IEC 61754-7:2004
(Main)Fibre optic connector interfaces - Part 7: Type MPO connector family
Fibre optic connector interfaces - Part 7: Type MPO connector family
Defines the standard interface dimensions for type MPO family of connectors.
Interfaces de connecteurs pour fibres optiques - Partie 7: Famille de connecteurs de type MPO
Définit les dimensions d'interface normalisées pour la famille de connecteurs de type MPO.
General Information
- Status
- Published
- Publication Date
- 28-Nov-2004
- Technical Committee
- SC 86B - Fibre optic interconnecting devices and passive components
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 27-Mar-2008
- Completion Date
- 26-Oct-2025
Relations
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
Overview
IEC 61754-7:2004 is an international standard published by the International Electrotechnical Commission (IEC) that defines the interface dimensions for the Type MPO (Multi-fiber Push On) family of fibre optic connectors. This standard ensures uniformity and interchangeability of MPO connectors, which play a critical role in high-density fibre optic network systems.
MPO connectors are widely used in telecommunications, data centers, and networking environments where multi-fiber connections are essential. By standardizing the dimensions and interface requirements, IEC 61754-7 facilitates compatibility across manufacturers, improving connectivity reliability and system performance.
Key Topics
- Scope: The standard specifies mechanical interface dimensions for the MPO connector family, including male and female plug connectors, adaptors, and backplane and printed circuit board (PCB) housings.
- Interface Types: Both angled and flat interface configurations are detailed for MPO connectors. This includes specific design parameters relevant to optical alignment and mechanical fit.
- Dimensional Specifications: Precise measurements for connector components such as gauge pins, plugs, and adaptors are provided to ensure consistent mating performance.
- Mechanical Compatibility: Defines interfaces for MPO components used in various applications, including chassis backplanes and PCB connectors.
- Optical Datum Targets: Locations for optical datum points are specified to guarantee proper fiber alignment within connectors.
IEC 61754-7 includes comprehensive figures and tables with detailed dimensional data to guide manufacturers and engineers in designing MPO-compatible components.
Applications
- Telecommunications Infrastructure: MPO connectors standardized by IEC 61754-7 are commonly used to support high-density fiber optic cabling in telephone exchanges and broadband networks.
- Data Centers: The MPO family facilitates scalable multi-fiber connections required for optical distribution frames, enabling efficient data transmission in data center environments.
- High-Speed Networking: MPO connectors support parallel optic technologies, enabling multi-channel transmission for Ethernet, Fibre Channel, and InfiniBand networks.
- Optical Cross-Connect Systems: The standard ensures MPO connectors operate reliably as part of modular optical switching and routing platforms.
- Backplane and PCB Integration: The standard covers connectors designed for direct mounting to electronic assemblies, supporting integrated optical interconnect solutions.
Related Standards
- IEC 61754 Series: Covers various fibre optic connector interface standards for different connector types to ensure broad interoperability.
- IEC 60793: Specifies optical fibre characteristics that complement connector interface standards.
- ISO/IEC 11801: Specifies generic cabling for customer premises that often incorporates IEC-standardized connectors including MPO.
- TIA-604-5 (FOCIS 5): An industry standard related to MPO connectors addressing similar interface and performance criteria.
- IEC 61300 Series: Provides test procedures for fibre optic interconnecting devices and passive components, useful to confirm compliance to IEC 61754-7.
Keywords: IEC 61754-7, MPO connector, fibre optic connector, connector interface dimensions, multi-fiber push on, fibre optic standards, high-density connectivity, optical datum, MPO adaptor, fibre optic cabling standard.
Frequently Asked Questions
IEC 61754-7:2004 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Fibre optic connector interfaces - Part 7: Type MPO connector family". This standard covers: Defines the standard interface dimensions for type MPO family of connectors.
Defines the standard interface dimensions for type MPO family of connectors.
IEC 61754-7:2004 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61754-7:2004 has the following relationships with other standards: It is inter standard links to IEC 61754-7:1996/AMD2:2000, IEC 61754-7:1996/AMD1:1999, IEC 61754-7:2008, IEC 61754-7:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61754-7:2004 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
61754-7
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2004-11
Interfaces de connecteurs
pour fibres optiques –
Partie 7:
Famille de connecteurs de type MPO
Fibre optic connector interfaces –
Part 7:
Type MPO connector family
Numéro de référence
Reference number
CEI/IEC 61754-7:2004
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
61754-7
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2004-11
Interfaces de connecteurs
pour fibres optiques –
Partie 7:
Famille de connecteurs de type MPO
Fibre optic connector interfaces –
Part 7:
Type MPO connector family
IEC 2004 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
U
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61754-7 CEI:2004
SOMMAIRE
AVANT-PROPOS .3
1 Domaine d’application.8
2 Description.8
3 Interfaces.8
Figure 1 – Configurations de connecteur MPO.10
Figure 2a – Interface angulaire pour connecteur MPO à fiche femelle .12
Figure 2b – Diagrammes d’emplacement de la cible de référence optique.16
Figure 2c – Broche étalon .20
Figure 2d – Etalon pour la fiche.22
Figure 3 – Interface angulaire pour connecteur MPO à fiche mâle.24
Figure 4 – Interface pour adaptateur MPO .28
Figure 5 – Interface plate pour connecteur MPO à fiche femelle.32
Figure 6 – Interface plate pour connecteur MPO à fiche mâle .36
Figure 7 – Interface pour support de fond de panier MPO .40
Figure 8 – Interface pour support de carte imprimée MPO .46
Tableau 1a – Dimensions de l’interface angulaire pour connecteur MPO à fiche femelle .14
Tableau 1b – Dimensions de la broche étalon.20
Tableau 1c – Dimensions de l’étalon pour la fiche .22
Tableau 2 – Dimensions de l’interface angulaire pour connecteur MPO à fiche mâle.26
Tableau 3 − Dimensions de l’interface pour adaptateur MPO .30
Tableau 4 – Dimensions de l’interface plate pour connecteur MPO à fiche femelle.34
Tableau 5 – Dimensions de l’interface plate pour connecteur MPO à fiche mâle.38
Tableau 6a – Dimensions du support de fond de panier MPO .44
Tableau 6b – Variante .46
Tableau 7 – Dimensions de l’interface pour support de carte imprimée MPO.50
61754-7 IEC:2004 – 3 –
CONTENTS
FOREWORD.3
1 Scope.9
2 Description.9
3 Interfaces.9
Figure 1 – MPO connector configurations .11
Figure 2a – MPO female plug connector angled interface .13
Figure 2b – Optical datum target location diagrams .17
Figure 2c – Gauge pin.21
Figure 2d – Gauge for plug.23
Figure 3 – MPO male plug connector angled interface .25
Figure 4 – MPO adaptor interface.29
Figure 5 – MPO female plug connector flat interface.33
Figure 6 – MPO male plug connector flat interface.37
Figure 7 – MPO backplane housing interface.41
Figure 8 – MPO printed board housing interface .47
Table 1a – Dimensions of the MPO female plug connector angled interface .15
Table 1b – Dimensions of the gauge pin .21
Table 1c – Dimensions of the gauge for plug .23
Table 2 – Dimensions of the MPO male plug connector angled interface.27
Table 3 – Dimensions of the MPO adaptor interface .31
Table 4 – Dimensions of the MPO female plug connector flat interface .35
Table 5 – Dimensions of the MPO male plug connector flat interface .39
Table 6a – Dimensions of the MPO backplane housing.45
Table 6b – Grade .47
Table 7 – Dimensions of the MPO printed board housing interface.51
– 4 – 61754-7 CEI:2004
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
___________
INTERFACES DE CONNECTEURS POUR FIBRES OPTIQUES –
Partie 7: Famille de connecteurs de type MPO
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des comités d'études,
aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux
travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable de
l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
La Commission Electrotechnique Internationale (CEI) attire l'attention sur le fait qu'il est déclaré que la conformité
avec les dispositions du présent document peut impliquer l'utilisation d'un brevet intéressant les connecteurs de
type MPO.
La CEI ne prend pas position quant à la preuve, à la validité et à la portée de ces droits de propriété.
Le détenteur de ces droits de propriété a donné l’assurance à la CEI qu'il consent à négocier des licences avec des
demandeurs du monde entier, à des termes et conditions raisonnables et non discriminatoires. À ce propos, la
déclaration du détenteur des droits de propriété est enregistrée auprès de la CEI. Des informations peuvent être
demandées à:
Intellectual Property Department,
Nippon Telegraph and Telephone Corporation,
20-2 Nishi-shinjuku 3-Chome Shinjukuku,
Tokyo 163-14, Japan.
L’attention est d’autre part attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété autres de ceux qui ont été mentionnés ci-dessus. La CEI ne saurait être tenue pour responsable
de l’identification de ces droits de propriété en tout ou partie.
La Norme internationale CEI 61754-7 a été établie par le sous-comité 86B: Dispositifs
d'interconnexion et composants passifs à fibres optiques, du comité d'études 86 de la CEI:
Fibres optiques.
61754-7 IEC:2004 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
FIBRE OPTIC CONNECTOR INTERFACES –
Part 7: Type MPO connector family
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that compliance
with this document may involve the use of a patent concerning MPO connectors.
The IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he/she is willing to negotiate licences under reasonable and
non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the
holder of this patent right is registered with the IEC. Information may be obtained from:
Intellectual Property Department,
Nippon Telegraph and Telephone Corporation,
20-2 Nishi-shinjuku 3-Chome Shinjukuku,
Tokyo 163-14, Japan.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights
other than those identified above. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61754-7 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
– 6 – 61754-7 CEI:2004
Cette deuxième édition annule et remplace la première édition parue en 1996, l’Amendement 1
(1999) et l’Amendement 2 (2000). Cette deuxième édition constitue une révision technique.
Les changements techniques spécifiques incluent un accroissement du nombre total de fibres:
de 12 fibres dans la première édition à 16 fibres, 20 fibres et 24 fibres.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
86B/2018/FDIS 86B/2039/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
La CEI 61754 comprend plusieurs parties, publiées sous le titre général Interfaces de
connecteurs pour fibres optiques
– La première partie, intitulée Généralités et guide, couvre les informations générales.
– Les parties suivantes concernent les interfaces pour diverses familles de connecteurs.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous "http://webstore.iec.ch" dans les données
relatives à la publication recherchée. A cette date, la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
61754-7 IEC:2004 – 7 –
This second edition cancels and replaces the first edition published in 1996, Amendment 1
(1999) and Amendment 2 (2000). This second edition constitutes a technical revision.
Specific technical changes involve increased fibre counts: up from 12 fibres in the previous
edition to 16 fibres, 20 fibres and 24 fibres.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/2018/FDIS 86B/2039/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
IEC 61754 consists of multiple parts, under the general title Fibre optic connector interfaces:
– Part 1, entitled General and guidance, covers general information.
– Subsequent parts contain interfaces for various connector families
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 8 – 61754-7 CEI:2004
INTERFACES DE CONNECTEURS POUR FIBRES OPTIQUES –
Partie 7: Famille de connecteurs de type MPO
1 Domaine d’application
La présente partie de la CEI 61754 définit les dimensions d’interface normalisées pour la
famille de connecteurs de type MPO
2 Description
Le connecteur à la base de la famille de connecteurs de type MPO est un connecteur à fiches
multicontacts caractérisé par une ferrule rectangulaire normalement de 6,4 mm × 2,5 mm utilisant
deux broches de 0,7 mm de diamètre pour son alignement. Il est applicable de raccorder des
fibres multiples, jusqu’à 12 fibres, en les groupant entre les deux trous de positionnement de
broche à l’intérieur de la ferrule. Il est en outre capable de raccorder jusqu’à 24 fibres en les
groupant sur deux couches. Le connecteur comporte un mécanisme de couplage de type
«pousser-tirer» et une férule comprimée par un ressort dans la direction de l’axe optique. Le
connecteur possède une clavette mâle unique qui peut être utilisée pour orienter et pour limiter la
position relative entre le connecteur et le composant auquel il est accouplé.
Les interfaces du connecteur sont configurées en utilisant une fiche femelle sans broches, une
fiche mâle à broches fixées et un adaptateur comme illustré à la Figure 1. La fiche femelle est
accouplable avec la fiche mâle.
De plus, les interfaces du connecteur entre la fiche femelle et la fiche mâle sont configurées en
utilisant un support de fond de panier et un support de carte imprimée à la place de
l’adaptateur.
3 Interfaces
La présente norme contient les interfaces normalisées suivantes:
Interface 7-1: Interface angulaire de type «pousser-tirer» pour connecteur MPO à fiche
femelle composée de:
Interface 7-1-1 pour 2 à 12 fibres
Interface 7-1-2 pour 16 à 24 fibres
Interface 7-2: Interface angulaire de type «pousser-tirer» pour connecteur MPO à fiche mâle
composée de:
Interface 7-2-1 pour 2 à 12 fibres
Interface 7-2-2 pour 16 à 24 fibres
Interface 7-3: Interface de type «pousser-tirer» pour adaptateur MPO
Interface 7-4: Interface plate de type «pousser-tirer» pour connecteur MPO à fiche femelle
composée de:
Interface 7-4-1 pour 2 à 12 fibres
Interface 7-4-2 pour 16 à 24 fibres
Interface 7-5: Interface plate de type «pousser-tirer» pour connecteur à fiche mâle MPO
composée de:
Interface 7-5-1 pour 2 à 12 fibres
Interface 7-5-2 pour 16 à 24 fibres
Interface 7-6: Interface «auto-retenue» pour support de fond de panier MPO
Interface 7-7: Interface «auto-retenue» pour support de carte imprimée MPO
61754-7 IEC:2004 – 9 –
FIBRE OPTIC CONNECTOR INTERFACES –
Part 7: Type MPO connector family
1 Scope
This part of IEC 61754 defines the standard interface dimensions for type MPO family of
connectors.
2 Description
The parent connector for type MPO connector family is a multiway plug connector charac-
terized by a rectangular ferrule normally 6,4 mm × 2,5 mm which utilizes two pins of 0,7 mm
diameter as its alignment. It is applicable to a joint of multiple fibres up to 12 fibres by arraying
them between two pin-positioning holes in the ferrule. Furthermore, it is capable of joining up to
24 fibres by arraying them with a two layer arrangement. The connector includes a push-pull
coupling mechanism and a ferrule spring loaded in the direction of the optical axis. The
connector has a single male key which may be used to orient and limit the relative position
between the connector and the component to which it is mated.
Connector interfaces are configured using a female plug without pins, a male plug with pins
fixed and an adaptor as shown in Figure 1. The female plug is intermateable with the male plug.
Moreover, connector interfaces between the female plug and the male plug are configured by
applying a backplane housing and a printed board housing instead of the adaptor.
3 Interfaces
This standard contains the following standard interfaces.
Interface 7-1: MPO female plug connector angled interface – Push/pull consisting of:
Interface 7-1-1 for 2 to 12 fibres
Interface 7-1-2 for 16 to 24 fibres
Interface 7-2: MPO male plug connector angled interface – Push/pull consisting of:
Interface 7-2-1 for 2 to 12 fibres
Interface 7-2-2 for 16 to 24 fibres
Interface 7-3: MPO adaptor interface – Push/pull
Interface 7-4: MPO female plug connector flat interface – Push/pull consisting of:
Interface 7-4-1 for 2 to 12 fibres
Interface 7-4-2 for 16 to 24 fibres
Interface 7-5: MPO male plug connector flat interface – Push/pull consisting of:
Interface 7-5-1 for 2 to 12 fibres
Interface 7-5-2 for 16 to 24 fibres
Interface 7-6: MPO backplane housing interface – Self-retaining
Interface 7-7: MPO printed board housing interface – Self-retaining
– 10 – 61754-7 CEI:2004
Les normes suivantes sont accouplables:
Fiches femelles Adaptateurs/supports Fiches mâles
7-1-1 7-3 7-2-1
7-1-2 7-3 7-2-2
7-4-1 7-3 7-5-1
7-4-2 7-3 7-5-2
7-1-1 7-6 et 7-7 7-2-1
7-1-2 7-6 et 7-7 7-2-2
7-4-1 7-6 et 7-7 7-5-1
7-4-2 7-6 et 7-7 7-5-2
NOTE Les interfaces pour connecteur entre 2 et 12 fibres seront accouplables et aligneront correctement les
nombres les plus faibles de cibles de références optiques définis. Les interfaces pour connecteur entre 16 et 24
fibres également seront accouplables et aligneront correctement les nombres les plus faibles de cibles de
références optiques définis.
Fiche femelle Adaptateur
Fiche mâle
Support
Support
de carte
de fond
imprimée
de panier
IEC 1065/2000
Figure 1 – Configurations de connecteur MPO
61754-7 IEC:2004 – 11 –
The following standards are intermateable:
Female plugs Adaptors/housings Male plugs
7-1-1 7-3 7-2-1
7-1-2 7-3 7-2-2
7-4-1 7-3 7-5-1
7-4-2 7-3 7-5-2
7-1-1 7-6 and 7-7 7-2-1
7-1-2 7-6 and 7-7 7-2-2
7-4-1 7-6 and 7-7 7-5-1
7-4-2 7-6 and 7-7 7-5-2
NOTE Connector interfaces among 2 to 12 fibres will intermate and will correctly align the lower defined numbers
of optical datum targets. Also connector interfaces among 16 to 24 fibres will intermate and will correctly align the
lower defined numbers of optical datum targets
Female plug Adaptor
Male plug
Printed
Backplane
board
housing
housing
IEC 1065/2000
Figure 1 – MPO connector configurations
– 12 – 61754-7 CEI:2004
∅
Trous de broches
Manchon
Voir Figure 2b
d’accouplement
IEC 1593/04
Figure 2a – Interface angulaire pour connecteur MPO à fiche femelle
∅A
∅E
∅F
∅G
∅H
61754-7 IEC:2004 – 13 –
∅
Pin-holes
Coupling sleeve
See Figure 2b
IEC 1593/04
Figure 2a – MPO female plug connector angled interface
∅A
∅E
∅F
∅G
∅H
– 14 – 61754-7 CEI:2004
Tableau 1a – Dimensions de l’interface angulaire pour connecteur MPO à fiche femelle
Référence Dimensions Notes
Minimale Maximale
A 0,699 mm 0,701 mm 1
C
4 597 mm 4,603 mm 2
D 6,3 mm 6,5 mm
E 8,34 mm 8,54 mm
F 9,49 mm 9,59 mm
G 10,85 mm 11,05 mm
H 12,19 mm 12,59 mm
I 8,8 mm 9,2 mm 3
J 7,9 mm 8,1 mm
K 1,4 mm –
L 0,2 mm 0,8 mm 4 et 5
M 2,4 mm 2,6 mm
N 2,8 mm 3,0 mm
O 4,89 mm 4,99 mm
P 5,59 mm 5,69 mm
Q 5,7 mm –
R – 7,7 mm
S 2,9 mm 3,1 mm
T – 0,8 mm
U 2,4 mm 2,5 mm
AA 42° 45°
AB – 45°
AC – 45°
AD 7,5° 8,5°
NOTE 1 Il faut que chaque trou de broche accepte une broche étalon conformément à la Figure 2c à une
profondeur de 5,5 mm avec une force maximale de 1,7 N. De plus, il faut que les deux trous de broches d’une fiche
acceptent une broche étalon conformément à la Figure 2d à une profondeur de 5,5 mm avec une force maximale de
3,4 N.
NOTE 2 La dimension C est définie comme la distance entre les centres des deux trous de broches.
NOTE 3 La dimension I est donnée pour le centre de la face terminale d’une fibre pour l’extrémité d’une fiche non
accouplée. On peut noter qu’une ferrule peut être déplacée par application d’une certaine force de compression
axiale, et ainsi la dimension I est variable. Il faut que la force de compression de la ferrule soit comprise entre 7,8 N
et 11,8 N lorsqu’une position de la face terminale de la fibre à partir de la référence Z est dans la plage de 8,2 mm à
8,4 mm.
NOTE 4 Il faut que le manchon de couplage puisse être déplacé en appliquant une certaine force de compression
axiale. La dimension L est donnée pour l’extrémité d’un manchon de couplage non accouplé. Il faut que la force de
compression du manchon de couplage soit comprise entre 2,9 N et 6,9 N lorsqu’une position de la face terminale du
manchon de couplage à partir de la référence Z est dans la plage de 0 mm à 0,1 mm de part et d’autre de la
référence Z.
NOTE 5 Il faut qu’une partie du couplage de l’adaptateur soit déverrouillée par un mouvement vers la gauche du
manchon de couplage, lorsqu’il est séparé de l’adaptateur. Lorsque le manchon de couplage est déplacé pour
déverrouillage, il faut que une position de la face terminale du manchon de couplage soit supérieure à 2,0 mm vers
la gauche par rapport à la référence Z.
61754-7 IEC:2004 – 15 –
Table 1a – Dimensions of the MPO female plug connector angled interface
Dimensions
Reference Notes
Minimum Maximum
A 0,699 mm 0,701 mm 1
C
4,597 mm 4,603 mm 2
D 6,3 mm 6,5 mm
E 8,34 mm 8,54 mm
F 9,49 mm 9,59 mm
G 10,85 mm 11,05 mm
H 12,19 mm 12,59 mm
I 8,8 mm 9,2 mm 3
J 7,9 mm 8,1 mm
K 1,4 mm –
L 0,2 mm 0,8 mm 4 and 5
M 2,4 mm 2,6 mm
N 2,8 mm 3,0 mm
O 4,89 mm 4,99 mm
P 5,59 mm 5,69 mm
Q 5,7 mm –
R – 7,7 mm
S 2,9 mm 3,1 mm
T – 0,8 mm
U 2,4 mm 2,5 mm
AA 42° 45°
AB – 45°
AC – 45°
AD 7,5° 8,5°
NOTE 1 Each pin-hole must accept a gauge pin as shown in Figure 2c to a depth of 5,5 mm with a maximum force
of 1,7 N. In addition, two pin-holes of a plug must accept a gauge as shown in Figure 2d to a depth of 5,5 mm with a
maximum force of 3,4 N.
NOTE 2 Dimension C is defined as the distance between two pin-hole centres.
NOTE 3 Dimension I is given for a fibre endface centre of a plug end when not mated. It is noticed that a ferrule is
movable by a certain axial compression force, and therefore the dimension I is variable. Ferrule compression force
must be 7,8 N to 11,8 N when a position of the fibre endface from the datum Z is in the range of 8,2 mm to 8,4 mm.
NOTE 4 Coupling sleeve must be movable by a certain axial compression force. Dimension L is given for a
coupling sleeve end when not mated. Coupling sleeve compression force must be 2,9 N to 6,9 N when a position of
the coupling sleeve endface from datum Z is in the range of 0 mm to 0,1 mm to the right or to the left of datum Z.
NOTE 5 An adaptor coupling part must be unlocked by a left-direction movement of a coupling sleeve, when it is
separate from an adaptor. When the coupling sleeve is moved for unlocking, a position of the coupling sleeve
endface must be larger than 2,0 mm in the left direction from the datum Z.
– 16 – 61754-7 CEI:2004
Y
Y Y
Deux fibres
Quatre fibres
Huit fibres
Y
Y
Dix fibres
Douze fibres
IEC 1594/04
Figure 2b – Diagrammes d’emplacement de la cible de référence optique
(suite à la page suivante)
X
X 0,125 0,125
0,125 0,125
0,375
0,375
0,625
0,625
0,875
0,875
X
1,125 1,125
0,125 0,125
0,375 0,375
X 0,125 0,125
0,375
0,375
X
0,125 0,125
0,625
0,625
0,875
0,875
1,125 1,125
0,375
1,375 1,375 0,375
0,625
0,625
0,875
0,875
61754-7 IEC:2004 – 17 –
Y
Y Y
Two fibres
Four fibres
Eight fibres
Y
Y
Ten fibres
Twelve fibres
IEC 1594/04
Figure 2b – Optical datum target location diagrams (continued on next page)
X
X
0,125 0,125
0,125 0,125
0,375
0,375
0,625
0,625
0,875
0,875
X
1,125 1,125
0,125 0,125
0,375 0,375
X 0,125 0,125
0,375
0,375
X 0,125 0,125
0,625
0,625
0,875
0,875
1,125
1,125
0,375
1,375 1,375 0,375
0,625
0,625
0,875
0,875
– 18 – 61754-7 CEI:2004
0,250
0,250
0,250
0,250
Y
Y
Seize fibres
Vingt fibres
0,250 0,250
Y
Vingt-quatre fibres
IEC 1595/04
Figure 2b – Diagrammes d’emplacement de la cible de référence optique (suite)
NOTE Le diagramme de la cible de référence optique est présenté sur la figure. Ici, la référence X est définie
comme la ligne passant au centre des deux trous de broches, et la référence Y est définie comme la ligne
perpendiculaire à la référence X et passant au point milieu des centres des deux trous de broches.
0,125 0,125 0,125 0,125
X
X
0,375 0,375 0,375
0,375
0,625 0,625
0,625 0,625
0,875 0,875
0,875 0,875
1,125
1,125
1,375 1,375
0,125 0,125
X
0,375
0,375
0,625
0,625
0,875
0,875
1,125
1,125
61754-7 IEC:2004 – 19 –
0,250
0,250
0,250
0,250
Y
Y
Sixteen fibres
Twenty fibres
0,250
0,250
Y
IEC 1595/04
Twenty four fibres
Figure 2b – Optical datum target location diagrams (continued)
NOTE The optical datum target location diagram is shown in the figure. Here, datum X is defined as the line
passing through two pin-hole centres, and datum Y is defined as the line perpendicular to datum X and passing
through the midpoint of two pin-hole centres.
0,125 0,125 0,125 0,125
X
X
0,375
0,375 0,375 0,375
0,625 0,625
0,625 0,625
0,875 0,875
0,875 0,875
1,125 1,125
1,375
1,375
0,125 0,125
X
0,375
0,375
0,625
0,625
0,875
0,875
1,125
1,125
– 20 – 61754-7 CEI:2004
BB
BC
B
IEC 1596/04
Figure 2c – Broche étalon
Tableau 1b – Dimensions de la broche étalon
Dimensions
Référence mm Notes
Minimale Maximale
A 0,698 5 0,699 0 1
B 10,8 11,2 2
BA 0,2 0,4
BB 0,2 0,5
BC 6,0 –
NOTE 1 Rugosité de surface R = 0,1 μm pour la longueur de la dimension BC.
z
NOTE 2 Dimensions types.
∅BA
∅A
0,0005
61754-7 IEC:2004 – 21 –
BB
BC
B
IEC 1596/04
Figure 2c – Gauge pin
Table 1b – Dimensions of the gauge pin
Dimensions
mm
Reference Notes
Minimum Maximum
A 0,698 5 0,699 0 1
B 10,8 11,2 2
BA 0,2 0,4
BB 0,2 0,5
BC 6,0 –
NOTE 1 Surface roughness R = 0,1 μm for the length of dimension BC.
z
NOTE 2 Typical dimensions.
∅BA
∅A
0,0005
– 22 – 61754-7 CEI:2004
Figure 2d – Etalon pour la fiche
Tableau 1c – Dimensions de l’étalon pour la fiche
Dimensions
Référence mm Notes
Minimale Maximale
A 0,698 5 0,699 0 Pour deux broches, 1
C 4,599 5 4,600 5
D 6,3 6,5 2
U 2,4 2,5 2
BA 0,2 0,4
BB 0,2 0,5
BC 6,0 6,5
NOTE 1 Rugosité de surface R = 0,1 μm.
z
NOTE 2 Dimensions types.
61754-7 IEC:2004 – 23 –
Figure 2d – Gauge for plug
Table 1c – Dimensions of the gauge for plug
Dimensions
Reference mm Notes
Minimum Maximum
A 0,698 5 0,699 0 For two pins, 1
C 4,599 5 4,600 5
D 6,3 6,5 2
U 2,4 2,5 2
BA 0,2 0,4
BB 0,2 0,5
BC 6,0 6,5
NOTE 1 Surface roughness R = 0,1 μm.
z
NOTE 2 Typical dimensions.
– 24 – 61754-7 CEI:2004
∅0,002 W
Broche-guide
Broche-guide
Manchon
d’accouplement Voir Figure 2b
W
BB
IEC 1597/04
Figure 3 – Interface angulaire pour connecteur MPO à fiche mâle
∅A
∅BA
T
∅E
∅F
U
∅G
∅H
61754-7 IEC:2004 – 25 –
∅0,002 W
Guide-pin
Guide-pin
Coupling sleeve
See Figure 2b
W
BB
IEC 1597/04
Figure 3 – MPO male plug connector angled interface
∅A
∅BA
T
∅E
∅F
U
∅G
∅H
– 26 – 61754-7 CEI:2004
Tableau 2 – Dimensions de l’interface angulaire pour connecteur MPO à fiche mâle
Référence Dimensions Notes
Minimale Maximale
A 0,697 mm 0,699 mm 1
C 4 597 mm 4,603 mm
D 6,3 mm 6,5 mm 2
E 8,34 mm 8,54 mm
F 9,49 mm 9,59 mm
G 10,85 mm 11,05 mm
H 12,19 mm 12,59 mm
I 8,8 mm 9,2 mm
J 7,9 mm 8,1 mm 3
K 1,4 mm –
L 0,2 mm 0,8 mm
M 2,4 mm 2,6 mm 4 et 5
N 2,8 mm 3,0 mm
O 4,89 mm 4,99 mm
P 5,59 mm 5,69 mm
Q 5,7 mm –
R – 7,7 mm
S 2,9 mm 3,1 mm
T – 0,8 mm
U 2,4 mm 2,5 mm
AA 42º 45º
AB
– 45º
AC – 45º
AD 7,5º
8,5º
BA
0,2 mm 0,4 mm
BB 0,2 mm 6
0,5 mm
CA 1,6 mm
3,3 mm
NOTE 1 Il faut que chaque broche-guide soit retenue par une force minimale de 19,6 N. Il faut que la
rugosité de surface R soit inférieure à 0,5 μm.
z
NOTE 2 La dimension C est définie comme la distance entre les centres des deux trous de broches.
NOTE 3 La dimension I est donnée pour le centre de la face terminale d’une fibre pour l’extrémité d’une
fiche non accouplée. On peut noter qu’une ferrule peut être déplacée par application d’une certaine force
de compression axiale, et ainsi la dimension I est variable. Il faut que la force de compression de la
ferrule soit comprise entre 7,8 N et 11,8 N lorsqu’une position de la face terminale de la fibre à partir de
la référence Z est dans la plage de 8,2 mm à 8,4 mm.
NOTE 4 Il faut que le manchon de couplage puisse être déplacé en appliquant une certaine force de
compression axiale. La dimension L est donnée pour l’extrémité d’un manchon de couplage non
accouplé. Il faut que la force de compression du manchon de couplage soit comprise entre 2,9 N et
6,9 N lorsqu’une position de la face terminale du manchon de couplage à partir de la référence Z est
dans la plage de 0 mm à 0,1 mm de part et d’autre de la référence Z.
NOTE 5 Il faut qu’une partie du couplage de l’adaptateur soit déverrouillée par un mouvement vers la
gauche du manchon de couplage, lorsqu’il est séparé de l’adaptateur. Lorsque le manchon de couplage
est déplacé pour déverrouillage, il faut qu’une position de la face terminale du manchon de couplage soit
supérieure à 2,0 mm vers la gauche par rapport à la référence Z.
NOTE 6 La forme de la partie haute de la broche-guide peut être ronde, symétrique par rapport à l’axe
de la broche-guide et de diamètre minimal de 0,15 mm.
61754-7 IEC:2004 – 27 –
Table 2 – Dimensions of the MPO male plug connector angled interface
Dimensions
Reference Notes
Minimum Maximum
A 0,697 mm 0,699 mm 1
C 4,597 mm 4,603 mm
D 6,3 mm 6,5 mm 2
E 8,34 mm 8,54 mm
F 9,49 mm 9,59 mm
G 10,85 mm 11,05 mm
H 12,19 mm 12,59 mm
I 8,8 mm 9,2 mm
J 7,9 mm 8,1 mm 3
K 1,4 mm –
L 0,2 mm 0,8 mm
M 2,4 mm 2,6 mm 4 and 5
N 2,8 mm 3,0 mm
O 4,89 mm 4,99 mm
P 5,59 mm 5,69 mm
Q 5,7 mm –
R – 7,7 mm
S 2,9 mm 3,1 mm
T – 0,8 mm
U 2,4 mm 2,5 mm
AA 42º 45º
AB –
45º
AC
– 45º
AD 7,5º
8,5º
BA 0,2 mm
0,4 mm
BB 6
0,2 mm 0,5 mm
CA 1,6 mm
3,3 mm
NOTE 1 Each guide pin must be retained with a minimum force of 19,6 N. Surface roughness R must
z
be below 0,5 μm.
NOTE 2 Dimension C is defined as the distance between two guide-pin centres.
NOTE 3 Dimension I is given for a fibre endface centre of a plug end when not mated. It is noticed that
a ferrule is movable by a certain axial compression force, and therefore the dimension I is variable.
Ferrule compression force must be 7,8 N to 11,8 N when a position of the fibre endface from the datum Z is
in the range of 8,2 mm to 8,4 mm.
NOTE 4 Coupling sleeve must be movable by a certain axial compression force. Dimension L is given
for a coupling sleeve end when not mated. Coupling sleeve compression force must be 2,9 N to 6,9 N
when a position of the coupling sleeve endface from datum Z is in the range of 0 mm to 0,1 mm to the
right or to the left of datum Z.
NOTE 5 An adaptor coupling part must be unlocked by a left-direction movement of a coupling sleeve,
when it is separate from an adaptor. When the coupling sleeve is moved for unlocking, a position of the
coupling sleeve endface must be larger than 2,0 mm in the
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...