IEC 60364-6:2016/COR1:2017
(Corrigendum)Corrigendum 1 - Low voltage electrical installations - Part 6: Verification
Corrigendum 1 - Low voltage electrical installations - Part 6: Verification
Corrigendum 1 - Installations électriques à basse tension - Partie 6: Vérification
General Information
Relations
Standards Content (Sample)
IEC 2017
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60364-6 IEC 60364-6
Edition 2.0 2016-04 Édition 2.0 2016-04
LOW VOLTAGE ELECTRICAL INSTALLATIONS – INSTALLATIONS ÉLECTRIQUES À BASSE
TENSION –
Part 6: Verification
Partie 6: Vérification
...
This May Also Interest You
IEC 60364-4-44:2024 provides requirements for the safety of electrical installations in the event of voltage disturbances and electromagnetic disturbances generated for different specified reasons. The requirements of this document are not intended to apply to systems for distribution of energy to the public, or power generation and transmission for such systems (see the scope of IEC 60364-1) although such disturbances can be conducted into or between electrical installations via these supply systems. This third edition cancels and replaces the second edition published in 2007, Amendment 1:2015 and Amendment 2:2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the structure of the document has been updated in accordance with the ISO/IEC Directives, Part 2:2021: the terms, definitions and symbols have been regrouped under a new Subclause 440.3, the tables and figures have been renumbered;
b) Clause 443 has been amended to better introduce the DC SPD and to improve some of the wording.
- Standard116 pagesEnglish languagesale 15% off
IEC 60364-5-53:2019 Deals with general requirements for isolation, switching and control and with the requirements for selection and erection of the devices provided to fulfil such functions. This fourth edition cancels and replaces the third edition published in 2001, Amendment 1:2002 and Amendment 2:2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all clauses except 531 and 534;
b) introduction of a new Clause 537 Monitoring;
c) Clause 530 contains all normative references and all terms and definitions.
- Standard75 pagesEnglish languagesale 15% off
- Standard182 pagesEnglish languagesale 15% off
- Standard152 pagesEnglish and French languagesale 15% off
- Standard369 pagesEnglish and French languagesale 15% off
- Standard13 pagesEnglish and French languagesale 15% off
IEC 60364-5-52:2009 deals with the selection and erection of wiring systems. This third edition cancels and replaces the second edition, published in 2001, and constitutes a technical revision. The main changes with respect to the previous edition are as follows:
- Subclause 521.4 introduces minor changes with regard to busbar trunking systems and powertrack systems.
- Subclause 523.6 introduces minor changes with regard to the sizing of cables where harmonic currents are present.
- A new sublause 523.9 concerning single-core cables with a metallic covering has been introduced.
- Clause 525 introduces changes in the maximum value of voltage drop permitted between the origin of the consumer's installation and the equipment which should not be greater than that given in the relevant annex.
- Clause 526 introduces minor changes to electrical connections including additional exceptions for inspection of connections and additional notes.
- Clause 528 introduces additional requirements with regard to proximity of underground power and telecommunication cables.
- Clause 529 introduces minor changes to selection and erection of wiring systems in relation to maintainability, including cleaning. The contents of the corrigendum of February 2011 have been included in this copy.
- Standard177 pagesEnglish languagesale 15% off
- Standard171 pagesEnglish and French languagesale 15% off
IEC 60364-4-42:2024 applies to electrical installations with regard to measures for the protection of persons, livestock and property against:
• thermal effects, risk of combustion or degradation of materials, and risk of burns caused by electrical equipment,
• flames in case of a fire hazard being propagated from electrical installations to other fire compartments segregated by barriers which are in the vicinity, and
• the impairment of the safe functioning of electrical equipment, including safety services due to thermal effects.
This group safety publication (GSP) focusing on safety essential requirements is primarily intended to be used as a product safety standard for the installations mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for installations similar to those mentioned in the scope of this GSP, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.
One of the responsibilities of a TC is, wherever applicable, to make use of basic safety publications and/or group safety publications in the preparation of its publications
This fourth edition cancels and replaces the third edition published in 2010 and Amendment 1:2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the Scope now includes a new paragraph stating that IEC 60364-4-42 has become a group safety publication (GSP) following the Advisory Committee on Safety (ACOS) recommendation for approval of the group safety function "protection against thermal effects for any kind of low-voltage electrical installations" to TC 64; this GSP is primarily intended to be used as a product safety standard for the installations mentioned in the scope, but also to be used by TCs in the preparation of publications for installations similar to those mentioned in the scope of this GSP;
b) new terms and definitions have been added;
c) a new Subclause 421.6 regarding measures for preventing fires originating from the use of an electrical stove or cooker or hob has been added;
d) the previous Subclause 421.7 was expanded and moved to a new Clause 426: Additional protective measures against thermal effect for locations where consequences of fire are severe;
e) requirements for escape routes have been expanded and modified;
f) requirements for final circuits in BE2 locations have been expanded and modified;
g) requirements for locations with irreplaceable goods or with business critical facilities have been expanded and modified;
h) a new Clause 425 for protection against fire due to fault currents has been added;
i) a new Clause 427 for protection against assembly internal arc faults has been added
- Standard64 pagesEnglish and French languagesale 15% off
IEC 60364-7-706:2024 applies to:
• fixed equipment within conducting locations with restricted movement; and
• supplies to equipment used within conducting locations with restricted movement.
This third edition cancels and replaces the second edition published in 2005 and Amendment 1:2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The structure of clauses 706.41X has been updated following the structure of IEC 60364-4-41:2005 and IEC 60364-4-41:2005/AMD1:2017.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60364-7-716:2023 specifies requirements in electrical installations for the distribution of ELV DC power using balanced, information technology cables and accessories primarily designed for data transmission, as specified in terms of a category within the channels of ISO/IEC 11801-1 using power sourcing equipment in accordance with IEC 62368-3.
Requirements are included for the design, erection, and verification of telecommunications infrastructure for the purpose of both telecommunications and distribution of ELV DC power. In addition, requirements are included for use of existing telecommunications infrastructure for distribution of ELV DC power.
The power delivery systems include, but are not restricted to, the Power over Ethernet systems specified by IEEE 802.3.
This document does not apply to the use of cables and accessories within the core and access networks for example private branch exchange (PBX).
- Standard21 pagesEnglish and French languagesale 15% off
IEC 60364-4-43:2023 provides requirements for:
- protection of live conductors, PEN conductors, PEM conductors, and PEL conductors against the harmful effects caused by overcurrent;
- coordination of measures for protection against overcurrent.
This fourth edition cancels and replaces the third edition published in 2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the standard has been restructured, see Table 1 (Correspondence between IEC 60364‑4‑43:2008 and this document) below;
b) the measure "automatic disconnection of supply" has been designated as the preferred measure for protection against overcurrent;
c) all measures except the measure "automatic disconnection of supply" have been transferred into new normative annexes to indicate that these measures are usable in certain applications and under certain restricted conditions only (see Annex A, Annex B and Annex E);
d) a new clause "Terms and definitions" has been added;
e) new requirements have been added for the protection of the neutral or mid-point conductor (with and without triplen harmonics).
- Standard67 pagesEnglish and French languagesale 15% off
IEC 60364-5-57:2022 provides requirements and recommendations for the design, erection, correct use and protection of installations with secondary stationary batteries as prime storage medium, hereinafter referred to as "stationary secondary batteries".
This document is not applicable to products such as batteries and to systems design (including batteries) which are already covered by their own IEC standard.
- Standard50 pagesEnglish and French languagesale 15% off
IEC 60364-8-82:2022 provides requirements and recommendations that apply to low-voltage electrical installations connected or not to a distribution network able to operate:
– with local power supplies, and/or
– with local storage units,
and that monitors and controls the energy from the locally connected sources delivering it to:
– current-using equipment, and/or
– local storage units, and/or
– distribution networks.
Such electrical installations are designated as prosumer's electrical installations (PEIs).
These requirements and recommendations apply to new installations and modifications of existing installations.
This document also provides requirements and recommendations for the safe, efficient and correct behaviour of these installations when integrated into a smart grid.
Information related to grid interaction to ensure the stability of the electrical system for grid connected PEIs is given in Annex B.
This document covers the requirements related to stability of islanded and stand-alone PEIs.
This first edition cancels and replaces IEC 60364-8-2 published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to IEC 6036482:2018:
a) the vocabulary and concepts have been aligned as much as possible with those used by TC 8 and SC 8B, taking notably into account the IEC 62898 and IEC 62786 series, still respecting the installers mindset (installers being the first users of the IEC 60364 series and being used to only refer to the IEC 60364 series);
b) the type of system earthing and the change of type of system earthing (sequencing) when there is a change of mode of the prosuming installation, have been clarified;
c) the conditions of connection and disconnection from the DSO network have also been described, both from the safety point of view and the proper functioning point of view;
d) additional requirements have been introduced;
e) the figures have been updated;
f) a new normative Annex D on single dwelling or similar application islandable PEIs has been added;
g) the numbering has also been reviewed to follow the updated numbering system of the IEC 60364 series, in line with the IEC Directives and compatible with Parts 7.
- Standard146 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.