SIST ISO 16000-4:2013
Indoor air - Part 4: Determination of formaldehyde - Diffusive sampling method
Indoor air - Part 4: Determination of formaldehyde - Diffusive sampling method
ISO 16000-4:2011 specifies a determination of formaldehyde in indoor air using a diffusive sampler with solvent desorption and high performance liquid chromatography (HPLC).
The test method is applicable to the measurement of formaldehyde in indoor air over the range from 0,001 mg/m3 to 1,0 mg/m3 for a sampling period of between 24 h and 72 h. For sampling periods of 24 h, the applicable concentration range is 0,003 mg/m3 to 1 mg/m3, and for 72 h it is 0,001 mg/m3 to 0,33 mg/m3.
The method is suitable for measurements in atmospheres with conventional indoor air relative humidity and for monitoring at air velocities as low as 0,02 m/s. The chromatographic step in the method is designed to eliminate potential interferences, including those due to the presence of other carbonyl compounds. The sampling method gives a time-weighted average result.
Air intérieur - Partie 4: Dosage du formaldéhyde - Méthode par échantillonnage diffusif
L'ISO 16000-4:2011 spécifie un dosage du formaldéhyde dans l'air intérieur au moyen d'un échantillonneur par diffusion avec désorption de solvant et chromatographie en phase liquide à haute performance (CLHP).
La méthode d'essai s'applique au mesurage du formaldéhyde dans l'air intérieur dans une gamme comprise entre 0,001 mg/m3 et 1,0 mg/m3 pour une période d'échantillonnage comprise entre 24 h et 72 h. Pour des périodes d'échantillonnage de 24 h, la gamme de concentration applicable est comprise entre 0,003 mg/m3 et 1 mg/m3, et pour des périodes de 72 h, elle est comprise entre 0,001 mg/m3 et 0,33 mg/m3.
La méthode convient à des mesurages réalisés dans des atmosphères ayant une humidité relative dans l'air intérieur normale et pour la surveillance à des vitesses d'air de l'ordre de 0,02 m/s. L'étape de chromatographie prévue dans la méthode est destinée à permettre l'élimination des interférences potentielles, notamment celles dues à la présence d'autres composés carbonylés. La méthode d'échantillonnage fournit un résultat moyen pondéré dans le temps.
Notranji zrak - 4. del: Določevanje formaldehida - Difuzijska metoda vzorčenja
Ta del standarda ISO 16000 opredeljuje določevanje formaldehida v notranjem zraku z uporabo difuzijskega vzorčevalnika z desorpcijo topila in tekočinsko kromatografijo visoke ločljivosti (HPLC). Preskusna metoda se uporablja za merjenje formaldehida1) v notranjem zraku v območju od 0,001 mg/m3 do 1,0 mg/m3 za obdobje vzorčenja med 24 h in 72 h. Za obdobja vzorčenja s trajanjem 24 h je veljavno območje koncentracije 0,003 mg/m3 do 1 mg/m3, za obdobja s trajanjem 72 h pa 0,001 mg/m3 do 0,33 mg/m3. OPOMBA Potrjeni vzorčevalniki glede na občutljivost in natančnost merjenja se lahko uporabljajo za kratkoročno vzorčenje (manj kot 24 h). Metoda je primerna za merjenja v ozračjih z običajno relativno vlažnostjo notranjega zraka in za spremljanje pri hitrostih zraka, ki lahko znašajo tudi le 0,02 m/s. Kromatografski korak v metodi je namenjen odpravi morebitnih motenj, vključno z motnjami zaradi prisotnosti drugih karbonilnih spojin. Metoda vzorčenja podaja časovno tehtani povprečni rezultat. OPOMBA Na trgu je na voljo več difuzijskih vzorčevalnikov z različnimi zasnovami in oblikami. Vsi vzorčevalniki temeljijo na reakciji 2,4-dinitrofenilhidrazina s formaldehidom. Vzorčevalniki v tem delu standarda ISO 16000 niso posebej opisani, da bralci ne bi dobili vtisa, da standard ISO daje prednost enemu modelu.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2013
1DGRPHãþD
SIST ISO 16000-4:2004
1RWUDQML]UDNGHO'RORþHYDQMHIRUPDOGHKLGD'LIX]LMVNDPHWRGDY]RUþHQMD
Indoor air - Part 4: Determination of formaldehyde - Diffusive sampling method
Air intérieur - Partie 4: Dosage du formaldéhyde - Méthode par échantillonnage diffusif
Ta slovenski standard je istoveten z: ISO 16000-4:2011
ICS:
13.040.20 Kakovost okoljskega zraka Ambient atmospheres
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
INTERNATIONAL ISO
STANDARD 16000-4
Second edition
2011-12-01
Indoor air —
Part 4:
Determination of formaldehyde —
Diffusive sampling method
Air intérieur —
Partie 4: Dosage du formaldéhyde — Méthode par échantillonnage
diffusif
Reference number
©
ISO 2011
© ISO 2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2011 – All rights reserved
Contents Page
Foreword . iv
Introduction . vi
1 Scope . 1
2 Normative references . 1
3 Principle . 2
4 Reagents . 2
5 Apparatus . 3
6 Sampling . 4
7 Procedure . 4
7.1 Desorption and sample preparation . 4
7.2 Calibration . 4
7.3 HPLC analysis . 5
7.4 Determination of sample concentration . 6
7.5 Storage . 6
7.6 Determination of desorption efficiency . 6
8 Calculation . 6
8.1 Mass of DNPH-formaldehyde on the filter . 6
8.2 Concentration of formaldehyde in air . 7
9 Precision and uncertainty of the method . 7
10 Quality assurance/quality control . 8
11 Test report . 8
Annex A (informative) Typical designs of diffusive samplers . 9
Bibliography . 11
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 16000-4 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 6, Indoor air.
This second edition cancels and replaces the first edition (ISO 16000-4:2004), which has been technically
revised, especially 7.2.
ISO 16000 consists of the following parts, under the general title Indoor air:
Part 1: General aspects of sampling strategy
Part 2: Sampling strategy for formaldehyde
Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber
air — Active sampling method
Part 4: Determination of formaldehyde — Diffusive sampling method
Part 5: Sampling strategy for volatile organic compounds (VOCs)
Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on ®
Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations
Part 8: Determination of local mean ages of air in buildings for characterizing ventilation conditions
Part 9: Determination of the emission of volatile organic compounds from building products and
furnishing — Emission test chamber method
Part 10: Determination of the emission of volatile organic compounds from building products and
furnishing — Emission test cell method
Part 11: Determination of the emission of volatile organic compounds from building products and
furnishing — Sampling, storage of samples and preparation of test specimens
Part 12: Sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins
(PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs)
iv © ISO 2011 – All rights reserved
Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and
polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Collection on sorbent-backed filters
Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and
polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Extraction, clean-up and analysis by
high-resolution gas chromatography and mass spectrometry
Part 15: Sampling strategy for nitrogen dioxide (NO )
Part 16: Detection and enumeration of moulds — Sampling by filtration
Part 17: Detection and enumeration of moulds — Culture-based method
Part 18: Detection and enumeration of moulds — Sampling by impaction
Part 19: Sampling strategy for moulds
Part 23: Performance test for evaluating the reduction of formaldehyde concentrations by sorptive
building materials
Part 24: Performance test for evaluating the reduction of volatile organic compound (except
formaldehyde) concentrations by sorptive building materials
Part 25: Determination of the emission of semi-volatile organic compounds by building products — Micro-
chamber method
Part 26: Sampling strategy for carbon dioxide (CO )
Part 28: Determination of odour emissions from building products using test chambers
The following parts are under preparation:
Part 21: Detection and enumeration of moulds — Sampling from materials
Part 27: Determination of settled fibrous dust on surfaces by SEM (scanning electron microscopy) (direct
method)
Part 29: Test methods for VOC detectors
Part 30: Sensory testing of indoor air
Part 31: Measurement of flame retardants and plasticizers based on organophosphorus compounds —
Phosphoric acid ester
Part 32: Investigation of constructions on pollutants and other injurious factors — Inspections
Introduction
Formaldehyde has a high potential toxicity, and therefore, its determination is of interest as an indoor air
pollutant. Formaldehyde is an irritant that may cause allergic reactions and other health issues.
Formaldehyde is the simplest carbonyl compound, with one carbon, one oxygen and two hydrogen atoms. In
its monomolecular state, it is a colourless, pungent, reactive gas. It has been used in the production of urea-
formaldehyde resins, adhesives and insulating foams. Emissions from particle (chip) board and wall insulation
are the major sources of formaldehyde in indoor air.
This part of ISO 16000 is intended to be used for characterizing indoor air following the sampling strategy for
formaldehyde specified in ISO 16000-2. ISO 16000-1 gives general requirements for the measurement of
indoor air pollutants and the important conditions to be observed before or during the sampling of individual
pollutants or groups of pollutants.
An active formaldehyde measurement procedure (reference method) is specified in ISO 16000-3.
Aspects of the determination (sampling and analysis) and the sampling strategy of specific pollutants or
groups of pollutants are specified in the other parts of ISO 16000.
[6][7] [1]–[5]
ISO 16017 and ISO 12219 also focus on volatile organic compound (VOC) measurements.
vi © ISO 2011 – All rights reserved
INTERNATIONAL STANDARD ISO 16000-4:2011(E)
Indoor air —
Part 4:
Determination of formaldehyde — Diffusive sampling method
WARNING — Persons using this part of ISO 16000 should be familiar with normal laboratory practice.
This part of ISO 16000 does not purport to address all of the safety problems, if any, associated with
its use. It is the responsibility of the user to establish appropriate safety and health practices and to
ensure compliance with any national regulatory conditions.
1 Scope
This part of ISO 16000 specifies a determination of formaldehyde in indoor air using a diffusive sampler with
solvent desorption and high performance liquid chromatography (HPLC).
1 )
The test method is applicable to the measurement of formaldehyde in indoor air over the range from
3 3
0,001 mg/m to 1,0 mg/m for a sampling period of between 24 h and 72 h. For sampling periods of 24 h, the
3 3 3 3
applicable concentration range is 0,003 mg/m to 1 mg/m , and for 72 h it is 0,001 mg/m to 0,33 mg/m .
NOTE Confirmed samplers with respect to measurement sensitivity and precision can apply to short-term sampling
(less than 24 h).
The method is suitable for measurements in atmospheres with conventional indoor air relative humidity and
for monitoring at air velocities as low as 0,02 m/s. The chromatographic step in the method is designed to
eliminate potential interferences, including those due to the presence of other carbonyl compounds. The
sampling method gives a time-weighted average result.
NOTE There are several diffusive samplers with various designs and shapes commercially available. They are all
based on the reaction of 2,4-dinitrophenylhydrazine with formaldehyde. They are not specifically described in this part of
ISO 16000 to avoid any impression that ISO favours one model over another.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 16000-2, Indoor air — Part 2: Sampling strategy for formaldehyde
ISO 16000-3:2011, Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in
indoor air and test chamber air — Active sampling method
ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories
EN 13528-2, Ambient air quality — Diffusive samplers for the determination of concentrations of gases and
vapours — Requirements and test methods — Part 2: Specific requirements and test methods
1) Instead of systematic IUPAC nomenclature, traditional names are used in this part of ISO 16000, e.g. “formaldehyde”
is used instead of “methanal”.
© ISO
...
INTERNATIONAL ISO
STANDARD 16000-4
Second edition
2011-12-01
Indoor air —
Part 4:
Determination of formaldehyde —
Diffusive sampling method
Air intérieur —
Partie 4: Dosage du formaldéhyde — Méthode par échantillonnage
diffusif
Reference number
©
ISO 2011
© ISO 2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2011 – All rights reserved
Contents Page
Foreword . iv
Introduction . vi
1 Scope . 1
2 Normative references . 1
3 Principle . 2
4 Reagents . 2
5 Apparatus . 3
6 Sampling . 4
7 Procedure . 4
7.1 Desorption and sample preparation . 4
7.2 Calibration . 4
7.3 HPLC analysis . 5
7.4 Determination of sample concentration . 6
7.5 Storage . 6
7.6 Determination of desorption efficiency . 6
8 Calculation . 6
8.1 Mass of DNPH-formaldehyde on the filter . 6
8.2 Concentration of formaldehyde in air . 7
9 Precision and uncertainty of the method . 7
10 Quality assurance/quality control . 8
11 Test report . 8
Annex A (informative) Typical designs of diffusive samplers . 9
Bibliography . 11
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 16000-4 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 6, Indoor air.
This second edition cancels and replaces the first edition (ISO 16000-4:2004), which has been technically
revised, especially 7.2.
ISO 16000 consists of the following parts, under the general title Indoor air:
Part 1: General aspects of sampling strategy
Part 2: Sampling strategy for formaldehyde
Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber
air — Active sampling method
Part 4: Determination of formaldehyde — Diffusive sampling method
Part 5: Sampling strategy for volatile organic compounds (VOCs)
Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on ®
Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations
Part 8: Determination of local mean ages of air in buildings for characterizing ventilation conditions
Part 9: Determination of the emission of volatile organic compounds from building products and
furnishing — Emission test chamber method
Part 10: Determination of the emission of volatile organic compounds from building products and
furnishing — Emission test cell method
Part 11: Determination of the emission of volatile organic compounds from building products and
furnishing — Sampling, storage of samples and preparation of test specimens
Part 12: Sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins
(PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs)
iv © ISO 2011 – All rights reserved
Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and
polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Collection on sorbent-backed filters
Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and
polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Extraction, clean-up and analysis by
high-resolution gas chromatography and mass spectrometry
Part 15: Sampling strategy for nitrogen dioxide (NO )
Part 16: Detection and enumeration of moulds — Sampling by filtration
Part 17: Detection and enumeration of moulds — Culture-based method
Part 18: Detection and enumeration of moulds — Sampling by impaction
Part 19: Sampling strategy for moulds
Part 23: Performance test for evaluating the reduction of formaldehyde concentrations by sorptive
building materials
Part 24: Performance test for evaluating the reduction of volatile organic compound (except
formaldehyde) concentrations by sorptive building materials
Part 25: Determination of the emission of semi-volatile organic compounds by building products — Micro-
chamber method
Part 26: Sampling strategy for carbon dioxide (CO )
Part 28: Determination of odour emissions from building products using test chambers
The following parts are under preparation:
Part 21: Detection and enumeration of moulds — Sampling from materials
Part 27: Determination of settled fibrous dust on surfaces by SEM (scanning electron microscopy) (direct
method)
Part 29: Test methods for VOC detectors
Part 30: Sensory testing of indoor air
Part 31: Measurement of flame retardants and plasticizers based on organophosphorus compounds —
Phosphoric acid ester
Part 32: Investigation of constructions on pollutants and other injurious factors — Inspections
Introduction
Formaldehyde has a high potential toxicity, and therefore, its determination is of interest as an indoor air
pollutant. Formaldehyde is an irritant that may cause allergic reactions and other health issues.
Formaldehyde is the simplest carbonyl compound, with one carbon, one oxygen and two hydrogen atoms. In
its monomolecular state, it is a colourless, pungent, reactive gas. It has been used in the production of urea-
formaldehyde resins, adhesives and insulating foams. Emissions from particle (chip) board and wall insulation
are the major sources of formaldehyde in indoor air.
This part of ISO 16000 is intended to be used for characterizing indoor air following the sampling strategy for
formaldehyde specified in ISO 16000-2. ISO 16000-1 gives general requirements for the measurement of
indoor air pollutants and the important conditions to be observed before or during the sampling of individual
pollutants or groups of pollutants.
An active formaldehyde measurement procedure (reference method) is specified in ISO 16000-3.
Aspects of the determination (sampling and analysis) and the sampling strategy of specific pollutants or
groups of pollutants are specified in the other parts of ISO 16000.
[6][7] [1]–[5]
ISO 16017 and ISO 12219 also focus on volatile organic compound (VOC) measurements.
vi © ISO 2011 – All rights reserved
INTERNATIONAL STANDARD ISO 16000-4:2011(E)
Indoor air —
Part 4:
Determination of formaldehyde — Diffusive sampling method
WARNING — Persons using this part of ISO 16000 should be familiar with normal laboratory practice.
This part of ISO 16000 does not purport to address all of the safety problems, if any, associated with
its use. It is the responsibility of the user to establish appropriate safety and health practices and to
ensure compliance with any national regulatory conditions.
1 Scope
This part of ISO 16000 specifies a determination of formaldehyde in indoor air using a diffusive sampler with
solvent desorption and high performance liquid chromatography (HPLC).
1 )
The test method is applicable to the measurement of formaldehyde in indoor air over the range from
3 3
0,001 mg/m to 1,0 mg/m for a sampling period of between 24 h and 72 h. For sampling periods of 24 h, the
3 3 3 3
applicable concentration range is 0,003 mg/m to 1 mg/m , and for 72 h it is 0,001 mg/m to 0,33 mg/m .
NOTE Confirmed samplers with respect to measurement sensitivity and precision can apply to short-term sampling
(less than 24 h).
The method is suitable for measurements in atmospheres with conventional indoor air relative humidity and
for monitoring at air velocities as low as 0,02 m/s. The chromatographic step in the method is designed to
eliminate potential interferences, including those due to the presence of other carbonyl compounds. The
sampling method gives a time-weighted average result.
NOTE There are several diffusive samplers with various designs and shapes commercially available. They are all
based on the reaction of 2,4-dinitrophenylhydrazine with formaldehyde. They are not specifically described in this part of
ISO 16000 to avoid any impression that ISO favours one model over another.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 16000-2, Indoor air — Part 2: Sampling strategy for formaldehyde
ISO 16000-3:2011, Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in
indoor air and test chamber air — Active sampling method
ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories
EN 13528-2, Ambient air quality — Diffusive samplers for the determination of concentrations of gases and
vapours — Requirements and test methods — Part 2: Specific requirements and test methods
1) Instead of systematic IUPAC nomenclature, traditional names are used in this part of ISO 16000, e.g. “formaldehyde”
is used instead of “methanal”.
3 Principle
The diffusive sampler is exposed to air for a defined time period. The rate of sampling depends on the
diffusion coefficient of formaldehyde, and is proportional to the cross-sectional area of the opening of the
monitor and inversely proportional to the length of the diffusion zone of the monitor. This rate is known as the
diffusive uptake rate of the sampler, and has been determined by prior calibration in a standard atmosphere.
The formaldehyde vapour migrates into the sampler by diffusion and is collected on a strip of cellulose paper
loaded with silica gel, which has been coated with 2,4-dinitrophenylhydrazine (DNPH) and phosphoric acid.
A stable hydrazone is formed which can be desorbed by acetonitrile and the solution analysed by means of a
high perfor
...
NORME ISO
INTERNATIONALE 16000-4
Deuxième édition
2011-12-01
Air intérieur —
Partie 4:
Dosage du formaldéhyde — Méthode par
échantillonnage diffusif
Indoor air
Part 4: Determination of formaldehyde — Diffusive sampling method
Numéro de référence
©
ISO 2011
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2011
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2011 – Tous droits réservés
Sommaire Page
Avant-propos . iv
Introduction . vi
1 Domaine d'application . 1
2 Références normatives . 1
3 Principe . 2
4 Réactifs . 2
5 Appareillage . 4
6 Échantillonnage . 4
7 Mode opératoire . 5
7.1 Désorption et préparation de l'échantillon . 5
7.2 Étalonnage . 5
7.3 Analyse par CLHP . 5
7.4 Détermination de la concentration de l'échantillon . 7
7.5 Stockage . 7
7.6 Détermination de l'efficacité de désorption . 7
8 Calculs . 7
8.1 Masse de DNPH-formaldéhyde sur le filtre . 7
8.2 Concentration du formaldéhyde dans l'air . 7
9 Fidélité et incertitude de la méthode . 8
10 Assurance qualité/contrôle qualité . 8
11 Rapport d'essai . 9
Annexe A (informative) Conceptions types d'échantillonneurs par diffusion . 10
Bibliographie . 12
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 16000-4 a été élaborée par le comité technique ISO/TC 146, Qualité de l'air, sous-comité SC 6, Air
intérieur.
Cette deuxième édition annule et remplace la première édition (ISO 16000-4:2004), qui a fait l'objet d'une
révision technique, en particulier en 7.2.
L'ISO 16000 comprend les parties suivantes, présentées sous le titre général Air intérieur:
Partie 1: Aspects généraux de la stratégie d'échantillonnage
Partie 2: Stratégie d'échantillonnage du formaldéhyde
Partie 3: Dosage du formaldéhyde et d'autres composés carbonylés dans l'air intérieur et dans l'air des
chambres d'essai — Méthode par échantillonnage actif
Partie 4: Dosage du formaldéhyde — Méthode par échantillonnage diffusif
Partie 5: Stratégie d'échantillonnage pour les composés organiques volatils (COV)
Partie 6: Dosage des composés organiques volatils dans l'air intérieur des locaux et chambres d'essai ®
par échantillonnage actif sur le sorbant Tenax TA , désorption thermique et chromatographie en phase
gazeuse utilisant MS ou MS-FID
Partie 7: Stratégie d'échantillonnage pour la détermination des concentrations en fibres d'amiante en
suspension dans l'air
Partie 8: Détermination des âges moyens locaux de l'air dans des bâtiments pour caractériser les
conditions de ventilation
Partie 9: Dosage de l'émission de composés organiques volatils de produits de construction et d'objets
d'équipement — Méthode de la chambre d'essai d'émission
iv © ISO 2011 – Tous droits réservés
Partie 10: Dosage de l'émission de composés organiques volatils de produits de construction et d'objets
d'équipement — Méthode de la cellule d'essai d'émission
Partie 11: Dosage de l'émission de composés organiques volatils de produits de construction et d'objets
d'équipement — Échantillonnage, conservation des échantillons et préparation d'échantillons pour essai
Partie 12: Stratégie d'échantillonnage des polychlorobiphényles (PCB), des polychlorodibenzo-p-dioxines
(PCDD), des polychlorodibenzofuranes (PCDF) et des hydrocarbures aromatiques polycycliques (HAP)
Partie 13: Dosage des polychlorobiphényles (PCB) de type dioxine et des polychlorodibenzo-p-dioxines
(PCDD)/polychlorodibenzofuranes (PCDF) totaux (en phase gazeuse et en phase particulaire) —
Collecte sur des filtres adsorbants
Partie 14: Dosage des polychlorobiphényles (PCB) de type dioxine et des polychlorodibenzo-p-dioxines
(PCDD)/polychlorodibenzofuranes (PCDF) totaux (en phase gazeuse et en phase particulaire) —
Extraction, purification et analyse par chromatographie en phase gazeuse haute résolution et
spectrométrie de masse
Partie 15: Stratégie d'échantillonnage du dioxyde d'azote (NO )
Partie 16: Détection et dénombrement des moisissures — Échantillonnage par filtration
Partie 17: Détection et dénombrement des moisissures — Méthode par culture
Partie 18: Détection et dénombrement des moisissures — Échantillonnage par impaction
Partie 19: Stratégie d'échantillonnage des moisissures
Partie 23: Essai de performance pour l'évaluation de la réduction des concentrations en formaldéhyde
par des matériaux de construction sorptifs
Partie 24: Essai de performance pour l'évaluation de la réduction des concentrations en composés
organiques volatils (sauf formaldéhyde) par des matériaux de construction sorptifs
Partie 25: Dosage de l'émission de composés organiques semi-volatils des produits de construction —
Méthode de la micro-chambre
Partie 26: Stratégie d'échantillonnage du dioxyde de carbone (CO )
Partie 28: Détermination des émissions d'odeurs des produits de construction au moyen de chambres
d'essai
Les parties suivantes sont en cours d'élaboration:
Partie 21: Détection et dénombrement des moisissures — Échantillonnage à partir de matériaux
Partie 27: Détermination de la poussière fibreuse déposée sur les surfaces par microscopie électronique
à balayage (MEB) (méthode directe)
Partie 29: Méthodes d'essai pour détecteurs de composés organiques volatils (COV)
Partie 30: Essai sensoriel de l'air intérieur
Partie 31: Mesurage des ignifugeants basés sur des composés organophosphorés — Ester d'acide
phosphorique
Partie 32: Investigation de polluants et autres facteurs nocifs dans les constructions — Inspections
Introduction
Le formaldéhyde ayant un potentiel de toxicité élevé, son dosage présente par conséquent un intérêt en tant
que polluant de l'air intérieur. Le formaldéhyde est un irritant susceptible de provoquer des réactions
allergiques et d'autres problèmes de santé.
Le formaldéhyde est le composé carbonylé le plus simple, avec un atome de carbone, un atome d'oxygène et
deux atomes d'hydrogène. Sous sa forme monomoléculaire, c'est un gaz réactif incolore et âcre. Il a été utilisé
dans la production de résines, d'adhésifs et de mousses isolantes d'urée formaldéhyde. Les émissions des
panneaux de particules (copeaux) et des isolations murales sont les principales sources de formaldéhyde
dans l'air intérieur.
La présente partie de l'ISO 16000 est destinée à être utilisée pour caractériser l'air intérieur selon la stratégie
d'échantillonnage du formaldéhyde spécifiée dans l'ISO 16000-2. L'ISO 16000-1 décrit des exigences
générales relatives au mesurage des polluants de l'air intérieur et les conditions qu'il est important de
respecter avant ou pendant l'échantillonnage de polluants ou de groupes de polluants.
Une méthode par échantillonnage actif du formaldéhyde (méthode de référence) est spécifiée dans
l'ISO 16000-3.
Les détails du dosage (échantillonnage et analyse) ainsi que la stratégie d'échantillonnage des polluants
spécifiques ou des groupes de polluants sont spécifiés dans les autres parties de l'ISO 16000.
[6][7] [1]–[5]
L'ISO 16017 et l'ISO 12219 portent également sur les mesurages relatifs aux composés organiques
volatils (COV).
vi © ISO 2011 – Tous droits réservés
NORME INTERNATIONALE ISO 16000-4:2011(F)
Air intérieur —
Partie 4:
Dosage du formaldéhyde — Méthode par échantillonnage diffusif
AVERTISSEMENT — Il convient que l'utilisateur de la présente partie de l'ISO 16000 connaisse bien
les pratiques courantes de laboratoire. La présente partie de l'ISO 16000 n'a pas pour but de traiter
tous les problèmes de sécurité qui sont, le cas échéant, liés à son utilisation. Il incombe à l'utilisateur
d'établir des pratiques appropriées en matière d'hygiène et de sécurité et de s'assurer de la
conformité à la réglementation nationale en vigueur.
1 Domaine d'application
La présente partie de l'ISO 16000 spécifie un dosage du formaldéhyde dans l'air intérieur au moyen d'un
échantillonneur par diffusion avec désorption de solvant et chromatographie en phase liquide à haute
performance (CLHP).
1)
La méthode d'essai s'applique au mesurage du formaldéhyde dans l'air intérieur dans une gamme comprise
3 3
entre 0,001 mg/m et 1,0 mg/m pour une période d'échantillonnage comprise entre 24 h et 72 h. Pour des
périodes d'échantillonnage de 24 h, la gamme de concentration applicable est comprise entre 0,003 mg/m et
3 3 3
1 mg/m , et pour des périodes de 72 h, elle est comprise entre 0,001 mg/m et 0,33 mg/m .
NOTE Des échantillonneurs validés en termes de sensibilité et de fidélité de mesurage peuvent être utilisés pour
l'échantillonnage à court terme (moins de 24 h).
La méthode convient à des mesurages réalisés dans des atmosphères ayant une humidité relative dans l'air
intérieur normale et pour la surveillance à des vitesses d'air de l'ordre de 0,02 m/s. L'étape de
chromatographie prévue dans la méthode est destinée à permettre l'élimination des interférences potentielles,
notamment celles dues à la présence d'autres composés carbonylés. La méthode d'échantillonnage fournit un
résultat moyen pondéré dans le temps.
NOTE Il existe plusieurs échantillonneurs par diffusion de conceptions et de formes différentes disponibles dans le
commerce. Ils reposent tous sur la réaction de la 2,4-dinitrophénylhydrazine avec le formaldéhyde. Ils ne sont pas
spécifiquement décrits dans la présente partie de l'ISO 16000 pour éviter toute impression que l'ISO favorise un modèle
plutôt qu'un autre.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 16000-2, Air intérieur — Partie 2: Stratégie d'échantillonnage du formaldéhyde
ISO 16000-3:2011, Air intérieur — Partie 3: Dosage du fo
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.