SIST EN 304:1997
(Main)Heating boilers - Test code for heating boilers for atomizing oil burners
Heating boilers - Test code for heating boilers for atomizing oil burners
The test code applies to the tests of the thermal performance of oil-fired heating boilers (hereafter called 'boilers') and combined boilers and water heaters. The requirements are laid down in EN 303 part 1 and EN 303 part 2. This standard includes the requirements and recommendations for carrying out and evaluating the procedure for testing boilers and also the details of the technical condtions under which the tests shall be carried out.
Heizkessel - Prüfregeln für Heizkessel mit Ölzerstäubungsbrennern
Die Prüfregeln gelten für die heiztechnische Prüfung von Heizkesseln für flüssige Brennstoffe (im folgende Kessel genannt) und für die Kombination Kessel/Wasserwärmer, für die in der Norm EN 303 Teil 1 und EN 303 Teil 2 Anforderungen festgelegt sind. Die Regeln enthalten Bestimmungen und Empfehlungen für die Durchführung und Auswertung der Versuche zur Prüfung der Kessel sowie Angaben über die technischen Bedingungen, unter denen die Versuche stattfinden sollen.
Chaudieres de chauffage - Regles d'essai pour les chaudieres pour bruleurs a fioul a pulvérisation
Les règles d'essai s'appliquent aux essais thermiques des chaudières de chauffage à combustible liquide (ci-après appelées chaudières) et aux combinaisons chaudière/chauffe-eau. La présente norme fixe des règles d'essais pour ces deux types de matériels correspondant aux exigences formulées dans les normes EN 303 partie 1 et EN 303 partie 2. Ces règles comprennent des préscriptions et des recommandations relatives à la conduite et à l'évaluation des essais pour la vérification des chaudières, ainsi que les données relatives aux conditions techniques dans lesquelles doivent se dérouler ces essais.
Kotli za gretje - Preskušanje kotlov z razprševalnimi oljnimi gorilniki
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-1997
Kotli za gretje - Preskušanje kotlov z razprševalnimi oljnimi gorilniki
Heating boilers - Test code for heating boilers for atomizing oil burners
Heizkessel - Prüfregeln für Heizkessel mit Ölzerstäubungsbrennern
Chaudieres de chauffage - Regles d'essai pour les chaudieres pour bruleurs a fioul a
pulvérisation
Ta slovenski standard je istoveten z: EN 304:1992
ICS:
91.140.10 Sistemi centralnega Central heating systems
ogrevanja
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies, the requirements and test methods concerning the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners and are hereafter referred to as “boilers”.
Where the word boiler is used, this is intended to be read as the boiler including its connecting ducts, ducts and terminals, if any.
This document covers gas-fired central heating boilers type B11, B11BS, B12, B12BS, B13, B13BS:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 70 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which are declared in the technical instructions to be either a “low temperature boiler” or a “standard boiler”. If no declaration is given the boiler is to be considered a “standard boiler”;
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle, as a single unit;
h) which are designed for either sealed water systems or for open water systems.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB);
ab) appliances using flue dampers;
ac) appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ad) appliances of the types A, B14, B¬2, B3, B4, B5 and C;
ae) appliances intended to be connected to a (common) flue having mechanical extraction;
af) appliances with gas/air ratio control;
ag) modular boilers;
ah) boilers which can give rise to condensation under certain circumstances;
ai) boilers intended to be installed in a room with a foreseeable negative pressure relative to the pressure in the flue system;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) boilers intended to be installed in areas accessible to elderly people and children;
am) boilers equipped with an adaptive combustion control function (ACCF).
NOTE Negative pressure relative to the pressure in the flue system can for example be caused by mechanical or thermal ventilation in airtight buildings.
- Standard55 pagesEnglish languagesale 10% offe-Library read for×1 day
Scope of CEN/TS 15502-3-1
EN 15502-2-1:2022, Clause 1 applies with the following modifications:
Add after k):
l) which are fully premixed appliances equipped with an Adaptive Combustion Control Function (ACCF) that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance including gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20).
m) which are fully premixed appliances equipped with a Pneumatic Gas Air Ratio controller (PGAR) that are intended to be connected to gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20), where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extent over the lifetime of the appliance.
Replace ab) and ak) and al) by the following:
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021), except for fully premixed appliances with a ACCF, as ACCF appliances are designed to adapt to variations in gas quality.
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas, except for fully premixed appliances with a ACCF or PGAR (which are covered by this document);
al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).
- Technical specification59 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”.
This European Standard is to be used in conjunction with the specific Parts 2 (Part 2-1 and following ones).
This European Standard applies to boilers of types B and C.
NOTE For further background information on appliance types see CEN/TR 1749:2014 [1].
a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
b) where the temperature of the water is below or above 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler";
NOTE The Ecodesign Directive defines "other boilers", "low temperature boilers" and "condensing boilers". The Boiler Efficiency Directive defines "standard boilers", "low temperature boilers" and "condensing boilers". Depending on the legislation applied, a boiler can be both "a standard boiler" and an "other boiler"."
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit.
This European Standard applies to boilers designed for sealed water systems or for open water systems.
NOTE This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This European Standard is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex EE).
This European Standard is not intended to cover appliances designed and constructed to burn gas containing toxic components.
- Standard213 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the requirements and test methods, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers".
This document is intended to be used in conjunction with EN 15502-1:2021.
This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which can give rise to condensation under certain circumstances;
f) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler";
g) which are intended to be installed inside a building or in a partially protected place;
h) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit;
i) which are designed for either sealed water systems or for open water systems;
j) which are either modular boilers, or non-modular boilers.
k) which are from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, and C(11) that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances above 1 000 kW;
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021);
ac) appliances using flue dampers;
ad) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81, C(12) and C(13);
ae) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
af) appliances incorporating flexible plastic flue liners;
ag) C(10) boilers:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ah) C(11) boilers that have boiler modules:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ai) appliances intended to be connected to a flue having mechanical extraction;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) appliances equipped with an adaptive combustion control function (ACCF);
am) boilers intended to be installed in areas accessible to elderly people and children.
- Standard105 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the requirements and tests methods concerning the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of hybrid units.
A hybrid unit is composed of:
- a gas boiler as a heat generator which is able to supply the heat demand in all operating conditions;
- an electrical air-to-water heat pump, as a heat generator, which does not have to meet the heat demand in all operating conditions;
- a control unit (see definition 3.1.10).
A hybrid unit can include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit.
A gas boiler as part of a hybrid unit covered by this document is a gas-fired central heating boiler from the types C1 up to C9 and the types B2, B3 and B5, according to the classification in EN 1749:2020:
a) that have a nominal heat input (on the basis of gross calorific value) not exceeding 400 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which are classified as a gas-fired central heating boiler;
f) which are intended to be installed either indoors or outdoors in a partially protected place;
g) which are designed for either sealed water systems or for open water systems.
This document provides requirements for boilers with known constructions.
NOTE 1 For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
NOTE 2 An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Regulation UE/426/2016, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see EN 15502-1:2021, Annex AB);
ab) appliances using flue dampers;
ac) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71 and C81;
ad) appliances incorporating flexible plastic flue liners;
ae) appliances designed to become connected to a combined flue duct system.
af) appliances of the types C(10),C(11), C(12) and C(13);
ag) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ah) appliances intended to be connected to a flue having mechanical extraction;
ai) surface temperatures of external parts particular to children and elderly people;
aj) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
ak) appliances equipped with an adaptive combustion control function (ACCF);
al) boilers intended to be installed in areas accessible to elderly people and children.
This document specifies minimum operating requirements which ensure that the products are fit for the use designated by the technical instructions when used for space heating and/or DHW production.
This document is intended to be used in conjunction with:
ba) the gas-fired boiler, the generic part EN 15502-1:2021 and specific parts FprEN 15502-2-1:2022 and FprEN 15502-2-2:2022;
bb) the electrical heat pump, EN 14511-4:2018, EN 378-1:2016+A1:2020, EN 378-2:2016 and EN 14825:2022;
bc) electrical safety, EN 60335-1:2012 , EN 60335-2-102:2016 and IEC 60335-2-40:2018;
bd) for domestic hot water production, EN 13203-5:2022.
- Standard42 pagesEnglish languagesale 10% offe-Library read for×1 day
1.1 General
This European Standard applies to heating boilers including safety devices up to a nominal heat output of 500 kW which are designed for the burning of solid fuels only and are operated according to the instructions of the boiler manufacturer.
This European Standard deals with significant hazards, hazardous situations and events relevant to heating boilers used as intended and under the conditions foreseen by the manufacturer (see Clause 4).
The boilers may operate under natural draught or forced draught. The stoking may work manually or automatically.
The boilers may operate under room sealed conditions in case of supervised under pressure in the combustion chamber.
The boilers may operate in condensing condition.
NOTE This European Standard deals with boilers which are both within and outside of the scope of the Machinery
Directive 2006/42/EC.
This European Standard contains requirements and test methods for safety, combustion quality, operating characteristics, marking and maintenance of heating boilers and secondary emission reduction appliances and efficiency improvement appliances. It also covers all external equipment that influences the safety systems (e.g. back burning safety device, integral fuel hopper).
This European Standard covers only boilers that include burners as a unit. The standard applies to the combination of a boiler body with a solid fuel burner according to EN 15270 as a unit only when the whole unit is tested in accordance with this European Standard.
Heating boilers in accordance with this European Standard are designed for central heating installations where the heat carrier is water and the maximum allowable temperature is 110 °C, and which can operate at a maximum allowable operating pressure of 6 bars. For heating boilers with a built-in or attached water heater (storage or continuous flow heater), this European Standard only applies to those parts of the water heater which are necessarily subject to the operating conditions of the heating boiler (heating part).
This European Standard does not apply to:
heating boilers and other heating appliances which are also designed for the direct heating of the place of installation;
cooking appliances;
the design and construction of external fuel storage and transportation devices prior to the safety devices of the boiler;
room sealed applications above a nominal heat output > 70 kW or operated with positive pressure in the combustion chamber or operated under natural draught;
This European Standard specifies the necessary terminology for solid fuel heating boilers, the control and safety related requirements, the design requirements, the technical heating requirements (taking into account the environmental requirements) and testing, as well as the marking requirements.
This European Standard is not applicable to heating boilers which are tested before the date of its publication as an EN (European Standard).
1.2 Fuels
These boilers may burn either fossil fuels, biogenic fuels or other fuels such as peat, as specified for their use by the boiler manufacturer, in accordance with the requirements of this European Standard.
Solid fuels included in this European Standard are categorised as follows.
1.2.1 Biogenic fuels
Biomass in a natural state, in the form of:
Adaptation to new fuels standards and consideration of new fuels standards in preparation.
A log wood with moisture content w ≤ 25 %, according to EN 14961-5;
B1 chipped wood (wood chipped by machine, usually up to a maximum length of 15 cm) with moisture content from w 15 % to w 35 %, according to EN 14961-4;
B2 chipped wood as under B1, except with moisture content w > 35 %;
C1 compressed wood (e.g. pellets without additives, made of wood and/or bark particles; natural binding agents such as molasses, vegetable paraffins and starch are permitted), pellets according to EN 14961-2;
(...)
- Standard103 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard is applicable to boilers used for central heating in accordance with prEN 303 1:2016 up to a nominal heat output of 1 000 kW and EN 303 4 up to a nominal heat output of 70 kW with forced draught burners in accordance with EN 267 that are designed for operating with liquid fuels.
The performance requirements of this standard apply to type testing to heating boilers (standard, low temperature and condensing boilers) which are tested on a test rig in accordance with the test code given in EN 304.
This standard applies also to room sealed boilers as defined in EN 15035 regarding efficiency and emissions.
This standard can also be used as the basis for evaluation of boiler-/burner units.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard applies to boilers used for central heating (heating boilers) with forced draught burners with a nominal heat output not exceeding 1 000 kW, which are operated either with negative pressure (natural draught boilers) or with positive pressure (pressurized boiler) in the combustion chamber, in accordance with the boiler instructions.
This European Standard specifies the necessary terminology, the requirements on the materials and testing of them, and marking requirements for heating boilers.
Particular requirements for boilers that can be used with open vented systems are contained in EN 303 4.
The requirements of this standard apply to heating boilers that are tested on an authorized test rig.
Boilers in accordance with this standard are designed for the heating of central heating installations in which the heat carrier is water, and the maximum allowable operating temperature of which is restricted to 100 °C. The maximum allowable operating pressure is 8 bar.
For boilers and water heaters (storage or continuous flow heater) this standard only applies to the parts which are necessarily subject to the operating conditions of the heating boiler (heating part).
This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, boilers with oil vaporization burners. For these boilers there are further requirements.
- Standard37 pagesEnglish languagesale 10% offe-Library read for×1 day
1.1 This European Standard applies to electrical or non electrical temperature control devices which are used to control temperatures within heat generating systems by controlling the supply of energy. It also applies to limiting devices which ensure that the temperature in heat generating systems will not exceed a predefined limit.
This European Standard specifies operating values, operating times, and operational sequences associated with the safety of the heat generating system.
This European Standard also applies to controls using NTCs or PTCs thermistors, additional requirements for which are contained in Annex J of EN 60730-2-9:2010.
This European Standard applies to controls with a rated voltage not exceeding 690 V and with a rated current not exceeding 63 A.
This European Standard also applies to manual controls if, electrically and/or mechanically, they form an integral part of automatic controls.
NOTE Requirements for manually operated switches not forming part of an automatic control are contained in EN 61058 1.
This European Standard does not apply to room thermostats.
1.2 This European Standard does not take into account the response value of an automatic action of the control, if such a response value is dependent upon the method of mounting the control in the heat generating system or equipment, in which case the control should be tested together with the heat generator. Where a response value is of significance for the protection of the user or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer applies.
1.3 This European Standard applies also to controls incorporating electronic devices, requirements for which are contained in Annex DX.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day