ASTM F842-17
(Test Method)Standard Test Methods for Measuring the Forced Entry Resistance of Sliding Door Assemblies, Excluding Glazing Impact
Standard Test Methods for Measuring the Forced Entry Resistance of Sliding Door Assemblies, Excluding Glazing Impact
SIGNIFICANCE AND USE
5.1 These test methods are intended to establish a measure of resistance for sliding door assemblies subjected to attacks (other than impacting glazing materials) by unskilled or opportunistic burglars. Resistance to higher levels of force generated by skilled burglary attack requires methods, such as alarms, communication, or apprehension systems, or special security glazing materials more sophisticated than those evaluated by these test methods. Technicians performing the test should understand the intent of this test method and should be trained on the execution and pass/fail criteria.
5.2 Entry through a sliding door assembly can be accomplished by impacting or removing glazing materials. This method does not evaluate glazing materials for breakage or de-glazing. Other standards must be used to evaluate forced entry by impacting or removing glazing.
5.3 Acceptance criteria for performance levels are a matter for authorities having specific jurisdiction to establish. Suggested guidelines are found in Annex A1.
SCOPE
1.1 These test methods determine the ability of sliding door assemblies to restrain, delay, or frustrate forced entry.
1.2 For purposes of these test methods, sliding door assemblies are defined as described in 1.2.1 – 1.2.4 and as shown in Fig. 1. Sliding door assemblies with a combination of operable panels and fixed panels (lites) shall be classified and tested separately for each type.
FIG. 1 Typical Horizontal Sliding Door Assembly Types (viewed from the exterior)
1.2.1 Type A—A sliding door assembly which incorporates one or more sliding panels that lock to the jamb.
1.2.2 Type B—A sliding door assembly which incorporates one or more sliding panels that lock to an intermediate jamb.
1.2.3 Type C—A sliding door assembly which incorporates one or more sliding panels that abut and lock to other panels.
1.2.4 Type D—A sliding door assembly which incorporates one or more fixed or stationary panels that are designed not to open.
Note 1: See Fig. 1 for graphic depiction of sliding door assembly types.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F842 − 17
Standard Test Methods for
Measuring the Forced Entry Resistance of Sliding Door
1
Assemblies, Excluding Glazing Impact
This standard is issued under the fixed designation F842; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope 2. Referenced Documents
2
1.1 These test methods determine the ability of sliding door 2.1 ASTM Standards:
assemblies to restrain, delay, or frustrate forced entry. E631 Terminology of Building Constructions
E699 Specification for Agencies Involved in Testing, Quality
1.2 For purposes of these test methods, sliding door assem-
Assurance, and Evaluating of Manufactured Building
blies are defined as described in 1.2.1 – 1.2.4 and as shown in
Components
Fig. 1. Sliding door assemblies with a combination of operable
3
2.2 AAMA Standard:
panels and fixed panels (lites) shall be classified and tested
AAMA 1303.5 Voluntary Specifications for Forced Entry
separately for each type.
Resistant Aluminum Sliding Glass Doors
1.2.1 Type A—A sliding door assembly which incorporates
3
2.3 CAWM Standards:
one or more sliding panels that lock to the jamb.
CAWM 300-96 Forced Entry Resistance Tests for Sliding
1.2.2 Type B—A sliding door assembly which incorporates
Glass Doors
one or more sliding panels that lock to an intermediate jamb.
CMBSO 1-79 California Model Building Security Ordi-
1.2.3 Type C—A sliding door assembly which incorporates
nance
one or more sliding panels that abut and lock to other panels.
1.2.4 Type D—A sliding door assembly which incorporates
3. Terminology
one or more fixed or stationary panels that are designed not to
open.
3.1 Definitions—Definitions for standard terminology can
be found in Terminology E631.
NOTE 1—See Fig. 1 for graphic depiction of sliding door assembly
types.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 door frame assembly, n—the combination of a head,
1.3 The values stated in inch-pound units are to be regarded
sill, and jambs surrounding and supporting fixed and sliding
as standard. The values given in parentheses are mathematical
panels.
conversions to SI units that are provided for information only
and are not considered standard.
3.2.2 fixed jamb stile, n—vertical members of fixed or
stationary panels adjacent to any jamb.
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
3.2.3 intermediate jamb, n—vertical member of a frame
responsibility of the user of this standard to establish appro-
other than the outermost vertical members.
priate safety, health, and environmental practices and deter-
3.2.4 locking device(s) (lock), n—one or more components
mine the applicability of regulatory limitations prior to use.
of a sliding door assembly intended to resist opening of the
1.5 This international standard was developed in accor-
sliding door panel from the exterior.
dance with internationally recognized principles on standard-
3.2.5 sliding door assembly, n—a combination of one or
ization established in the Decision on Principles for the
more sliding door panels with or without one or more fixed
Development of International Standards, Guides and Recom-
panels within a common frame.
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
1
These test methods are under the jurisdiction of ASTM Committee E06 on contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Performance of Buildings and are the direct responsibility of Subcommittee E06.51 Standards volume information, refer to the standard’s Document Summary page on
on Performance of Windows, Doors, Skylights and Curtain Walls. the ASTM website.
3
Current edition approved Oct. 1, 2017. Published November 2017. Originally Available from the American Architectural Manufacturers Association
approved in 1983. Last previous edition approved in 2014 as F842 – 14. DOI: (AAMA), 1827 Walden Office Square, Suite 550, Schaumburg, IL 60173-4268,
10.1520/F0842-17. http://www.aamanet.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F842 − 17
FIG. 1 Typical Horizontal Sliding Door Assembly Types (viewed from the exterior)
4. Summary of Test Method to a wall support fixture, and, after removing all exterior
fasteners and loose component items, specified loads
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F842 − 14 F842 − 17
Standard Test Methods for
Measuring the Forced Entry Resistance of Sliding Door
1
Assemblies, Excluding Glazing Impact
This standard is issued under the fixed designation F842; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope
1.1 These test methods determine the ability of sliding door assemblies to restrain, delay, or frustrate forced entry.
1.2 For purposes of these test methods, sliding door assemblies are defined as described in 1.2.1 – 1.2.4 and as shown in Fig.
1. Sliding door assemblies with a combination of operable panels and fixed panels (lites) shall be classified and tested separately
for each type.
1.2.1 Type A—A sliding door assembly which incorporates one or more sliding panels that lock to the jamb.
1.2.2 Type B—A sliding door assembly which incorporates one or more sliding panels that lock to an intermediate jamb.
1.2.3 Type C—A sliding door assembly which incorporates one or more sliding panels that abut and lock to other panels.
1.2.4 Type D—A sliding door assembly which incorporates one or more fixed or stationary panels that are designed not to open.
NOTE 1—See Fig. 1 for graphic depiction of sliding door assembly types.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
E631 Terminology of Building Constructions
E699 Specification for Agencies Involved in Testing, Quality Assurance, and Evaluating of Manufactured Building Components
3
2.2 AAMA Standard:
AAMA 1303.5 Voluntary Specifications for Forced Entry Resistant Aluminum Sliding Glass Doors
3
2.3 CAWM Standards:
CAWM 300-96 Forced Entry Resistance Tests for Sliding Glass Doors
CMBSO 1-79 California Model Building Security Ordinance
3. Terminology
3.1 Definitions—Definitions for standard terminology can be found in Terminology E631.
3.2 Definitions of Terms Specific to This Standard:
1
These test methods are under the jurisdiction of ASTM Committee E06 on Performance of Buildings and are the direct responsibility of Subcommittee E06.51 on
Performance of Windows, Doors, Skylights and Curtain Walls.
Current edition approved May 1, 2014Oct. 1, 2017. Published June 2014November 2017. Originally approved in 1983. Last previous edition approved in 20132014 as
F842 – 13.F842 – 14. DOI: 10.1520/F0842-14.10.1520/F0842-17.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from the American Architectural Manufacturers Association (AAMA), 1827 Walden Office Square, Suite 550, Schaumburg, IL 60173-4268, http://
www.aamanet.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F842 − 17
FIG. 1 Typical Horizontal Sliding Door Assembly Types (viewed from the exterior)
3.2.1 door frame assembly, n—the combination of a head, sill, and jambs surrounding and supporting fixed and sliding panels.
3.2.2 fixed jamb stile, n—vertical members of fixed or stationary panels adjacent to any jamb.
3.2.3 intermediate jamb, n—vertical member of a frame other than the outermost vertical members.
2
---------------------- Page: 2 ----------------------
F842 − 17
3.2.4 locking device(s) (lock), n—one or m
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.