Fully supported metal sheet and strip for roofing, external cladding and internal lining - Product specification and requirements

This European Standard specifies the terminology, requirements and test methods for metal coil, strip, and flat sheets and factory made pieces intended for fully supported applications in roofing and wall cladding or lining. It does not apply to products manufactured on site.
This European Standard covers fully-supported aluminium, copper, lead, steel, stainless steel and zinc products with or without coatings, e.g. metallic, organic, inorganic or multi-layer (see Annex A).
This European Standard also includes rules for marking, labelling and evaluation of conformity.
Requirements concerning acoustical and insulation properties are not considered in this European Standard.
This European Standard does not include calculation or design requirements with regards to the works, installation techniques or the performance of the installed products.

Vollflächig unterstützte Dachdeckungs- und Wandbekleidungselemente für die Innen- und Außenanwendung aus Metallblech - Produktspezifikation und Anforderungen

Diese Europäische Norm legt die Terminologie, Anforderungen und Prüfverfahren für Metallrollen, Bänder und Flachbleche sowie werkmäßig hergestellte Stücke fest, die für vollflächig unterstützte Dachdeckungs- und Wandbekleidungsanwendungen geliefert werden. Die Norm gilt nicht für Produkte, die auf der Baustelle hergestellt werden.
Diese Europäische Norm gilt für vollflächig unterstützte Produkte aus Aluminium, Kupfer, Blei, Stahl, nicht-rostendem Stahl und Zink mit oder ohne Beschichtungen, die z. B. metallisch, organisch, anorganisch oder mehrschichtig sein können (siehe Anhang A).
Diese Europäische Norm enthält auch Regeln für die Kennzeichnung und Beschriftung sowie für die Konformitätsbewertung.
Diese Europäische Norm enthält keine Anforderungen zu den akustischen und Dämmeigenschaften.
Diese Europäische Norm enthält keine Bemessungs- oder Konstruktionsanforderungen hinsichtlich der Arbeits- oder Einbautechniken oder der Leistungsfähigkeit der eingebauten Produkte.

Tôles et bandes métalliques totalement supportées pour couverture, bardages extérieur et intérieur - Spécification de produit et exigences

La présente Norme européenne spécifie la terminologie, les prescriptions et les méthodes d’essai pour les bobines, les bandes et les tôles planes métalliques et les éléments fabriqués en usine destinés à des applications totalement supportées en toiture et bardages extérieur et intérieur. Elle ne s’applique pas aux produits fabriqués sur site.
La présente Norme européenne couvre les produits totalement supportés en aluminium, cuivre, plomb, acier, acier inoxydable et zinc avec ou sans revêtement, par exemple métallique, organique, inorganique ou multicouche (voir Annexe A).
La présente Norme européenne comporte également des règles relatives au marquage, à l’étiquetage et à l’évaluation de la conformité.
Les prescriptions relatives aux caractéristiques acoustiques et aux caractéristiques d’isolation ne sont pas considérées dans la présente Norme européenne.
La présente Norme européenne ne comporte pas de prescriptions relatives au calcul et à la conception des ouvrages, aux techniques d’installation ou à la performance des produits installés.

Povsem podprta pločevina in trakovi za pokrivanje streh ter zunanje in notranje obloge - Specifikacija za izdelek in zahteve

Ta evropski standard določa terminologijo, zahteve in preskusne metode za kovinsko tuljavo, trakove, ploščato pločevino in tovarniško izdelane kose, ki so namenjeni uporabi s povsem podprtimi strehami ter zunanjimi in notranjimi oblogami. Ne uporablja se za izdelke, ki se izdelajo na kraju samem. Ta evropski standard zajema povsem podprte izdelke iz aluminija, bakra, svinca, jekla, nerjavnega jekla in cinka z ali brez prevlek, npr. železnih, organskih, neorganskih ali večplastnih (glej dodatek A). Ta evropski standard vključuje tudi pravila za označevanje, etiketiranje in ocenjevanje skladnosti. Ta evropski standard ne zajema zahtev, ki se nanašajo na akustične in izolacijske lastnosti. Ta evropski standard ne vključuje zahtev za načrtovanje ali računanje, ki se nanašajo na delo, tehnike za namestitev ali zmogljivost nameščenih izdelkov.

General Information

Status
Published
Publication Date
30-Apr-2013
Current Stage
9060 - Closure of 2 Year Review Enquiry - Review Enquiry
Start Date
02-Dec-2025
Completion Date
02-Dec-2025

Relations

Standard
EN 14783:2013
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Vollflächig unterstützte Dachdeckungs- und Wandbekleidungselemente für die Innen- und Außenanwendung aus Metallblech - Produktspezifikation und AnforderungenTôles et bandes métalliques totalement supportées pour couverture, bardages extérieur et intérieur - Spécification de produit et exigencesFully supported metal sheet and strip for roofing, external cladding and internal lining - Product specification and requirements91.060.20StreheRoofs91.060.10Stene. Predelne stene. FasadeWalls. Partitions. Facades77.140.50SROL]GHONLFlat steel products and semi-productsICS:Ta slovenski standard je istoveten z:EN 14783:2013SIST EN 14783:2013en,fr,de01-junij-2013SIST EN 14783:2013SLOVENSKI
STANDARDSIST EN 14783:20061DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14783
May 2013 ICS 77.140.50; 77.150.01; 91.060.10; 91.060.20 Supersedes EN 14783:2006English Version
Fully supported metal sheet and strip for roofing, external cladding and internal lining - Product specification and requirements
Tôles et bandes métalliques totalement supportées pour couverture, bardages extérieur et intérieur - Spécification de produit et exigences
Vollflächig unterstützte Dachdeckungs- und Wandbekleidungselemente für die Innen- und Außenanwendung aus Metallblech - Produktspezifikation und Anforderungen This European Standard was approved by CEN on 24 February 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14783:2013: ESIST EN 14783:2013

Multilayer coated steel sheet . 15 A.1 General . 15 A.2 Substrate material. 15 A.3 Specific requirements . 15 A.3.1 Minimum nominal values of thickness . 15 A.3.2 Bituminous coating specification . 15 A.3.3 Durability . 16 A.4 Freedom from defects . 16 Annex B (normative)
Test conditions for the reaction to fire tests . 17 B.1 General . 17 B.2 Mounting and fixing conditions of test specimens in the SBI test . 17 B.2.1 General . 17 SIST EN 14783:2013

Clauses of this European Standard addressing the provisions of EU Construction Products Directive . 20 ZA.1 Scope and relevant characteristics . 20 ZA.2 Procedure(s) for the attestation of conformity of products . 21 ZA.2.1 Systems of attestation of conformity . 21 ZA.2.2 EC Certificate and Declaration of conformity . 24 ZA.3 CE marking and labelling. 25 Bibliography . 28
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
PCS ≤ 4,0 MJ/m2 or a mass ≤ 200 g/m2. NOTE Individual Member States may have "deemed to satisfy" lists which go beyond the list given in the Commission Decision 2000/553/EC. 5.1.2 Products classified without the need for further testing The following products are considered to be classified in classes B ROOF(t1), B ROOF(t2), B ROOF(t3) and B ROOF(t4) without further testing in accordance with Commission Decision 2005/403/EC: profiled steel sheets, flat steel sheets or panels of coil coated galvanised or zinc-aluminium alloy coated steel of metal thickness ≥ 0,40 mm with an organic external (weather side) coating and, optionally, a reverse (internal) side organic coating. The external coating is of a liquid-applied Plastisol paint of maximum nominal dry film thickness 0,2 mm, a PCS of not greater than 8,0 MJ/m2 and a maximum dry mass of 330 g/m2. The reverse side organic coating (if any) shall have a PCS of not greater than 4,0 MJ/m2 and a maximum dry mass of 200 g/m2. NOTE Reference will be made to Commission Decision 2005/403/EC for full details of the product and constructions. 5.1.3 Other products Products not meeting the definitions as given in 5.1.1 or 5.1.2 shall be tested in accordance with the relevant method(s) in CEN/TS 1187 and classified in accordance with EN 13501-5. The products to be tested shall be installed, in addition to the general provisions given in CEN/TS 1187, in a manner representative of their intended use. SIST EN 14783:2013

NOTE An informative database covering European and national provisions on dangerous substances is available at the Construction web site on EUROPA accessed through: http://ec.europa.eu/enterprise/construction/cpd-ds/ 6 Evaluation of conformity 6.1 General The conformity of the products covered by this European Standard with the requirements of this European Standard and with the declared values (including classes) shall be demonstrated by:  initial type testing comprising tests or other means of assessment;  factory production control by the manufacturer. If the base material is supplied with information about some or all characteristics required by this European Standard, the re-evaluation of these characteristics is not required for compliance with this European Standard as long as the production process does not change these characteristics. For the purposes of testing, the products may be grouped into families where it is considered the results for a given characteristic from any one product in the family are representative of all other products within that same family. A family may be formed for only one characteristic or more than one characteristic. Products within one family for one characteristic may or may not be within the same family in respect of other characteristics. 6.2 Initial type testing (ITT) 6.2.1 General Initial type testing shall be performed to show conformity with this European Standard. SIST EN 14783:2013

Table 3 have not been declared for the base material in accordance with Table 2 or are changed during the production process, the manufacturer claiming compliance with this European Standard shall assess and declare the characteristics of Table 3 that have not been declared. The base material may be presumed to have the performances stated of them by their supplier, although this does not replace the responsibility on the roofing, cladding or lining product manufacturer to ensure that only a base material having the correct values of characteristics to allow the finished roofing, cladding or lining product to meet the requirements of this European Standard is used. All characteristics in Clause 4 shall be subject to initial type testing, with the following exceptions:  external fire performance when using the CWFT option, in accordance with 5.1.2 or when deemed to satisfy in accordance with 5.1.1 (although measurement may be required to ensure that the product meets the definition required for CWFT and deemed to satisfy);  reaction to fire when deemed to satisfy Class A1, in accordance with 5.2.1;  release of dangerous substances that may be assessed indirectly by controlling the content of the substance concerned. Whenever a change occurs in the base material, the finished product or the production process (subject to the definition of a family), which could change significantly one or more of the characteristics, the type tests shall be repeated for the appropriate characteristic(s). The results of the initial type testing shall be recorded and held by the manufacturer for at least ten years after the end of production of the product to which they apply. SIST EN 14783:2013
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.