General Information

Abstract

Functional requirements for the regenerator section  and multiplex sec tion layer of SDH interfaces on all types of equipment based on the ge neric principles described in part 1-1.

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003

Buy Documents

Standard

SIST EN 300 417-3-1 V1.1.3:2003

English language (174 pages)
Preview
Preview
e-Library read for
×1 day

Overview

SIST EN 300 417-3-1 V1.1.3:2003 specifies the generic requirements for the transport functionality of Synchronous Transport Module-N (STM-N) regenerator and multiplex section layers in telecommunications equipment. Developed by the Slovenski inštitut za standardizacijo (SIST) and harmonized with the European Standard EN 300 417-3-1, this document forms part of a series standardizing functional aspects of Synchronous Digital Hierarchy (SDH) and related transmission systems across Europe.

This standard outlines a modular library of functional building blocks and rules for their interconnection, enabling manufacturers and network operators to describe and implement the necessary transport functionalities for SDH-compliant equipment at various STM-N levels, such as STM-1, STM-4, STM-16, and STM-64. By providing standardized functions and interfaces, SIST EN 300 417-3-1 facilitates inter-vendor and inter-operator compatibility, ensuring robust, scalable, and efficient SDH transport networks.

Key Topics

  • Regenerator Section Layer Functions: Definitions and requirements for STM-N regenerator section functions, including connection, trail termination, and adaptation processes.
  • Multiplex Section Layer Functions: Standardized functions for multiplex section connections, trail termination, adaptation, monitoring, and protection.
  • Atomic Functional Blocks: A comprehensive library of atomic functions and clear rules for combining them to specify the SDH transport functionality at the regenerator and multiplex section layers.
  • Protection Mechanisms: Standardized procedures and architectures for linear trail protection (such as 1+1 and 1:n protection schemes) and shared protection rings, supporting network reliability and service continuity.
  • Interface Definitions: Specification of information structure, signals, and adaptation points at various demarcations within the STM-N hierarchy.
  • Frame Structure: Alignment with key SDH frame and overhead structures as defined in referenced standards, ensuring consistency and interoperability.
  • Conformance to European and International SDH Transport Requirements: References to related EN and ITU-T documents for completeness and compatibility.

Applications

The requirements of SIST EN 300 417-3-1 V1.1.3:2003 are foundational for:

  • Network Equipment Manufacturers: Designing, developing, and testing SDH transmission equipment such as multiplexers, regenerators, and add-drop multiplexers to ensure compliance with European SDH transport standards.
  • Telecommunications Operators: Deploying multi-vendor SDH transport networks that demand high interoperability, service reliability, and efficient management of multiplex section and regenerator section layers.
  • SDH Network Design: Supporting the planning and engineering of SDH transport networks, including adaptation and protection schemes for various STM-N levels.
  • Interoperability Testing: Providing reference criteria for verifying equipment conformance and facilitating smooth integration into existing telecommunication infrastructures.

Related Standards

For comprehensive SDH transmission solutions and full compliance, consider the following related documents:

  • EN 300 417-1-1: Generic processes and performance requirements for transport functionality of equipment.
  • EN 300 417-4-1: Synchronous Digital Hierarchy (SDH) path layer functions.
  • EN 300 417-6-1: Synchronization distribution layer functions for SDH equipment.
  • ETS 300 147: SDH multiplexing structure.
  • ITU-T Recommendation G.783: Characteristics of SDH equipment functional blocks.
  • ETS 300 746: SDH network protection schemes, including Automatic Protection Switching (APS) protocols.

Practical Value

By adopting SIST EN 300 417-3-1 V1.1.3:2003, organizations benefit from:

  • Enhanced interoperability within European and international SDH networks.
  • Alignment with industry best practices for SDH transport equipment.
  • Improved network reliability and performance due to standardized protection and monitoring functions.
  • Streamlined equipment certification and simplified integration processes, supporting both legacy and next-generation transmission systems.

Keywords: Synchronous Digital Hierarchy, SDH, STM-N, regenerator section, multiplex section, transmission equipment, telecommunications standards, European standard, network protection, interoperability.

Buy Documents

Standard

SIST EN 300 417-3-1 V1.1.3:2003

English language (174 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 300 417-3-1 V1.1.3:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 3-1: Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions". This standard covers: Functional requirements for the regenerator section and multiplex sec tion layer of SDH interfaces on all types of equipment based on the ge neric principles described in part 1-1.

Functional requirements for the regenerator section and multiplex sec tion layer of SDH interfaces on all types of equipment based on the ge neric principles described in part 1-1.

SIST EN 300 417-3-1 V1.1.3:2003 is classified under the following ICS (International Classification for Standards) categories: 33.040.20 - Transmission systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 300 417-3-1 V1.1.3:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.XQNFLRQDOQRVWTransmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 3-1: Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions33.040.20Prenosni sistemTransmission systemsICS:Ta slovenski standard je istoveten z:EN 300 417-3-1 Version 1.1.3SIST EN 300 417-3-1 V1.1.3:2003en01-december-2003SIST EN 300 417-3-1 V1.1.3:2003SLOVENSKI
STANDARD
EN 300 417-3-1 V1.1.3 (1999-05)European Standard (Telecommunications series)Transmission and Multiplexing (TM);Generic requirements of transport functionality of equipment;Part 3-1: Synchronous Transport Module-N (STM-N)regenerator and multiplex section layer functionsSIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)2ReferenceREN/TM-01015-3-1a (3v0r9ie0.PDF)Keywordstransmission, SDH, interfaceETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frhttp://www.etsi.orgCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1998.All rights reserved.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)3ContentsIntellectual Property Rights.7Foreword.71Scope.92References.93Definitions, abbreviations and symbols.103.1Definitions.103.2Abbreviations.103.3Symbols and Diagrammatic Conventions.123.4Introduction.124STM-1 Regenerator Section Layer Functions.134.1STM-1 Regenerator Section Connection functions.144.2STM-1 Regenerator Section Trail Termination functions.144.2.1STM-1 Regenerator Section Trail Termination Source RS1_TT_So.144.2.2STM-1 Regenerator Section Trail Termination Sink RS1_TT_Sk.164.3STM-1 Regenerator Section Adaptation functions.184.3.1STM-1 Regenerator Section to Multiplex Section Adaptation Source RS1/MS1_A_So.184.3.2STM-1 Regenerator Section to Multiplex Section Adaptation Sink RS1/MS1_A_Sk.194.3.3STM-1 Regenerator Section to DCC Adaptation Source RS1/DCC_A_So.204.3.4STM-1 Regenerator Section to DCC Adaptation Sink RS1/DCC_A_Sk.214.3.5STM-1 Regenerator Section to P0s Adaptation Source RS1/P0s_A_So/N.224.3.6STM-1 Regenerator Section to P0s Adaptation Sink RS1/P0s_A_Sk/N.234.3.7STM-1 Regenerator Section toV0x Adaptation Source RS1/V0x_A_So.244.3.8STM-1 Regenerator Section to V0x Adaptation Sink RS1/V0x_A_Sk.255STM-1 Multiplex Section Layer Functions.265.1STM-1 Multiplex Section Connection functions.285.2STM-1 Multiplex Section Trail Termination functions.285.2.1STM-1 Multiplex Section Trail Termination Source MS1_TT_So.285.2.2STM-1 Multiplex Section Trail Termination Sink MS1_TT_Sk.295.3STM-1 Multiplex Section Adaptation functions.325.3.1STM-1 Multiplex Section to S4 Layer Adaptation Source MS1/S4_A_So.325.3.2STM-1 Multiplex Section to S4 Layer Adaptation Sink MS1/S4_A_Sk.355.3.3STM-1 Multiplex Section to DCC Adaptation Source MS1/DCC_A_So.375.3.4STM-1 Multiplex Section to DCC Adaptation Sink MS1/DCC_A_Sk.375.3.5STM-1 Multiplex Section to P0s Adaptation Source MS1/P0s_A_So.385.3.6STM-1 Multiplex Section to P0s Adaptation Sink MS1/P0s_A_Sk.405.3.7STM-1 Multiplex Section to Synchronization Distribution Adaptation Source MS1/SD_A_So.415.3.8STM-1 Multiplex Section to Synchronization Distribution Adaptation Sink MS1/SD_A_Sk.415.3.9STM-1 Multiplex Section Layer Clock Adaptation Source MS1-LC_A_So.415.4STM-1 Multiplex Section Layer Monitoring Functions.415.5STM-1 Multiplex Section Linear Trail Protection Functions.415.5.1STM-1 Multiplex Section Linear Trail Protection Connection Functions.415.5.1.1STM-1 Multiplex Section 1+1 Linear Trail Protection Connection MS1P1+1_C.415.5.1.2STM-1 Multiplex Section 1:n Linear Trail Protection Connection MS1P1:n_C.445.5.2STM-1 Multiplex Section Linear Trail Protection Trail Termination Functions.465.5.2.1Multiplex Section Protection Trail Termination Source MS1P_TT_So.465.5.2.2Multiplex Section Protection Trail Termination Sink MS1P_TT_Sk.475.5.3STM-1 Multiplex Section Linear Trail Protection Adaptation Functions.485.5.3.1STM-1 Multiplex Section to STM-1 Multiplex Section Protection Layer Adaptation SourceMS1/MS1P_A_So.485.5.3.2STM-1 Multiplex Section to STM-1 Multiplex Section Protection Layer Adaptation SinkMS1/MS1P_A_Sk.49SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)46STM-4 Regenerator Section Layer Functions.506.1STM-4 Regenerator Section Connection functions.516.2STM-4 Regenerator Section Trail Termination functions.516.2.1STM-4 Regenerator Section Trail Termination Source RS4_TT_So.516.2.2STM-4 Regenerator Section Trail Termination Sink RS4_TT_Sk.546.3STM-4 Regenerator Section Adaptation functions.566.3.1STM-4 Regenerator Section to Multiplex Section Adaptation Source RS4/MS4_A_So.566.3.2STM-4 Regenerator Section to Multiplex Section Adaptation Sink RS4/MS4_A_Sk.576.3.3STM-4 Regenerator Section to DCC Adaptation Source RS4/DCC_A_So.586.3.4STM-4 Regenerator Section to DCC Adaptation Sink RS4/DCC_A_Sk.596.3.5STM-4 Regenerator Section to P0s Adaptation Source RS4/P0s_A_So/N.606.3.6STM-4 Regenerator Section to P0s Adaptation Sink RS4/P0s_A_Sk/N.616.3.7STM-4 Regenerator Section to V0x Adaptation Source RS4/V0x_A_So.626.3.8STM-4 Regenerator Section to V0x Adaptation Sink RS4/V0x_A_Sk.637STM-4 Multiplex Section Layer Functions.647.1STM-4 Multiplex Section Connection functions.667.2STM-4 Multiplex Section Trail Termination functions.677.2.1STM-4 Multiplex Section Trail Termination Source MS4_TT_So.677.2.2STM-4 Multiplex Section Trail Termination Sink MS4_TT_Sk.697.3STM-4 Multiplex Section Adaptation functions.727.3.1STM-4 Multiplex Section to S4 Layer Adaptation Source MS4/S4_A_So/N.727.3.2STM-4 Multiplex Section to S4 Layer Adaptation Sink MS4/S4_A_Sk/N.757.3.3STM-4 Multiplex Section to S4-4c Layer Adaptation Source MS4/S4-4c_A_So.777.3.4STM-4 Multiplex Section to S4-4c Layer Adaptation Sink MS4/S4-4c_A_Sk.807.3.5STM-4 Multiplex Section to DCC Adaptation Source MS4/DCC_A_So.827.3.6STM-4 Multiplex Section to DCC Adaptation Sink MS4/DCC_A_Sk.837.3.7STM-4 Multiplex Section to P0s Adaptation Source MS4/P0s_A_So.847.3.8STM-4 Multiplex Section to P0s Adaptation Sink MS4/P0s_A_Sk.857.3.9STM-4 Multiplex Section to Synchronization Distribution Adaptation Source MS4/SD_A_So.867.3.10STM-4 Multiplex Section to Synchronization Distribution Adaptation Sink MS4/SD_A_Sk.867.3.11STM-4 Multiplex Section Layer Clock Adaptation Source MS4-LC_A_So.867.4STM-4 Multiplex Section Layer Monitoring Functions.867.5STM-4 Multiplex Section Linear Trail Protection Functions.867.5.1STM-4 Multiplex Section Linear Trail Protection Connection Functions.867.5.1.1STM-4 Multiplex Section 1+1 Linear Trail Protection Connection MS4P1+1_C.867.5.1.2STM-4 Multiplex Section 1:n Linear Trail Protection Connection MS4P1:n_C.897.5.2STM-4 Multiplex Section Linear Trail Protection Trail Termination Functions.917.5.2.1Multiplex Section Protection Trail Termination Source MS4P_TT_So.917.5.2.2Multiplex Section Protection Trail Termination Sink MS4P_TT_Sk.927.5.3STM-4 Multiplex Section Linear Trail Protection Adaptation Functions.937.5.3.1STM-4 Multiplex Section to STM-4 Multiplex Section Protection Layer Adaptation SourceMS4/MS4P_A_So.937.5.3.2STM-4 Multiplex Section to STM-4 Multiplex Section Protection Layer Adaptation SinkMS4/MS4P_A_Sk.948STM-16 Regenerator Section Layer Functions.958.1STM-16 Regenerator Section Connection functions.968.2STM-16 Regenerator Section Trail Termination functions.968.2.1STM-16 Regenerator Section Trail Termination Source RS16_TT_So.968.2.2STM-16 Regenerator Section Trail Termination Sink RS16_TT_Sk.998.3STM-16 Regenerator Section Adaptation functions.1018.3.1STM-16 Regenerator Section to Multiplex Section Adaptation Source RS16/MS16_A_So.1018.3.2STM-16 Regenerator Section to Multiplex Section Adaptation Sink RS16/MS16_A_Sk.1028.3.3STM-16 Regenerator Section to DCC Adaptation Source RS16/DCC_A_So.1038.3.4STM-16 Regenerator Section to DCC Adaptation Sink RS16/DCC_A_Sk.1048.3.5STM-16 Regenerator Section to P0s Adaptation Source RS16/P0s_A_So/N.1058.3.6STM-16 Regenerator Section to P0s Adaptation Sink RS16/P0s_A_Sk/N.1068.3.7STM-16 Regenerator Section to V0x Adaptation Source RS16/V0x_A_So.1078.3.8STM-16 Regenerator Section to V0x Adaptation Sink RS16/V0x_A_Sk.108SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)59STM-16 Multiplex Section Layer Functions.1099.1STM-16 Multiplex Section Connection functions.1149.2STM-16 Multiplex Section Trail Termination functions.1149.2.1STM-16 Multiplex Section Trail Termination Source MS16_TT_So.1149.2.2STM-16 Multiplex Section Trail Termination Sink MS16_TT_Sk.1169.3STM-16 Multiplex Section Adaptation functions.1189.3.1STM-16 Multiplex Section to S4 Layer Adaptation Source MS16/S4_A_So/N.1189.3.2STM-16 Multiplex Section to S4 Layer Adaptation Sink MS16/S4_A_Sk/N.1219.3.3STM-16 Multiplex Section to S4-4c Layer Adaptation Source MS16/S4-4c_A_So/N.1239.3.4STM-16 Multiplex Section to S4-4c Layer Adaptation Sink MS16/S4-4c_A_Sk/N.1269.3.5STM-16 Multiplex Section to DCC Adaptation Source MS16/DCC_A_So.1289.3.6STM-16 Multiplex Section to DCC Adaptation Sink MS16/DCC_A_Sk.1299.3.7STM-16 Multiplex Section to P0s Adaptation Source MS16/P0s_A_So.1309.3.8STM-16 Multiplex Section to P0s Adaptation Sink MS16/P0s_A_Sk.1319.3.9STM-16 Multiplex Section to Synchronization Distribution Adaptation Source MS16/SD_A_So.1329.3.10STM-16 Multiplex Section to Synchronization Distribution Adaptation Sink MS16/SD_A_Sk.1329.3.11STM-16 Multiplex Section Layer Clock Adaptation Source MS16-LC_A_So.1329.4STM-16 Multiplex Section Layer Monitoring Functions.1329.5STM-16 Multiplex Section Linear Trail Protection Functions.1329.5.1STM-16 Multiplex Section Linear Trail Protection Connection Functions.1329.5.1.1STM-16 Multiplex Section 1+1 Linear Trail Protection Connection MS16P1+1_C.1329.5.1.2STM-16 Multiplex Section 1:n Linear Trail Protection Connection MS16P1:n_C.1359.5.2STM-16 Multiplex Section Linear Trail Protection Trail Termination Functions.1379.5.2.1Multiplex Section Protection Trail Termination Source MS16P_TT_So.1379.5.2.2Multiplex Section Protection Trail Termination Sink MS16P_TT_Sk.1389.5.3STM-16 Multiplex Section Linear Trail Protection Adaptation Functions.1399.5.3.1STM-16 Multiplex Section to STM-16 Multiplex Section Protection Layer Adaptation SourceMS16/MS16P_A_So.1399.5.3.2STM-16 Multiplex Section to STM-16 Multiplex Section Protection Layer Adaptation SinkMS16/MS16P_A_Sk.1409.6STM-16 Multiplex Section 2 Fibre Shared Protection Ring Functions.1419.6.1STM-16 Multiplex Section 2 Fibre Shared Protection Ring Connection MS16P2fsh_C.1419.6.2STM-16 Multiplex Section 2 Fibre Shared Protection Ring Trail Termination Functions.1459.6.2.1STM-16 Multiplex Section 2 Fibre Shared Protection Ring Trail Termination SourceMS16P2fsh_TT_So.1459.6.2.2STM-16 Multiplex Section 2 Fibre Shared Protection Ring Trail Termination SinkMS16P2fsh_TT_Sk.1469.6.3STM-16 Multiplex Section 2 Fibre Shared Protection Ring Adaptation Functions.1479.6.3.1STM-16 Multiplex Section to STM-16 Multiplex Section 2 Fibre Shared Protection RingAdaptation Source MS16/MS16P2fsh_A_So.1479.6.3.2STM-16 Multiplex Section to STM-16 Multiplex Section 2 Fibre Shared Protection RingAdaptation Sink MS16/MS16P2fsh_A_Sk.1489.7STM-16 Multiplex Section 4 Fibre Shared Protection Ring Functions.1499.7.1STM-16 Multiplex Section 4 Fibre Shared Protection Ring Connection MS16P4fsh_C.1499.7.2STM-16 Multiplex Section 4 Fibre Shared Protection Ring Trail Termination Functions.1499.7.2.1STM-16 Multiplex Section 4 Fibre Shared Protection Ring Trail Termination SourceMS16P4fsh_TT_So.1499.7.2.2STM-16 Multiplex Section 4 Fibre Shared Protection Ring Trail Termination SinkMS16P4fsh_TT_Sk.1499.7.3STM-16 Multiplex Section 4 Fibre Shared Protection Ring Adaptation Functions.1499.7.3.1STM-16 Multiplex Section to STM-16 Multiplex Section 4 Fibre Shared Protection RingAdaptation Source MS16/MS16P4fsh_A_So.1499.7.3.2STM-16 Multiplex Section to STM-16 Multiplex Section 4 Fibre Shared Protection RingAdaptation Sink MS16/MS16P4fsh_A_Sk.149SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)610STM-64 Regenerator Section layer functions.14911STM-64 Multiplex Section layer functions.149Annex A (normative):Generic specification of linear protection switching operation.150A.1Protection process overview.151A.2External switch commands definition.152A.3Conditions of working and protection trail / connections.153A.4States within protection process.153A.5Numbering of working, protection, normal, extra traffic, null signals.154A.6Priority of request types (conditions, external commands, states).155A.7APS signal definition.156A.7.1APS signal fields.156A.7.2STM-N MS-APS.157A.7.3STM-N VC-APS.158A.8Switch performance: switching and holdoff times.158A.9Subprocesses.158Annex B (informative):STM-16 regenerator functional model (example).166Annex C (informative):AU-4-Xc numbering scheme & pointer allocation.167Annex D (informative):MS protection examples.171Bibliography.173History.174SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)7Intellectual Property RightsIPRs essential or potentially essential to the present document may have been declared to ETSI. The informationpertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be foundin SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respectof ETSI standards", which is available free of charge from the ETSI Secretariat. Latest updates are available on theETSI Web server (http://www.etsi.org/ipr).Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guaranteecan be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)which are, or may be, or may become, essential to the present document.ForewordThis European Standard (Telecommunications series) has been produced by ETSI Technical Committee Transmissionand Multiplexing (TM).The present document is one of a family of documents that has been produced in order to provide inter-vendor andinter-operator compatibility of Synchronous Digital Hierarchy (SDH) equipment.The present document is part 3-1 of a multi-part EN covering the generic requirements of transport functionality ofequipment, as identified below:Part 1-1:"Generic processes and performance".Part 1-2:"General information about Implementation Conformance Statement (ICS) proforma".Part 2-1:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical sectionlayer functions".Part 2-2:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical sectionlayer functions; Implementation Conformance Statement (ICS) proforma specification".Part 3-1:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions".Part 3-2:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions;Implementaion Conformance Statement (ICS) proforma specification".Part 4-1:"Synchronous Digital Hierarchy (SDH) path layer functions".Part 4-2:"Synchronous Digital Hierarchy (SDH) path layer functions; Implementation Conformance Statement(ICS) proforma specification".Part 5-1:"Plesiochronous Digital Hierarchy (PDH) path layer functions".Part 5-2:"Plesiochronous Digital Hierarchy (PDH) path layer functions; Implementation Conformance Statement(ICS) proforma specification".Part 6-1:"Synchronization layer functions".Part 6-2:"Synchronization layer functions; Implementation Conformance Statement (ICS) proforma specification".Part 7-1:"Auxiliary layer functions".Part 7-2:"Auxiliary layer functions; Implementation Conformance Statement (ICS) proforma specification".Parts 2 to 7 specify the layers and their atomic functions.NOTE 1:The present document does not currently address configuration management.NOTE 2:The SDH radio equipment functional blocks are addressed by ETSI WG TM4.Various of the above parts have previously been published as parts of ETS 300 417.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)8They have been converted into parts of EN 300 417 without technical changes, but some editorial changes have beennecessary (e.g. references). In particular:-Parts 2-1, 2-2 and 3-2 have been modified to take account of editorial errors present in edition 1.-Part 1-1 has had its title change of to align with other parts published at a later date.Also note that in the meantime parts 8-1 and 8-2 together will all parts x-3 (Abstract Test Suites) have been stopped.This version of the present document has been published because the previous version had incorrect dates in thetransposition table.National transposition datesDate of latest announcement of this EN (doa):31 August 1999Date of latest publication of new National Standardor endorsement of this EN (dop/e):29 February 2000Date of withdrawal of any conflicting National Standard (dow):29 February 2000SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)91ScopeThe present document specifies a library of basic building blocks and a set of rules by which they are combined in orderto describe transport functionality of equipment. The library comprises the functional building blocks needed tocompletely specify the generic functional structure of the European Transmission Hierarchies. Equipment which iscompliant with the present document needs to be describable as an interconnection of a subset of these functional blockscontained within the present document. The interconnections of these blocks need to obey the combination rules given.The generic functionality is described in EN 300 417-1-1 [3].2ReferencesThe following documents contain provisions which, through reference in this text, constitute provisions of the presentdocument.· References are either specific (identified by date of publication, edition number, version number, etc.) ornon-specific.· For a specific reference, subsequent revisions do not apply.· For a non-specific reference, the latest version applies.· A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the samenumber.[1]ETS 300 147: "Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH);Multiplexing structure".[2]ETS 300 166 (1993): "Transmission and Multiplexing (TM); Physical and electrical characteristicsof hierarchical digital interfaces for equipment using the 2 048 kbit/s - based plesiochronous orsynchronous digital hierarchies".[3]EN 300 417-1-1: "Transmission and Multiplexing (TM); Generic requirements of transportfunctionality of equipment; Part 1-1: Generic processes and performance".[4]EN 300 417-4-1: "Transmission and Multiplexing (TM); Generic requirements of transportfunctionality of equipment; Part 4-1: Synchronous Digital Hierarchy (SDH) path layer functions".[5]EN 300 417–6–1: "Transmission and Multiplexing (TM); Generic requirements of transportfunctionality of equipment; Part 6-1: Synchronization distribution layer functions".[6]ETS 300 746: "Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH);Network protection schemes; Automatic Protection Switch (APS) protocols and operation".[7]ITU-T Recommendation G.783: "Characteristics of synchronous digital hierarchy (SDH)equipment functional blocks".SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)103Definitions, abbreviations and symbols3.1DefinitionsThe functional definitions are described in EN 300 417-1-1 [3].3.2AbbreviationsFor the purposes of the present document, the following abbreviations apply:AAdaptation functionAcTIAccepted Trace IdentifierADMAdd-Drop MultiplexerAIAdapted InformationAISAlarm Indication SignalAPAccess PointAPIdAccess Point IdentifierAPSAutomatic Protection SwitchAUAdministrative UnitAUGAdministrative Unit GroupAU-nAdministrative Unit, level nBERBit Error RatioBIPBit Interleaved ParityBIP-NBit Interleaved Parity, width NCConnection functionCICharacteristic InformationCKClocKCMConnection MatrixCPConnection PointCSClock SourceDDataDCC Data Communications ChannelDECDECrementDEGDEGradedDEGTHRDEGraded THResholdEBCErrored Block CountECCEmbedded Communications ChannelECC(x)Embedded Communications Channel, layer xEDCError Detection CodeEDCVError Detection Code ViolationEMFEquipment Management FunctionEQEQuipmentESElectrical SectionESErrored SecondExTIExpected Trace IdentifierF_BFar-end BlockFASFrame Alignment SignalFOPFailure Of ProtocolFSFrame Start signalHOHigher OrderHOVCHigher Order Virtual ContainerHPHigher order PathIDIDentifierIFIn Frame stateINCINCrementINVINValidLCLink ConnectionLOLower OrderSIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)11LOALoss Of Alignment; generic for LOF, LOM, LOPLOFLoss Of FrameLOPLoss Of PointerLOSLoss Of SignalLOVCLower Order Virtual ContainerMCMatrix ConnectionMCFMessage Communications FunctionMDTMean Down Timemeimaintenance event informationMIManagement InformationMOManaged ObjectMONMONitoredMPManagement PointMSMultiplex SectionMS1STM-1 Multiplex SectionMS16STM-16 Multiplex SectionMS4STM-4 Multiplex SectionMSBMost Significant BitMSOHMultiplex Section OverHeadMSPMultiplex Section ProtectionMSPGMultiplex Section Protection GroupNCNot ConnectedN_BNear-end BlockNCNetwork ConnectionNDFNew Data FlagNENetwork ElementNMONNot MONitoredNNINetwork Node InterfaceNUNational Use (bits, bytes)NUxNational Use, bit rate order xOAMOperation, Administration and MaintenanceOFSOut of Frame SecondOOFOut Of Frame stateOSOptical SectionOSI(x)Open Systems Interconnection, layer xOWOrder WirePProtectionP_AProtection AdaptationP_CProtection ConnectionP_TTProtection Trail TerminationPDHPlesiochronous Digital HierarchyPJEPointer Justification EventPMPerformance MonitoringPnPlesiochronous signal, level nPOHPath OverHeadPRCPrimary Reference ClockPSProtection SwitchingPSCProtection Switch CountPTRPoinTeRQOSQuality Of ServiceRDIRemote Defect IndicationREIRemote Error IndicationRIRemote InformationRPRemote PointRSRegenerator SectionRS1STM-1 Regenerator SectionRS16STM-16 Regenerator SectionRS4STM-4 Regenerator SectionRSOHRegenerator Section OverHeadRxTIReceived Trace IdentifierSIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)12S4VC-4 path layerSASEStand-Alone Synchronization EquipmentSDSynchronization Distribution layer, Signal DegradeSDHSynchronous Digital HierarchySECSDH Equipment ClockSFSignal FailSkSinkSNCSub-Network ConnectionSNC/IInherently monitored Sub-Network Connection protectionSNC/NNon-intrusively monitored Sub-Network Connection protectionSNC/SSublayer monitored Sub-Network Connection protectionSoSourceSOHSection OverHeadSPRINGShared Protection RINGSRSelected ReferenceSSDServer Signal DegradeSSFServer Signal FailSSMSynchronization Status MessageSSUSynchronization Supply UnitSTMSynchronous Transport ModuleSTM-NSynchronous Transport Module, level NTCPTermination Connection PointTITiming InformationTIMTrace Identifier MismatchTMTransmission_MediumTMNTelecommunications Management NetworkTPTiming PointTPmodeTermination Point modeTSTime SlotTSDTrail Signal DegradeTSFTrail Signal FailTTTrail Termination functionTTITrail Trace IdentifierTTsTrail Termination supervisory functionTxTITransmitted Trace IdentifierUNEQUNEQuippedUNIUser Network InterfaceUSRUSeR channelsV064 kbit/s contradirectional data layerVCVirtual ContainerVC-nVirtual Container, level-nWWorking3.3Symbols and Diagrammatic ConventionsThe symbols and diagrammatic conventions are described in EN 300 417-1-1 [3].3.4IntroductionThe atomic functions defining the regenerator and multiplex section layers are described below (clause 4 onwards).SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)134STM-1 Regenerator Section Layer FunctionsRS1RS1/MS1RS1RS1/MS1MS1_CIMS1_CIRS1_CIRS1_CIRS1/V0xRS1/V0xRS1/P0s-NP0s_CISTM1_TIRS1/P0s-NP0s_CIE1,F1E1,F1V0x_CIV0x_CIRS1/DCCDCC_CIF1D1-D3RS1/DCCDCC_CID1-D3F1RS1_AIRS1_AIRS1Figure 1: STM-1 Regenerator Section atomic functionsRS1 Layer CPThe CI at this point is an octet structured, 125 ms framed data stream with co-directional timing. It is the entire STM-1signal as defined in ETS 300 147 [1]. Figure 2 depicts only bytes handled in the RS1 layer.NOTE 1:The unmarked bytes [2, 6], [3, 6], [3, 8], [3, 9] in rows 2,3 (figure 2) are reserved for future internationalstandardization. Currently, they are undefined.NOTE 2:The unmarked bytes [2, 2], [2, 3], [2, 5], [3, 2], [3, 3], [3, 5] in rows 2,3 (figure 2) are reserved for mediaspecific usage (e.g. radio sections). In optical and electrical section applications they are undefined.NOTE 3:The bytes for National Use (NU) in rows 1,2 (figure 2) are reserved for operator specific usage. Theirprocessing is not within the province of the present document. If NU bytes [1, 8] and [1, 9] are unused,care should be taken in selecting the binary content of the bytes which are excluded from the scramblingprocess of the STM-N signal to ensure that long sequences of "1"s or "0"s do not occur.12345678910.2701A1A1A1A2A2A2J0NUNU2B1E1F1NUNU3D1D2D3456MS1_CI789Figure 2: RS1_CI_D signalRS1 Layer APThe AI at this point is octet structured and 125 ms framed with co-directional timing and represents the combination ofadapted information from the MS1 layer (2 403 bytes per frame), the management communication DCC layer (3 bytesper frame if supported), the OW layer (1 byte per frame if supported) and the user channel F1 (1 byte per frame ifsupported). The location of these four components in the frame is defined in ETS 300 147 [1] and depicted in figure 3.NOTE 4:Bytes E1, F1 and D1-D3 will be undefined when the adaptation functions sourcing these bytes are notpresent in the network element.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)1412345678910.2701NUNU2E1F1NUNU3D1D2D3456MS1_CI789Figure 3: RS1_AI_D signal4.1STM-1 Regenerator Section Connection functionsFor further study.4.2STM-1 Regenerator Section Trail Termination functions4.2.1STM-1 Regenerator Section Trail Termination Source RS1_TT_SoSymbol:RS1RS1_AIRS1_CIRS1_TT_So_MIFigure 4: RS1_TT_So symbolInterfaces:Table 1: RS1_TT_So input and output signalsInput(s)Output(s)RS1_AI_DRS1_AI_CKRS1_AI_FSRS1_TT_So_MI_TxTIRS1_CI_DRS1_CI_CKProcesses:The function builds the STM-1 signal by adding the frame alignment information, bytes A1A2, the STM Section TraceIdentifier (STI) byte J0, computing the parity and inserting the B1 byte.J0: In this byte the function shall insert the Transmitted Trail Trace Identifier TxTI. Its format is described inEN 300 417-1-1 [3], subclause 7.1.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)15B1: The function shall calculate a Bit Interleaved Parity 8 (BIP-8) code using even parity. The BIP-8 shall be calculatedover all bits of the previous STM-1 frame after scrambling and is placed in byte position B1 of the current STM-1 framebefore scrambling (figure 5).A1A2: The function shall insert the STM-1 frame alignment signal A1A1A1A2A2A2 into the regenerator sectionoverhead as defined in ETS 300 147 [1].Scrambler: This function provides scrambling of the RS1_CI. The operation of the scrambler shall be functionallyidentical to that of a frame synchronous scrambler of sequence length 127 operating at the line rate. The generatingpolynomial shall be 1 + X6 + X7. The scrambler shall be reset to "1111 1111" on the most significant bit (MSB) of thebyte [1, 10] following the last byte of the STM-1 SOH in the first row. This bit and all subsequent bits to be scrambledshall be modulo 2 added to the output of the X7 position of the scrambler. The scrambler shall run continuouslythroughout the remaining STM-1 frame.SCRAMBLERBIP-8COMPUTATIONB1RS_CIRS TRACE IDINSERTIONJ0FAS INSERTIONRS_AIA1A2TxTIFigure 5: Some processes within RS1_TT_SoDefects:None.Consequent Actions:None.Defect Correlations:None.Performance Monitoring:None.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)164.2.2STM-1 Regenerator Section Trail Termination Sink RS1_TT_SkSymbol:RS1RS1_AIRS1_CIRS1_TT_Sk_MIFigure 6: RS1_TT_Sk symbolInterfaces:Table 2: RS1_TT_Sk input and output signalsInput(s)Output(s)RS1_CI_DRS1_CI_CKRS1_CI_FSRS1_CI_SSFRS1_TT_Sk_MI_ExTIRS1_TT_Sk_MI_TPmodeRS1_TT_Sk_MI_TIMdisRS1_TT_Sk_MI_ExTImodeRS1_TT_Sk_MI_1secondRS1_AI_DRS1_AI_CKRS1_AI_FSRS1_AI_TSFRS1_TT_Sk_MI_AcTIRS1_TT_Sk_MI_cTIMRS1_TT_Sk_MI_pN_EBCRS1_TT_Sk_MI_pN_DSProcesses:This function monitors the STM-1 signal for RS errors, and recovers the RS trail termination status. It extracts thepayload independent overhead bytes (J0, B1) from the RS1 layer Characteristic Information:Descrambling: The function shall descramble the incoming STM-1 signal. The operation of the descrambler shall befunctionally identical to that of a scrambler in OS1/RS1_A_So.B1: Even bit parity is computed for each bit n of every byte of the preceding scrambled STM-1 frame and comparedwith bit n of B1 recovered from the current frame (n = 1 to 8 inclusive) (figure 7). A difference between the computedand recovered B1 values is taken as evidence of one or more errors (nN_B) in the computation block.J0: The Received Trail Trace Identifier RxTI shall be recovered from the J0 byte and shall be made available as AcTIfor network management purposes. The application and acceptance and mismatch detection process shall be performedas specified in EN 300 417-1-1 [3], subclauses 7.1 and 8.2.1.3.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)17DESCRAMBLERBIP-8COMPUTATIONB1J0RS1_CICOMPARISONBIP-8violationsAcTIdTIMExTIRS1_AITIMdisRS TRACE IDPROCESSExTImodeFigure 7: Some processes within RS1_TT_SkDefects:The function shall detect for dTIM defect according the specification in EN 300 417-1-1 [3], subclause 8.2.1.Consequent Actions:aAIS¬CI_SSF or dTIM.aTSF¬CI_SSF or dTIM.On declaration of aAIS the function shall output an all-ONEs (AIS) signal within 250 ms; on clearing of aAIS thefunction shall output normal data within 250 ms.NOTE 1:The term "CI_SSF" has been added to the conditions for aAIS while the descrambler function has beenmoved from the e.g. OS1/RS1_A_Sk to this function. Consequently, an all-ONEs (AIS) pattern inserted inthe mentioned adaptation function would be descrambled in this function. A "refreshment" of all-ONEs isrequired.NOTE 2:The insertion of AIS - especially due to detection of dTIM - will cause the RS-DCC channel to be"squelched" too, so that control of the NE via this channel is lost. If control is via this channel only, thereis a risk of a dead-lock situation if dTIM is caused by a misprovisioning of ExTI.Defect Correlations:cTIM¬MON and dTIM.Performance Monitoring:For further study.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)184.3STM-1 Regenerator Section Adaptation functions4.3.1STM-1 Regenerator Section to Multiplex Section Adaptation SourceRS1/MS1_A_SoSymbol:RS1/MS1MS1_CIRS1_AIFigure 8: RS1/MS1_A_So symbolInterfaces:Table 3: RS1/MS1_A_So input and output signalsInput(s)Output(s)MS1_CI_DMS1_CI_CKMS1_CI_FSMS1_CI_SSFRS1_AI_DRS1_AI_CKRS1_AI_FSProcesses:The function multiplexes the MS1_CI data (2 403 bytes / frame) into the STM-1 byte locations defined inETS 300 147 [1] and depicted in figure 2.NOTE 1:There might be cases in which the network element knows that the timing reference for a particularSTM-1 interface can not be maintained within ±4,6 ppm. For such cases MS-AIS can be generated. Thisis network element specific and outside the scope of the present document.Defects:None.Consequent Actions:aAIS¬CI_SSF.On declaration of aAIS the function shall output all ONEs signal within 250 µs; on clearing of aAIS the function shalloutput normal data within 250 µs. The frequency of the all ONEs signal shall be within 155 520 kHz ± 20 ppm.NOTE 2:If CI_SSF is not connected (when RS1/MS1_A_So is connected to a MS1_TT_So), SSF is assumed to befalse.Defect Correlations:None.Performance Monitoring:None.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)194.3.2STM-1 Regenerator Section to Multiplex Section Adaptation SinkRS1/MS1_A_SkSymbol:RS1/MS1MS1_CIRS1_AIFigure 9: RS1/MS1_A_Sk symbolInterfaces:Table 4: RS1/MS1_A_Sk input and output signalsInput(s)Output(s)RS1_AI_DRS1_AI_CKRS1_AI_FSRS1_AI_TSFMS1_CI_DMS1_CI_CKMS1_CI_FSMS1_CI_SSFProcesses:The function separates MS1_CI data from RS1_AI as depicted in figure 2.Defects:None.Consequent Actions:aSSF¬AI_TSF.Defect Correlations:None.Performance Monitoring: None.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)204.3.3STM-1 Regenerator Section to DCC Adaptation SourceRS1/DCC_A_SoSymbol:RS1/DCCDCC_CI_DRS1_AISTM-1_TIDCC_CI_CKFigure 10: RS1/DCC_A_So symbolInterfaces:Table 5: RS1/DCC_A_So input and output signalsInput(s)Output(s)DCC_CI_DSTM1_TI_CKSTM1_TI_FSRS1_AI_DDCC_CI_CKProcesses:The function multiplexes the DCC CI data (192 kbit/s) into the byte locations D1, D2 and D3 as defined inETS 300 147 [1] and depicted in figure 3.NOTE:DCC transmission can be "disabled" when the matrix connection in the connected DCC_C function isremoved.Defects:None.Consequent Actions:None.Defect Correlations:None.Performance Monitoring:None.SIST EN 300 417-3-1 V1.1.3:2003

ETSIEN 300 417-3-1 V1.1.3 (1999-05)214.3.4STM-1 Regenerator Section to DCC Adaptation Sink
...