages de produits épais de haute et moyenne résistance thermique.

Toplotne karakteristike gradbenih materialov in proizvodov - Ugotavljanje toplotne upornosti z zaščiteno vročo ploščo in merilniki toplotnih tokov - Proizvodi z visoko in srednjo toplotno upornostjo

General Information

Status
Not Published
Publication Date
28-Feb-2027
Current Stage
4020 - Submission to enquiry - Enquiry
Start Date
16-Oct-2025
Due Date
12-Oct-2025
Completion Date
16-Oct-2025

Relations

Draft
prEN 12667:2025
English language
66 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2025
Toplotne karakteristike gradbenih materialov in proizvodov - Ugotavljanje toplotne
upornosti z zaščiteno vročo ploščo in merilniki toplotnih tokov - Proizvodi z
visoko in srednjo toplotno upornostjo
Thermal performance of building materials and products - Determination of thermal
resistance by means of guarded hot plate and heat flow meter methods - Products of
high and medium thermal resistance
Wärmetechnisches Verhalten von Baustoffen und Bauprodukten - Bestimmung des
Wärmedurchlasswiderstandes nach dem Verfahren mit dem Plattengerät und dem
Wärmestrommessplatten-Gerät - Produkte mit hohem und mittlerem
Wärmedurchlasswiderstand
Performance thermique des matériaux et produits pour le bâtiment - Détermination de la
résistance thermique par la méthode de la plaque chaude gardée et la méthode
fluxmétrique - Produits de haute et moyenne résistance thermique
Ta slovenski standard je istoveten z: prEN 12667
ICS:
91.100.60 Materiali za toplotno in Thermal and sound insulating
zvočno izolacijo materials
91.120.10 Toplotna izolacija stavb Thermal insulation of
buildings
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2025
ICS 91.100.01; 91.120.10 Will supersede EN 12667:2001
English Version
Thermal performance of building materials and products -
Determination of thermal resistance by means of guarded
hot plate and heat flow meter methods - Products of high
and medium thermal resistance
Performance thermique des matériaux et produits Wärmetechnisches Verhalten von Baustoffen und
pour le bâtiment - Détermination de la résistance Bauprodukten - Bestimmung des
thermique par la méthode de la plaque chaude gardée Wärmedurchlasswiderstandes nach dem Verfahren mit
et la méthode fluxmétrique - Produits de haute et dem Plattengerät und dem Wärmestrommessplatten-
moyenne résistance thermique Gerät - Produkte mit hohem und mittlerem
Wärmedurchlasswiderstand
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 89.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 12667:2025 E
worldwide for CEN national Members.

Contents Page
European foreword . 5
1 Scope . 6
2 Normative references . 6
3 Terms, definitions, symbols and units . 7
3.1 Terms and definitions . 7
3.1.1 certified reference material . 7
3.1.2 internal reference material: (stable with time, with moisture) . 7
3.1.3 hygroscopic material . 7
3.1.4 thermal conductivity, λ, at a point P . 7
3.1.5 thermally homogeneous medium . 7
3.1.6 porosity, ξ . 7
3.1.7 homogeneous porous medium . 8
3.1.8 thermally isotropic medium . 8
3.1.9 thermally stable medium . 8
3.1.10 mean thermal conductivity of a specimen . 8
3.1.11 transfer factor of a specimen . 8
3.1.12 thermal transmissivity of a material . 8
3.1.13 steady state heat transfer property . 9
3.1.14 settling time . 9
3.1.15 room temperature . 9
3.1.16 rigid specimen . 9
3.1.17 ambient temperature . 9
3.1.18 operator . 9
3.1.19 designer . 9
3.1.20 data user . 9
3.2 Symbols and units . 9
4 Principle . 10
4.1 Apparatus . 10
4.2 Measuring the density of heat flow rate . 10
4.3 Measuring the temperature difference . 10
4.4 Deriving the thermal resistance or transfer factor . 11
4.5 Computing thermal conductivity or thermal transmissivity . 11
4.6 Apparatus limits . 11
4.7 Specimen limits . 11
5 Apparatus . 11
5.1 General . 11
5.2 Guarded hot plate apparatus . 12
5.2.1 General . 12
5.2.2 Two specimen apparatus . 13
5.2.3 Single specimen apparatus . 13
5.2.4 Heating unit . 13
5.2.5 Metering area  . 13
5.2.6 Edge insulation and auxiliary guards . 13
5.2.7 Cooling units . 13
5.2.8 Accuracy and repeatability . 13
5.3 Heat flow meter apparatus . 14
5.3.1 General . 14
5.3.2 Heat flow meters . 14
5.3.3 Calibration principle . 14
5.3.4 Limitations due to the calibration . 15
5.3.5 Accuracy and repeatability . 15
6 Test specimens . 16
6.1 General . 16
6.2 Selection and size . 16
6.3 Specimen preparation . 16
6.3.1 Conformity with product standards . 16
6.3.2 All specimens except loose-fills . 16
6.3.3 Loose-fill materials . 17
6.3.4 Super insulation material . 17
7 Testing procedure . 17
7.1 General . 17
7.2 Conditioning . 18
7.3 Measurements . 18
7.3.1 Mass . 18
7.3.2 Thickness and density . 18
7.3.3 Temperature difference selection . 18
7.3.4 Ambient conditions . 18
7.3.5 Heat flow rate measurements . 19
7.3.6 Cold surface control (for two-specimen guarded hot plate apparatus) . 19
7.3.7 Temperature difference detection . 19
7.3.8 Settling time an
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.