EN 3475-603:2011/AC:2011
(Corrigendum)Aerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking
Aerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking
This European Standard specifies a method of assessing the behaviour of cable insulation subject to an electric arc initiated and maintained by contaminating fluid along the surface of the insulation. This standard should be used together with EN 3475-100.
The primary aim of this test is:
- to produce, in a controlled fashion, continuous failure effects, which are representative of those, which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination. Electrical arcing occurs along the surface of the insulation between damage sites on adjacent cables; and
- to examine the aptitude of the insulation to track, to propagate electric arc to the electrical origin.
Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied. Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is agreed that sizes larger than 051 need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable should be assessed.
Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 603: Lichtbogenfestigkeit, feucht
Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d' essais - Partie 603: Résistance à l'amorcage et à la propagation d'arc èlectrique, essai humide
Aeronavtika - Električni kabli za uporabo v zračnih plovilih - Preskusne metode - 603. del: Odpornost proti električnemu obloku v vlažnih razmerah
Ta evropski standard določa metodo za ocenjevanje obnašanja kabelske izolacije, povezane z električnim oblokom, ki ga ustvarja in vzdržuje kontaminantna tekočina po površini izolacije.Ta standard se mora uporabljati skupaj z EN 3475-100. Glavni cilj tega standarda je:
- nadzorovano proizvajati nepretrgane učinke izpada delovanja, ki so reprezentativni za učinke, do katerih lahko pride, kadar je tipičen sveženj kablov poškodovan in kontaminiran z vodno tekočino. Do električnega obloka pride po površini izolacije med poškodovanimi mesti na sosednjih kablih; in
- pregledati sposobnost izolacije za sledenje, za širjenje električnega obloka do električnega vira.
Izvirno je definiran za omrežje 115 V izmeničnega toka, a ta preskus predlaga pogoje tudi za omrežje 230 V izmeničnega toka. Če ni drugače opredeljeno v standardu za proizvod, morajo biti izpolnjeni le pogoji za 115 V izmeničnega toka.
Za zadevne velikosti kablov je določenih šest ravni morebitnih okvarnih tokov (glej točko 7). Dogovor je, da velikosti, večjih od 051, ni treba ocenjevati, ker pojav kratkega stika postane prevladujoč pri nizkih impedancah voda.
Če ni drugače navedeno v tehničnem standardu/standardu za proizvod, je treba ocenjevati kable standardnih velikosti 002, 006 in 020.
General Information
- Status
- Withdrawn
- Publication Date
- 22-Nov-2011
- Withdrawal Date
- 20-Jan-2026
- Technical Committee
- ASD-STAN - Aerospace
- Drafting Committee
- ASD-STAN/D 2 - Electrical
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 10-Jan-2018
- Completion Date
- 28-Jan-2026
Relations
- Effective Date
- 31-Jan-2018
- Effective Date
- 08-Jun-2022
Get Certified
Connect with accredited certification bodies for this standard
National Aerospace and Defense Contractors Accreditation Program (NADCAP)
Global cooperative program for special process quality in aerospace.

NSF-ISR
NSF International Strategic Registrations.
Orion Registrar Inc.
US-based certification body for management systems.
Sponsored listings
Frequently Asked Questions
EN 3475-603:2011/AC:2011 is a corrigendum published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking". This standard covers: This European Standard specifies a method of assessing the behaviour of cable insulation subject to an electric arc initiated and maintained by contaminating fluid along the surface of the insulation. This standard should be used together with EN 3475-100. The primary aim of this test is: - to produce, in a controlled fashion, continuous failure effects, which are representative of those, which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination. Electrical arcing occurs along the surface of the insulation between damage sites on adjacent cables; and - to examine the aptitude of the insulation to track, to propagate electric arc to the electrical origin. Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied. Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is agreed that sizes larger than 051 need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable should be assessed.
This European Standard specifies a method of assessing the behaviour of cable insulation subject to an electric arc initiated and maintained by contaminating fluid along the surface of the insulation. This standard should be used together with EN 3475-100. The primary aim of this test is: - to produce, in a controlled fashion, continuous failure effects, which are representative of those, which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination. Electrical arcing occurs along the surface of the insulation between damage sites on adjacent cables; and - to examine the aptitude of the insulation to track, to propagate electric arc to the electrical origin. Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied. Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is agreed that sizes larger than 051 need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable should be assessed.
EN 3475-603:2011/AC:2011 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 3475-603:2011/AC:2011 has the following relationships with other standards: It is inter standard links to EN 3475-603:2018, EN 3475-603:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 3475-603:2011/AC:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 603: Lichtbogenfestigkeit, feuchtSérie aérospatiale - Câbles électriques à usage aéronautique - Méthodes d' essais - Partie 603: Résistance à l'amorcage et à la propagation d'arc èlectrique, essai humideAerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 3475-603:2011/AC:2011SIST EN 3475-603:2011/AC:2012en01-februar-2012SIST EN 3475-603:2011/AC:2012SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 3475-603:2011/AC
November 2011
Novembre 2011
November 2011 ICS 49.060 English version Version Française Deutsche Fassung
Aerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking
Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d' essais - Partie 603: Résistance à l'amorcage et à la propagation
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.