Standard Guide for Approved Methods of Installing a CVS (Central Vacuum System)

SIGNIFICANCE AND USE
The suggestions of this guide are intended to provide proper installation materials and practices to be used during the installation of a central-vacuum system.
SCOPE
1.1 This guide demonstrates proper methods for installing a central-vacuum system.
1.2 Appendix X1 contains additional sources of information that may be helpful to the user of this guide.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Sep-2007
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Guide
ASTM F2647-07 - Standard Guide for Approved Methods of Installing a CVS (Central Vacuum System)
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F2647 − 07 AnAmerican National Standard
Standard Guide for
Approved Methods of Installing a CVS (Central Vacuum
1
System)
This standard is issued under the fixed designation F2647; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope E814 Test Method for Fire Tests of Penetration Firestop
Systems
1.1 This guide demonstrates proper methods for installing a
E2174 PracticeforOn-SiteInspectionofInstalledFireStops
central-vacuum system.
F402 Practice for Safe Handling of Solvent Cements,
1.2 Appendix X1 contains additional sources of information
Primers, and Cleaners Used for Joining Thermoplastic
that may be helpful to the user of this guide.
Pipe and Fittings
1.3 The values stated in inch-pound units are to be regarded
F412 Terminology Relating to Plastic Piping Systems
as the standard. The values given in parentheses are for
F2158 Specification for Residential Central-Vacuum Tube
information only.
and Fittings
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
3. Terminology
responsibility of the user of this standard to establish appro-
3.1 Definitions:
priate safety and health practices and determine the applica-
3.2 For definitions of terms used in this guide, see Termi-
bility of regulatory limitations prior to use.
nology F412.
2. Referenced Documents
2
4. Significance and Use
2.1 ASTM Standards:
4.1 The suggestions of this guide are intended to provide
1
This guide is under the jurisdiction of ASTM Committee F11 on Vacuum
properinstallationmaterialsandpracticestobeusedduringthe
Cleanersand is the direct responsibility of Subcommittee F11.30 on Durability-
installation of a central-vacuum system.
Reliability.
Current edition approved Oct. 1, 2007. Published November 2007. DOI:
10.1520/F2647-07.
5. Materials
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.1 Plastic Materials—For information on plastic materials
Standards volume information, refer to the standard’s Document Summary page on
used for installing a CVS system, see Specification F2158.
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2647 − 07
APPENDIXES
(Nonmandatory Information)
X1. STORAGE
X1.1 Outside Storage—Plastic tube should be stored on a stored where the temperature exceeds 130°F (54°C).
flat surface or supported in a manner that will prevent sagging
X1.2 Inventoriesofplastictubeshouldbeusedonafirst-in,
or bending. Do not store tube in direct sunlight for long
periods. To prevent damage, tubing and fittings should not be first-out basis.
X2. JOINTS AND CONNECTIONS
X2.1 PVC tubing and fittings shall be joined by the solvent- X2.2 Metal tubing and fittings shall be joined according to
cement method. Appendix X4.
X3. SOLVENT CEMENT JOINTS
X3.1 TubeCutting—Cutthetubesquarewiththeaxis,using
a fine-tooth handsaw and a miter box. A rotary cutter may be
used if the cutting blades are specifically designed for cutting
plastic tube in such a way as not to raise a burr or ridge (flare)
at the cut end (see Fig. X3.1). Remove all burrs with a
deburring tool, knife, file, or abrasive paper.
X3.2 Dry Fit Test—The solvent cement joint is designed so
that there will generally be interference of the tube wall with
the fitting socket before the tube is fully inserted. Insert the
tubeintothefittingandcheckthattheinterferenceoccursabout
FIG. X3.2 Tube Entering Dry Fitting
1 2
⁄3 to ⁄3 of the socket depth (Fig. X3.2).
X3.3 Cleaning—Surfaces to be joined must be cleaned and
the applicator immersed in cement between applications. (See
be free of dirt, moisture, oil, and other foreign material. If this
Practice F402 for proper handling procedures.)
cannot be accomplished by wiping with a clean, dry cloth, a
X3.4.2 Application of Cement—PVC solvent cement is fast
chemical or mechanical cleaner must be used. If a chemical
drying,and,therefore,thecementshallbeappliedasquicklyas
cleaner is used, apply with an applicator. (Warning—Skin
possible, consistent with good workmanship (see Fig. X3.3).
contact with chemical cleaners should be avoided.)
The surface temperature of the mating surfaces should not
X3.4 Application Procedure: exceed 110°F (43°C) at the time of assembly.
X3.4.1 Handling Cement—Keep the cement can closed and X3.4.3 Apply cement lightly but uniformly to the outside of