ASTM D5993-18(2022)
(Test Method)Standard Test Method for Measuring Mass per Unit Area of Geosynthetic Clay Liners
Standard Test Method for Measuring Mass per Unit Area of Geosynthetic Clay Liners
SIGNIFICANCE AND USE
5.1 This test method is used to determine if the GCL material meets specifications for mass per unit area at approximately 0 % moisture content, by oven drying. It can be used as an index test for quality control or quality assurance to determine specimen conformance.
SCOPE
1.1 This test method covers the laboratory determination of the mass per unit area of a sample of a geosynthetic clay liner (GCL). The test method is also applicable to a multicomponent GCL. The dry mass of the clay can be found by simply subtracting the manufacturer's reported nominal mass of the geosynthetic component(s) from the total mass of the dry GCL. The moisture content of the GCL can also be determined by subtracting the initial total mass of the GCL from the total mass of the dry GCL.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 8 for specific precautionary statements.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
- Status
- Published
- Publication Date
- 30-Sep-2022
- Technical Committee
- D35 - Geosynthetics
- Drafting Committee
- D35.04 - Geosynthetic Clay Liners
Relations
- Effective Date
- 01-Feb-2024
- Effective Date
- 01-Feb-2024
- Effective Date
- 01-Mar-2019
- Effective Date
- 15-Apr-2018
- Effective Date
- 01-Aug-2017
- Effective Date
- 01-Mar-2017
- Effective Date
- 01-Feb-2017
- Effective Date
- 15-Sep-2015
- Effective Date
- 01-Sep-2015
- Effective Date
- 01-Sep-2015
- Effective Date
- 01-Jul-2015
- Effective Date
- 01-May-2015
- Effective Date
- 01-Apr-2015
- Effective Date
- 01-Mar-2014
- Effective Date
- 15-Jun-2013
Overview
ASTM D5993-18(2022), Standard Test Method for Measuring Mass per Unit Area of Geosynthetic Clay Liners, is an internationally recognized standard developed by ASTM International. This method provides a laboratory procedure to determine the mass per unit area of geosynthetic clay liners (GCLs), including multicomponent GCLs, at approximately 0% moisture content via oven drying. The test is primarily used for quality control and assurance processes in the manufacturing and application of GCLs, ensuring that products meet specific mass requirements and project specifications.
Geosynthetic clay liners are crucial hydraulic barriers composed of clay bonded to synthetic materials. Proper measurement of mass per unit area is essential because it directly impacts liner performance, durability, and conformance to regulatory and construction guidelines.
Key Topics
Mass per Unit Area Determination
This test method specifies the laboratory procedure for weighing oven-dried GCL specimens of known dimensions to obtain the mass per unit area. For multicomponent GCLs, the mass of the clay component is found by subtracting the manufacturer’s specified nominal mass of any synthetic component(s) from the total dry mass.Moisture Content Measurement
In addition to mass, ASTM D5993-18(2022) allows for determination of a GCL’s moisture content by comparing initial and post-drying masses. This provides valuable data for understanding product consistency.Quality Control and Quality Assurance
This standard serves as an index test, supporting quality control and assurance practices for GCL production, delivery, and installation. Results confirm material compliance with technical specifications.Sample Preparation and Equipment
Detailed guidance is provided on specimen selection, conditioning, cutting, and handling practices, as well as on the use of balances, ovens, and sample containers. Adherence to these requirements ensures test reliability and reproducibility.Safety Considerations
The standard includes important safety, health, and environmental precautions, emphasizing the proper handling of hot containers and adherence to equipment instructions, especially when using drying ovens or microwave ovens.
Applications
ASTM D5993-18(2022) is widely used in sectors where geosynthetic clay liners are implemented for environmental protection and containment applications. Key applications include:
Landfill Liners and Covers
Ensuring proper clay mass in GCLs is critical for effective landfill containment systems, preventing leachate migration and environmental contamination.Water Containment Projects
Used in ponds, canals, and reservoir lining, GCLs require rigorous testing to validate their hydraulic barrier properties, for which mass per unit area is a key metric.Civil and Environmental Engineering
Quality assurance for infrastructure projects, such as tunnels, dams, and erosion control systems, depends on reliable GCL components tested according to this ASTM standard.Manufacturing Quality Control
GCL manufacturers rely on this test method to certify product consistency and conformance to customer and regulatory requirements.
Related Standards
ASTM D5993-18(2022) references and complements several other standards relevant to geosynthetics:
- ASTM D4439 – Terminology for Geosynthetics
- ASTM D4643 – Test Method for Determination of Water Content of Soil and Rock by Microwave Oven Heating
- ASTM D4753 – Guide for Evaluating, Selecting, and Specifying Balances and Standard Masses for Use in Soil, Rock, and Construction Materials Testing
- ASTM E145 – Specification for Gravity-Convection and Forced-Ventilation Ovens
- ASTM E691 – Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
These related standards provide terminology, equipment specifications, and procedural guidance supporting accurate and consistent measurement of mass per unit area in geosynthetic clay liners.
Keywords: geosynthetic clay liner, GCL, mass per unit area, ASTM D5993-18(2022), quality control, moisture content, hydraulic barrier, geosynthetics testing, liner manufacturing, environmental containment standards.
Buy Documents
ASTM D5993-18(2022) - Standard Test Method for Measuring Mass per Unit Area of Geosynthetic Clay Liners
Get Certified
Connect with accredited certification bodies for this standard
DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
ASTM D5993-18(2022) is a standard published by ASTM International. Its full title is "Standard Test Method for Measuring Mass per Unit Area of Geosynthetic Clay Liners". This standard covers: SIGNIFICANCE AND USE 5.1 This test method is used to determine if the GCL material meets specifications for mass per unit area at approximately 0 % moisture content, by oven drying. It can be used as an index test for quality control or quality assurance to determine specimen conformance. SCOPE 1.1 This test method covers the laboratory determination of the mass per unit area of a sample of a geosynthetic clay liner (GCL). The test method is also applicable to a multicomponent GCL. The dry mass of the clay can be found by simply subtracting the manufacturer's reported nominal mass of the geosynthetic component(s) from the total mass of the dry GCL. The moisture content of the GCL can also be determined by subtracting the initial total mass of the GCL from the total mass of the dry GCL. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 8 for specific precautionary statements. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
SIGNIFICANCE AND USE 5.1 This test method is used to determine if the GCL material meets specifications for mass per unit area at approximately 0 % moisture content, by oven drying. It can be used as an index test for quality control or quality assurance to determine specimen conformance. SCOPE 1.1 This test method covers the laboratory determination of the mass per unit area of a sample of a geosynthetic clay liner (GCL). The test method is also applicable to a multicomponent GCL. The dry mass of the clay can be found by simply subtracting the manufacturer's reported nominal mass of the geosynthetic component(s) from the total mass of the dry GCL. The moisture content of the GCL can also be determined by subtracting the initial total mass of the GCL from the total mass of the dry GCL. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 8 for specific precautionary statements. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D5993-18(2022) is classified under the following ICS (International Classification for Standards) categories: 91.100.15 - Mineral materials and products. The ICS classification helps identify the subject area and facilitates finding related standards.
ASTM D5993-18(2022) has the following relationships with other standards: It is inter standard links to ASTM D4439-24, ASTM D4753-24, ASTM E145-19, ASTM D4439-18, ASTM D4439-17, ASTM D123-17, ASTM D4643-17, ASTM D123-15b, ASTM D123-15a, ASTM D4439-15a, ASTM D4439-15, ASTM D4753-15, ASTM D123-15, ASTM D4439-14, ASTM D123-13ae1. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ASTM D5993-18(2022) is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D5993 − 18 (Reapproved 2022)
Standard Test Method for
Measuring Mass per Unit Area of Geosynthetic Clay Liners
This standard is issued under the fixed designation D5993; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope ances and Standard Masses for Use in Soil, Rock, and
Construction Materials Testing
1.1 This test method covers the laboratory determination of
E145Specification for Gravity-Convection and Forced-
the mass per unit area of a sample of a geosynthetic clay liner
Ventilation Ovens
(GCL).Thetestmethodisalsoapplicabletoamulticomponent
E691Practice for Conducting an Interlaboratory Study to
GCL. The dry mass of the clay can be found by simply
Determine the Precision of a Test Method
subtracting the manufacturer’s reported nominal mass of the
geosyntheticcomponent(s)fromthetotalmassofthedryGCL.
3. Terminology
The moisture content of the GCL can also be determined by
3.1 Definitions:
subtractingtheinitialtotalmassoftheGCLfromthetotalmass
3.1.1 geosynthetic, n—a planar product manufactured from
of the dry GCL.
polymeric material used with soil, rock, earth, or other geo-
1.2 The values stated in SI units are to be regarded as
technical engineering-related material as an integral part of a
standard. No other units of measurement are included in this
manmade project, structure, or system. D4439
standard.
3.1.2 geosynthetic clay liner, n—a manufactured hydraulic
1.3 This standard does not purport to address all of the
barrier consisting of clay bonded to a layer or layers of
safety concerns, if any, associated with its use. It is the
geosynthetic material(s).
responsibility of the user of this standard to establish appro-
3.1.3 moisture content, n—that part of the mass of a
priate safety, health, and environmental practices and deter-
geosynthetic clay liner that is absorbed water, compared to the
mine the applicability of regulatory limitations prior to use.
mass of dry clay.
See Section 8 for specific precautionary statements.
3.1.4 multicomponent GCL, n—GCL with an attached film,
1.4 This international standard was developed in accor-
coating, or membrane decreasing the hydraulic conductivity or
dance with internationally recognized principles on standard-
protecting the clay core, or both.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
3.1.5 oven-dried, adj—the condition of a material that has
mendations issued by the World Trade Organization Technical
been heated under prescribed conditions of temperature and
Barriers to Trade (TBT) Committee.
humidityuntilthereisnofurthersignificantchangeinitsmass.
D123
2. Referenced Documents
2 4. Summary of Test Method
2.1 ASTM Standards:
D123Terminology Relating to Textiles
4.1 The mass per unit area is determined by weighing
D4439Terminology for Geosynthetics (oven-dried) specimens of known initial size after drying in an
D4643Test Method for Determination of Water Content of ovenoverasufficienttimeperiodtoremovethemoisturefrom
Soil and Rock by Microwave Oven Heating the GCL.
D4753Guide for Evaluating, Selecting, and Specifying Bal-
4.2 The mass per unit area of the clay component of the
GCL can be estimated by subtracting the manufacturer’s
reported nominal mass per unit area of the synthetic compo-
This test method is under the jurisdiction of ASTM Committee D35 on
nent(s)and,ifadded,anyadditionalcomponents(forexample,
Geosynthetics and is the direct responsibility of Subcommittee D35.04 on Geosyn-
sand, bituminous layer, etc.) from the total GCLmass per unit
thetic Clay Liners.
Current edition approved Oct. 1, 2022. Published October 2022. Originally area.
approved in 1996. Last previous edition approved in 2018 as D5993–18. DOI:
NOTE 1—The supplier of the geosynthetic clay liner must be able to
10.1520/D5993-18R22.
verify that the actual mass/unit area of the synthetic component(s) is
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
within 610% of the reported nominal value.Amore accurate estimation
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on of the actual dry clay mass per unit area could be obtained by using the
the ASTM website. actual average value for the synthetic component(s) (as obtained from the
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D5993 − 18 (2022)
manufacturer for the actual lots used to make the GCL) rather than the
8. Hazards/Precautions
nominal value.
8.1 Handle hot containers with a container holder.
NOTE 2—The supplier of the geosynthetic clay liner must be able to
verify that the actual mass/area of the additional components is with
8.2 Safety precautions supplied by the manufacturer of the
610% of the reported nominal value.
microwave oven should be observed.
4.3 The moisture content of the GCLcan be estimated with
8.3 Do not use metallic containers in a microwave oven (if
this test method.
used).
5. Significance and Use
9. Test Specimens
5.1 This test method is used to determine if the GCL
material meets specifications for mass per unit area at approxi-
9.1 The sample received at the testing laboratory should be
mately0%moisturecontent,byovendrying.Itcanbeusedas
in satisfactory condition and representative of the product
an index test for quality control or quality assurance to
manufactured or delivered to a site, or both.
determine specimen conformance.
9.2 A sample of a GCL should be cut into specimens in a
laboratory using a die or sharp razor blade or razor knife.
6. Atmosphere Conditions
6.1 Atmospheric Conditions: 9.3 The minimum size of the die or template for cutting
6.1.1 Theatmosphericconditionsofthelaboratoryperform- specimens is 0.01 m (for example, 10cm by 10 cm).
ing mass per unit area of GCLs shall be: relative humidity of
NOTE 4—The use of small specimens are not recommended due to the
≤70% and temperature of 23°C 6 4°C.
potential for edge loss of clay, which may create problems with accuracy
and reproducibility.
7. Apparatus
9.4 Testspecimenstakenfromthelaboratorysampleshould
7.1 Drying Oven—Thermostatically controlled, preferably
be free from imperfections or other areas not representative of
of the forced-draft type, meeting the requirements of Specifi-
the material samples (such as dirt or labels).
cation E145 and capable of maintaining a uniform temperature
9.5 Cutting of the laboratory specimens with a die or razor
of 110°C 6 5°C throughout the drying chamber.
may contaminate the work area, die, or razor with particles of
7.2 Microwave Oven—Amicrowaveoven,preferablywitha
clayorgeosyntheticmaterial.Theworkareashouldbecleaned
ventedchamber,issuitable.Therequiredsizeandpowerrating
before cutting the specimen. Therefore, all excess or waste
of the oven is dependent on its intended use. Ovens with
material should be cleaned away from the die and cutting area
variable power controls and input power ratings of about
beforeremovalofthespecimen.Thespecimen,materialonthe
700W have been found to be adequate for this use. Variable
die, and cutting area should be placed into a tared container.
power controls are important and reduce the potential for
Wiping of the area should be performed with a non-clinging
overheating the test specimen.
cloth or brush.
NOTE 3—Microwave ovens equipped with built-in scales and computer
9.6 The loss of clay during the specimen cutting process
controls have been developed for use in drying soils. Their use is
could have a significant impact to the accuracy of this test
compatible with this test method.
method. The technician performing this test method should
7.3 Balances—All balances must meet the requirements of
practicecuttingtestspecimensfromthelaboratorysampleuntil
Guide D4753 and this section.AClass GP1 balance of 0.01-g
confidence is gained that a specimen can be cut without
readabilityisrequiredforsampleshavingamassofupto200g
significant loss of clay.
(excludingmassofsamplecontainer)andaClassGP2balance
9.6.1 Thetechnicianmaychoosetowettheperimeterofthe
of 0.1-g readability is required for samples having a mass over
GCLinanefforttobindtheclayparticlestogether,andthereby
200 g.
reduce the possibility of clay granule loss during the cutting
7.4 Sample Containers—Suitable containers made of mate-
process. If the sample is wetted, the technician should try to
rial resistant to corrosion and change in mass upon repeated
limittheamountofclaythatwillattachitselftothedie,cutting
heating, cooling, exposure to materials of varying pH, and
board, template, or cutting instrument, or combination thereof.
cleaning. Microwave sample containers should be microwave
However, if the technician is attempting to determine the
safe.
moisture content of the GCL, other cutting methods should be
used that do not require the addition of water.
7.5 Desiccator—Adesiccator cabinet or large desiccator jar
ofsuitablesizecontainingindicatorsilicagel.Itispreferableto 9.6.2 Ifadieisusedtocutthespecimen,lossofclaycanbe
use a desiccant that changes color to indicate it needs recon- reduced by leaving the die in place and removing all the
stitution. remaining sample outside the edge of the die. This includes
brushing the cutting board clean.All material found within the
7.6 Container Handling Apparatus—Gloves, tongs, or suit-
edge of the die could then be placed in the sample containers.
able holder for moving and handling hot con
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...