ABSTRACT
This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. Mortar shall be mixed and shall be selected in accordance with the proportion specification prescribed. Shims shall be corrosion-resistant metal or plastic with a required minimum compressive strength. Courses of concrete masonry units between the leveling courses shall be placed without mortar on the bed or head joints. Place units in running bond. Remove burrs and butt blocks tightly. Use shims, mortar, or surface bonding mortar to plum and level individual units when necessary. Use clean mixing equipment and water free of deleterious amounts of acid, alkali, and organic materials. Mix only full bag multiples of material to overcome any segregation of ingredients. Mixing time shall be kept to a minimum, as over mixing may cause damage to the fibers. Before applying surface bonding mortar, wet the wall uniformly with water to prevent excessive suction of water from the surface bonding mortar. Trowel- or spray-apply surface bonding mortar to both sides of dry-stacked concrete masonry units. When a second coat of surface bonding mortar is to be applied, the first coat shall have taken its initial set. Dampen the wall with a water mist after a specified time, but within a day of application of surface bonding mortar. The top of the walls shall be covered with a nonstaining, waterproof covering to prevent moisture from entering the wall until the top is permanently protected.
SCOPE
1.1 This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. It does not include grout, reinforcing, anchorage, or control joints since their use is essentially the same as conventional concrete masonry construction, unless specifically mentioned in this practice.  
Note 1: Design and construction procedures for conventional concrete masonry construction are found in Building Code Requirements for Masonry Structures (TMS 402-16) and Specification for Masonry Structures (TMS 602-16).  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

ABSTRACT
This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted. The materials used as ingredients shall consist of the following: cements which shall be a Portland cement, blended hydraulic cement, hydraulic cement, or masonry cement; Type S or SA hydrated lime; Class N, F, or S pozzolan; aggregates; glass fibers; and additives. Physical properties of the packaged materials shall conform to the flexural strength, compressive strength, time of setting, and water retention requirements. The net weight, amount of mixing water, unit weight, and yield of the surface bonding mortar shall be calculated and reported.
SCOPE
1.1 This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted.  
1.2 This specification does not cover design or application. Consult the manufacturer for specific recommendations.  
1.3 Appendix X1 of this specification contains the recommended tests for evaluation of surface bonded masonry assemblages used to establish design loads for the composite wall.  
1.4 Appendix X2 through Appendix X5 of this specification contain additional tests that may be performed on surface bonding mortar.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. This hazard statement applies only to Section 9 of this specification.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    13 pages
    English language
  • Technical specification
    13 pages
    English language

ABSTRACT
This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted. The materials used as ingredients shall consist of the following: cements which shall be a Portland cement, blended hydraulic cement, hydraulic cement, or masonry cement; Type S or SA hydrated lime; Class N, F, or S pozzolan; aggregates; glass fibers; and additives. Physical properties of the packaged materials shall conform to the flexural strength, compressive strength, time of setting, and water retention requirements. The net weight, amount of mixing water, unit weight, and yield of the surface bonding mortar shall be calculated and reported.
SCOPE
1.1 This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted.  
1.2 This specification does not cover design or application. Consult the manufacturer for specific recommendations.  
1.3 Appendix X1 of this specification contains the recommended tests for evaluation of surface bonded masonry assemblages used to establish design loads for the composite wall.  
1.4 Appendix X2 through Appendix X5 of this specification contain additional tests that may be performed on surface bonding mortar.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. This hazard statement applies only to Section 9 of this specification.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    13 pages
    English language
  • Technical specification
    13 pages
    English language

ABSTRACT
This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted. The materials used as ingredients shall consist of the following: cements which shall be a Portland cement, blended hydraulic cement, hydraulic cement, or masonry cement; Type S or SA hydrated lime; Class N, F, or S pozzolan; aggregates; glass fibers; and additives. Physical properties of the packaged materials shall conform to the flexural strength, compressive strength, time of setting, and water retention requirements. The net weight, amount of mixing water, unit weight, and yield of the surface bonding mortar shall be calculated and reported.
SCOPE
1.1 This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted.  
1.2 This specification does not cover design or application. Consult the manufacturer for specific recommendations.  
1.3 Appendix X1 of this specification contains the recommended tests for evaluation of surface bonded masonry assemblages used to establish design loads for the composite wall.  
1.4 Appendix X2 through Appendix X5 of this specification contain additional tests that may be performed on surface bonding mortar.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. This hazard statement applies only to Section 9 of this specification.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    13 pages
    English language
  • Technical specification
    13 pages
    English language

ABSTRACT
This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. Mortar shall be mixed and shall be selected in accordance with the proportion specification prescribed. Shims shall be corrosion-resistant metal or plastic with a required minimum compressive strength. Courses of concrete masonry units between the leveling courses shall be placed without mortar on the bed or head joints. Place units in running bond. Remove burrs and butt blocks tightly. Use shims, mortar, or surface bonding mortar to plum and level individual units when necessary. Use clean mixing equipment and water free of deleterious amounts of acid, alkali, and organic materials. Mix only full bag multiples of material to overcome any segregation of ingredients. Mixing time shall be kept to a minimum, as over mixing may cause damage to the fibers. Before applying surface bonding mortar, wet the wall uniformly with water to prevent excessive suction of water from the surface bonding mortar. Trowel- or spray-apply surface bonding mortar to both sides of dry-stacked concrete masonry units. When a second coat of surface bonding mortar is to be applied, the first coat shall have taken its initial set. Dampen the wall with a water mist after a specified time, but within a day of application of surface bonding mortar. The top of the walls shall be covered with a nonstaining, waterproof covering to prevent moisture from entering the wall until the top is permanently protected.
SCOPE
1.1 This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. It does not include grout, reinforcing, anchorage, or control joints since their use is essentially the same as conventional concrete masonry construction, unless specifically mentioned in this practice.  
Note 1: Design and construction procedures for conventional concrete masonry construction are found in Building Code Requirements for Masonry Structures (TMS 402-16) and Specification for Masonry Structures (TMS 602-16).  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

ABSTRACT
This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted. The materials used as ingredients shall consist of the following: cements which shall be a Portland cement, blended hydraulic cement, hydraulic cement, or masonry cement; Type S or SA hydrated lime; Class N, F, or S pozzolan; aggregates; glass fibers; and additives. Physical properties of the packaged materials shall conform to the flexural strength, compressive strength, time of setting, and water retention requirements. The net weight, amount of mixing water, unit weight, and yield of the surface bonding mortar shall be calculated and reported.
SCOPE
1.1 This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted.  
1.2 This specification does not cover design or application. Consult the manufacturer for specific recommendations.  
1.3 Appendix X1 of this specification contains the recommended tests for evaluation of surface bonded masonry assemblages used to establish design loads for the composite wall.  
1.4 Appendix X2 through Appendix X5 of this specification contain additional tests that may be performed on surface bonding mortar.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This hazard statement applies only to Section 9 of this specification.

  • Technical specification
    12 pages
    English language
  • Technical specification
    12 pages
    English language

ABSTRACT
This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted. The materials used as ingredients shall consist of the following: cements which shall be a Portland cement, blended hydraulic cement, hydraulic cement, or masonry cement; Type S or SA hydrated lime; Class N, F, or S pozzolan; aggregates; glass fibers; and additives. Physical properties of the packaged materials shall conform to the flexural strength, compressive strength, time of setting, and water retention requirements. The net weight, amount of mixing water, unit weight, and yield of the surface bonding mortar shall be calculated and reported.
SCOPE
1.1 This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted.
1.2 This specification does not cover design or application. Consult the manufacturer for specific recommendations.
1.3 Appendix X1 of this specification contains the recommended tests for evaluation of surface bonded masonry assemblages used to establish design loads for the composite wall.
1.4 Appendix X2 through Appendix X5 of this specification contain additional tests that may be performed on surface bonding mortar.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This hazard statement applies only to Section 9 of this specification.

  • Technical specification
    11 pages
    English language

ABSTRACT
This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. Mortar shall be mixed and shall be selected in accordance with the proportion specification prescribed. Shims shall be corrosion-resistant metal or plastic with a required minimum compressive strength. Courses of concrete masonry units between the leveling courses shall be placed without mortar on the bed or head joints. Place units in running bond. Remove burrs and butt blocks tightly. Use shims, mortar, or surface bonding mortar to plum and level individual units when necessary. Use clean mixing equipment and water free of deleterious amounts of acid, alkali, and organic materials. Mix only full bag multiples of material to overcome any segregation of ingredients. Mixing time shall be kept to a minimum, as over mixing may cause damage to the fibers. Before applying surface bonding mortar, wet the wall uniformly with water to prevent excessive suction of water from the surface bonding mortar. Trowel- or spray-apply surface bonding mortar to both sides of dry-stacked concrete masonry units. When a second coat of surface bonding mortar is to be applied, the first coat shall have taken its initial set. Dampen the wall with a water mist after a specified time, but within a day of application of surface bonding mortar. The top of the walls shall be covered with a nonstaining, waterproof covering to prevent moisture from entering the wall until the top is permanently protected.
SCOPE
1.1 This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. It does not include grout, reinforcing, anchorage, or control joints since their use is essentially the same as conventional concrete masonry construction, unless specifically mentioned in this practice.
Note 1—Design and construction procedures for conventional concrete masonry construction are found in Building Code Requirements for Masonry Structures (TMS 402-08/ACI 530-08/ASCE 5-08) and Specification for Masonry Structures (TMS 602-08/ACI 530.1-08/ASCE 6-08).  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    3 pages
    English language
  • Standard
    3 pages
    English language

ABSTRACT
This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted. The materials used as ingredients shall consist of the following: cements which shall be a Portland cement, blended hydraulic cement, hydraulic cement, or masonry cement; Type S or SA hydrated lime; Class N, F, or S pozzolan; aggregates; glass fibers; and additives. Physical properties of the packaged materials shall conform to the flexural strength, compressive strength, time of setting, and water retention requirements. The net weight, amount of mixing water, unit weight, and yield of the surface bonding mortar shall be calculated and reported.
SCOPE
1.1 This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted.
1.2 This specification does not cover design or application. Consult the manufacturer for specific recommendations.
1.3 of this specification contains the recommended tests for evaluation of surface bonded masonry assemblages used to establish design loads for the composite wall.
1.4 through of this specification contain additional tests that may be performed on surface bonding mortar.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This hazard statement applies only to Section of this specification.
1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

  • Technical specification
    11 pages
    English language

SCOPE
1.1 This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. It does not include grout, reinforcing, anchorage, or control joints since their use is essentially the same as conventional concrete masonry construction, unless specifically mentioned in this practice.
Note 1—Design and construction procedures for conventional concrete masonry construction have been written by the American Concrete Institute, "Building Code Requirements for Concrete Masonry Structures" and the National Concrete Masonry Associations, "Specification for the Design and Construction of Load-Bearing Concrete Masonry."
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    3 pages
    English language

ABSTRACT
This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. Mortar shall be mixed and shall be selected in accordance with the proportion specification prescribed. Shims shall be corrosion-resistant metal or plastic with a required minimum compressive strength. Courses of concrete masonry units between the leveling courses shall be placed without mortar on the bed or head joints. Place units in running bond. Remove burrs and butt blocks tightly. Use shims, mortar, or surface bonding mortar to plum and level individual units when necessary. Use clean mixing equipment and water free of deleterious amounts of acid, alkali, and organic materials. Mix only full bag multiples of material to overcome any segregation of ingredients. Mixing time shall be kept to a minimum, as over mixing may cause damage to the fibers. Before applying surface bonding mortar, wet the wall uniformly with water to prevent excessive suction of water from the surface bonding mortar. Trowel- or spray-apply surface bonding mortar to both sides of dry-stacked concrete masonry units. When a second coat of surface bonding mortar is to be applied, the first coat shall have taken its initial set. Dampen the wall with a water mist after a specified time, but within a day of application of surface bonding mortar. The top of the walls shall be covered with a nonstaining, waterproof covering to prevent moisture from entering the wall until the top is permanently protected.
SCOPE
1.1 This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. It does not include grout, reinforcing, anchorage, or control joints since their use is essentially the same as conventional concrete masonry construction, unless specifically mentioned in this practice.
Note 1—Design and construction procedures for conventional concrete masonry construction have been written by the American Concrete Institute, "Building Code Requirements for Concrete Masonry Structures" and the National Concrete Masonry Associations, "Specification for the Design and Construction of Load-Bearing Concrete Masonry."
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    3 pages
    English language

SCOPE
1.1 This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted.
1.2 This specification does not cover design or application. Consult the manufacturer for specific recommendations.
1.3 Appendix X1 of this specification contains the recommended tests for evaluation of surface bonded masonry assemblages used to establish design loads for the composite wall.
1.4 Appendix X1 through Appendix X5 of this specification contain additional tests that may be performed on surface bonding mortar.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This hazard statement applies only to Section 9 of this specification.
1.6 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

  • Technical specification
    11 pages
    English language

SCOPE
1.1 This specification covers the materials, properties, and packaging of dry, combined materials for use as surface bonding mortar with concrete masonry units that have not been prefaced, coated, or painted.
1.2 This specification does not cover design or application. Consult the manufacturer for specific recommendations.
1.3 Appendix X1 of this specification contains the recommended tests for evaluation of surface bonded masonry assemblages used to establish design loads for the composite wall.
1.4 Appendix X1 through Appendix X5 of this specification contain additional tests that may be performed on surface bonding mortar.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This hazard statement applies only to Section 9 of this specification.
1.6 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

  • Technical specification
    11 pages
    English language

Frequently Asked Questions

C12.06 is a Technical Committee within ASTM International. It is named "Surface Bonding". This committee has published 13 standards.

C12.06 develops ASTM standards in the area of Information technology. Currently, there are 13 published standards from this technical committee.

ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.

A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.