Amendment 1 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol

General Information

Status
Published
Publication Date
11-Dec-2006
Drafting Committee
WG 14 - TC 13/WG 14
Current Stage
PPUB - Publication issued
Start Date
12-Dec-2006
Completion Date
15-Feb-2007

Relations

Effective Date
05-Sep-2023

Overview

IEC 62056-46:2002/AMD1:2006 is an Amendment 1 to the IEC 62056-46 standard, addressing electricity metering data exchange for meter reading, tariff, and load control specifically at the data link layer using the HDLC (High-level Data Link Control) protocol. Published by the International Electrotechnical Commission (IEC), this amendment supports enhanced interoperability and communication efficiency in the exchange of metering data. The amendments reflect alignment with the third edition of ISO/IEC 13239 and update terminology, procedures, and referenced standards for improved clarity and precision.

Key Topics

  • HDLC Protocol Enhancements: Incorporates frame type 3 (per ISO/IEC 13239) for data link layer communications, providing greater flexibility in the handling of electricity metering data.
  • Addressing Schemes: Clarifies that secondary stations in the network may use more than one addressing scheme to support diverse topologies and devices.
  • Parameter Negotiation: Updates the negotiation procedure for maximum information field length, allowing for improved data exchange efficiency between primary and secondary stations.
  • Terminology Corrections: Standardizes nomenclature, such as consistent usage of “User_Information” and clear definitions of parameters like Destination_MSAP and Source_MSAP.
  • Reference Updates: Cites latest related documents, ensuring compatibility with IEC 62051-1 (Glossary), IEC 62056-53 (COSEM Application Layer), IEC 62056-61 (OBIS Object Identification), IEC 62056-62 (Interface Classes), and ISO/IEC 13239.
  • Editorial Refinements: Rectifies minor inconsistencies and clarifies technical descriptions for implementers.

Applications

IEC 62056-46:2002/AMD1:2006 is widely adopted in the following areas:

  • Smart Metering Systems: Facilitates secure, reliable, and efficient two-way data communication for remote meter reading, tariff management, and load control via standardized HDLC protocol procedures.
  • Interoperability Solutions: Enhances compatibility between metering equipment from various vendors, supporting multi-vendor deployments in smart grid infrastructures.
  • Utility Data Management: Supports automated and manual data collection strategies for metering data, ensuring accurate billing, load profiling, and demand analysis.
  • Networked Metering Environments: Provides essential guidance for data exchange in advanced metering infrastructure (AMI) and supervisory control scenarios.

The standard is especially relevant to electricity utilities, smart metering solution providers, device manufacturers, and system integrators working on digital transformation and automation in energy management.

Related Standards

  • IEC 62056 Series: Comprehensive suite for data exchange in metering, notably:
    • IEC 62056-53: Defines the COSEM application layer for metering.
    • IEC 62056-61: Specifies the OBIS coding system for object identification.
    • IEC 62056-62: Details interface classes for metering devices.
    • IEC 62051-1: Glossary of terms for consistent terminology.
  • ISO/IEC 13239: Governs HDLC procedures essential for compliant data exchange.
  • IEC 60050-300 and IEC 62051: References for definitions and terminology in electrical energy measurement.

By adhering to this standard and its amendment, organizations promote standardized, efficient, and reliable electricity metering data exchange, supporting global smart grid and utility modernization initiatives.

Buy Documents

Standard

IEC 62056-46:2002/AMD1:2006 - Amendment 1 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol Released:12/12/2006

ISBN:2-8318-8937-5
English language (8 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

IEC 62056-46:2002/AMD1:2006 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Amendment 1 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol". This standard covers: Amendment 1 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol

Amendment 1 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol

IEC 62056-46:2002/AMD1:2006 is classified under the following ICS (International Classification for Standards) categories: 35.100.20 - Data link layer; 91.140.50 - Electricity supply systems. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 62056-46:2002/AMD1:2006 has the following relationships with other standards: It is inter standard links to IEC 62056-46:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 62056-46:2002/AMD1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


INTERNATIONAL IEC
STANDARD 62056-46
AMENDMENT 1
2006-12
Amendment 1
Electricity metering –
Data exchange for meter reading,
tariff and load control –
Part 46:
Data link layer using HDLC protocol
© IEC 2006 Droits de reproduction réservés ⎯ Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale H

International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

– 2 – 62056-46 Amend. 1 © IEC:2006(E)
FOREWORD
This amendment has been prepared by IEC technical committee 13: Equipment for electrical
energy measurement and load control.
The text of this amendment is based on the following documents:
CDV Report on voting
13/1376/FDIS 13/1401/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
INTRODUCTION
This Amendment takes into account that in the third edition of ISO/IEC 13239, frame type 3
has been added as Annex H.4, as requested by IEC TC 13 WG 14, and that second editions
of some parts of the IEC 62056 series are under preparation.
It specifies now that a secondary station may use more than one addressing scheme.
It contains some changes concerning the negotiation of the maximum information length field
HDLC parameter for better efficiency.
References have been updated and some editorial errors have also been corrected.
Page 6
2 Normative references
Add the following reference:
IEC 62051-1:2004, Electricity metering – Data exchange for meter reading, tariff and load
control – Glossary of Terms – Part 1, Terms related to data exchange with metering
equipment using DLMS/COSEM
62056-46 Amend. 1 © IEC:2006(E) – 3 –
Amend the following references:
IEC 62056-53:2006, Electricity metering – Data exchange for meter reading, tariff and load
control – Part 53: COSEM Application layer
IEC 62056-61:2006, Electricity metering – Data exchange for meter reading, tariff and load
control – Part 61: OBIS Object identification system
IEC 62056-62:2006, Electricity metering – Data exchange for meter reading, tariff and load
control – Part 62: Interface classes
ISO/IEC 13239:2002, Information technology – Telecommunications and information
exchange between systems – High-level data link control (HDLC) procedures

Page 7
3 Terms, definitions and abbreviations
Replace the sentence by the following:
For the purposes of this document, the definitions given in IEC 60050-300, IEC 62051 and
IEC 62051-1 apply.
Page 8
4.3 Specification method
Delete, on page 9,in the fourth bullet point “(e.g. Physical_Connection_Type)”.
Add a line break, below the Note, before the second sentence “The protocol specification….”
so that this sentence belongs to the three bullet points following.
Replace, in the ninth bullet point ”(User data subfield)” by ”(Information field, User data
subfield)”.
Page 14
5.2.2.2 DL-DISCONNECT.request
Replace, in the service primitive definition ”User information” by ”User_Information”.
Replace, in the paragraph following the service primitive definition, ”User_information” by
”User_Information”.
5.2.2.3 DL-DISCONNECT.indication
Replace, in the service primitive definition, ”User Information” by ”User_Information”.
Replace, on page 15, in the paragraph above ”Use”, ”User Information” by “User_Information”.
5.2.2.4 DL-DISCONNECT.response
Replace, on page 15, in the paragraph following the service primitive definition,

– 4 – 62056-46 Amend. 1 © IEC:2006(E)
”The Destination_MSAP and Source_MSAP parameters specify the local and remote…”
by
”The Destination_MSAP and Source_MSAP parameters specify the remote and local…”

Page 17
DL-DATA.request
Replace, on page 18, in the first paragraph,
“The Source_LSAP and Destination_LSAP parameters specify the referenced data link…”
by
“The Destination_LSAP and Source_LSAP parameters specify the referenced data link…”
Replace, in the second paragraph,
“The Source_MSAP and Destination_MSAP parameters specify the local and remote…”
by
“The Destination_MSAP and Source_MSAP parameters specify the remote and local …”
Page 18
5.2.3.3 DL-DATA.indication
Replace, in the last paragraph on page 18,
“The Source_LSAP and Destination_LSAP parameters specify the referenced data link…”
by
“The Destination_LSAP and Source_LSAP parameters specify the referenced data link…”
Replace, on page 19, in the first paragraph,
“The Source_MSAP and Destination_MSAP parameters specify the local and remote…”
by
“The Destination_MSAP and Source_MSAP parameters specify the local and remote…”

62056-46 Amend. 1 © IEC:2006(E) – 5 –
Page 19
5.2.3.4 DL-DATA.confirm
Replace, in the second paragraph following the
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...