IEC 60050-411-am1
Amendment 1 - International Electrotechnical Vocabulary - Part 411: Rotating machinery
Amendment 1 - International Electrotechnical Vocabulary - Part 411: Rotating machinery
Amendement 1 - Vocabulaire Électrotechnique International - Partie 411: Machines tournantes
Mednarodni elektrotehniški slovar - 411. del: Rotacijski stroji - Dopolnilo A1
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2017
Mednarodni elektrotehniški slovar - 411. del: Rotacijski stroji - Dopolnilo A1
Amendment 1 - International Electrotechnical Vocabulary - Part 411: Rotating machinery
Amendement 1 - Vocabulaire Électrotechnique International - Partie 411: Machines
tournantes
Ta slovenski standard je istoveten z: IEC 60050-411-am1
ICS:
01.040.29 Elektrotehnika (Slovarji) Electrical engineering
(Vocabularies)
29.160.01 Rotacijski stroji na splošno Rotating machinery in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
IEC 60050-411
Edition 2.0 2007-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
International Electrotechnical Vocabulary – Part 411: Rotating machinery
Vocabulaire Electrotechnique International – Partie 411: Machines tournantes
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
R
CODE PRIX
ICS 01.040.29; 29.106.01 ISBN 2-8318-9369-0
60050-411 Amend. 1 © IEC:2007 – II –
AVANT-PROPOS
Le présent amendement a été établi par le comité d'études 1 de la CEI: Terminologie.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
1/2017/FDIS 1/2026/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de cet amendement et de la publication de base ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
_____________
INTRODUCTION
Le terme 411-48-09, couple d'accrochage (d'un moteur synchrone) a été annulé sans
remplacement. La raison en est que la synchronisation est un phénomène transitoire qui ne
peut être décrit par un terme bien défini et donc la définition existante n'a pas d'importance
pratique.
– III – 60050-411 Amend. 1 ©:2007
FOREWORD
This amendment has been prepared by IEC technical committee 1: Terminology.
The text of this amendment is based on the following documents:
FDIS Report on voting
1/2017/FDIS 1/2026/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
INTRODUCTION
The term 411-48-09 pull-in torque (of a synchronous motor) has been deleted with no
replacement. The reason was that the synchronization is a transient phenomenon which
cannot be described by a defined term and therefore the existing definition has no practical
importance.
– 1 – 60050-411 Amend. 1 ©:2007
SECTION 411-31 - GENERALITES
SECTION 411-31 – GENERAL
Page 3
411-31-11
machine à réluctance variable
inductor machine
Ce changement ne concerne que l’anglais.
Replace the title of the entry 411-31-11 by the following:
reluctance machine
de Reluktanzmaschine, f
SECTION 411-32 - GENERATRICES
SECTION 411-32 – GENERATORS
Page 6
411-32-05
excitatrice
exciter
Remplacer le titre et la définition de l'article 411-32-05 par ce qui suit :
Replace the title and the definition of the entry 411-32-05 by the following:
excitatrice
exciter
une source fournissant tout ou partie de la puissance à l'enroulement de champ d'une
machine électrique
a source that supplies all or part of the power to the field winding of an electrical machine
NOTE Les excitatrices peuvent être des machines à courant continu ou des machines à courant
alternatif avec redresseurs ou redresseurs secs. Les excitatrices font partie du système d'excitation.
NOTE Exciters may be direct current machines, alternating current machines with rectifiers, or static
solid-state rectifiers. Exciters form part of the excitation system.
de Erregereinrichtung, f
es excitatriz
it eccitatrice
pl wzbudnica
pt excitatriz
zh 励磁机
60050-411 Amend. 1 © IEC:2007 – 2 –
Remplacer les articles 411-32-06 à 411-32-07 par les articles suivants:
Replace the entries 411-32-06 to 411-32-07 by the following:
411-32-06
alternateur d'excitation principal
alternateur d'excitation de la (des) machine(s) électrique(s) principales(s)
main exciter generator
exciter generator of the principal electrical machine or machines
de Haupterregergenerator, m
es alternador de excitación principal
it eccitatrice principale
pl wzbudnica główna
pt alternador de excitação principal
zh 主励磁机
411-32-07
alternateur d'excitation pilote
alternateur d'excitation de la (des) machine(s) électrique(s) principales(s)
pilot exciter generator
exciter generator of another exciter
de Hilfserregergenerator, m
es alternador de excitación piloto
it eccitatrice pilota
pl podwzbudnica
pt alternador de excitação piloto
zh 副励磁机
SECTION 411-35 – MACHINES EMPLOYEES A DES FINS DE COMMANDE
SECTION 411-35 – MACHINES FOR CONTROL SYSTEMS
Page 21
Ajouter, après l’article 411-35-04, le nouvel article suivant:
Add, after entry 411-35-04, the following new entry:
411-35-05
moteur pas à pas
moteur, dont le rotor tourne par incréments discrets quand l'enroulement du stator est
alimenté de façon programmée
stepping motor
motor, the rotor of which rotates in discrete angular increments when its stator windings are
energized in a programmed manner
de Schrittmotor, m
es motor paso a paso
it motore passo-passo
pl silnik skokowy ; silnik krokowy
pt motor de passo
zh 步进电动机
– 3 – 60050-411 Amend. 1 ©:2007
SECTION 411-36 – TERMES QUALIFICATIFS
SECTION 411-36 – QUALIFYING TERMS
Page 25
Ajouter, après l’article 411-36-18, les nouveaux articles suivants:
Add, after entry 411-36-18, the following new entries:
411-36-19
tolérance
déviation permise entre la valeur déclarée d'une quantité et la valeur mesurée
tolerance
permitted deviation between the declared value of a quantity and the measured value
de Grenzabweichung, f; Toleranz, f
es tolerancia
it tolleranza
pl tolerancja
pt tolerância
zh 容差
411-36-20
essai d'apparition des décharges partielles
tension la plus faible à laquelle sont initiées les décharges partielles durant l'essai quand la
tension appliquée à l'objet testé est graduellement augmentée à partir d'une valeur plus faible
que celle à laquelle sont observées les décharges
NOTE Avec une tension appliquée sinusoidale, la tension d'apparition des décharges partielles est
définie comme la valeur efficace de la tension. Avec des tensions en impulsion, la tension d'apparition
est définie comme la valeur crête-crête de la tension.
partial discharge inception voltage
lowest voltage at which partial discharges are initiated in the test arrangement when the
voltage applied to the test object is gradually increased from a lower value at which no such
discharges are observed
NOTE With sinusoidal applied voltage, the partial discharge inception voltage is defined as the r.m.s.
value of the voltage. With impulse voltages, the partial discharge inception voltage is defined as the
peak-to-peak voltage.
de Teilentladungs-Einsetzspannung, f
es tensión de aparición de las descargas parciales
it tensione di inizio scarica parziale
pl napięcie wystąpienia wyładowań niezupełnych
pt tensão de inserção de descargas parciais
zh 局部放电起始电压
60050-411 Amend. 1 © IEC:2007 – 4 –
411-36-21
tension d'extinction des décharges partielles
tension à laquelle les décharges partielles disparaissent durant l'essai quand la tension
appliquée à l'objet testé est graduellement réduite à partir d'une valeur plus forte que celle à
laquelle sont observées les décharges
NOTE Avec une tension appliquée sinusoidale, la tension d'extinction des décharges partielles est
définie comme la valeur efficace de la tension. Avec des tensions en impulsion, la tension d'extinction
est définie comme la valeur crête-crête de la tension.
partial discharge extinction voltage
voltage at which partial discharges are extinguished in the test arrangement when the voltage
applied to the test object is gradually decreased from a higher value at which such discharges
are observed
NOTE With sinusoidal applied voltage, the partial discharge extinction voltage is defined as the r.m.s.
value of the voltage. With impulse voltages, the partial discharge extinction voltage is defined as the
peak-to-peak voltage.
de Teilentladungs-Löschspannung, f
es tensión de extinción de las descargas parciales
it tensione di estinzione scarica parziale
pl napięcie zaniku wyładowań niezupełnych
pt tensão de extinção de descargas parciais
zh 局部放电熄灭电压
SECTION 411-38 – CONSTITUTION DES ENROULEMENTS
SECTION 411-38 – CONSTRUCTION OF WINDINGS
Page 37
Remplacer les titres des articles 411-38-11 à 411-38-12 par les titres suivants:
Replace the titles of entries 411-38-11 to 411-38-12 by the following:
411-38-11
enroulement préformé
form-wound winding
de Wicklung aus Formspulen, f
es devanado preformado
it avvolgimento sagomato
pl uzwojenie z ukształtowanych zezwojów
pt enrolamento pré-formado
zh 成型绕组
411-38-12
enroulement partiellement préformé
partly form-wound winding
de Wicklung aus Teilformspulen, f
es devanado parcialmente preformado
it avvolgimento parzialmente sagomato
pl uzwojenie z częściowo ukształtowanych zezwojów
pt enrolamento parcialmente pré-formado
zh 部分成型绕组
– 5 – 60050-411 Amend. 1 ©:2007
SECTION 411-39 – ISOLATION
SECTION 411-39 – INSULATION
Page 49
Ajouter, après l’article 411-39-24, les nouveaux articles suivants:
Add, after entry 411-39-24, the following new entries:
411-39-25
système d'isolation
matière d'isolation, ou un ensemble de matières d'isolation à considérer en relation avec des
parties conductrices, appliquées à un type, ou taille ou partie spécifique d'un équipement
électrique
insulation system
insulating material, or an assembly of insulation materials, to be considered in relation with
associated conducting parts, as applied to a particular type or size or part of electrical equipment
de Isoliersystem, n
es sistema de aislamiento
it sistema di isolamento
pl układ izolacyjny
pt sistema de isolação
zh 绝缘结构
411-39-26
système d'isolation prototype
système d'isolation en essai pour déterminer son aptitude à satisfaire aux critères de
vieillissement (c'est à dire sa classe thermique)
candidate insulation system
insulation system being tested to determine its capability with respect to ageing factors (i.e.
its thermal class)
de Erprobungs-Isoliersystem, n
es sistema de aislamiento candidato
it sistema di isolamento prototipo
pl układ izolacyjny prototypowy
pt sistema de isolação protótipo
zh 待评绝缘结构
411-39-27
système d'isolation de référence
système d'isolation dont les caractéristiques ont été validées par un retour d'expérience
satisfaisant
reference insulation system
insulation system whose performance has been established by satisfactory service
experience
de Bezugs-Isoliersystem, n; Referenz-Isoliersystem, n
es sistema de aislamiento de referencia
it sistema di isolamento di riferimento
pl układ izolacyjny odniesienia
pt sistema de isolação de referência
zh 基准绝缘结构
60050-411 Amend. 1 © IEC:2007 – 6 –
SECTION 411-43 – STRUCTURE MECANIQUE, DISPOSITION DE MONTAGE,
SENS DE ROTATION
SECTION 411-43 – MECHANICAL STRUCTURE,
MOUNTING ARRANGEMENT, DIRECTION OF ROTATION
Page 70
411-43-05
Remplacer l’article 411-43-05 par l’article suivant:
Replace the entry 411-43-05 by the following:
arbre
partie du rotor qui supporte d'autres organes tournants et est supportée elle-même par des
paliers dans lesquels elle peut tourner
shaft
part of the machine which carries the rotating members and which is supported by bearings in
which it can rotate
de Welle, f
es eje
it albero
pl wał
pt árvore
zh 轴
SECTION 411-48 – GRANDEURS CARACTERISTIQUES
SECTION 411-48 – CHARACTERISTIC QUANTITIES
Page 91
411-48-09
couple d'accrochage (d'un moteur synchrone)
pull-in torque (of a synchronous motor)
Delete entry 411-48-09.
Page 99
Ajouter, après l’article 411-48-41, les nouveaux articles suivants:
Add, after entry 411-48-41, the following new entries:
411-48-42
couple minimal pendant le démarrage (d'un moteur à courant alternatif)
valeur la plus faible du couple asynchrone en régime établi que le moteur développe entre la
vitesse nulle et la vitesse qui correspond au couple de décrochage lorsque le moteur est
alimenté à la tension et à la fréquence assignées
NOTE 1 Cette définition ne s’applique pas aux machines asynchrones dont le couple diminue de
manière continue quand la vitesse augmente.
– 7 – 60050-411 Amend. 1 ©:2007
NOTE 2 En plus des couples asynchrones en régime établi, les couples synchrones harmoniques, qui
dépendent de l’angle de charge du rotor, seront présents à certaines vitesses
pull-up torque (of an a.c. motor)
smallest steady-state asynchronous torque which the motor develops between zero speed
and the speed which corresponds to the breakdown torque, when the motor is supplied at the
rated voltage and frequency
NOTE 1 This definition does not apply to those induction motors of which the torque continually
decreases with increase in speed.
NOTE 2 In addition to the steady-state asynchronous torques, harmonic synchronous torques, which
are a function of ro
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.