prEN IEC 62680-1-2:2026
(Main)Universal serial bus interfaces for data and power - Part 1-2: Common components - USB power delivery specification (Fast track)
- Status
- Not Published
- Publication Date
- 13-Apr-2028
- Current Stage
- 4020 - Enquiry circulated - Enquiry
- Start Date
- 06-Nov-2026
- Due Date
- 09-Oct-2026
- Completion Date
- 06-Nov-2026
prEN IEC 62680-1-2:2026 is a CLC draft of the USB Power Delivery specification for Universal Serial Bus interfaces for data and power. It defines how USB Power Delivery (USB PD) sources, sinks, ports, cables and cable plugs advertise capability, negotiate power, and exchange control and data messages so a connection can move from the default state to an explicit contract.
What does prEN IEC 62680-1-2:2026 specify?
prEN IEC 62680-1-2:2026 specifies the common USB PD components needed to deliver and negotiate power over USB, together with the communication rules that support that negotiation. The document is organized from architecture and terminology through power rules, electrical behavior, the physical layer, message formats, message usage, state diagrams and fast role swap timing.
Clause 1 introduces cable, connector and operational concepts, including the USB PD roles used by source, sink, dual-role and cable-related functions. Clause 2 sets the conventions, related documents and terms used throughout the specification. Clauses 3 to 7 cover power requirements, electrical requirements, the PD communications physical layer, message definitions and message usage; later clauses add the state-machine material and fast role swap timing and parameters shown in the table of contents.
What are the key requirements of prEN IEC 62680-1-2:2026?
Power rules for sources and sinks
Clause 3 defines the power capabilities that a compliant Source Port advertises and a compliant Sink Port can request. It distinguishes Guaranteed Capability Port and Managed Capability Port, which matters because the source may offer either fixed or dynamically managed output power.
Clause 3 also separates standard power range (SPR) behavior from extended power range (EPR) behavior. The source-side rules cover fixed, variable and battery supplies, SPR Programmable Power Supply (PPS), SPR Adjustable Voltage Supply (AVS) and EPR options, so implementers must choose which power objects and operating range they support and advertise them consistently.
The sink-side rules cover how a Sink Port uses the advertised power, including sink requirements, accessory support and PDUSB device requirements. In practice, that means the sink must request power within the limits of the selected contract and manage its own consumption according to the negotiated capability.
Electrical behavior during negotiation and transitions
Clause 4 gives the electrical behavior that accompanies power negotiation. It covers source bulk capacitance, source transitions, sink standby and suspend behavior, robust over-current, over-voltage and over-temperature protection, and the handling of detach events.
The source transition rules define controlled voltage changes and when the source may transition faster than the normal slew limits, such as first applying VBUS after attach, changing power role to Source, or moving from vSafe0V to vSafe5V during a Hard Reset. For hardware design, this is the part that drives converter response, protection thresholds and power-path timing.
Clause 4 also defines how a source should react to detach and how quickly it must return to vSafe0V. That matters because a compliant design must remove power safely when the cable or device disconnects, not just stop negotiating.
On the sink side, Clause 4 covers bulk capacitance, standby power, zero negotiated power, transient load behavior, peak current operation and robust sink protection. The practical effect is that a sink cannot assume unlimited inrush or overload margin - it must stay within the negotiated current and handle faults and disconnects safely.
Dual-role behavior is also defined here. Clause 4 describes power role swap, swap standby timing, hard reset response and VCONN power cycle behavior, so a dual-role device needs state logic for changing roles without violating timing or connector power rules.
Physical-layer signaling on the CC wire
Clause 5 defines the PD communications physical layer on the Configuration Channel (CC). It uses Bi-phase Mark Coding (BMC), preamble, packet formation, reset signaling, reception rules and electrical masks for transmitter and receiver behavior.
This matters because USB PD signaling is not just abstract messaging - the controller and PHY have to generate and decode the required waveforms on the CC line. The clause also covers collision avoidance and built-in self-test (BIST), which are important for interoperable implementations and test validation.
Message formats and data objects
Clause 6 defines the PD message structure: control messages, data messages, extended messages, headers, message IDs, chunking, vendor and product IDs, and the fields carried in each message type. It includes the core power negotiation messages such as Source_Capabilities, Sink_Capabilities and Request, plus role-swap, reset, status, PPS, battery, manufacturer and firmware-related messages.
The same clause defines the power data objects (PDOs), sink request data objects and extended capability fields used to advertise or request power. For implementers, this is where the firmware learns exactly how to encode the capabilities that a source advertises and the operating point that a sink requests.
Clause 6 also covers vendor-defined messages, structured and unstructured VDM handling, Discover Identity, Discover SVIDs, Discover Modes, Enter Mode and Exit Mode. That is the part used when a product needs to identify itself, expose supported modes or support alternate-mode discovery over USB PD.
Message usage, sequences and timers
Clause 7 explains how the messages are used in actual exchanges. It covers soft reset, data reset, hard reset, cable reset, collision avoidance, message discarding and the applicability tables that govern when a message is valid.
Clause 7 then sets out the atomic message sequences for power negotiation, power role swap, fast role swap, data role swap, VCONN swap, alert handling, Get Status and Get PPS Status. In practice, this is the policy-engine part of the standard: it tells software what sequence to send, when to wait, and how to recover if a partner rejects, waits or discards a message.
The later timing material and state diagrams support the same behavior at implementation level. The document includes fast role swap timers and parameters, which matter when a source is lost and the system must change power roles quickly.
What terms does prEN IEC 62680-1-2:2026 define?
- Default Contract - The initial non-negotiated power state after attachment, with 5 V as the default voltage and current limited by the advertised USB-C capability.
- Explicit Contract - The state reached after PD power negotiation, when Source and Sink have agreed the active power contract.
- Source Port - The port that provides power and advertises source capabilities to a partner.
- Sink Port - The port that receives power and requests the voltage and current it needs.
- Dual-Role Power (DRP) - A port that can change its power role through the PR_Swap process.
- Dual-Role Data (DRD) - A port that can change its data role through the DR_Swap process.
- Power Data Object (PDO) - The data object used to publish source or sink power capabilities in Source_Capabilities, EPR_Source_Capabilities, Sink_Capabilities or EPR_Sink_Capabilities messages.
- Programmable Power Supply (PPS) - An optional power mode where the source supports requested voltage and current values within the defined PPS range.
- Extended Power Range (EPR) - The higher-power operating range used when the source and sink support EPR mode.
- Fast Role Swap (FRS) - The rapid exchange of source and sink power roles when an external power supply is removed.
Who uses prEN IEC 62680-1-2:2026?
prEN IEC 62680-1-2:2026 is used by engineers who design USB PD sources, sinks, controllers, cables, cable plugs and USB-C connected products. It is also used by firmware and policy-engine developers who implement the negotiation state machines, message handling and reset behavior.
Test laboratories and compliance teams use it to verify signaling, timing, packet formats, PDO/APDO content and role-swap behavior. Buyers, quality managers and platform integrators use it to check whether a product supports the power range, messaging features and device roles needed for a USB-C system.
It is relevant to power adapters, laptops, docks, hubs, peripherals, battery-powered devices and products that expose manufacturer, battery, country or alternate-mode information over USB PD.
Which standards are used with prEN IEC 62680-1-2:2026?
- [USB-C] - Provides the connector, CC behavior, VBUS and VCONN concepts, detach behavior and other Type-C electrical rules used throughout the document.
- [IEC 60958-1] - Serves as the coding reference cited for BMC as a form of Manchester coding.
- [ISO 3166] - Defines the alpha-2 country codes used in Country_Info and related country-code messages.
- [IEC 62368-1] - Provides the TS1 and TS2 touch-temperature limits referenced for source and sink touch-temperature reporting.
- [USB2], [USB3] and [USB4] - Supply the data-capability and tunneling context used in capability fields, cable speed reporting and host/device support declarations.
- [TBT3] - Provides the Thunderbolt support context used in capability reporting and alternate-mode-related fields.
What does the prEN IEC 62680-1-2:2026 document contain?
The document contains figures for the USB PD device architecture, source and sink transition envelopes, BMC waveforms and state diagrams for PD behavior. It also contains tables for source and sink capability fields, PDO and APDO formats, message headers, alert data objects, extended message fields, battery and manufacturer information, timers and FRS parameters.
Several clauses are written as procedural sequences, such as power negotiation, hard reset, data reset, VCONN power cycle and role-swap handling. Those sequences are what implementers use to code policy engines and to build interoperability test cases.
The later sections also include detailed field definitions for source capabilities extended, sink capabilities extended, revision, status, PPS status, country information, security and firmware update messages. That content is used for design, conformance testing and protocol validation rather than for general product marketing or end-user operation.
Relations
- Effective Date
- 13-Oct-2026
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.
Sponsored listings
Frequently Asked Questions
prEN IEC 62680-1-2:2026 is a draft published by CLC. Its full title is "Universal serial bus interfaces for data and power - Part 1-2: Common components - USB power delivery specification (Fast track)". This standard covers: Universal serial bus interfaces for data and power - Part 1-2: Common components - USB power delivery specification (Fast track)
Universal serial bus interfaces for data and power - Part 1-2: Common components - USB power delivery specification (Fast track)
prEN IEC 62680-1-2:2026 is classified under the following ICS (International Classification for Standards) categories: 29.220 - Galvanic cells and batteries; 33.120 - Components and accessories for telecommunications equipment; 35.200 - Interface and interconnection equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN IEC 62680-1-2:2026 has the following relationships with other standards: It is inter standard links to EN IEC 62680-1-2:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN IEC 62680-1-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2026
Vmesniki univerzalnega serijskega vodila za podatke in napajanje - 1-2. del:
Skupne komponente - Specifikacija za zagotavljanje napajanja prek USB (hitri
postopek)
Universal serial bus interfaces for data and power - Part 1-2: Common components -
USB power delivery specification (Fast track)
Ta slovenski standard je istoveten z: prEN IEC 62680-1-2:2026
ICS:
35.200 Vmesniška in povezovalna Interface and interconnection
oprema equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
100/4611/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 62680-1-2 ED9
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2026-11-20 2027-02-12
SUPERSEDES DOCUMENTS:
IEC TC 100 : AUDIO, VIDEO AND MULTIMEDIA SYSTEMS AND EQUIPMENT
SECRETARIAT: SECRETARY:
Japan Ms Mahiru Uehara
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):
ASPECTS CONCERNED:
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
ATTENTION IEC-CENELEC PARALLEL VOTING
THE ATTENTION OF IEC NATIONAL COMMITTEES, MEMBERS
OF CENELEC, IS DRAWN TO THE FACT THAT THIS
COMMITTEE DRAFT FOR VOTE (CDV) IS SUBMITTED FOR
PARALLEL VOTING.
THE CENELEC MEMBERS ARE INVITED TO VOTE THROUGH
CENELEC ONLINE VOTING SYSTEM.
THE
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights
of which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).
TITLE:
Universal Serial Bus interfaces for data and power - Part 1-2: Common components - USB
Power Delivery specification (Fast track)
PROPOSED STABILITY DATE: 2031
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, or any part of it, for
any other purpose without permission in writing from IEC.
NOTE FROM TC/SC OFFICERS:
This is a fast-track process offered by USB-IF. The supplementing document, PDUSB Status Reporting
and Device States Revision 1.1 is also subject to approval.
Universal Serial Bus
Power Delivery Specification
Release 3.2, Version 1.2
May 20, 2026
r3.2 v1.2 May 2026 USB Power Delivery Specification 1
Universal Serial Bus Power Delivery Specification
Release 3.2, Version 1.2
ration, Renesas, STMicroelectronics, and Texas Instruments.
LIMITED COPYRIGHT LICENSE
The USB 3.0 Promoters grant a conditional copyright license under the copyrights embodied in the USB Power Delivery Specification to use and
reproduce the specification for the sole purpose of, and solely to the extent necessary for, evaluating whether to implement the specification in
products that would comply with the specification. Without limiting the foregoing, use of the specification for the purpose of filing or modifying any
patent application to target the specification or USB-compliant products is not authorized. Except for this express copyright license, no other rights
or licenses are granted, including without limitation any patent licenses. In order to obtain any additional intellectual property licenses or licensing
commitments associated with the specification, a party must execute the USB 3.0 Adopters Agreement. Note: By using the specification, you
accept these license terms on your own behalf and, in the case where you are doing this as an employee, on behalf of your employer.
INTELLECTUAL PROPERTY DISCLAIMER
This specification is provided to you "as is" with no warranties whatsoever, including any warranty of merchantability, non-infringement, or fitness
for any particular purpose. The authors of this specification disclaim all liability, including liability for infringement of any proprietary rights, relating
to use or implementation of information in this specification. The provision of this specification to you does not provide you with any license,
express or implied, by estoppel or otherwise, to any intellectual property rights.
® ® ® ®
• USB Type-C , USB-C , and USB4 are trademarks of the Universal Serial Bus Implementers Forum (USB-IF). DisplayPort is a regis-
tered trademark of VESA. Thunderbolt™ is a trademark of Intel Corporation. All product names are trademarks, registered trademarks,
or service marks of their respective owners.
™
• You may only use the Thunderbolt trademark or logo in conjunction with products designed to this specification that complete proper
™
certification and execute a Thunderbolt trademark license. See usb.org/compliance for further information.
• All rights reserved.
• Please send comments via electronic mail to techsup@usb.org.
• For industry information, refer to the USB Implementers Forum website at http://www.usb.org/.
2 USB Power Delivery Specification r3.2 v1.2 May 2026
Table of Contents
1. Introduction . 21
1.1. Cable and Connectors . 21
1.2. Operational Overview . 21
1.3. USB PD Roles . 21
1.3.1. Source Port . 21
1.3.2. Sink Port . 22
1.3.3. Downstream Facing Port (DFP) . 22
1.3.4. Upstream Facing Port (UFP) . 22
1.3.5. Dual-Role Power (DRP) Ports . 22
1.3.6. Dual-Role Data (DRD) Ports . 22
1.3.7. VCONN Source . 22
1.3.8. Cable Plugs . 22
1.4. Power Delivery Operational Contracts . 22
1.5. Source and Sink Operation in USB PD. 23
1.5.1. General Source-to-Sink Initial Interaction . 23
1.6. Common PD Device Types . 24
1.7. USB-PD Architectural Overview . 24
2. Glossary and Info . 26
2.1. Conventions . 26
2.1.1. Precedence . 26
2.1.2. Keywords . 26
2.1.3. Numbering . 27
2.2. Related Documents . 27
2.3. Terms and Abbreviations . 27
3. Port Power Requirements . 37
3.1. Introduction . 37
3.2. Source Port Power Requirements . 37
3.2.1. General Source Port Requirements . 37
3.2.2. Guaranteed Capability Port . 37
3.2.3. Managed Capability Port . 38
3.2.4. Source Voltage and Current Requirements . 38
3.2.5. Optional Source Voltage/Currents . 41
3.2.5.1. Fixed, Variable and Battery Supply . 41
3.2.5.2. SPR Programmable Power Supply (PPS) . 42
3.2.5.3. Extended Power Range (EPR) . 42
3.3. Dynamic Power Supply (DPS) . 45
3.4. Sink Power Requirements . 46
3.4.1. Sink Power Rule Considerations . 46
3.4.2. Sink Requirements . 47
3.5. Sink with Acessory Support . 47
3.6. PDUSB Device Requirements . 47
4. Power Delivery Electrical Requirements . 48
4.1. Source Requirements . 48
4.1.1. Behavioral Aspects . 48
4.1.2. Source Bulk Capacitance . 48
4.1.2.1. Source PDOs or APDOs . 49
4.1.3. Source Transitions . 50
4.1.3.1. Fixed Voltage Transitions . 50
4.1.3.2. AVS/PPS Transitions . 52
4.1.4. Non-application of VBUS Slew Rate Limits . 58
4.1.5. Robust Source Operation . 59
4.1.5.1. Output Over-Current Protection . 59
r3.2 v1.2 May 2026 USB Power Delivery Specification 3
4.1.5.2. Output Over-Voltage Protection .59
4.1.5.3. Over-Temperature Protection .59
4.1.5.4. vSafe5V Externally Applied to Ports Supplying vSafe5V .59
4.1.5.5. Detach .60
4.1.6. Source Peak Current Operation .60
4.1.7. Source Capabilities Extended Parameters .60
4.1.7.1. Load Step Slew Rate .61
4.1.7.2. Load Step Magnitude .61
4.1.7.3. Holdup Time Field .61
4.1.7.4. Compliance Field .61
4.1.7.5. Batteries .61
4.2. Sink Requirements .62
4.2.1. Behavioral Aspects .62
4.2.2. Sink Bulk Capacitance .62
4.2.3. Sink Standby .63
4.2.4. Suspend Power Consumption .63
4.2.5. Zero Negotiated Power .63
4.2.6. Transient Load Behavior .63
4.2.7. Considerations for Current Limit in PPS Mode .63
4.2.8. Sink Peak Current Operation.64
4.2.9. Robust Sink Operation.64
4.2.9.1. Sink Bulk Capacitance Discharge at Detach .64
4.2.9.2. Sink Over-Current Protection .64
4.2.9.3. Sink Over-Voltage Protection .65
4.2.9.4. Sink Over-Temperature Protection .65
4.3. Dual Role Ports .65
4.3.1. Swap Standby for the Initial Source .65
4.3.2. Swap Standby for the Initial Sink .65
4.3.3. Power Role Swap Sequence .66
4.4. Response to Hard Resets .67
4.4.1. Hard Reset Sequence .68
4.5. Transitions.69
4.5.1. Fixed and AVS transitions .69
4.5.1.1. Large-step voltage increases (Fixed or AVS) .69
4.5.1.2. Small-step voltage increases (AVS).71
4.5.1.3. Unchanged or decreased voltage transitions (current unchanged, increased, or de-
creased) .72
4.5.2. PPS voltage or current changes .74
4.5.2.1. PPS voltage transitions (CV Mode) .74
4.5.2.2. PPS current transitions (CL Mode) .76
4.6. VCONN Power Cycle .78
4.7. Electrical Parameters .78
4.7.1. Source Electrical Parameters .78
4.7.2. Sink Electrical Parameters .83
4.7.3. Common Electrical Parameters .84
5. PD Communications Physical Layer .85
5.1. Overview .85
5.2. Signaling Through DC Biasing .85
5.2.1. Power Role Indication .85
5.2.2. Collision Avoidance .85
5.2.2.1. Definition of Idle .86
5.3. BMC Signaling .86
5.3.1. Transmission .86
5.3.1.1. Packet Formation .87
5.3.1.2. Resets .90
4 USB Power Delivery Specification r3.2 v1.2 May 2026
5.3.2. Reception . 91
5.3.2.1. Preamble . 94
5.3.2.2. Ordered Sets (K-codes) . 94
5.3.2.3. Payload Processing . 94
5.3.3. Electrical Characteristics for Transmission and Reception . 95
5.3.4. Encoding and Signaling . 95
5.3.4.1. Transmit Mask . 98
5.3.4.2. Receive Masks . 100
5.3.4.3. Transmit Load Model . 105
5.3.4.4. Cable Plug Transceivers. . 106
5.3.4.5. Transceiver with VCONN Source Capability . 107
5.3.4.6. Capacitance when not transmitting . 108
5.3.4.7. Source Output Impedance . 108
5.3.4.8. Bit Rate Drift . 108
5.3.4.9. Inter-Frame Gap . 109
5.3.4.10. Shorting of Transmitter Output . 109
5.4. Built in Self-Test (BIST) . 109
5.4.1. BIST Carrier Mode . 109
5.5. PD Communications Physical Layer Parameters . 110
5.5.1. BMC Common Parameters . 110
5.5.2. BMC Transmitter Parameters . 110
5.5.3. BMC Receiver Parameters . 110
6. PD Communications Protocol Message Definitions . 112
6.1. Overview . 112
6.1.1. Message Types . 112
6.1.2. Message ID . 112
6.1.3. Specification Revision . 112
6.1.3.1. SOP Specification Revision Detection Process . 113
6.1.3.2. SOP' Specification Revision Detection Process . 113
6.1.4. Chunking . 114
6.1.5. Vendor and Product IDs . 115
6.2. Message Construction . 116
6.2.1. Message Header . 116
6.2.2. Number of Data Objects . 117
6.3. Control Message . 118
6.3.1. GoodCRC Message . 119
6.3.2. GotoMin Message (Deprecated) . 119
6.3.3. Accept Message . 119
6.3.4. Reject Message . 119
6.3.5. Ping Message (Deprecated) . 120
6.3.6. PS_RDY Message . 120
6.3.7. Get_Source_Cap Message . 120
6.3.8. Get_Sink_Cap Message . 121
6.3.9. DR_Swap Message . 121
6.3.10. PR_Swap Message . 121
6.3.11. VCONN_Swap Message . 121
6.3.12. Wait Message . 121
6.3.13. Soft_Reset Message . 122
6.3.14. Data_Reset Message . 122
6.3.15. Data_Reset_Complete Message . 122
6.3.16. Not_Supported Message . 122
6.3.17. Get_Source_Cap_Extended Message . 123
6.3.18. Get_Status Message . 123
6.3.19. FR_Swap Message . 123
6.3.20. Get_PPS_Status . 123
r3.2 v1.2 May 2026 USB Power Delivery Specification 5
6.3.21. Get_Country_Codes . 123
6.3.22. Get_Sink_Cap_Extended Message . 124
6.3.23. Get_Source_Info Message . 124
6.3.24. Get_Revision Message . 124
6.4. Data Message . 124
6.4.1. Capabilities Messages . 125
6.4.1.1. Source_Capabilities Message. 125
6.4.1.2. Sink_Capabilities Message . 126
6.4.1.3. Power Data Objects . 126
6.4.2. Request Message . 136
6.4.2.1. Sink Request Data Objects . 137
6.4.3. BIST Message . 140
6.4.3.1. BIST Test Data Mode . 140
6.4.3.2. BIST Shared Capacity Test Mode . 140
6.4.3.3. BIST Shared Test Mode Entry . 140
6.4.3.4. BIST Shared Test Mode Exit . 141
6.4.4. Battery_Status Message . 141
6.4.5. Alert Message . 142
6.4.5.1. Power State Change Extended Event . 144
6.4.5.2. Power Button Press Extended Event . 144
6.4.5.3. Power Button Release Extended Event . 144
6.4.5.4. Controller Initiated Wake Extended Event . 144
6.4.5.5. Source Reducing Capabilities Extended Event . 144
6.4.6. Get_Country_Info Message. 144
6.4.7. Enter_USB Message . 145
6.4.8. EPR_Request Message. 146
6.4.9. EPR_Mode Message . 147
6.4.10. Source_Info Message . 148
6.4.11. Revision Message . 149
6.4.12. Vendor Defined Message . 150
6.4.12.1. Unstructured VDM . 151
6.4.12.2. Structured VDM . 151
6.4.12.3. Discover Identity . 154
6.4.12.4. Discover SVIDs . 168
6.4.12.5. Discover Mode . 170
6.4.12.6. Enter Mode . 170
6.4.12.7. Exit Mode . 170
6.4.12.8. Attention . 171
6.5. Extended Message. 171
6.5.1. Extended Message Header . 172
6.5.1.1. Chunked . 172
6.5.2. Source_Capabilities_Extended Message . 173
6.5.2.1. Touch Current Field . 175
6.5.2.2. Peak Current Fields . 176
6.5.3. Status Message . 176
6.5.4. Get_Battery_Cap Message . 181
6.5.5. Get_Battery_Status Message . 181
6.5.6. Battery_Capabilities Message . 182
6.5.7. Get_Manufacturer_Info Message . 182
6.5.8. Manufacturer_Info Message . 183
6.5.9. Security_Request Message. 183
6.5.10. Security_Response Message . 183
6.5.11. Firmware_Update_Request Message . 184
6.5.12. Firmware_Update_Response Message . 184
6.5.13. PPS_Status Message . 184
6 USB Power Delivery Specification r3.2 v1.2 May 2026
6.5.14. Country_Info Message . 185
6.5.15. Country_Codes Message . 186
6.5.16. Sink_Capabilities_Extended Message . 186
6.5.16.1. Minimum PDP . 189
6.5.16.2. Operational PDP . 189
6.5.16.3. Maximum PDP . 190
6.5.17. Extended_Control Message . 190
6.5.17.1. EPR_Get_Source_Cap Message . 190
6.5.17.2. EPR_Get_Sink_Cap Message . 190
6.5.17.3. EPR_Keep_Alive Message . 191
6.5.17.4. EPR_Keep_Alive_Ack Message . 191
6.5.18. EPR_Source_Capabilities Message . 191
6.5.19. EPR_Sink_Capabilities Message . 192
6.5.20. Vendor_Defined_Extended Message . 192
6.6. Value Parameters . 193
7. PD Communications Protocol Message Usage . 194
7.1. Reset . 194
7.1.1. Soft Reset and Protocol Error . 194
7.1.2. Data Reset . 196
7.1.3. Hard Reset . 196
7.1.3.1. Cable Plugs and Hard Reset . 197
7.1.3.2. Modal Operation and Hard Reset . 197
7.1.4. Cable Reset . 197
7.2. Collision Avoidance . 197
7.3. Message Discarding . 198
7.4. Common Messages . 198
7.4.1. Accept . 198
7.4.2. Reject . 198
7.4.3. Wait . 199
7.5. Applicability Tables . 199
7.6. AMS Usages .
...