SIST EN 4612-011:2019
(Main)Aerospace series - Cables, electrical, for general purpose, single and multicore assembly XLETFE Family jacketed or screened and jacketed - Part 011: Nickel plated copper - Operating temperatures, between − 65 °C and 150 °C - Dual extruded wall for open applications, with jacket without screen - UV laser printable - Product standard
Aerospace series - Cables, electrical, for general purpose, single and multicore assembly XLETFE Family jacketed or screened and jacketed - Part 011: Nickel plated copper - Operating temperatures, between − 65 °C and 150 °C - Dual extruded wall for open applications, with jacket without screen - UV laser printable - Product standard
This document specifies the characteristics of UV laser printable jacket, nickel plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer XLETFE family for use in the onboard electrical systems of aircraft at operating temperatures between - 65 °C and 150 °C, operating at voltages not exceeding 600 V. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user.
These cables are suitable for airframe use without additional protection.
In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.
Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - mit Mantel oder geschirmt und Mantel - Teil 011: Kupfer vernickelt - Betriebstemperaturen zwischen - 65 °C und 150 °C - Doppelt extrudierte Isolierung für externe Verwendung, mit Mantel ohne Schirm (Geflecht) - UV-Laser bedruckbar - Produktnorm
Dieses Dokument legt die Eigenschaften von elektrischen Leitungen mit UV Laser bedruckbarem Mantel, mit vernickeltem Kupferleiter, aus der XLETFE Familie (quervernetztes Ethylen Tetrafluorethylen Co Polymer) zur Verwendung in elektrischen Bordnetzen von Luftfahrzeugen bei Betriebstemperaturen zwischen −65 °C und 150 °C und Betriebsspannungen bis 600 V fest. Dieses Isoliersystem wurde bei Luft und Raumfahrtan¬wendungen mit 115 V (Phase gegen Neutral), 400 Hz Wechselspannung und 28 V Gleichspannung angewen¬det. Der Anwender ist für den Nachweis der Eignung von Leitungen zur Anwendung in anderen elektrischen Systemen verantwortlich.
Diese Leitungen sind für die Verlegung in Luftfahrzeugzellen ohne Zusatzschutz geeignet.
Bei Widersprüchen zwischen dieser Norm und anderen zitierten Dokumenten gelten die Anforderungen die¬ser Norm.
Série aérospatiale Câbles, électriques, d'usage général, mono et multiconducteurs Famille XLETFE Gainés ou blindés et gainés Partie 011 : Cuivre nickelé Températures de fonctionnement comprises entre - 65 °C et 150 °C Fil double isolé pour applications externes, gainé et non blindé Marquable au laser UV Norme de produit
Le présent document spécifie les caractéristiques des câbles électriques conducteurs en cuivre nickelé gainés, marquables au laser UV, de la famille des copolymères d'éthylène tétra-fluoro éthylène réticulés (XLETFE), utilisés dans les systèmes électriques de bord des aéronefs à une température de fonctionnement comprise entre - 65 °C et 150 °C, à des tensions n’excédant pas 600 V. Ce système isolant est employé dans les applications aérospatiales utilisant une tension simple de 115 V (phase-neutre) 400 Hz ca et 28 V cc. Il est de la responsabilité de l'utilisateur de vérifier si les câbles sont utilisables dans d'autres systèmes électriques.
Ces câbles sont utilisables en cellule sans protection supplémentaire.
En cas de conflit entre cette norme et d'autres documents de référence, les exigences de la présente norme doivent prévaloir.
Aeronavtika - Kabli, električni, za splošne namene, eno- in večžilni - Družina XLETFE - Oplaščeni ali zaslonjeni in oplaščeni - 011. del: Ponikljani baker - Obratovalne temperature med –65 °C in 135 °C - Dvojno ekstrudirana izolacija za zunanjo uporabo, s plaščem brez zaslona - Potiskljiva z UV-laserjem - Standard za proizvod
Ta dokument določa lastnosti električnih oplaščenih kablov, potiskljivih z UV-laserjem, z vodnikom iz ponikljanega bakra iz družine kopolimerov, pridobljenih z mrežno polimerizacijo etilena in tetrafluoroetilena (XLETFE), za uporabo v električnih sistemih na krovu letal pri obratovalnih temperaturah med –65 °C in 150 °C in obratovalnih napetostih, ki ne presegajo 600 V RMS na morski gladini. Ta izolacijski sistem se je uporabljal v aeronavtiki pri izmenični napetosti 115 V (za fazno napetost) pri 400 Hz in 28 V pri enosmerni napetosti. Za preverjanje ustreznosti kablov za uporabo v drugih električnih sistemih je odgovoren uporabnik. Ti kabli so primerni za uporabo na ogrodjih letal brez dodatne zaščite. V primeru neskladja med tem standardom in drugimi navedenimi dokumenti imajo prednost določila tega standarda.
General Information
- Status
- Published
- Publication Date
- 30-Sep-2019
- Technical Committee
- I13 - Imaginarni 13
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 06-Sep-2019
- Due Date
- 11-Nov-2019
- Completion Date
- 01-Oct-2019
Relations
- Effective Date
- 04-Sep-2019
- Effective Date
- 29-Sep-2016
Overview
EN 4612-011:2019 is a CEN product standard in the aerospace series that specifies the characteristics of XLETFE family electrical cables with a UV laser printable jacket and nickel‑plated copper conductors. It covers single- and multi‑core jacketed (non‑screened) assemblies intended for aircraft onboard electrical systems operating between −65 °C and 150 °C and at voltages up to 600 V. The insulation/jacket system is crosslinked ETFE (XLETFE) with a dual‑extruded wall for open applications and is suitable for airframe use without additional protection.
Key topics and technical requirements
- Construction
- Cores: nickel‑plated copper, 2 to 4 cores, twisted per EN 2235; filler cores not permitted.
- Outer jacket: XLETFE, UV laser printable, minimum thickness 0.15 mm.
- Dual extruded wall for external/open applications.
- Electrical and mechanical data
- Designed for typical aerospace systems (examples noted: 115 V phase‑to‑neutral 400 Hz AC and 28 V DC); verification for other systems is the user's responsibility.
- Maximum operating voltage: 600 V.
- Tableed conductor sizes, diameters, mass and DC resistance are provided (see standard Table 1).
- Testing and performance
- Referenced test methods largely from EN 3475‑100 and EN 2235.
- Applicable tests include visual, mass, dimensions, ohmic resistance, accelerated ageing (200 ± 3 °C), shrinkage/delamination (150 ± 5 °C), thermal shock (−65 °C / 150 °C), cold bend (−65 ± 2 °C), bending, flammability (flame 15 s; extinguish ≤ 3 s), resistance to fluids (volume swell ≤ 10 %), humidity resistance (90 °C, 672 h), tensile properties of extruded materials (TS ≥ 35 MPa, Eb ≥ 75 %), flexure endurance (mandrel Ø15 mm, 0.75 kg, 750 cycles), strippability and laser markability (contrast K ≥ 50 %).
- Quality and marking
- Quality assurance per EN 9133.
- Identification, colour coding and designation formats per EN 4612‑002 and EN 2235.
Applications and users
- Intended for aerospace airframe wiring harnesses where high temperature range, UV laser marking for traceability, and robust XLETFE jackets are required.
- Primary users:
- Cable manufacturers and suppliers producing aviation-grade wiring.
- Aircraft electrical/system designers and avionics engineers specifying harness materials.
- Procurement, quality and certification teams verifying compliance for installation and maintenance.
- MRO and wiring installation teams needing laser‑printable, high‑temperature external cables.
- Note: users must verify suitability in electrical systems beyond the examples cited.
Related standards
- EN 4612‑002 (general XLETFE product requirements)
- EN 4611‑004 (tin plated copper variant)
- EN 2235 (technical specification for single/multicore screened/jacketed cables)
- EN 3475‑100 (cable test methods)
- EN 9133 (quality management and product qualification)
Keywords: EN 4612‑011:2019, aerospace cables, XLETFE, nickel plated copper, UV laser printable, aircraft wiring, operating temperatures −65 °C to 150 °C.
Frequently Asked Questions
SIST EN 4612-011:2019 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Aerospace series - Cables, electrical, for general purpose, single and multicore assembly XLETFE Family jacketed or screened and jacketed - Part 011: Nickel plated copper - Operating temperatures, between − 65 °C and 150 °C - Dual extruded wall for open applications, with jacket without screen - UV laser printable - Product standard". This standard covers: This document specifies the characteristics of UV laser printable jacket, nickel plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer XLETFE family for use in the onboard electrical systems of aircraft at operating temperatures between - 65 °C and 150 °C, operating at voltages not exceeding 600 V. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user. These cables are suitable for airframe use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.
This document specifies the characteristics of UV laser printable jacket, nickel plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer XLETFE family for use in the onboard electrical systems of aircraft at operating temperatures between - 65 °C and 150 °C, operating at voltages not exceeding 600 V. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user. These cables are suitable for airframe use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.
SIST EN 4612-011:2019 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables; 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 4612-011:2019 has the following relationships with other standards: It is inter standard links to SIST EN 4612-011:2012, SIST EN 4612-011:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 4612-011:2019 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2019
Nadomešča:
SIST EN 4612-011:2012
Aeronavtika - Kabli, električni, za splošne namene, eno- in večžilni - Družina
XLETFE - Oplaščeni ali zaslonjeni in oplaščeni - 011. del: Ponikljani baker -
Obratovalne temperature med –65 °C in 135 °C - Dvojno ekstrudirana izolacija za
zunanjo uporabo, s plaščem brez zaslona - Potiskljiva z UV-laserjem - Standard za
proizvod
Aerospace series - Cables, electrical, for general purpose, single and multicore
assembly XLETFE Family jacketed or screened and jacketed - Part 011: Nickel plated
copper - Operating temperatures, between − 65 °C and 150 °C - Dual extruded wall for
open applications, with jacket without screen - UV laser printable - Product standard
Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine
Verwendung - XLETFE Familie - mit Mantel oder geschirmt und Mantel - Teil 011: Kupfer
vernickelt - Betriebstemperaturen zwischen - 65 °C und 150 °C - Doppelt extrudierte
Isolierung für externe Verwendung, mit Mantel ohne Schirm (Geflecht) - UV-Laser
bedruckbar - Produktnorm
Série aérospatiale Câbles, électriques, d'usage général, mono et multiconducteurs
Famille XLETFE Gainés ou blindés et gainés Partie 011 : Cuivre nickelé Températures
de fonctionnement comprises entre - 65 °C et 150 °C Fil double isolé pour applications
externes, gainé et non blindé Marquable au laser UV Norme de produit
Ta slovenski standard je istoveten z: EN 4612-011:2019
ICS:
29.060.20 Kabli Cables
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 4612-011
EUROPEAN STANDARD
NORME EUROPÉENNE
August 2019
EUROPÄISCHE NORM
ICS 49.060 Supersedes EN 4612-011:2011
English Version
Aerospace series - Cables, electrical, for general purpose,
single and multicore assembly - XLETFE Family - Jacketed
or screened and jacketed - Part 011: Nickel plated copper -
Operating temperatures, between - 65 °C and 150 °C - Dual
extruded wall for open applications, with jacket without
screen - UV laser printable - Product standard
Série aérospatiale - Câbles, électriques, d'usage Luft- und Raumfahrt - Ein- und mehradrige elektrische
général, mono et multiconducteurs - Famille XLETFE - Leitungen für allgemeine Verwendung - XLETFE
Gainés ou blindés et gainés - Partie 011 : Cuivre nickelé Familie - mit Mantel oder geschirmt und Mantel - Teil
- Températures de fonctionnement comprises entre - 011: Kupfer vernickelt - Betriebstemperaturen
65 °C et 150 °C - Fil double isolé pour applications zwischen - 65 °C und 150 °C - Doppelt extrudierte
externes, gainé et non blindé - Marquable au laser UV - Isolierung für externe Verwendung, mit Mantel ohne
Norme de produit Schirm (Geflecht) - UV-Laser bedruckbar -
Produktnorm
This European Standard was approved by CEN on 5 May 2019.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 4612-011:2019 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Materials . 5
5 Required characteristics . 6
6 Quality assurance . 8
7 Designation . 8
8 Identification and marking . 8
9 Packaging, labelling and delivery lengths . 8
10 Technical specification . 8
European foreword
This document (EN 4612-011:2019) has been prepared by the Aerospace and Defence Industries
Association of Europe - Standardization (ASD-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has
received the approval of the National Associations and the Official Services of the member countries of
ASD, prior to its presentation to CEN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by February 2020, and conflicting national standards shall
be withdrawn at the latest by February 2020.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 4612-011:2011.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Ne
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...