Standard Guide for Conducting Lead Hazard Assessments of Dwellings and of Other Child-Occupied Facilities

SIGNIFICANCE AND USE
5.1 This guide is intended to help prevent lead poisoning of children by providing standardized procedures for conducting a lead hazard assessment and providing information needed to develop and recommend lead hazard control options as described in Practice E2252.  
5.2 This guide is applicable for use in either occupied or unoccupied dwellings and in other child-occupied facilities.  
5.3 The procedures in this guide, when supplemented by recommendations for controlling lead hazards, provide for the conduct of a lead risk assessment of a dwelling or of other child-occupied facilities.  
5.4 This guide may be used to supplement assessment procedures used to determine the causes of elevated blood lead (EBL) levels in young children.
Note 2: In cases of EBL levels, investigation of the total living environment of the child and a pediatric medical evaluation may also be needed. Reference should be made to documents such as Managing Elevated Blood Lead Levels Among Young Children,6 Preventing Lead Poisoning in Young Children (1991),7 the HUD Guidelines, and Screening Young Children for Lead Poisoning (1997).7  
5.5 Although this guide was developed for dwellings and for other child-occupied facilities, this guide may be suitable for lead hazard assessments in non-residential buildings and other properties following agreement between assessor and client on appropriate lead action levels.  
5.6 This guide is not intended for use in identifying building materials that when abraded or otherwise degraded, such as that which may occur in remodeling or renovation activities, may result in lead hazards.  
5.7 Lead hazard assessment reports describe lead hazards identified at the time the assessment was performed. The locations, types, or severities of lead hazards can change over time as a result of property improvement or deterioration, significant changes in property use, or other factors.
Note 3: The term “lead-free” should never be used to describe the absence of ...
SCOPE
1.1 This guide covers how to conduct, document, and report findings of a lead hazard assessment of dwellings and of other child-occupied facilities.  
1.2 Procedures for assessment of personal items, such as toys, dishes, and hobby materials that may contribute to elevated lead levels in blood are not included in this guide.  
1.3 Procedures for random sampling of units within dwellings having multiple units are not included.  
1.4 This guide contains notes, which are explanatory, and are not part of the mandatory requirements of this guide.  
1.5 The values stated in SI units are to be regarded as the standard.  
1.5.1 Exception—The inch-pound and SI units shown for wipe sampling data are to be individually regarded as standard for wipe sampling data.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
31-Oct-2019
Current Stage
Ref Project

Buy Standard

Guide
ASTM E2115-19 - Standard Guide for Conducting Lead Hazard Assessments of Dwellings and of Other Child-Occupied Facilities
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview
Guide
REDLINE ASTM E2115-19 - Standard Guide for Conducting Lead Hazard Assessments of Dwellings and of Other Child-Occupied Facilities
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E2115 − 19
Standard Guide for
Conducting Lead Hazard Assessments of Dwellings and of
1
Other Child-Occupied Facilities
This standard is issued under the fixed designation E2115; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D4840 Guide for Sample Chain-of-Custody Procedures
E631 Terminology of Building Constructions
1.1 This guide covers how to conduct, document, and report
E1583 Practice for Evaluating Laboratories Engaged in De-
findings of a lead hazard assessment of dwellings and of other
termination of Lead in Paint, Dust, Airborne Particulates,
child-occupied facilities.
and Soil Taken From and Around Buildings and Related
1.2 Procedures for assessment of personal items, such as
Structures
toys, dishes, and hobby materials that may contribute to
E1605 Terminology Relating to Lead in Buildings
elevated lead levels in blood are not included in this guide.
E1613 Test Method for Determination of Lead by Induc-
1.3 Procedures for random sampling of units within dwell- tively Coupled Plasma Atomic Emission Spectrometry
(ICP-AES), Flame Atomic Absorption Spectrometry
ings having multiple units are not included.
(FAAS), or Graphite Furnace Atomic Absorption Spec-
1.4 This guide contains notes, which are explanatory, and
trometry (GFAAS) Techniques
are not part of the mandatory requirements of this guide.
E1644 Practice for Hot Plate Digestion of Dust Wipe
1.5 The values stated in SI units are to be regarded as the
Samples for the Determination of Lead
standard.
E1645 Practice for Preparation of Dried Paint Samples by
1.5.1 Exception—The inch-pound and SI units shown for
Hotplate or Microwave Digestion for Subsequent Lead
wipe sampling data are to be individually regarded as standard
Analysis
for wipe sampling data.
E1726 Practice for Preparation of Soil Samples by Hotplate
1.6 This standard does not purport to address all of the Digestion for Subsequent Lead Analysis
safety concerns, if any, associated with its use. It is the E1727 Practice for Field Collection of Soil Samples for
responsibility of the user of this standard to establish appro- Subsequent Lead Determination
priate safety, health, and environmental practices and deter- E1728/E1728M Practice for Collection of Settled Dust
mine the applicability of regulatory limitations prior to use. Samples Using Wipe Sampling Methods for Subsequent
1.7 This international standard was developed in accor- Lead Determination
dance with internationally recognized principles on standard- E1729 Practice for Field Collection of Dried Paint Samples
ization established in the Decision on Principles for the for Subsequent Lead Determination
Development of International Standards, Guides and Recom- E1753 Practice for Use of Qualitative Chemical Spot Test
mendations issued by the World Trade Organization Technical Kits for Detection of Lead in Dry Paint Films
Barriers to Trade (TBT) Committee. E1979 Practice for Ultrasonic Extraction of Paint, Dust,
Soil, and Air Samples for Subsequent Determination of
2. Referenced Documents
Lead
2
2.1 ASTM Standards:
E2051 Practice for the Determination of Lead in Paint,
D1356 Terminology Relating to Sampling and Analysis of
Settled Dust, Soil and Air Particulate by Field-Portable
3
Atmospheres
Electroanalysis (Withdrawn 2010)
E2119 Practice for Quality Systems for Conducting In Situ
1
This guide is under the jurisdiction of ASTM Committee D22 on Air Quality
Measurements of Lead Content in Paint or Other Coatings
and is the direct responsibility of Subcommittee D22.12 on Sampling andAnalysis,
Using Field-Portable X-Ray Fluorescence (XRF) Devices
of Lead, for Exposure and Risk Assessment.
E2239 PracticeforRecordKeepingandRecordPreservation
Current edition approved Nov. 1, 2019. Published November 2019. Originally
approved in 2000. Last previous edition approved in 2015 as E2115 – 15. DOI: for Lead Hazard Activities
10.1520/E2115-19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on The last approved version of this historical standard is referenced on
the ASTM website. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2115 − 19
E2252 Practice for Selection of Lead Hazard Reduction 5.3 The procedures in this guide, when supplemented by
Methods for Identified Risks in Residential Housing or rec
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E2115 − 15 E2115 − 19
Standard Guide for
Conducting Lead Hazard Assessments of Dwellings and of
1
Other Child-Occupied Facilities
This standard is issued under the fixed designation E2115; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This guide covers how to conduct, document, and report findings of a lead hazard assessment of dwellings and of other
child-occupied facilities.
1.2 Procedures for assessment of personal items, such as toys, dishes, and hobby materials that may contribute to elevated lead
levels in blood are not included in this guide.
1.3 Procedures for random sampling of units within dwellings having multiple units are not included.
1.4 This guide contains notes, which are explanatory, and are not part of the mandatory requirements of this guide.
1.5 The values stated in SI units are to be regarded as the standard.
1.5.1 Exception—The inch-pound and SI units shown for wipe sampling data are to be individually regarded as standard for
wipe sampling data.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory requirementslimitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
D4840 Guide for Sample Chain-of-Custody Procedures
E631 Terminology of Building Constructions
E1583 Practice for Evaluating Laboratories Engaged in Determination of Lead in Paint, Dust, Airborne Particulates, and Soil
Taken From and Around Buildings and Related Structures
E1605 Terminology Relating to Lead in Buildings
E1613 Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES),
Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques
E1644 Practice for Hot Plate Digestion of Dust Wipe Samples for the Determination of Lead
E1645 Practice for Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis
E1726 Practice for Preparation of Soil Samples by Hotplate Digestion for Subsequent Lead Analysis
E1727 Practice for Field Collection of Soil Samples for Subsequent Lead Determination
E1728E1728/E1728M Practice for Collection of Settled Dust Samples Using Wipe Sampling Methods for Subsequent Lead
Determination
E1729 Practice for Field Collection of Dried Paint Samples for Subsequent Lead Determination
E1753 Practice for Use of Qualitative Chemical Spot Test Kits for Detection of Lead in Dry Paint Films
1
This guide is under the jurisdiction of ASTM Committee D22 on Air Quality and is the direct responsibility of Subcommittee D22.12 on Sampling and Analysis, of Lead,
for Exposure and Risk Assessment.
Current edition approved May 1, 2015Nov. 1, 2019. Published July 2015November 2019. Originally approved in 2000. Last previous edition approved in 20062015 as
E2115 – 06E2115 – 15. which was withdrawn January 2015 and reinstated in May 2015. DOI: 10.1520/E2115-15.DOI: 10.1520/E2115-19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’sstandard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2115 − 19
E1979 Practice for Ultrasonic Extraction of Paint, Dust, Soil, and Air Samples for Subsequent Determination of Lead
E2051 Practice for the Determination of Lead in Paint, Settled Dust, Soil and Air Particulate by Field-Portable Electroanalysis
3
(Withdrawn 2010)
E2119 Practice for Quality Systems for Conducting In Situ Measurements
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.