Live working - Electrical insulating gloves

Arbeiten unter Spannung - Elektrisch isolierende Handschuhe

Travaux sous tension - Gants isolants électriques

Delo pod napetostjo – Električne izolirne rokavice

General Information

Status
Not Published
Publication Date
23-Nov-2026
Current Stage
4020 - Enquiry circulated - Enquiry
Start Date
02-May-2025
Due Date
24-Jun-2021
Completion Date
02-May-2025

Relations

Buy Standard

Draft
prEN IEC 60903:2025
English language
55 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2025
Delo pod napetostjo – Električne izolirne rokavice
Live working - Electrical insulating gloves
Arbeiten unter Spannung - Elektrisch isolierende Handschuhe
Travaux sous tension - Gants isolants électriques
Ta slovenski standard je istoveten z: prEN IEC 60903:2025
ICS:
13.260 Varstvo pred električnim Protection against electric
udarom. Delo pod napetostjo shock. Live working
13.340.40 Varovanje dlani in rok Hand and arm protection
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

78/1513/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 60903 ED4
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2025-05-02 2025-07-25
SUPERSEDES DOCUMENTS:
78/1506A/RR
IEC TC 78 : LIVE WORKING
SECRETARIAT: SECRETARY:
France Mr Jonathan HIRTZ
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):

ASPECTS CONCERNED:
Electricity transmission and distribution,Safety
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for
Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they
are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries”
clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for
submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Live working - Electrical insulating gloves

PROPOSED STABILITY DATE: 2027
NOTE FROM TC/SC OFFICERS:
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

Link to Committee Draft for Vote (CDV) online document:
https://osd.iec.ch/#/editor/archive/2e598776-2e6f-191e-e063-5b10000aeb5f/en/CCDV/1

How to access
This link leads you to the Online Standards Development (OSD) platform for National Mirror Committee’s
(NMC) comments. The project draft may be found further down this document.

Resource materials
We recommend NCs to review the available materials to better understand the member commenting on
the OSD platform. This includes the:
• OSD NC roles overview: here
• How to add and submit comments to the IEC: here
Contact
Should you require any assistance, please contact the IEC IT Helpdesk at helpdesk@iec.ch.

IEC 60903 ED4 © IEC 2025 – 1 – 78/1513/CDV

CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
4 Requirements . 10
4.1 General . 10
4.2 Classification . 10
4.3 Physical requirements . 11
4.3.1 Composition . 11
4.3.2 Dimensions . 11
4.3.3 Workmanship and finish . 13
4.4 Mechanical, climatic and environmental requirements . 14
4.5 Electrical requirements . 14
4.6 Marking . 15
4.7 Packaging . 15
4.8 Instructions for use . 16
5 Type tests . 16
5.1 General . 16
5.2 Visual and dimensional inspection . 16
5.2.1 General . 16
5.2.2 Classification . 16
5.2.3 Dimensions . 16
5.2.4 Thickness . 17
5.2.5 Workmanship and finish . 17
5.3 Marking . 17
5.3.1 Visual and dimensional inspection . 17
5.3.2 Durability of marking . 17
5.4 Packaging and instructions for use . 17
5.5 Mechanical tests . 17
5.5.1 General . 17
5.5.2 Tensile strength and elongation at break . 17
5.5.3 Resistance to mechanical puncture . 18
5.5.4 Tension set . 20
5.6 Dielectric tests . 20
5.6.1 General . 20
5.6.2 Moisture conditioning . 20
5.6.3 Test equipment . 21
5.6.4 Failure indicators. 21
5.6.5 Voltage dielectric test procedure . 21
5.7 Ageing test . 25
5.8 Thermal tests . 25
5.8.1 Low temperature test . 25
5.8.2 Flame retardancy test . 27

IEC 60903 ED4 © IEC 2025 – 2 – 78/1513/CDV

5.9 Tests on gloves or long gloves with special properties . 28
5.9.1 Category A - Acid resistance . 28
5.9.2 Category H - Oil resistance . 28
5.9.3 Category Z - Ozone resistance . 29
5.9.4 Category C - Extremely low temperature resistance . 29
5.9.5 Category F - Leakage current resistance . 29
5.10 Specific mechanical testing for composite gloves . 31
5.10.1 Abrasion resistance . 31
5.10.2 Cutting resistance . 33
5.10.3 Tear resistance . 36
6 Alternative tests in case of gloves having completed the production phase . 37
6.1 Tensile strength and elongation at break for unlined gloves . 37
6.2 Tensile strength and elongation at break for lined gloves . 38
6.3 Resistance to mechanical puncture . 38
6.4 Tension set . 38
6.5 Voltage dielectric tests . 38
7 Assessment of defects and verification of performance of gloves having
completed the production phase . 38
8 Modifications . 38
Annex A (informative) In-service recommendations . 39
A.1 General . 39
A.2 Storage prior to issue and between use . 39
A.3 Examination before use . 39
A.4 Temperature . 39
A.5 Precautions in use . 39
A.6 Periodic inspection and electrical re-testing . 40
Annex B (normative) Suitable for live working; double triangle (IEC 60417-5216:2002-
10) . 41
Annex C (normative) Chronological order for type tests . 42
C.1 General . 42
C.2 Group size requirements . 43
C.2.1 Group 1 . 43
C.2.2 Group 2 . 44
C.2.3 Group 3 . 44
C.2.4 Group 4 - Additional tests for composite gloves . 44
C.2.5 Group 5 - Additional tests for gloves of category A . 44
C.2.6 Group 6 - Additional tests for gloves of category H . 44
C.2.7 Group 7 - Additional tests for gloves of category Z . 44
C.2.8 Group 8 - Additional tests for gloves of category F . 44
Annex D (informative) Guidelines for the selection of the class of glove in relation to
nominal voltage of a system . 45
D.1 General . 45
D.2 AC . 45
D.3 DC . 45
Annex E (normative) Liquid for tests on gloves of category H - Oil resistance . 46
E.1 Particularities of liquid 102 . 46
E.2 Characteristics of oil no. 1 . 46

IEC 60903 ED4 © IEC 2025 – 3 – 78/1513/CDV

Annex F (normative) Cotton canvas additional characteristics . 47
Annex G (normative) Classification of defects and tests to be allocated . 49
Annex H (informative) Rationale for the classification of defects . 51
Bibliography . 53

Figure 1 – Contour of glove . 12
Figure 2 – Illustration of the working area . 14
Figure 3 – Dumb-bell test piece for mechanical tests (plan view) . 18
Figure 4 – Test plates and needle for resistance to mechanical puncture . 19
Figure 5 – Test set up for the dielectric test on glove . 23
Figure 6 – Bend (fold) line for low and extremely low temperature test . 26
Figure 7 – Set-up for low and extremely low temperature folding tests . 26
Figure 8 – Set-up for the flame retardancy test . 28
Figure 9 – Test arrangement for leakage current resistance .
...

Questions, Comments and Discussion