SIGNIFICANCE AND USE
5.1 Rigid foam such as RCPS is used in the building construction industry. Because it is sensitive to certain components contained in adhesives which cause it to dissolve, it is important to have a test method to determine whether an adhesive is compatible with RCPS foam. This test method would help the end user decide which adhesive to use with RCPS foam by quantitatively measuring the amount of cavitation formed by the components contained in the adhesive.
SCOPE
1.1 This test method covers a practical means of measuring the degree of rigid cellular polystyrene (RCPS) foam cavitation damage when an adhesive is used to bond this substrate.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D5113 − 97 (Reapproved 2016)
Standard Test Method for
Determining Adhesive Attack on Rigid Cellular Foam
This standard is issued under the fixed designation D5113; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Summary of Test Method
1.1 This test method covers a practical means of measuring 4.1 This test method consists of testing two RCPS sections
thedegreeofrigidcellularpolystyrene(RCPS)foamcavitation bonded by adhesive and allowed to set for 24 h. Before
evaluation, the degree of cavitation is measured and recorded.
damage when an adhesive is used to bond this substrate.
1.2 The values stated in SI units are to be regarded as the
5. Significance and Use
standard. The values given in parentheses are for information
5.1 Rigid foam such as RCPS is used in the building
only.
construction industry. Because it is sensitive to certain compo-
1.3 This standard does not purport to address all of the
nents contained in adhesives which cause it to dissolve, it is
safety concerns, if any, associated with its use. It is the
important to have a test method to determine whether an
responsibility of the user of this standard to establish appro-
adhesive is compatible with RCPS foam. This test method
priate safety and health practices and determine the applica-
would help the end user decide which adhesive to use with
bility of regulatory limitations prior to use.
RCPS foam by quantitatively measuring the amount of cavi-
tation formed by the components contained in the adhesive.
2. Referenced Documents
2.1 ASTM Standards: 6. Apparatus
C578 Specification for Rigid, Cellular Polystyrene Thermal
6.1 Circular Template, with an inside diameter of 25 mm
Insulation
(1.0 in.) and a depth of 6 mm ( ⁄4 in.).
D907 Terminology of Adhesives
6.2 Circulating Air Oven, for elevated temperature testing,
capable of being held at 40 6 1°C (104 6 2°F).
3. Terminology
3.1 Definitions:
7. Materials
3.1.1 Many terms in this standard are defined in Terminol-
7.1 For the test, use Type IV RCPS foam with a nominal
ogy D907.
thickness of 25 mm (1.0 in.).
3.2 Definitions of Terms Specific to This Standard:
7.2 If another type is used, record the type, thickness and
3.2.1 cavitation damage, n—as related to rigid cellular
density.
polystyrene foam, the pitting and wearing away of the surface.
3.2.1.1 Discussion—Damage may include loss of material,
8. Conditioning
surface deformation, or any other changes in microstructure,
8.1 Unless otherwise agreed upon by the purchaser and the
properties, or appearance.
manufacturer, condition the test specimen and adhesive 24 h
3.3 Abbreviations:
prior to testing at 23 6 1°C (73 6 2°F) and 50 6 5 % relative
3.3.1 RCPS—Rigid cellular polystyrene.
humidity.
9. Procedure
This test method is under the jurisdiction of ASTM Committee D14 on
9.1 Prepare enough specimens so that two assemblies are
Adhesives and is the direct responsibility of Subcommittee D14.10 on Working
tested at both temperatures.
Properties.
9.1.1 For each test, cut two sections of RCPS into 76 mm (3
Current edition approved May 1, 2016. Published May 2016. Originally
ɛ1
in.) by 76 mm (3 in.) specimens.
app
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: D5113 − 97 (Reapproved 2011) D5113 − 97 (Reapproved 2016)
Standard Test Method for
Determining Adhesive Attack on Rigid Cellular Foam
This standard is issued under the fixed designation D5113; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
ε NOTE—Units of measure were editorially changed from hard to soft conversions throughout the text in April 2011.
1. Scope
1.1 This test method covers a practical means of measuring the degree of rigid cellular polystyrene (RCPS) foam cavitation
damage when an adhesive is used to bond this substrate.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
C578 Specification for Rigid, Cellular Polystyrene Thermal Insulation
D907 Terminology of Adhesives
3. Terminology
3.1 Definitions:
3.1.1 Many terms in this standard are defined in Terminology D907.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 cavitation damage, n—as related to rigid cellular polystyrene foam, the pitting and wearing away of the surface.
This test method is under the jurisdiction of ASTM Committee D14 on Adhesives and is the direct responsibility of Subcommittee D14.10 on Working Properties.
Current edition approved April 1, 2011May 1, 2016. Published April 2011May 2016. Originally approved in 1997. Last previous edition approved in 20052011 as
ɛ1
D5113 – 97 (2005).(2011) . DOI: 10.1520/D5113-97R11E01.10.1520/D5113-97R16.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’sstandard’s Document Summary page on the ASTM website.
3.2.1.1 Discussion—
Damage may include loss of material, surface deformation, or any other changes in microstructure, properties, or appearance.
3.3 Abbreviations:
3.3.1 RCPS—Rigid cellular polystyrene.
4. Summary of Test Method
4.1 This test method consists of testing two RCPS sections bonded by adhesive and allowed to set for 24 h. Before evaluation,
the degree of cavitation is measured and recorded.
5. Significance and Use
5.1 Rigid foam such as RCPS is used in the building construction industry. Because it is sensitive to certain components
contained in adhesives which cause it to dissolve, it is important to have a test method to determine whether an adhesive is
compatible with RCPS foam. This test method would help the end user decide which adhesive to use with RCPS foam by
quantitatively measuring the amount of cavitation formed by the components contained in the adhesive.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D5113 − 97 (2016)
6. Apparatus
6.1 Circul
...