This part of EN 50363 specifies the requirements for the cross-linked elastomeric insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50396.
Isolier-, Mantel- und Umhüllungswerkstoffe für Niederspannungskabel und -leitungen -- Teil 1: Vernetzte, elastomere Isoliermischungen
Dieser Teil der EN 50363 legt die Anforderungen an vernetzte, elastomere Isoliermischungen fest, die in Tabelle 1 aufgeführt sind. Die entsprechenden Prüfverfahren sind in den Normen der Reihe EN 60811 und EN 50396 beschrieben.
Matériaux pour enveloppe isolante, gainage et revêtement pour les câbles d'énergie basse tension -- Partie 1: Mélanges élastomères réticulés pour enveloppe isolante
La présente partie de la EN 50363 mentionne les exigences pour les mélanges d’isolation réticulés, donnés dans le Tableau 1. Les méthodes d’essais correspondantes sont données dans la série EN 60811 et dans la EN 50396.
Materiali za izoliranje, oplaščenje in prevleke nizkonapetostnih energetskih kablov – 1. del: Omrežene elastomerne snovi za izoliranje
General Information
- Status
- Published
- Publication Date
- 30-Apr-2006
- Technical Committee
- IEKA - Electric cables
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-May-2006
- Due Date
- 01-May-2006
- Completion Date
- 01-May-2006
Overview
EN 50363-1:2005 (CLC) - Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross‑linked elastomeric insulating compounds - specifies material requirements and test criteria for cross‑linked elastomeric insulating compounds used on low‑voltage energy cables. The standard defines compound types (EI2, EI3, EI4, EI6, EI7), their maximum operating temperatures and the mechanical, thermal and environmental performance required. Test methods are given by the EN 60811 series and EN 50396.
Key topics and technical requirements
- Compound types and maximum operating temperatures
- EI2: 180 °C (ordinary duty silicone rubber)
- EI3: 110 °C (ordinary duty EVA or equivalent)
- EI4: 60 °C (ordinary duty ethylene‑propylene rubber)
- EI6 / EI7: 90 °C (EPDM or equivalent; EI6 suited to handling down to −40 °C)
- Mechanical properties
- Minimum median tensile strength and elongation at break are specified per type (e.g., EI2 tensile median ≥ 5.0 N/mm², elongation ≥ 150%; EI3 tensile median ≥ 6.5 N/mm², elongation ≥ 200%).
- Requirements cover values before and after specified thermal ageing treatments.
- Ageing and thermal tests
- Ageing in air oven / air bomb with defined temperatures and durations per compound type (refer to EN 60811 methods).
- Limits on tensile variation and minimum retained elongation after ageing.
- Hot‑set and deformation
- Hot‑set test conditions (temperature, load and duration) and maximum elongation under load and after unloading.
- Low temperature performance
- Bending and elongation tests at specified low temperatures (no cracking; minimum elongation without break).
- Ozone resistance
- Methods A and B (EN 50396) with defined ozone concentrations, temperatures and durations to verify surface resistance to cracking.
- Other tests
- Pressure test at high temperature and other specific checks listed in Table 2; see EN 50363-0 for cross‑references.
Practical applications and users
- Cable manufacturers selecting or qualifying cross‑linked elastomeric insulation for low‑voltage energy cables.
- Compound formulators and material suppliers validating products against EN 50363-1:2005 requirements.
- Test laboratories performing EN 60811 / EN 50396 test suites for compliance and quality control.
- Engineers, purchasers and specifiers writing cable product specifications for building, industrial and utility applications.
- Regulatory and certification bodies assessing conformity to European electrotechnical standards.
Related standards
- EN 50363-0 (general requirements and cross‑references) - read together with Part 1.
- EN 60811 series - detailed test methods for cable insulating materials.
- EN 50396 - ozone resistance test methods.
EN 50363-1:2005 is essential when specifying or testing cross‑linked elastomeric insulating compounds for reliable, standardized performance in low‑voltage cable applications.
Frequently Asked Questions
SIST EN 50363-1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Insulating, sheathing and covering materials for low voltage energy cables -- Part 1: Cross-linked elastomeric insulating compounds". This standard covers: This part of EN 50363 specifies the requirements for the cross-linked elastomeric insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50396.
This part of EN 50363 specifies the requirements for the cross-linked elastomeric insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50396.
SIST EN 50363-1:2006 is classified under the following ICS (International Classification for Standards) categories: 29.035.20 - Plastics and rubber insulating materials; 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 50363-1:2006 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 50363-1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI SIST EN 50363-1:2006
STANDARD
maj 2006
Materiali za izoliranje, oplaščenje in prevleke nizkonapetostnih energetskih
kablov – 1. del: Omrežene elastomerne snovi za izoliranje
Insulating, sheathing and covering materials for low voltage energy cables – Part 1:
Cross-linked elastomeric insulating compounds
ICS 29.035.20; 29.060.20 Referenčna številka
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
EUROPEAN STANDARD EN 50363-1
NORME EUROPÉENNE
EUROPÄISCHE NORM November 2005
ICS 29.035.20
English version
Insulating, sheathing and covering materials
for low voltage energy cables
Part 1: Cross-linked elastomeric insulating compounds
Matériaux pour enveloppe isolante, Isolier-, Mantel- und
gainage et revêtement pour les câbles Umhüllungswerkstoffe für
d'énergie basse tension Niederspannungskabel und -leitungen
Partie 1: Mélanges élastomères réticulés Teil 1: Vernetzte, elastomere
pour enveloppe isolante Isoliermischungen
This European Standard was approved by CENELEC on 2005-11-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50363-1:2005 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50363-1
on 2005-11-01.
EN 50363 (in all its parts) supersedes the equivalent information at present in HD 21.1 S4,
HD 21.14 S1, HD 22.1 S4, HD 22.10 S1, HD 22.14 S2 and prHD 21.15 S1. The existing information in
these HDs will be deleted at the next maintenance review.
EN 50363-1 should be read in conjunction with EN 50363-0.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-11-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2007-11-01
– 3 – EN 50363-1:2005
Contents
1 Scope.4
2 Normative references.4
3 Definitions.4
4 Properties.4
Table 1 – Types of cross-linked elastomeric insulating compound.4
Table 2 – Requirements for the tests for crosslinked elastomeric insulating compounds .5
1 Scope
This part of EN 50363 specifies the requirements for the cross-linked elastomeric insulating
compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50396.
NOTE This part of EN 50363 is to be read in conjunction with EN 50363-0.
Table 1 – Types of cross-linked elastomeric insulating compound
Type Maximum material General application
operating
temperature
°C
EI 2 180 Ordinary duty silicone rubber (SiR)
EI 3 110 Ordinary duty EVA rubber or equivalent
EI 4 60 Ordinary duty ethylene propylene rubber
EI 6 90 Ordinary duty ethylene-propylene rubber or equivalent synthetic
elastomer for cables requiring handling down to –40 °C
EI 7 90 Ordinary duty ethylene propylene rubber or equivalent synthetic
e
...