Paper and board -- Determination of CIE whiteness, C/2 degrees (indoor illumination conditions)

ISO 11476:2010 specifies the procedure to be used for determining the CIE whiteness of papers and boards, in order to obtain values which correspond to the visual appearance of white papers and boards, with or without fluorescent whitening agents, when they are viewed indoors. It is based on radiance factor data obtained over the full visible spectral range (VIS) in contrast to the measurement of ISO brightness, which is limited to the blue region of VIS. ISO 11476:2010 also specifies the procedures for the determination of CIE tint values and the fluorescent component of CIE whiteness.
In addition, it specifies a method for adjustment of the UV content to correspond to that of CIE illuminant C, since the results obtained when fluorescent whitening agents are present are dependent upon the UV content of the radiation falling upon the sample. The CIE illuminant C is taken to be representative of indoor illumination conditions because it contains a suitable proportion of UV radiation. This method is not applicable to coloured papers containing fluorescent dyes. It is specific to the situation where the fluorescence occurs in the blue region of the visible spectral range.
ISO 11476:2010 is read in conjunction with ISO 2469.

Papier et carton -- Détermination du degré de blanc CIE C/2 degrés (éclairage intérieur)

L'ISO 11476:2010 spécifie le mode opératoire à utiliser pour déterminer le degré de blanc CIE des papiers et cartons afin d'obtenir des valeurs correspondant à l'aspect visuel des papiers et cartons blancs, avec ou sans agents d'azurage fluorescents, lorsqu'ils sont observés à l'intérieur. Elle est fondée sur des valeurs de facteur de luminance énergétique obtenues pour toute l'étendue du spectre visible, contrairement au mesurage du degré de blancheur ISO qui est limité à la région bleue du spectre visible. L'ISO 11476:2010 spécifie également les modes opératoires permettant de déterminer les valeurs de teinte CIE et la composante de fluorescence du degré de blanc CIE.
En outre, elle spécifie une méthode permettant de régler la teneur en UV afin qu'elle corresponde à celle de l'illuminant CIE C, puisque les valeurs obtenues lorsque des agents d'azurage fluorescents sont présents dépendent de la teneur en UV du rayonnement arrivant sur l'échantillon. L'illuminant CIE C est considéré comme étant représentatif des conditions d'éclairage intérieur puisqu'il contient une quantité adéquate de rayonnement UV. Cette méthode ne convient pas aux papiers de couleur contenant des colorants fluorescents. Elle est spécifique au cas où la fluorescence intervient dans la région bleue de l'étendue du spectre visible.
L'ISO 11476:2010 s'utilise conjointement avec l'ISO 2469.

Papir, karton in lepenka - Določanje beline po CIE, C/2° (pogoji osvetlitve v prostoru)

Ta mednarodni standard opredeljuje postopek, ki se uporablja za določanje beline papirjev, kartonov in lepenk po CIE, z namenom pridobiti vrednosti, ki ustrezajo videzu vrst belega papirja, kartona, lepenka, s fluorescenčnimi belilnimi sredstvi ali brez njih, pri ogledu v prostoru. Temelji na podatkih o faktorju odsevnosti, pridobljenih čez celotno vidno območje spektra (VIS), v nasprotju z merjenjem beline po ISO, ki je omejena na modro področje VIS. Ta mednarodni standard tudi opredeljuje postopke za določanje vrednosti odtenka CIE in fluorescenčne komponente beline po CIE.
Poleg tega opredeljuje metodo za prilagoditev vsebnosti UV, da ustreza vrsti svetlobe CIE C [10][11], ker so rezultati, pridobljeni v prisotnosti fluorescenčnih belilnih sredstev, odvisni od vsebnosti UV sevanja, ki pada na vzorec. Vrsta svetlobe CIE C je vzeta kot reprezentativna za pogoje osvetlitve v prostoru, ker vsebuje primeren delež sevanja UV [12][13]. Ta metoda se ne uporablja za obarvane papirje, ki vsebujejo fluorescenčna barvila. Velja posebej za situacije, kjer se fluorescenca pojavi v modrem področju vidnega območja spektra.
Ta mednarodni standard se bere skupaj z ISO 2469.
OPOMBA 1: Znano je, da je bila enačba beline po CIE razvita v kontekstu standardne vrste svetlobe CIE D65 [6], a podobnost med krivuljami moči relativnega spektra za vrste svetlobe C in D65 v vidnem območju, in bližina njihovih povezanih barvnih temperatur (6 770 K in 6 500 K v tem vrstnem redu) se upoštevajo kot utemeljitev za uporabo analogne enačbe beline z vrsto svetlobe CIE C.
OPOMBA 2: Povezan mednarodni standard ISO 11475 [4] opredeljuje postopek za pridobivanje vrednosti, ki ustrezajo videzu papirjev pod standardno vrsto svetlobe CIE D65.

General Information

Status
Withdrawn
Public Enquiry End Date
29-Mar-2011
Publication Date
13-Apr-2011
Withdrawal Date
06-Apr-2017
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
07-Apr-2017
Due Date
30-Apr-2017
Completion Date
07-Apr-2017

Relations

Buy Standard

Standard
ISO 11476:2011
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 11476:2010 - Paper and board -- Determination of CIE whiteness, C/2 degrees (indoor illumination conditions)
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11476:2010 - Papier et carton -- Détermination du degré de blanc CIE C/2 degrés (éclairage intérieur)
French language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2011
3DSLUNDUWRQLQOHSHQND'RORþDQMHEHOLQHSR&,(&ƒ SRJRMLRVYHWOLWYHY
SURVWRUX
Paper and board -- Determination of CIE whiteness, C/2 degrees (indoor illumination
conditions)
Papier et carton -- Détermination du degré de blanc CIE C/2 degrés (éclairage intérieur)
Ta slovenski standard je istoveten z: ISO 11476:2010
ICS:
85.060 Papir, karton in lepenka Paper and board
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

INTERNATIONAL ISO
STANDARD 11476
Second edition
2010-08-01
Paper and board — Determination of CIE
whiteness, C/2° (indoor illumination
conditions)
Papier et carton — Détermination du degré de blanc CIE C/2°
(éclairage intérieur)
Reference number
©
ISO 2010
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

©  ISO 2010
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2010 – All rights reserved

Contents Page
Foreword .iv
1 Scope.1
2 Normative references.1
3 Terms and definitions .2
4 Principle.3
5 Apparatus and equipment .3
6 Calibration.4
7 Sampling and conditioning .5
8 Preparation of test pieces.5
9 Procedure.5
10 Calculation and expression of results .5
11 Precision.6
12 Test report.7
Annex A (normative) Spectral characteristics of reflectometers for determining tristimulus values .8
Annex B (normative) UV calibration service.11
Bibliography.13

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11476 was prepared by Technical Committee ISO/TC 6, Paper, board and pulps. It is based on the CIE
whiteness formula, published in CIE 15:2004, Colorimetry.
This second edition cancels and replaces the first edition (ISO 11476:2000), which has been technically
revised to include the option to condition samples before measurements.

iv © ISO 2010 – All rights reserved

INTERNATIONAL STANDARD ISO 11476:2010(E)

Paper and board — Determination of CIE whiteness, C/2°
(indoor illumination conditions)
1 Scope
This International Standard specifies the procedure to be used for determining the CIE whiteness of papers
and boards, in order to obtain values which correspond to the visual appearance of white papers and boards,
with or without fluorescent whitening agents, when they are viewed indoors. It is based on radiance factor data
obtained over the full visible spectral range (VIS) in contrast to the measurement of ISO brightness, which is
limited to the blue region of VIS. This International Standard also specifies the procedures for the
determination of CIE tint values and the fluorescent component of CIE whiteness.
In addition, it specifies a method for adjustment of the UV content to correspond to that of CIE illuminant
[10][11]
C , since the results obtained when fluorescent whitening agents are present are dependent upon the
UV content of the radiation falling upon the sample. The CIE illuminant C is taken to be representative of
[12][13]
indoor illumination conditions because it contains a suitable proportion of UV radiation . This method is
not applicable to coloured papers containing fluorescent dyes. It is specific to the situation where the
fluorescence occurs in the blue region of the visible spectral range.
This International Standard is read in conjunction with ISO 2469.
NOTE 1 It is recognized that the CIE whiteness equation was developed in the context of the CIE standard illuminant
[6]
D65 , but the similarity between the relative spectral power curves for the C and D65 illuminants within the visible region
and the closeness of their correlated colour temperatures (6 770 K and 6 500 K respectively) are taken as a justification
for the use of the analogous whiteness equation with the CIE illuminant C.
[4]
NOTE 2 A related International Standard, ISO 11475 specifies the procedure for obtaining values corresponding to
the appearance of papers viewed under the CIE standard illuminant D65.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 186, Paper and board — Sampling to determine average quality
ISO 2469, Paper, board and pulps — Measurement of diffuse radiance factor
ISO 2470-1, Paper, board and pulps — Measurement of diffuse blue reflectance factor — Part 1: Indoor
daylight conditions (ISO brightness)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
reflectance factor
R
ratio of the radiation reflected by a body to that reflected by the perfect reflecting diffuser under the same
conditions
NOTE The reflectance factor is usually expressed as a percentage.
3.2
intrinsic reflectance factor
reflectivity
R

reflectance factor of a layer or pad of the material thick enough to be opaque, i.e. such that increasing the
thickness of the pad by doubling the number of sheets results in no change in the measured reflectance factor
3.3
radiance factor
β
ratio of the radiance of a body to that of the perfect reflecting diffuser under the same conditions of illumination
and viewing
NOTE For fluorescent (luminescent) materials, the total radiance factor, β, is the sum of two portions, the reflected
radiance factor, β , and the luminescent radiance factor, β , so that
S L
ββ=+β
SL
For non-fluorescent materials, the reflected radiance factor, β , is simply the reflectance factor, R.
S
3.4
intrinsic radiance factor
β

radiance factor of a layer or pad of the material thick enough to be opaque, i.e. such that increasing the
thickness of the pad by doubling the number of sheets results in no change in the measured radiance factor
NOTE For fluorescent (luminescent) materials, the intrinsic total radiance factor, β , is the sum of two portions, the

intrinsic reflected radiance factor, β , and the intrinsic luminescent radiance factor, β , so that
∞,S ∞,L
ββ=+β
∞∞,S ∞,L
For non-fluorescent materials, the intrinsic reflected radiance factor, β , is simply the intrinsic reflectance factor, R .
∞,S ∞
3.5
CIE whiteness
W
measure of CIE whiteness derived from the CIE tristimulus values determined under the conditions specified
in this International Standard
NOTE The CIE whiteness is expressed in CIE whiteness units.
3.6
green/red tint
T
w
measure of the deviation from CIE whiteness of the test material towards the green or red region
NOTE 1 The deviation is expressed as CIE tint units.
NOTE 2 A positive value of T indicates a greenish tint and a negative value indicates a reddish tint.
w
2 © ISO 2010 – All rights reserved

3.7
fluorescence component
W
F
measure of the extent to which the CIE whiteness of the material is affected by excitation of the added
fluorescent whitening agent (FWA) under the conditions specified in this International Standard
4 Principle
The diffuse radiance factor of the material is determined under standardized conditions after adjustment of the
instrument so that the relative UV content of the illumination corresponds to that of the CIE illuminant C, and
the CIE whiteness and tint are calculated. The fluorescence component of the CIE whiteness is calculated
from the difference between the diffuse radiance factor value and the value obtained when the fluorescence
emission from the material is eliminated, for instance by the introduction into the light beams of a sharp-cut-off
UV-absorbing filter.
5 Apparatus and equipment
5.1 Reflectometer or spectrophotometer, having the geometric, spectral and photometric characteristics
described in ISO 2469, calibrated in accordance with the provisions of ISO 2470-1, and equipped with a
radiation source having an adequate UV content and a means of adjusting the relative UV content so that the
measured ISO brightness value agrees with the ISO brightness value assigned to a fluorescent reference
standard (5.2.2) and corresponding to the CIE illuminant C (References [7], [8] and [11] in the Bibliography). If
a filter (the UV-adjustment filter) is used to make this adjustment, it shall have a cut-off value of 395 nm so
that it absorbs UV radiation but does not, at the same time, alter the visible spectrum within the sphere.
NOTE In order to achieve concordance between the conditions for measuring both ISO brightness and CIE
whiteness (C/2°), an adjustment based on a fluorescent reference standard (5.2.2) having an assigned ISO brightness
value is preferred.
For the measurement of reflectance factors with the fluorescence effect eliminated, the instrument shall be
equipped with a sharp-cut-off, UV-absorbing filter (the UV cut-off filter) having a transmittance not exceeding
5,0 % at and below a wavelength of 410 nm and not exceeding 50 % at a wavelength of 420 nm. The cut-off
filter shall have characteristics such that a repeatable reflectance factor value is obtained at 420 nm. The
reflectance factor value obtained at 420 nm shall then be considered for computational purposes to be the
value which applies at all lower wavelengths, at which it is not possible to make any measurement.
For the measurement of fluorescent papers, photometric linearity up to a scale reading of at least 200 % is
necessary in the wavelength region corresponding to the fluorescent emission.
5.1.1 In the case of a filter reflectometer, pairs of filters giving the photoelectric detectors of the
reflectometer responses equivalent to the CIE tristimulus values X, Y, Z of
...


INTERNATIONAL ISO
STANDARD 11476
Second edition
2010-08-01
Paper and board — Determination of CIE
whiteness, C/2° (indoor illumination
conditions)
Papier et carton — Détermination du degré de blanc CIE C/2°
(éclairage intérieur)
Reference number
©
ISO 2010
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

©  ISO 2010
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2010 – All rights reserved

Contents Page
Foreword .iv
1 Scope.1
2 Normative references.1
3 Terms and definitions .2
4 Principle.3
5 Apparatus and equipment .3
6 Calibration.4
7 Sampling and conditioning .5
8 Preparation of test pieces.5
9 Procedure.5
10 Calculation and expression of results .5
11 Precision.6
12 Test report.7
Annex A (normative) Spectral characteristics of reflectometers for determining tristimulus values .8
Annex B (normative) UV calibration service.11
Bibliography.13

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11476 was prepared by Technical Committee ISO/TC 6, Paper, board and pulps. It is based on the CIE
whiteness formula, published in CIE 15:2004, Colorimetry.
This second edition cancels and replaces the first edition (ISO 11476:2000), which has been technically
revised to include the option to condition samples before measurements.

iv © ISO 2010 – All rights reserved

INTERNATIONAL STANDARD ISO 11476:2010(E)

Paper and board — Determination of CIE whiteness, C/2°
(indoor illumination conditions)
1 Scope
This International Standard specifies the procedure to be used for determining the CIE whiteness of papers
and boards, in order to obtain values which correspond to the visual appearance of white papers and boards,
with or without fluorescent whitening agents, when they are viewed indoors. It is based on radiance factor data
obtained over the full visible spectral range (VIS) in contrast to the measurement of ISO brightness, which is
limited to the blue region of VIS. This International Standard also specifies the procedures for the
determination of CIE tint values and the fluorescent component of CIE whiteness.
In addition, it specifies a method for adjustment of the UV content to correspond to that of CIE illuminant
[10][11]
C , since the results obtained when fluorescent whitening agents are present are dependent upon the
UV content of the radiation falling upon the sample. The CIE illuminant C is taken to be representative of
[12][13]
indoor illumination conditions because it contains a suitable proportion of UV radiation . This method is
not applicable to coloured papers containing fluorescent dyes. It is specific to the situation where the
fluorescence occurs in the blue region of the visible spectral range.
This International Standard is read in conjunction with ISO 2469.
NOTE 1 It is recognized that the CIE whiteness equation was developed in the context of the CIE standard illuminant
[6]
D65 , but the similarity between the relative spectral power curves for the C and D65 illuminants within the visible region
and the closeness of their correlated colour temperatures (6 770 K and 6 500 K respectively) are taken as a justification
for the use of the analogous whiteness equation with the CIE illuminant C.
[4]
NOTE 2 A related International Standard, ISO 11475 specifies the procedure for obtaining values corresponding to
the appearance of papers viewed under the CIE standard illuminant D65.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 186, Paper and board — Sampling to determine average quality
ISO 2469, Paper, board and pulps — Measurement of diffuse radiance factor
ISO 2470-1, Paper, board and pulps — Measurement of diffuse blue reflectance factor — Part 1: Indoor
daylight conditions (ISO brightness)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
reflectance factor
R
ratio of the radiation reflected by a body to that reflected by the perfect reflecting diffuser under the same
conditions
NOTE The reflectance factor is usually expressed as a percentage.
3.2
intrinsic reflectance factor
reflectivity
R

reflectance factor of a layer or pad of the material thick enough to be opaque, i.e. such that increasing the
thickness of the pad by doubling the number of sheets results in no change in the measured reflectance factor
3.3
radiance factor
β
ratio of the radiance of a body to that of the perfect reflecting diffuser under the same conditions of illumination
and viewing
NOTE For fluorescent (luminescent) materials, the total radiance factor, β, is the sum of two portions, the reflected
radiance factor, β , and the luminescent radiance factor, β , so that
S L
ββ=+β
SL
For non-fluorescent materials, the reflected radiance factor, β , is simply the reflectance factor, R.
S
3.4
intrinsic radiance factor
β

radiance factor of a layer or pad of the material thick enough to be opaque, i.e. such that increasing the
thickness of the pad by doubling the number of sheets results in no change in the measured radiance factor
NOTE For fluorescent (luminescent) materials, the intrinsic total radiance factor, β , is the sum of two portions, the

intrinsic reflected radiance factor, β , and the intrinsic luminescent radiance factor, β , so that
∞,S ∞,L
ββ=+β
∞∞,S ∞,L
For non-fluorescent materials, the intrinsic reflected radiance factor, β , is simply the intrinsic reflectance factor, R .
∞,S ∞
3.5
CIE whiteness
W
measure of CIE whiteness derived from the CIE tristimulus values determined under the conditions specified
in this International Standard
NOTE The CIE whiteness is expressed in CIE whiteness units.
3.6
green/red tint
T
w
measure of the deviation from CIE whiteness of the test material towards the green or red region
NOTE 1 The deviation is expressed as CIE tint units.
NOTE 2 A positive value of T indicates a greenish tint and a negative value indicates a reddish tint.
w
2 © ISO 2010 – All rights reserved

3.7
fluorescence component
W
F
measure of the extent to which the CIE whiteness of the material is affected by excitation of the added
fluorescent whitening agent (FWA) under the conditions specified in this International Standard
4 Principle
The diffuse radiance factor of the material is determined under standardized conditions after adjustment of the
instrument so that the relative UV content of the illumination corresponds to that of the CIE illuminant C, and
the CIE whiteness and tint are calculated. The fluorescence component of the CIE whiteness is calculated
from the difference between the diffuse radiance factor value and the value obtained when the fluorescence
emission from the material is eliminated, for instance by the introduction into the light beams of a sharp-cut-off
UV-absorbing filter.
5 Apparatus and equipment
5.1 Reflectometer or spectrophotometer, having the geometric, spectral and photometric characteristics
described in ISO 2469, calibrated in accordance with the provisions of ISO 2470-1, and equipped with a
radiation source having an adequate UV content and a means of adjusting the relative UV content so that the
measured ISO brightness value agrees with the ISO brightness value assigned to a fluorescent reference
standard (5.2.2) and corresponding to the CIE illuminant C (References [7], [8] and [11] in the Bibliography). If
a filter (the UV-adjustment filter) is used to make this adjustment, it shall have a cut-off value of 395 nm so
that it absorbs UV radiation but does not, at the same time, alter the visible spectrum within the sphere.
NOTE In order to achieve concordance between the conditions for measuring both ISO brightness and CIE
whiteness (C/2°), an adjustment based on a fluorescent reference standard (5.2.2) having an assigned ISO brightness
value is preferred.
For the measurement of reflectance factors with the fluorescence effect eliminated, the instrument shall be
equipped with a sharp-cut-off, UV-absorbing filter (the UV cut-off filter) having a transmittance not exceeding
5,0 % at and below a wavelength of 410 nm and not exceeding 50 % at a wavelength of 420 nm. The cut-off
filter shall have characteristics such that a repeatable reflectance factor value is obtained at 420 nm. The
reflectance factor value obtained at 420 nm shall then be considered for computational purposes to be the
value which applies at all lower wavelengths, at which it is not possible to make any measurement.
For the measurement of fluorescent papers, photometric linearity up to a scale reading of at least 200 % is
necessary in the wavelength region corresponding to the fluorescent emission.
5.1.1 In the case of a filter reflectometer, pairs of filters giving the photoelectric detectors of the
reflectometer responses equivalent to the CIE tristimulus values X, Y, Z of the test piece (Reference [7] in the
Bibliography), evaluated for the CIE illuminant C (Reference [8] in the Bibliography) and CIE 1931 (2°)
observer (Reference [5] in the Bibliography).
5.1.2 In the case of an abridged spectrophotometer, a means of calculating the weighted means in
accordance with the requirements of the CIE illuminant C and CIE 1931 (2°) observer using the weighting
functions given in Annex A.
5.2 Reference standards for calibration of the instrument and working standards
5.2.1 Non-fluorescent reference standard for calibration, fulfilling the requirements for ISO reference
standards of level 3, as specified in ISO 2470-1.
5.2.2 Fluorescent reference standard for use in adjusting the UV content of the radiation incident upon the
sample, having an assigned ISO brightness value, as specified in Annex B, and fulfilling
...


NORME ISO
INTERNATIONALE 11476
Deuxième édition
2010-08-01
Papier et carton — Détermination du
degré de blanc CIE C/2° (éclairage
intérieur)
Paper and board — Determination of CIE whiteness, C/2° (indoor
illumination conditions)
Numéro de référence
©
ISO 2010
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.

DOCUMENT PROTÉGÉ PAR COPYRIGHT

©  ISO 2010
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2010 – Tous droits réservés

Sommaire Page
Avant-propos .iv
1 Domaine d'application .1
2 Références normatives.1
3 Termes et définitions .2
4 Principe.3
5 Appareillage et équipement .3
6 Étalonnage .4
7 Échantillonnage et conditionnement .5
8 Préparation des éprouvettes.5
9 Mode opératoire.5
10 Calcul et expression des résultats .6
11 Fidélité .7
12 Rapport d'essai.7
Annexe A (normative) Caractéristiques spectrales des réflectomètres pour la détermination des
composantes trichromatiques .8
Annexe B (normative) Service d'étalonnage UV.11
Bibliographie.13

Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 11476 a été élaborée par le comité technique ISO/TC 6, Papiers, cartons et pâtes. Elle est fondée sur
la formule du degré de blanc CIE, donnée dans la CIE 15:2004, Colorimétrie.
Cette deuxième édition annule et remplace la première édition (ISO 11476:2000), qui a fait l'objet d'une
révision technique pour inclure l'option de conditionnement des échantillons avant les mesurages.

iv © ISO 2010 – Tous droits réservés

NORME INTERNATIONALE ISO 11476:2010(F)

Papier et carton — Détermination du degré de blanc CIE C/2°
(éclairage intérieur)
1 Domaine d'application
La présente Norme internationale spécifie le mode opératoire à utiliser pour déterminer le degré de blanc CIE
des papiers et cartons afin d'obtenir des valeurs correspondant à l'aspect visuel des papiers et cartons blancs,
avec ou sans agents d'azurage fluorescents, lorsqu'ils sont observés à l'intérieur. Elle est fondée sur des
valeurs de facteur de luminance énergétique obtenues pour toute l'étendue du spectre visible, contrairement
au mesurage du degré de blancheur ISO qui est limité à la région bleue du spectre visible. La présente Norme
internationale spécifie également les modes opératoires permettant de déterminer les valeurs de teinte CIE et
la composante de fluorescence du degré de blanc CIE.
En outre, elle spécifie une méthode permettant de régler la teneur en UV afin qu'elle corresponde à celle de
[10][11]
l'illuminant CIE C , puisque les valeurs obtenues lorsque des agents d'azurage fluorescents sont
présents dépendent de la teneur en UV du rayonnement arrivant sur l'échantillon. L'illuminant CIE C est
considéré comme étant représentatif des conditions d'éclairage intérieur puisqu'il contient une quantité
[12][13]
adéquate de rayonnement UV . Cette méthode ne convient pas aux papiers de couleur contenant des
colorants fluorescents. Elle est spécifique au cas où la fluorescence intervient dans la région bleue de
l'étendue du spectre visible.
La présente Norme internationale s'utilise conjointement avec l'ISO 2469.
NOTE 1 Il est reconnu que l'équation du degré de blanc CIE a été développée dans le contexte de l'illuminant
[6]
normalisé CIE D65 , mais la similarité entre les courbes de puissance spectrale relative pour les illuminants C et D65
dans le visible et la proximité des températures de couleur correspondantes (6 770 K et 6 500 K respectivement) sont
considérées comme justifiant l'utilisation de l'équation analogue de degré de blanc avec l'illuminant CIE C.
[4]
NOTE 2 Une Norme internationale apparentée, l'ISO 11475 , spécifie le mode opératoire pour obtenir les valeurs
correspondant à l'aspect de papiers observés sous l'illuminant normalisé CIE D65.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 186, Papier et carton — Échantillonnage pour déterminer la qualité moyenne
ISO 2469, Papier, carton et pâtes — Mesurage du facteur de luminance énergétique diffuse
ISO 2470-1, Papier, carton et pâtes — Mesurage du facteur de réflectance diffuse dans le bleu — Partie 1:
Conditions d'éclairage intérieur de jour (degré de blancheur ISO)
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s'appliquent.
3.1
facteur de réflectance
R
rapport du rayonnement réfléchi par un corps au rayonnement réfléchi dans les mêmes conditions par le
diffuseur parfait par réflexion
NOTE Le facteur de réflectance est exprimé habituellement en pourcentage.
3.2
facteur de réflectance intrinsèque
R

facteur de réflectance d'une couche ou d'une liasse de matériau suffisamment épaisse pour être opaque,
c'est-à-dire telle que l'augmentation de l'épaisseur de la liasse par doublement du nombre de feuilles la
constituant n'engendre aucune modification du facteur de réflectance mesuré
3.3
facteur de luminance énergétique
β
rapport de la luminance énergétique d'un corps à celle du diffuseur parfait par réflexion, dans les mêmes
conditions d'éclairage et d'observation
NOTE Pour les matériaux fluorescents (luminescents), le facteur de luminance énergétique totale, β, est la somme
de deux grandeurs, le facteur de luminance énergétique par réflexion, β , et le facteur de luminance énergétique par
S
luminescence, β :
L
β = β + β
S L
Pour les matériaux non fluorescents, le facteur de luminance énergétique par réflexion, β , est simplement le facteur de
S
réflectance, R.
3.4
facteur de luminance énergétique intrinsèque
β

facteur de luminance énergétique d'une couche ou d'une liasse de matériau suffisamment épaisse pour être
opaque, c'est-à-dire telle que l'augmentation de l'épaisseur de la liasse par doublement du nombre de feuilles
la constituant n'engendre aucune modification du facteur de luminance énergétique mesuré
NOTE Pour les matériaux fluorescents (luminescents), le facteur de luminance énergétique intrinsèque totale, β , est

la somme de deux grandeurs, le facteur de luminance énergétique intrinsèque par réflexion, β , et le facteur de
∞,S
luminance énergétique intrinsèque par luminescence, β :
∞,L
β = b + b
∞ ∞,S ∞,L
Pour les matériaux non fluorescents, le facteur de luminance énergétique intrinsèque par réflexion, β , est simplement le
∞,S
facteur de réflectance intrinsèque, R .

3.5
degré de blanc CIE
W
mesure du degré de blanc CIE, dérivée des composantes trichromatiques CIE déterminées dans les
conditions spécifiées dans la présente Norme internationale
NOTE Le degré de blanc CIE est exprimé en unités de degré de blanc CIE.
2 © ISO 2010 – Tous droits réservés

3.6
teinte vert/rouge
T
w
mesure de la déviation du degré de blanc CIE du matériau soumis à essai vers la région du vert ou du rouge
NOTE 1 La déviation est exprimée en unités de teinte CIE.
NOTE 2 Une valeur positive de T indique une teinte tirant sur le vert, et une valeur négative une teinte tirant sur le
w
rouge.
3.7
composante de fluorescence
W
F
mesure de l'importance de la modification du degré de blanc CIE du matériau par l'excitation des agents
d'azurage fluorescents ajoutés, dans les conditions spécifiées dans la présente Norme internationale
4 Principe
Le facteur de luminance énergétique diffuse du matériau est déterminé dans des conditions normalisées
après réglage de l'appareil, de sorte que la teneur relative en UV de l'éclairage corresponde à celle de
l'illuminant CIE C, et le degré de blanc CIE et la teinte sont calculés. La composante de fluorescence du
degré de blanc CIE est calculée comme étant la différence entre la valeur du facteur de luminance
énergétique diffuse et la valeur obtenue après élimination de l'émission fluorescente du matériau, par
exemple en insérant dans les faisceaux lumineux un filtre absorbant les UV, à coupure nette.
5 Appareillage et équipement
5.1 Réflectomètre ou spectrophotomètre, ayant les caractéristiques géométriques, spectrales et
photométriques décrites dans l'ISO 2469, étalonné conformément aux dispositions de l'ISO 2470-1, et équipé
d'une source de rayonnement à teneur adéquate en UV et d'un moyen de réglage de la teneur relative en UV,
de sorte que la valeur mesurée du degré de blancheur ISO concorde avec la valeur de degré de blancheur
ISO assignée à un étalon de référence fluorescent (5.2.2), et correspondant à l'illuminant CIE C
(Références [7], [8] et [11]). Si un filtre (le filtre de réglage de teneur en UV) est utilisé pour faire ce réglage, il
doit avoir une coupure nette à 395 nm afin d'absorber tout rayonnement UV sans altérer le spectre visible à
l'intérieur de la sphère.
NOTE Afin d'obtenir une concordance entre les conditions pour mesurer à la fois le degré de blancheur ISO et le
degré de blanc CIE (C/2°), un ajustement fondé sur un étalon de référence fluorescent (5.2.2) qui a une valeur assignée
de degré de blancheur ISO est préféré.
Pour le mesurage des facteurs de réflectance après élimination de la fluorescence, l'appareil doit être équipé
d'un filtre absorbant les UV, de coupure nette, dont le facteur de transmission n'excède pas 5,0 % à une
longueur d'onde inférieure ou égale à 410 nm, et pas plus de 50 % à une longueur d'onde de 420 nm. Le filtre
à coupure doit avoir des caractéristiques telles qu'une valeur reproductible du facte
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.