SIST EN 300 417-2-2 V1.1.4:2003 is a European standard specifying the Implementation Conformance Statement (ICS) proforma for equipment supporting the physical section layer functions of Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) in telecommunications transmission systems. Published by the Slovenski inštitut za standardizacijo (SIST) and aligning with ETSI standards, this document provides a formalized structure to declare and assess the conformity of SDH and PDH equipment to Part 2-1 (EN 300 417-2-1) requirements.

This standard helps suppliers and users verify compliance, streamline interoperability, and maintain high-quality network performance in digital transport networks.

Key Topics

  • ICS Proforma Structure: Organizes how manufacturers or implementers declare conformity with SDH and PDH physical section requirements.
  • Layer Coverage: Addresses physical section functions for multiple SDH rates (STM-1, STM-4, STM-16) and PDH interfaces (E0, E12, E22, E31, E4) including both optical and electrical sections.
  • Conformance Documentation: Enables clear reporting on whether an implementation meets each technical requirement outlined in the referenced standards.
  • Component Identification: Standardizes identification fields such as supplier, client, and system under test for traceability and auditability.
  • Testing & Performance Monitoring: Supports systematic testing, fault detection, defect management, and performance evaluation for transmission equipment.

Applications

SIST EN 300 417-2-2 V1.1.4:2003 is valuable throughout the telecommunications and networking industry:

  • Equipment Manufacturers: Use the ICS proforma to document SDH and PDH equipment compliance. This is key in responding to procurement requests where conformity to standards is mandatory.
  • Network Operators and Service Providers: Assess compliance of new system components, reducing integration risks and ensuring multi-vendor interoperability for digital transmission networks.
  • Testing Laboratories: Apply the standard as a framework for conformance audits, acceptance testing, and quality assurance for SDH/PDH section layer functionality.
  • Procurement Professionals: Reference the standardized proforma to demand consistent declarations of implemented features and compatibility during supplier evaluation and tendering processes.
  • System Integrators: Verify that deployed hardware meets performance and interface requirements critical for large-scale, reliable transport networks.

Employing this ICS proforma results in clear communication between vendors and customers, facilitating smoother implementation, service scalability, and reliable transport network operations.

Related Standards

  • EN 300 417-2-1: Core specification for SDH and PDH physical section layer functions-this ICS proforma directly supports conformance to these requirements.
  • SIST EN 300 417-1-1/1-2: Addresses generic processes, performance, and general guidance on conformance statement proformas.
  • SIST EN 300 417-3-1: Covers regenerator and multiplex section layer functions for STM-N networks.
  • ISO/IEC 9646: Offers general methodologies for Implementation Conformance Statements across ICT standards.
  • Other ETSI TM Series Standards: Extend similar conformance and testing frameworks across related transmission and multiplexing technologies.

Adopting SIST EN 300 417-2-2 V1.1.4:2003 ensures that SDH and PDH equipment in modern transmission systems meets established European requirements for functionality, reliability, and interoperability. This is vital for supporting robust, scalable, and interoperable digital communications infrastructure.

Buy Documents

Standard

SIST EN 300 417-2-2 V1.1.4:2003

English language (123 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 300 417-2-2 V1.1.4:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 2-2: Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical section layer functions; Implementation Conformance Statement (ICS) proforma specification". This standard covers: ICS proforma for ETS 300 417-2-1.

ICS proforma for ETS 300 417-2-1.

SIST EN 300 417-2-2 V1.1.4:2003 is classified under the following ICS (International Classification for Standards) categories: 33.040.20 - Transmission systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 300 417-2-2 V1.1.4:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.XQNFLRQDOQRVWTransmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 2-2: Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical section layer functions; Implementation Conformance Statement (ICS) proforma specification33.040.20Prenosni sistemTransmission systemsICS:Ta slovenski standard je istoveten z:EN 300 417-2-2 Version 1.1.4SIST EN 300 417-2-2 V1.1.4:2003en01-december-2003SIST EN 300 417-2-2 V1.1.4:2003SLOVENSKI
STANDARD
EN 300 417-2-2 V1.1.4 (1999-05)European Standard (Telecommunications series)Transmission and Multiplexing (TM);Generic requirements of transport functionality of equipment;Part 2-2: Synchronous Digital Hierarchy (SDH) andPlesiochronous Digital Hierarchy (PDH)physical section layer functions;Implementation Conformance Statement (ICS)proforma specificationSIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)2ReferenceREN/TM-01015-2-2b (3v0iiieo.PDF)KeywordsICS, PDH, SDH, STM, transmission, testingETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgIf you find errors in the present document, send yourcomment to: editor@etsi.frCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1999.All rights reserved.SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)3ContentsIntellectual Property Rights.9Foreword.9Introduction.101Scope.112References.113Definitions and abbreviations.123.1Definitions.123.2Abbreviations.124Conformance to this ICS proforma specification.14Annex A (normative):ICS proforma for EN 300 417-2-1.15A.1Guidance for completing the ICS proforma.15A.1.1Purposes and structure.15A.1.2Abbreviations and conventions.15A.1.3Instructions for completing the ICS proforma.17Annex B (normative):ICS proforma for STM-1 optical section layer.18B.1Identification of the implementation.18B.1.1Date of the statement.18B.1.2IUT identification.18B.1.3SUT identification.18B.1.4Product supplier.19B.1.5Client.19B.1.6ICS contact person.20B.2Identification of the EN.20B.3Global statement of conformance of OS1 layer.20B.4OS1 layer description.21B.5OS1 layer transmission tables.22B.5.1OS1 source operating wavelength range, OS1_TT_So.22B.5.2OS1 source spectral characteristics, OS1_TT_So.23B.5.3OS1 source optical characteristics, OS1_TT_So.24B.5.4OS1 receiver characteristics, OS1_TT_Sk.25B.5.5OS1 regeneration characteristics, OS1/RS1_A_So, OS1/RS1_A_Sk.26B.6Defect, fault and performance monitoring.27B.6.1Port status management.27B.6.2Defect detection and clearance criteria.27B.6.3Consequent action activation and clearance criteria.28B.6.4Defect correlation.29B.6.5Performance monitoring.29Annex C (normative):ICS proforma for STM-4 optical section layer.30C.1Identification of the implementation.30C.1.1Date of the statement.30C.1.2IUT identification.30C.1.3SUT identification.30C.1.4Product supplier.31C.1.5Client.31C.1.6ICS contact person.32SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)4C.2Identification of the EN.32C.3Global statement of conformance of OS4 layer.32C.4OS4 layer description.33C.5OS4 layer transmission tables.34C.5.1OS4 source operating wavelength range, OS4_TT_So.34C.5.2OS4 source spectral characteristics, OS4_TT_So.35C.5.3OS4 source optical characteristics, OS4_TT_So.36C.5.4OS4 receiver characteristics, OS4_TT_Sk.37C.5.5OS4 regeneration characteristics, OS4/RS4_A_So, OS4/RS4_A_Sk.38C.6OS4 layer defect, fault and performance monitoring tables.39C.6.1Port status management.39C.6.2Defect detection and clearance criteria.39C.6.3Consequent action activation and clearance criteria.40C.6.4Defect correlation.41C.6.5Performance monitoring.41Annex D (normative):ICS proforma for STM-16 optical section layer.42D.1Identification of the implementation.42D.1.1Date of the statement.42D.1.2IUT identification.42D.1.3SUT identification.42D.1.4Product supplier.43D.1.5Client.43D.1.6ICS contact person.44D.2Identification of the EN.44D.3Global statement of conformance of OS16 layer.44D.4OS16 layer description.45D.5OS16 layer transmission tables.46D.5.1OS16 source operating wavelength range, OS16_TT_So.46D.5.2OS16 source spectral characteristics, OS16_TT_So.46D.5.3OS16 source optical characteristics, OS16_TT_So.47D.5.4OS16 receiver characteristics, OS16_TT_Sk.48D.5.5OS16 regeneration characteristics, OS16/RS16_A_So, OS16/RS16_A_Sk.49D.6OS16 layer defect, fault and performance monitoring tables.50D.6.1Port status management.50D.6.2Defect detection and clearance criteria.50D.6.3Consequent action activation and clearance criteria.51D.6.4Defect correlation.52D.6.5Performance monitoring.52Annex E (normative):ICS proforma for STM-1 electrical section layer.53E.1Identification of the implementation.53E.1.1Date of the statement.53E.1.2IUT identification.53E.1.3SUT identification.53E.1.4Product supplier.54E.1.5Client.54E.1.6ICS contact person.55SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)5E.2Identification of the EN.55E.3Global statement of conformance of ES1 layer.55E.4ES1 layer description.56E.5ES1 layer transmission tables.56E.5.1ES1 layer data stream.56E.5.2ES1 layer connection function, ES1_C.56E.5.3ES1 layer trail termination functions, ES1_TT_So and ES1_TT_Sk.57E.5.4ES1 to RS1 adaptation functions, ES1/RS1_A_So and ES1/RS1_A_Sk.58E.6ES1 layer defect, fault and performance monitoring tables.59E.6.1Port status management.59E.6.2Defect detection and clearance criteria.60E.6.3Consequent action activation and clearance criteria.60E.6.4Defect correlation.61E.6.5Performance monitoring.61Annex F (normative):ICS proforma for E4 electrical section layer.62F.1Identification of the implementation.62F.1.1Date of the statement.62F.1.2IUT identification.62F.1.3SUT identification.62F.1.4Product supplier.63F.1.5Client.63F.1.6ICS contact person.64F.2Identification of the EN.64F.3Global statement of conformance of E4 layer.64F.4E4 layer description.65F.5E4 layer transmission tables.65F.5.1E4 layer data stream.65F.5.2E4 layer connection function, E4_C.65F.5.3E4 layer trail termination functions, E4_TT_So and E4_TT_Sk.66F.5.4E4 to P4x adaptation functions, E4/P4x_A_So and E4/P4x_A_Sk.67F.5.5E4to P4e adaptation functions, E4/P4e_A_So and E4/P4e_A_Sk.68F.5.6E4 to P4s adaptation functions, E4/P4s_A_So and E4/P4s_A_Sk.69F.6E4 layer defect, fault and performance monitoring tables.70F.6.1Port status management.70F.6.2Defect detection and clearance criteria.71F.6.3Consequent action activation and clearance criteria.71F.6.4Defect correlation.72Annex G (normative):ICS proforma for E31 electrical section layer.73G.1Identification of the implementation.73G.1.1Date of the statement.73G.1.2IUT identification.73G.1.3SUT identification.73G.1.4Product supplier.74G.1.5Client.74G.1.6ICS contact person.75SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)6G.2Identification of the EN.75G.3Global statement of conformance of E31 layer.75G.4E31 layer description.76G.5E31 layer transmission tables.76G.5.1E31 layer data stream.76G.5.2E31 layer connection function, E31_C.76G.5.3E31 layer trail termination functions, E31_TT_So and E31_TT_Sk.77G.5.4E31 to P31x adaptation functions, E31/P31x_A_So and E31/P31x_A_Sk.78G.5.5E31to P31e adaptation functions, E31/P31e_A_So and E31/P31e_A_Sk.79G.5.6E31 to P31s adaptation functions, E31/P31s_A_So and E31/P31s_A_Sk.80G.6E31 layer defect, fault and performance monitoring tables.81G.6.1Port status management.81G.6.2Defect detection and clearance criteria.82G.6.3Consequent action activation and clearance criteria.82G.6.4Defect correlation.83Annex H (normative):ICS proforma for E22 electrical section layer.84H.1Identification of the implementation.84H.1.1Date of the statement.84H.1.2IUT identification.84H.1.3SUT identification.84H.1.4Product supplier.85H.1.5Client.85H.1.6ICS contact person.86H.2Identification of the EN.86H.3Global statement of conformance of E22 layer.86H.4E22 layer description.87H.5E22 layer transmission tables.87H.5.1E22 layer data stream.87H.5.2E22 layer connection function, E22_C.87H.5.3E22 layer trail termination functions, E22_TT_So and E22_TT_Sk.88H.5.4E22 to P22x adaptation functions, E22/P22x_A_So and E22/P22x_A_Sk.89H.5.5E22to P22e adaptation functions, E22/P22e_A_So and E22/P22e_A_Sk.90H.6E22 layer defect, fault and performance monitoring tables.91H.6.1Port status management.91H.6.2Defect detection and clearance criteria.91H.6.3Consequent action activation and clearance criteria.92H.6.4Defect correlation.93Annex J (normative):ICS proforma for E12 electrical section layer.94J.1Identification of the implementation.94J.1.1Date of the statement.94J.1.2IUT identification.94J.1.3SUT identification.94J.1.4Product supplier.95J.1.5Client.95J.1.6ICS contact person.96SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)7J.2Identification of the EN.96J.3Global statement of conformance of E12 layer.96J.4E12 layer description.97J.5E12 layer transmission tables.97J.5.1E12 layer data stream.97J.5.2E12 electrical section connection function, E12_C.97J.5.3E12layer trail termination functions, E12_TT_So and E12_TT_Sk.98J.5.4E12 to P12x adaptation functions, E12/P12x_A_So and E12/P12x_A_Sk.100J.5.5E12 to P12s adaptation functions, E12/P12s_A_So and E12/P12s_A_Sk.101J.6E12 layer defect, fault and performance monitoring tables.104J.6.1Port status management.104J.6.2Defect detection and clearance criteria.104J.6.3Consequent action activation and clearance criteria.105J.6.4Defect correlation.106Annex K (normative):ICS proforma for T12 electrical section layer.107K.1Identification of the implementation.107K.1.1Date of the statement.107K.1.2IUT identification.107K.1.3SUT identification.107K.1.4Product supplier.108K.1.5Client.108K.1.6ICS contact person.109K.2Identification of the EN.109K.3Global statement of conformance of T12 layer.109K.4T12 layer description.110K.5T12 layer transmission tables.110K.5.1T12 layer data stream.110K.5.2T12layer connection function, T12_C.110K.5.3T12layer trail termination functions, T12_TT_So and T12_TT_Sk.110K.5.4T12 to SD adaptation functions, T12/SD_A_So and T12/SD_A_Sk.111K.6T12 layer defect, fault and performance monitoring tables.111K.6.1Port status management.112K.6.2Defect detection and clearance criteria.112K.6.3Consequent action activation and clearance criteria.112K.6.4Defect correlation.113Annex L (normative):ICS proforma for E0 electrical section layer.114L.1Identification of the implementation.114L.1.1Date of the statement.114L.1.2IUT identification.114L.1.3SUT identification.114L.1.4Product supplier.115L.1.5Client.115L.1.6ICS contact person.116L.2Identification of the EN.116L.3Global statement of conformance of E0 layer.116L.4E0 layer description.117L.5E0 layer transmission tables.117L.5.1E0 layer data stream.117L.5.2E0 layer connection function, E0_C.117SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)8L.5.3E0 layer trail termination functions, E0_TT_So and E0_TT_Sk.118L.5.4E0 to P0s adaptation functions, E0/P0s_A_So and E0/P0s_A_Sk.119L.6E0 layer defect, fault and performance monitoring tables.120L.6.1Port status management.120L.6.2Defect detection and clearance criteria.120L.6.3Consequent action activation and clearance criteria.120L.6.4Defect correlation.121Bibliography.122History.123SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)9Intellectual Property RightsIPRs essential or potentially essential to the present document may have been declared to ETSI. The informationpertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be foundin SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respectof ETSI standards", which is available free of charge from the ETSI Secretariat. Latest updates are available on theETSI Web server (http://www.etsi.org/ipr).Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guaranteecan be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)which are, or may be, or may become, essential to the present document.ForewordThis European Standard (Telecommunications series) has been produced by ETSI Technical Committee Transmissionand Multiplexing (TM).The present document is one of a family of documents that has been produced in order to provide inter-vendor andinter-operator compatibility of Synchronous Digital Hierarchy (SDH) equipment.The present document is part 2-2 of a multi-part EN covering the generic requirements of transport functionality ofequipment, as identified below:Part 1-1:"Generic processes and performance".Part 1-2:"General information about Implementation Conformance Statement (ICS) proforma".Part 2-1:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical sectionlayer functions".Part 2-2:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physicalsection layer functions; Implementation Conformance Statement (ICS) proforma specification".Part 3-1:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions".Part 3-2:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions;Implementaion Conformance Statement (ICS) proforma specification".Part 4-1:"Synchronous Digital Hierarchy (SDH) path layer functions".Part 4-2:"Synchronous Digital Hierarchy (SDH) path layer functions; Implementation Conformance Statement(ICS) proforma specification".Part 5-1:"Plesiochronous Digital Hierarchy (PDH) path layer functions".Part 5-2:"Plesiochronous Digital Hierarchy (PDH) path layer functions; Implementation Conformance Statement(ICS) proforma specification".Part 6-1:"Synchronization layer functions".Part 6-2:"Synchronization layer functions; Implementation Conformance Statement (ICS) proforma specification".Part 7-1:"Auxiliary layer functions".Part 7-2:"Auxiliary layer functions; Implementation Conformance Statement (ICS) proforma specification".Parts 2 to 7 specify the layers and their atomic functions.NOTE 1:The present document does not currently address configuration management.NOTE 2:The SDH radio equipment functional blocks are addressed by ETSI WG TM4.Various of the above parts have previously been published as parts of ETS 300 417.SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)10They have been converted into parts of EN 300 417 without technical changes, but some editorial changes have beennecessary (e.g. references). In particular:-Parts 2-1, 2-2 and 3-2 have been modified to take account of editorial errors present in edition 1.-Part 1-1 has had its title change of to align with other parts published at a later date.Also note that in the meantime parts 8-1 and 8-2 together will all parts x-3 (Abstract Test Suites) have been stopped.This version of the present document has been published because the previous two versions had incorrect dates in thetransposition table.National transposition datesDate of latest announcement of this EN (doa):31 August 1999Date of latest publication of new National Standardor endorsement of this EN (dop/e):29 February 2000Date of withdrawal of any conflicting National Standard (dow):29 February 2000IntroductionTo evaluate conformance of a particular implementation, it is necessary to have a statement of which capabilities andoptions have been implemented for a telecommunication specification. Such a statement is called an ImplementationConformance Statement (ICS).A client of a test laboratory who requests a conformance / approval test shall provide to the test laboratory a completedICS proforma for each layer to be tested and a detailed system description of the implementation.The ICS proforma is not another complete description of the related specification, but rather a compact form of its staticconformance requirements, to be used by the test laboratory to identify which test shall be performed on a givenimplementation. Not every feature of a profile specification is contained in the related ICS proforma. For particularcases requiring specific information the ICS can refer to the appropriate clause of the related specification by means ofreferences, notes and or comments.The ICS proforma captures the implementation flexibility allowed by the related specification and details which optionare left to the implementor, which are conditionally dependent on other option taken by the implementor.SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)111ScopeThe present document provides the Implementation Conformance Statement (ICS) proforma specification for theSynchronous Digital Hierarchy (SDH) equipment physical section layer functions defined in EN 300 417-2-1 [7] incompliance with the relevant requirements, and in accordance with the relevant guidance given in ISO/IEC 9646-7 [10]and ETS 300 406 [5].2ReferencesThe following documents contain provisions which, through reference in this text, constitute provisions of the presentdocument.· References are either specific (identified by date of publication, edition number, version number, etc.) ornon-specific.· For a specific reference, subsequent revisions do not apply.· For a non-specific reference, the latest version applies.· A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the samenumber.[1]ETS 300 166 (1993): "Transmission and Multiplexing (TM); Physical and electrical characteristicsof hierarchical digital interfaces for equipment using the 2 048 kbit/s - based plesiochronous orsynchronous digital hierarchies".[2]ETS 300 167 (1993): "Transmission and Multiplexing (TM); Functional characteristics of2 048 kbit/s interfaces".[3]ETS 300 232: "Transmission and Multiplexing (TM); Optical interfaces for equipments andsystems relating to the Synchronous Digital Hierarchy [ITU-T Recommendation G.957 (1993)modified]".[4]ETS 300 337 (1993): "Transmission and Multiplexing (TM); Generic frame structures for thetransport of various signals (including Asynchronous Transfer Mode (ATM) cells and SynchronousDigital Hierarch
...