ASTM D8397-22
(Specification)Standard Specification for Acrylic and Reactive Adhesives for Installation of Vinyl and Rubber Floor Coverings
Standard Specification for Acrylic and Reactive Adhesives for Installation of Vinyl and Rubber Floor Coverings
SCOPE
1.1 This specification establishes minimum requirements for adhesives used for the installation of resilient floor coverings, within a climate-controlled structure, when adhered directly and permanently to a structurally sound and recommended substrate.
1.2 This specification will provide the means to determine adhesive bonding as a result of different resilient flooring backing systems used with PVC and rubber flooring materials.
1.3 Adhesives referenced in this specification may also be used for installation of carpets outlined in Specification D7799. Test methods and practices referenced in this specification will provide the means to determine adhesive bonding for PVC backed carpet types, whether classified as broadloom or tile.
1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D8397 − 22
Standard Specification for
Acrylic and Reactive Adhesives for Installation of Vinyl and
1
Rubber Floor Coverings
This standard is issued under the fixed designation D8397; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D1084 Test Methods for Viscosity of Adhesives
D1337 Practice for Storage Life of Adhesives by Viscosity
1.1 This specification establishes minimum requirements
and Bond Strength
for adhesives used for the installation of resilient floor
D2556 Test Method for Apparent Viscosity of Adhesives
coverings, within a climate-controlled structure, when adhered
Having Shear-Rate-Dependent Flow Properties Using Ro-
directly and permanently to a structurally sound and recom-
tational Viscometry
mended substrate.
D4783 Test Methods for Resistance of Adhesive Prepara-
1.2 This specification will provide the means to determine
tions in Container to Attack by Bacteria, Yeast, and Fungi
adhesive bonding as a result of different resilient flooring
D6004 Test Method for Determining Adhesive Shear
backing systems used with PVC and rubber flooring materials.
Strength of Resilient Flooring and Carpet Adhesives
D6862 Test Method for 90 Degree Peel Resistance of
1.3 Adhesives referenced in this specification may also be
used for installation of carpets outlined in Specification D7799. Adhesives
D6962 Practice for Operation of a Roller Chair Tester for
Test methods and practices referenced in this specification will
provide the means to determine adhesive bonding for PVC Pile Yarn Floor Coverings
D7149 Practice for Determining the Freeze Thaw Stability
backed carpet types, whether classified as broadloom or tile.
of Adhesives
1.4 The values stated in SI units are to be regarded as
D7799 Specification for Tufted and Woven Broadloom Car-
standard. The values given in parentheses after SI units are
pet Adhesives Without Homogenous PVC or Non-PVC
provided for information only and are not considered standard.
Backings
1.5 This standard does not purport to address all of the
D7888 Practice for Evaluating Adhesive and the Effects of
safety concerns, if any, associated with its use. It is the
Plasticizer Found Within Polyvinyl Chloride-Backed
responsibility of the user of this standard to establish appro-
Floor Coverings
priate safety, health, and environmental practices and deter-
F2199 Test Method for Determining Dimensional Stability
mine the applicability of regulatory limitations prior to use.
and Curling Properties of Resilient Flooring after Expo-
1.6 This international standard was developed in accor-
sure to Heat
dance with internationally recognized principles on standard-
2.2 Other Standards:
ization established in the Decision on Principles for the
California Specification 01350 Standard Method for the
Development of International Standards, Guides and Recom-
Testing and Evaluation of Volatile Organic Chemical
mendations issued by the World Trade Organization Technical
Emissions from Indoor Sources Using Environmental
Barriers to Trade (TBT) Committee.
3
Chambers, Version 1.1
ISO 4918 Resilient, textile and laminate floor coverings —
2. Referenced Documents
4
Castor chair test
2
2.1 ASTM Standards:
OSHA Regulations 29 CFR 1910.1200 Hazard communica-
D907 Terminology of Adhesives 5
tion
6
SCAQMD 1168 Adhesive and Sealant Applications
1
This specification is under the jurisdiction of ASTM Committee D14 on
Adhesives and is the direct responsibility of Subcommittee D14.10 on Working
3
Properties. Available from CalRecycle, http://calrecycle.ca.gov.
4
Current edition approved May 1, 2022. Published May 2022. DOI: 10.1520/ Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
D8397-22. 4th Floor, New York, NY 10036, http://www.ansi.org.
2 5
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from Occupational Safety and Health Administration (OSHA), 200
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Constitution Ave., NW, Washington, DC 20210, http://www.osha.gov.
6
Standards volume information, refer to the standard’s Document Summary page on Available from South Coast Air Quality Management District, 21865 Copley
the ASTM website. Dr, Diamond Bar, CA 91765, http://www.aqmd.gov.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D8397 − 22
Superfund Amendments and Reauthorization Act of 1986 7.3 The adhesive shall not be reportable as a carcinogen as
7
Title III Section 31
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.