General Information

Abstract

The present document defines requirements in respect of ElectroMagnetic Compatibility (EMC) for combined and/or
integrated equipment intended to be used within industrial locations.
The present document is only applicable to combined and/or integrated equipment where the radio function is within the
scope of one or more of the standards listed in clause 2.1.2 (covering references [1] to [8]) and where the non-radio
function is within the scope of one or more of the standards listed in clause 2.1.3 (covering references [9] to [50]).
Requirements applicable to the antenna port specifically related to the efficient use of radio spectrum are not included in
the present document.
NOTE: These requirements are generally found in the applicable product standard(s) for the effective use of the
radio spectrum.

Status
Published
Public Enquiry End Date
31-May-2019
Publication Date
09-Oct-2019
Technical Committee
MOC - Mobile Communications
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
07-Oct-2019
Due Date
12-Dec-2019
Completion Date
10-Oct-2019

Buy Documents

Standard

ETSI EN 303 446-2 V1.2.1 (2019-07) - ElectroMagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment; Part 2: Requirements for equipment intended to be used in industrial locations

English language (18 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 303 446-2 V1.2.1 (2019-10) - ElectroMagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment; Part 2: Requirements for equipment intended to be used in industrial locations

English language (18 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 303 446-2 V1.2.0 (2019-03) - ElectroMagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment; Part 2: Requirements for equipment intended to be used in industrial locations

English language (21 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

SIST EN 303 446-2 V1.2.1:2019

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

Overview

SIST EN 303 446-2 V1.2.1:2019 is a European standard that specifies electromagnetic compatibility (EMC) requirements for combined and/or integrated radio and non-radio equipment used in industrial locations. Published by SIST, this standard ensures that equipment operating in environments with high electrical noise and demanding power conditions meets minimum emission and immunity criteria, especially when both radio and non-radio functionalities are present together.

This standard is applicable only to equipment where:

  • The radio function falls within the scope of specific radio EMC standards.
  • The non-radio function falls within the scope of listed non-radio EMC standards.

Requirements for efficient radio spectrum use at antenna ports are not included; such requirements are covered by relevant product standards.

Key Topics

  • Electromagnetic Compatibility (EMC): Focuses on managing electromagnetic emissions and ensuring immunity to external electromagnetic disturbances.
  • Combined Radio and Non-Radio Equipment: Addresses special considerations for devices integrating both radio communications and non-radio operations within a single product or system.
  • Industrial Environments: Tailors requirements to address harsher electromagnetic environments typical of factories, processing plants, and similar industrial settings.
  • Emission and Immunity Requirements:
    • Radiated and conducted emissions
    • Immunity against phenomena such as electrostatic discharge, fast transients, surges, and voltage dips
  • Assessment and Testing: Outlines the need to configure equipment to maximize emissions and susceptibility during testing, and select appropriate test methods from referenced standards.

Applications

This EMC standard plays a critical role in ensuring reliable operation and regulatory compliance for combined and/or integrated industrial equipment. Typical applications include:

  • Industrial Automation Controllers: PLCs and automation systems that integrate wireless and wired communication.
  • Machine Tools & Robots: Equipment with embedded RF modules for control or monitoring.
  • Measurement & Monitoring Devices: Industrial sensors and instrumentation with data transmission features.
  • Building Automation: Systems combining networked control (e.g., via radio modules) with traditional electrical operation.
  • Process Control Equipment: Devices operating in high EMI environments requiring robust immunity.

Manufacturers, integrators, and installers use this standard to demonstrate that equipment:

  • Limits EMC emissions to acceptable levels for industrial environments,
  • Remains functional and safe under typical industrial electromagnetic disturbances,
  • Can be placed on the European market in compliance with relevant directives.

Related Standards

SIST EN 303 446-2 draws heavily on a comprehensive set of referenced standards for radio and non-radio functionalities:

  • Radio EMC standards (examples):
    • ETSI EN 301 489 series (covering common and specific radio equipment requirements)
  • Non-radio EMC standards (examples):
    • CENELEC EN 61000-6-2 & EN 61000-6-4 (generic EMC standards for industrial environments)
    • EN 55011 (industrial, scientific, and medical equipment)
    • EN 61326 (measurement, control and laboratory equipment)
    • EN 61131-2 (programmable controllers)

Additionally, the document references the ETSI EG 203 367 guide for multi-radio and combined equipment, ensuring alignment with directives like 2014/53/EU (RED) and 2014/30/EU (EMC Directive).

Industries and organizations utilizing equipment in challenging EMC settings should consider SIST EN 303 446-2 for product development, conformity assessment, and procurement to ensure high performance and legal compliance in industrial applications.

Buy Documents

Standard

ETSI EN 303 446-2 V1.2.1 (2019-07) - ElectroMagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment; Part 2: Requirements for equipment intended to be used in industrial locations

English language (18 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 303 446-2 V1.2.1 (2019-10) - ElectroMagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment; Part 2: Requirements for equipment intended to be used in industrial locations

English language (18 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 303 446-2 V1.2.0 (2019-03) - ElectroMagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment; Part 2: Requirements for equipment intended to be used in industrial locations

English language (21 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

SIST EN 303 446-2 V1.2.1:2019

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 303 446-2 V1.2.1:2019 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "ElectroMagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment - Part 2: Requirements for equipment intended to be used in industrial locations". This standard covers: The present document defines requirements in respect of ElectroMagnetic Compatibility (EMC) for combined and/or integrated equipment intended to be used within industrial locations. The present document is only applicable to combined and/or integrated equipment where the radio function is within the scope of one or more of the standards listed in clause 2.1.2 (covering references [1] to [8]) and where the non-radio function is within the scope of one or more of the standards listed in clause 2.1.3 (covering references [9] to [50]). Requirements applicable to the antenna port specifically related to the efficient use of radio spectrum are not included in the present document. NOTE: These requirements are generally found in the applicable product standard(s) for the effective use of the radio spectrum.

The present document defines requirements in respect of ElectroMagnetic Compatibility (EMC) for combined and/or integrated equipment intended to be used within industrial locations. The present document is only applicable to combined and/or integrated equipment where the radio function is within the scope of one or more of the standards listed in clause 2.1.2 (covering references [1] to [8]) and where the non-radio function is within the scope of one or more of the standards listed in clause 2.1.3 (covering references [9] to [50]). Requirements applicable to the antenna port specifically related to the efficient use of radio spectrum are not included in the present document. NOTE: These requirements are generally found in the applicable product standard(s) for the effective use of the radio spectrum.

SIST EN 303 446-2 V1.2.1:2019 is classified under the following ICS (International Classification for Standards) categories: 33.060.01 - Radiocommunications in general; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 303 446-2 V1.2.1:2019 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)

EUROPEAN STANDARD
ElectroMagnetic Compatibility (EMC)
standard for combined and/or integrated
radio and non-radio equipment;
Part 2: Requirements for equipment
intended to be used in industrial locations

2 Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)

Reference
REN/ERM-EMC-399
Keywords
EMC, emission, immunity
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2019.
All rights reserved.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its Members.

3GPP™ and LTE™ are trademarks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and
of the oneM2M Partners. ®
GSM and the GSM logo are trademarks registered and owned by the GSM Association.
ETSI
3 Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 4
Introduction . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.1.1 General . 6
2.1.2 Radio EMC standards . 6
2.1.3 Non-radio EMC standards . 7
2.1.4 Other EMC standards. 9
2.2 Informative references . 9
3 Definition of terms, symbols and abbreviations . 10
3.1 Terms . 10
3.2 Symbols . 12
3.3 Abbreviations . 12
4 EMC requirements . 12
4.1 Introduction . 12
4.2 Emissions requirements . 13
4.2.1 Radiated Emissions . 13
4.2.2 Conducted Emissions . 13
4.2.2.1 Special provisions . 13
4.2.2.2 AC Power port . 13
4.2.2.3 PLC port . 13
4.2.2.4 DC power port . 13
4.2.2.5 Wired network port . 14
4.2.2.6 Antenna Port . 14
4.3 Immunity requirements . 14
4.3.1 General . 14
4.3.2 Configuration of the equipment during immunity tests . 14
4.3.3 Performance criteria . 15
4.3.4 Radiated Immunity . 15
4.3.5 Electrostatic discharge . 15
4.3.6 Fast transients, common mode . 15
4.3.7 Radio frequency, common mode . 15
4.3.8 Voltage dips and interruptions . 16
4.3.9 Surges . 16
4.3.10 Other immunity tests . 16
Annex A (informative): Change History . 17
History . 18

ETSI
4 Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
Foreword
This final draft European Standard (EN) has been produced by ETSI Technical Committee Electromagnetic
compatibility and Radio spectrum Matters (ERM), and is now submitted for the Vote phase of the ETSI standards EN
Approval Procedure.
The present document is part 2 of a multi-part deliverable covering ElectroMagnetic Compatibility (EMC) for
combined and/or integrated equipment, as identified below:
Part 1: "Requirements for equipment intended to be used in residential, commercial and light industry locations";
Part 2: "Requirements for equipment intended to be used in industrial locations".

Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
5 Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)
Introduction
The present document is not intended for citation under any new approach Directive.
The present document is based on the principles given in ETSI EG 203 367 [i.3] "Guide to the application of
harmonised standards covering articles 3.1(b) and 3.2 of the Directive 2014/53/EU (RED) to multi-radio and combined
radio and non-radio equipment".
The present document contains the measurements, emission limits, immunity test levels and performance criteria that
are necessary for the assessment of a combination of a non-radio and a radio product in accordance with ETSI
EG 203 367 [i.3].
ETSI
6 Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)
1 Scope
The present document defines requirements in respect of ElectroMagnetic Compatibility (EMC) for combined and/or
integrated equipment intended to be used within industrial locations.
The present document is only applicable to combined and/or integrated equipment where the radio function is within the
scope of one or more of the standards listed in clause 2.1.2 (covering references [1] to [8]) and where the non-radio
function is within the scope of one or more of the standards listed in clause 2.1.3 (covering references [9] to [50]).
Requirements applicable to the antenna port specifically related to the efficient use of radio spectrum are not included in
the present document.
NOTE: These requirements are generally found in the applicable product standard(s) for the effective use of the
radio spectrum.
2 References
2.1 Normative references
2.1.1 General
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
In addition, within the present document, some references are non-specific. The applicable version listed in the OJEU
under the Directives 2014/53/EU [i.1] or 2014/30/EU [i.2] may be used.
NOTE 2: Before the date of withdrawal, a preceding version may be used (see clause 2.4 of the Technical Working
Procedures in the ETSI Directives).
2.1.2 Radio EMC standards
[1] ETSI EN 301 489-1: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 1: Common technical requirements; Harmonised Standard for Electromagnetic
Compatibility".
[2] ETSI EN 301 489-3: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies
between 9 kHz and 246 GHz; Harmonised Standard covering the essential requirements of
article 3.1(b) of Directive 2014/53/EU".
[3] ETSI EN 301 489-5: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment
(speech and non-speech) and Terrestrial Trunked Radio (TETRA); Harmonised Standard covering
the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[4] ETSI EN 301 489-6: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 6: Specific conditions for Digital Enhanced Cordless Telecommunications (DECT)
equipment; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive
2014/53/EU".
ETSI
7 Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)
[5] ETSI EN 301 489-17: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonised
Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[6] ETSI EN 301 489-19: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating
in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS
band (ROGNSS) providing positioning, navigation, and timing data; Harmonised Standard
covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[7] ETSI EN 301 489-33: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 33: Specific conditions for Ultra-WideBand (UWB) devices; Harmonised Standard
covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[8] ETSI EN 301 489-51: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 51: Specific conditions for Automotive, Ground based Vehicles and Surveillance
Radar Devices using 24,05 GHz to 24,25 GHz, 24,05 GHz to 24,5 GHz, 76 GHz to 77 GHz and
77 GHz to 81 GHz; Harmonised Standard covering the essential requirements of article 3.1(b) of
Directive 2014/53/EU".
2.1.3 Non-radio EMC standards
[9] CENELEC EN 50121-3-2: "Railway applications - Electromagnetic compatibility - Part 3-2:
Rolling stock - Apparatus".
[10] CENELEC EN 50121-4: "Railway applications - Electromagnetic compatibility - Part 4: Emission
and immunity of the signalling and telecommunications apparatus".
[11] CENELEC EN 50121-5: "Railway applications - Electromagnetic compatibility - Part 5: Emission
and immunity of fixed power supply installations and apparatus".
[12] CENELEC EN 50270: "Electromagnetic compatibility - Electrical apparatus for the detection and
measurement of combustible gases, toxic gases or oxygen".
[13] CENELEC EN 50293: "Road traffic signal systems - Electromagnetic compatibility".
[14] CENELEC EN 50370-1: "Electromagnetic compatibility (EMC) - Product family standard for
machine tools - Part 1: Emission".
[15] CENELEC EN 50370-2: "Electromagnetic compatibility (EMC) - Product family standard for
machine tools - Part 2: Immunity".
[16] CENELEC EN 50491-5-1: "General requirements for Home and Building Electronic Systems
(HBES) and Building Automation and Control Systems (BACS) - Part 5-1: EMC requirements,
conditions and test set-up".
[17] CENELEC EN 50491-5-3: "General requirements for Home and Building Electronic Systems
(HBES) and Building Automation and Control Systems (BACS) - Part 5-3: EMC requirements for
HBES/BACS used in industry environment".
[18] CENELEC EN 55011: "Industrial, scientific and medical equipment - Radio-frequency
disturbance characteristics - Limits and methods of measurement".
[19] CENELEC EN 55015: "Limits and methods of measurement of radio disturbance characteristics of
electrical lighting and similar equipment".
[20] CENELEC EN 60730-1: "Automatic electrical controls - Part 1: General requirements".
[21] CENELEC EN 60947-1: "Low-voltage switchgear and controlgear - Part 1: General rules".
[22] CENELEC EN 60947-2: "Low-voltage switchgear and controlgear - Part 2: Circuit-breakers".
[23] CENELEC EN 60947-3: "Low-voltage switchgear and controlgear - Part 3: Switches,
disconnectors, switch-disconnectors and fuse-combination units".
ETSI
8 Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)
[24] CENELEC EN 60947-4-1: "Low-voltage switchgear and controlgear - Part 4-1: Contactors and
motor-starters - Electromechanical contactors and motor-starters".
[25] CENELEC EN 60947-4-2: "Low-voltage switchgear and controlgear - Part 4-2: Contactors and
motor-starters - AC semiconductor motor controllers and starters".
[26] CENELEC EN 60947-4-3: "Low-voltage switchgear and controlgear - Part 4-3: Contactors and
motor-starters - AC semiconductor controllers and contactors for non-motor loads".
[27] CENELEC EN 60947-5-1: "Low-voltage switchgear and controlgear - Part 5-1: Control circuit
devices and switching elements - Electromechanical control circuit devices".
[28] CENELEC EN 60947-5-2: "Low-voltage switchgear and controlgear - Part 5-2: Control circuit
devices and switching elements - Proximity switches".
[29] CENELEC EN 60947-5-6: "Low-voltage switchgear and controlgear - Part 5-6: Control circuit
devices and switching elements - DC interface for proximity sensors and switching amplifiers
(NAMUR)".
[30] CENELEC EN 60947-5-7: "Low-voltage switchgear and controlgear - Part 5-7: Control circuit
devices and switching elements - Requirements for proximity devices with analogue output".
[31] CENELEC EN 60947-5-9: "Low-voltage switchgear and controlgear - Part 5-9: Control circuit
devices and switching elements - Flow rate switches".
[32] CENELEC EN 60947-6-1: "Low-voltage switchgear and controlgear - Part 6-1: Multiple function
equipment - Transfer switching equipment".
[33] CENELEC EN 60947-6-2: "Low-voltage switchgear and controlgear - Part 6-2: Multiple function
equipment - Control and protective switching devices (or equipment) (CPS)".
[34] CENELEC EN 60947-8: "Low-voltage switchgear and controlgear - Part 8: Control units for
built-in thermal protection (PTC) for rotating electrical machines".
[35] CENELEC EN 60974-10: "Arc welding equipment - Part 10: Electromagnetic compatibility
(EMC) requirements".
[36] CENELEC EN 61000-6-2: "Electromagnetic compatibility (EMC) - Part 6-2: Generic standards -
Immunity standard for industrial environments".
[37] CENELEC EN 61000-6-4: "Electromagnetic compatibility (EMC) - Part 6-4: Generic standards -
Emission standard for industrial environments".
[38] CENELEC EN 61131-2: "Programmable controllers - Part 2: Equipment requirements and tests".
[39] CENELEC EN 61204-3: "Low voltage power supplies, d.c. output - Part 3: Electromagnetic
compatibility (EMC)".
[40] CENELEC EN 61326-1: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 1: General requirements".
[41] CENELEC EN 61326-2-2: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions
and performance criteria for portable test, measuring and monitoring equipment used in low-
voltage distribution systems".
[42] CENELEC EN 61326-2-3: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions
and performance criteria for transducers with integrated or remote signal conditioning".
[43] CENELEC EN 61326-2-4: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions
and performance criteria for insulation monitoring devices according to IEC 61557-8 and for
equipment for insulation fault location according to IEC 61557-9".
ETSI
9 Final draft ETSI EN 303 446-2 V1.2.1 (2019-07)
[44] CENELEC EN 61326-2-5: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions
and performance criteria for devices with field bus interfaces according to IEC 61784-1".
[45] CENELEC EN 61439-2: "Low-voltage switchgear and controlgear assemblies - Part 2: Power
switchgear and controlgear assemblies".
[46] CENELEC EN 61439-3: "Low-voltage switchgear and controlgear assemblies - Part 3:
Distribution boards intended to be operated by ordinary persons (DBO)".
[47] CENELEC EN 61557-12: "Electrical safety in low voltage distribution systems up to 1 000 V a.c.
and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -
Part 12: Performance measuring and monitoring devices (PMD)".
[48] CENELEC EN 61800-3: "Adjustable speed ele
...


EUROPEAN STANDARD
ElectroMagnetic Compatibility (EMC)
standard for combined and/or integrated
radio and non-radio equipment;
Part 2: Requirements for equipment
intended to be used in industrial locations

2 ETSI EN 303 446-2 V1.2.1 (2019-10)

Reference
REN/ERM-EMC-399
Keywords
EMC, emission, immunity
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2019.
All rights reserved.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its Members.

3GPP™ and LTE™ are trademarks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and
of the oneM2M Partners. ®
GSM and the GSM logo are trademarks registered and owned by the GSM Association.
ETSI
3 ETSI EN 303 446-2 V1.2.1 (2019-10)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 4
Introduction . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.1.1 General . 6
2.1.2 Radio EMC standards . 6
2.1.3 Non-radio EMC standards . 7
2.1.4 Other EMC standards. 9
2.2 Informative references . 9
3 Definition of terms, symbols and abbreviations . 10
3.1 Terms . 10
3.2 Symbols . 12
3.3 Abbreviations . 12
4 EMC requirements . 12
4.1 Introduction . 12
4.2 Emissions requirements . 13
4.2.1 Radiated Emissions . 13
4.2.2 Conducted Emissions . 13
4.2.2.1 Special provisions . 13
4.2.2.2 AC Power port . 13
4.2.2.3 PLC port . 13
4.2.2.4 DC power port . 13
4.2.2.5 Wired network port . 14
4.2.2.6 Antenna Port . 14
4.3 Immunity requirements . 14
4.3.1 General . 14
4.3.2 Configuration of the equipment during immunity tests . 14
4.3.3 Performance criteria . 15
4.3.4 Radiated Immunity . 15
4.3.5 Electrostatic discharge . 15
4.3.6 Fast transients, common mode . 15
4.3.7 Radio frequency, common mode . 15
4.3.8 Voltage dips and interruptions . 16
4.3.9 Surges . 16
4.3.10 Other immunity tests . 16
Annex A (informative): Change History . 17
History . 18

ETSI
4 ETSI EN 303 446-2 V1.2.1 (2019-10)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Electromagnetic compatibility and
Radio spectrum Matters (ERM).
The present document is part 2 of a multi-part deliverable covering ElectroMagnetic Compatibility (EMC) for
combined and/or integrated equipment, as identified below:
Part 1: "Requirements for equipment intended to be used in residential, commercial and light industry locations";
Part 2: "Requirements for equipment intended to be used in industrial locations".

National transposition dates
Date of adoption of this EN: 20 September 2019
Date of latest announcement of this EN (doa): 31 December 2019
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 30 June 2020
Date of withdrawal of any conflicting National Standard (dow): 30 June 2020

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
5 ETSI EN 303 446-2 V1.2.1 (2019-10)
Introduction
The present document is not intended for citation under any new approach Directive.
The present document is based on the principles given in ETSI EG 203 367 [i.3] "Guide to the application of
harmonised standards covering articles 3.1(b) and 3.2 of the Directive 2014/53/EU (RED) to multi-radio and combined
radio and non-radio equipment".
The present document contains the measurements, emission limits, immunity test levels and performance criteria that
are necessary for the assessment of a combination of a non-radio and a radio product in accordance with ETSI
EG 203 367 [i.3].
ETSI
6 ETSI EN 303 446-2 V1.2.1 (2019-10)
1 Scope
The present document defines requirements in respect of ElectroMagnetic Compatibility (EMC) for combined and/or
integrated equipment intended to be used within industrial locations.
The present document is only applicable to combined and/or integrated equipment where the radio function is within the
scope of one or more of the standards listed in clause 2.1.2 (covering references [1] to [8]) and where the non-radio
function is within the scope of one or more of the standards listed in clause 2.1.3 (covering references [9] to [50]).
Requirements applicable to the antenna port specifically related to the efficient use of radio spectrum are not included in
the present document.
NOTE: These requirements are generally found in the applicable product standard(s) for the effective use of the
radio spectrum.
2 References
2.1 Normative references
2.1.1 General
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
In addition, within the present document, some references are non-specific. The applicable version listed in the OJEU
under the Directives 2014/53/EU [i.1] or 2014/30/EU [i.2] may be used.
NOTE 2: Before the date of withdrawal, a preceding version may be used (see clause 2.4 of the Technical Working
Procedures in the ETSI Directives).
2.1.2 Radio EMC standards
[1] ETSI EN 301 489-1: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 1: Common technical requirements; Harmonised Standard for Electromagnetic
Compatibility".
[2] ETSI EN 301 489-3: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies
between 9 kHz and 246 GHz; Harmonised Standard covering the essential requirements of
article 3.1(b) of Directive 2014/53/EU".
[3] ETSI EN 301 489-5: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment
(speech and non-speech) and Terrestrial Trunked Radio (TETRA); Harmonised Standard covering
the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[4] ETSI EN 301 489-6: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 6: Specific conditions for Digital Enhanced Cordless Telecommunications (DECT)
equipment; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive
2014/53/EU".
ETSI
7 ETSI EN 303 446-2 V1.2.1 (2019-10)
[5] ETSI EN 301 489-17: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonised
Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[6] ETSI EN 301 489-19: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating
in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS
band (ROGNSS) providing positioning, navigation, and timing data; Harmonised Standard
covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[7] ETSI EN 301 489-33: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 33: Specific conditions for Ultra-WideBand (UWB) devices; Harmonised Standard
covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[8] ETSI EN 301 489-51: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 51: Specific conditions for Automotive, Ground based Vehicles and Surveillance
Radar Devices using 24,05 GHz to 24,25 GHz, 24,05 GHz to 24,5 GHz, 76 GHz to 77 GHz and
77 GHz to 81 GHz; Harmonised Standard covering the essential requirements of article 3.1(b) of
Directive 2014/53/EU".
2.1.3 Non-radio EMC standards
[9] CENELEC EN 50121-3-2: "Railway applications - Electromagnetic compatibility - Part 3-2:
Rolling stock - Apparatus".
[10] CENELEC EN 50121-4: "Railway applications - Electromagnetic compatibility - Part 4: Emission
and immunity of the signalling and telecommunications apparatus".
[11] CENELEC EN 50121-5: "Railway applications - Electromagnetic compatibility - Part 5: Emission
and immunity of fixed power supply installations and apparatus".
[12] CENELEC EN 50270: "Electromagnetic compatibility - Electrical apparatus for the detection and
measurement of combustible gases, toxic gases or oxygen".
[13] CENELEC EN 50293: "Road traffic signal systems - Electromagnetic compatibility".
[14] CENELEC EN 50370-1: "Electromagnetic compatibility (EMC) - Product family standard for
machine tools - Part 1: Emission".
[15] CENELEC EN 50370-2: "Electromagnetic compatibility (EMC) - Product family standard for
machine tools - Part 2: Immunity".
[16] CENELEC EN 50491-5-1: "General requirements for Home and Building Electronic Systems
(HBES) and Building Automation and Control Systems (BACS) - Part 5-1: EMC requirements,
conditions and test set-up".
[17] CENELEC EN 50491-5-3: "General requirements for Home and Building Electronic Systems
(HBES) and Building Automation and Control Systems (BACS) - Part 5-3: EMC requirements for
HBES/BACS used in industry environment".
[18] CENELEC EN 55011: "Industrial, scientific and medical equipment - Radio-frequency
disturbance characteristics - Limits and methods of measurement".
[19] CENELEC EN 55015: "Limits and methods of measurement of radio disturbance characteristics of
electrical lighting and similar equipment".
[20] CENELEC EN 60730-1: "Automatic electrical controls - Part 1: General requirements".
[21] CENELEC EN 60947-1: "Low-voltage switchgear and controlgear - Part 1: General rules".
[22] CENELEC EN 60947-2: "Low-voltage switchgear and controlgear - Part 2: Circuit-breakers".
[23] CENELEC EN 60947-3: "Low-voltage switchgear and controlgear - Part 3: Switches,
disconnectors, switch-disconnectors and fuse-combination units".
ETSI
8 ETSI EN 303 446-2 V1.2.1 (2019-10)
[24] CENELEC EN 60947-4-1: "Low-voltage switchgear and controlgear - Part 4-1: Contactors and
motor-starters - Electromechanical contactors and motor-starters".
[25] CENELEC EN 60947-4-2: "Low-voltage switchgear and controlgear - Part 4-2: Contactors and
motor-starters - AC semiconductor motor controllers and starters".
[26] CENELEC EN 60947-4-3: "Low-voltage switchgear and controlgear - Part 4-3: Contactors and
motor-starters - AC semiconductor controllers and contactors for non-motor loads".
[27] CENELEC EN 60947-5-1: "Low-voltage switchgear and controlgear - Part 5-1: Control circuit
devices and switching elements - Electromechanical control circuit devices".
[28] CENELEC EN 60947-5-2: "Low-voltage switchgear and controlgear - Part 5-2: Control circuit
devices and switching elements - Proximity switches".
[29] CENELEC EN 60947-5-6: "Low-voltage switchgear and controlgear - Part 5-6: Control circuit
devices and switching elements - DC interface for proximity sensors and switching amplifiers
(NAMUR)".
[30] CENELEC EN 60947-5-7: "Low-voltage switchgear and controlgear - Part 5-7: Control circuit
devices and switching elements - Requirements for proximity devices with analogue output".
[31] CENELEC EN 60947-5-9: "Low-voltage switchgear and controlgear - Part 5-9: Control circuit
devices and switching elements - Flow rate switches".
[32] CENELEC EN 60947-6-1: "Low-voltage switchgear and controlgear - Part 6-1: Multiple function
equipment - Transfer switching equipment".
[33] CENELEC EN 60947-6-2: "Low-voltage switchgear and controlgear - Part 6-2: Multiple function
equipment - Control and protective switching devices (or equipment) (CPS)".
[34] CENELEC EN 60947-8: "Low-voltage switchgear and controlgear - Part 8: Control units for
built-in thermal protection (PTC) for rotating electrical machines".
[35] CENELEC EN 60974-10: "Arc welding equipment - Part 10: Electromagnetic compatibility
(EMC) requirements".
[36] CENELEC EN 61000-6-2: "Electromagnetic compatibility (EMC) - Part 6-2: Generic standards -
Immunity standard for industrial environments".
[37] CENELEC EN 61000-6-4: "Electromagnetic compatibility (EMC) - Part 6-4: Generic standards -
Emission standard for industrial environments".
[38] CENELEC EN 61131-2: "Programmable controllers - Part 2: Equipment requirements and tests".
[39] CENELEC EN 61204-3: "Low voltage power supplies, d.c. output - Part 3: Electromagnetic
compatibility (EMC)".
[40] CENELEC EN 61326-1: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 1: General requirements".
[41] CENELEC EN 61326-2-2: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions
and performance criteria for portable test, measuring and monitoring equipment used in low-
voltage distribution systems".
[42] CENELEC EN 61326-2-3: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions
and performance criteria for transducers with integrated or remote signal conditioning".
[43] CENELEC EN 61326-2-4: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions
and performance criteria for insulation monitoring devices according to IEC 61557-8 and for
equipment for insulation fault location according to IEC 61557-9".
ETSI
9 ETSI EN 303 446-2 V1.2.1 (2019-10)
[44] CENELEC EN 61326-2-5: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions
and performance criteria for devices with field bus interfaces according to IEC 61784-1".
[45] CENELEC EN 61439-2: "Low-voltage switchgear and controlgear assemblies - Part 2: Power
switchgear and controlgear assemblies".
[46] CENELEC EN 61439-3: "Low-voltage switchgear and controlgear assemblies - Part 3:
Distribution boards intended to be operated by ordinary persons (DBO)".
[47] CENELEC EN 61557-12: "Electrical safety in low voltage distribution systems up to 1 000 V a.c.
and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -
Part 12: Performance measuring and monitoring devices (PMD)".
[48] CENELEC EN 61800-3: "Adjustable speed electrical power drive systems - Part 3: EMC
requirements and specif
...


Draft ETSI EN 303 446-2 V1.2.0 (2019-03)

EUROPEAN STANDARD
ElectroMagnetic Compatibility (EMC)
standard for combined and/or integrated
radio and non-radio equipment;
Part 2: Requirements for equipment
intended to be used in industrial locations

2 Draft ETSI EN 303 446-2 V1.2.0 (2019-03)

Reference
REN/ERM-EMC-399
Keywords
EMC, emission, immunity
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2019.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are trademarks of ETSI registered for the benefit of its Members.
TM TM
3GPP and LTE are trademarks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and
of the oneM2M Partners. ®
GSM and the GSM logo are trademarks registered and owned by the GSM Association.
ETSI
3 Draft ETSI EN 303 446-2 V1.2.0 (2019-03)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 4
Introduction . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.1.1 General . 6
2.1.2 Radio EMC standards . 6
2.1.3 Non-radio EMC standards . 7
2.1.4 Other EMC standards. 9
2.2 Informative references . 9
3 Definition of terms, symbols and abbreviations . 10
3.1 Terms . 10
3.2 Symbols . 12
3.3 Abbreviations . 12
4 EMC requirements . 12
4.1 Introduction . 12
4.2 Emissions requirements . 13
4.2.1 Radiated Emissions . 13
4.2.2 Conducted Emissions . 13
4.2.2.1 Special provisions . 13
4.2.2.2 AC Power port . 13
4.2.2.3 PLC port . 13
4.2.2.4 DC power port . 14
4.2.2.5 Wired network port . 14
4.2.2.6 Antenna Port . 14
4.3 Immunity requirements . 14
4.3.1 General . 14
4.3.2 Configuration of the equipment during immunity tests . 14
4.3.3 Performance criteria . 15
4.3.4 Radiated Immunity . 15
4.3.5 Electrostatic discharge . 15
4.3.6 Fast transients, common mode . 15
4.3.7 Radio frequency, common mode . 15
4.3.8 Voltage dips and interruptions . 16
4.3.9 Surges . 16
4.3.10 Other immunity tests . 16
Annex A (informative): Guidance for the choice of configurations for the measurements on
combined equipment. 17
Annex B (informative): Use of industrial equipment in residential locations . 18
Annex C (informative): Exclusion bands. 19
Annex D (informative): Change History . 20
History . 21

ETSI
4 Draft ETSI EN 303 446-2 V1.2.0 (2019-03)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Electromagnetic compatibility
and Radio spectrum Matters (ERM), and is now submitted for the combined Public Enquiry and Vote phase of the ETSI
standards EN Approval Procedure.
The present document is part 2 of a multi-part deliverable covering ElectroMagnetic Compatibility (EMC) for
combined and/or integrated equipment, as identified below:
Part 1: "Requirements for equipment intended to be used in residential, commercial and light industry locations";
Part 2: "Requirements for equipment intended to be used in industrial locations".

Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
5 Draft ETSI EN 303 446-2 V1.2.0 (2019-03)
Introduction
The present document is not intended for citation under any new approach Directive.
The present document is based on the principles given in ETSI EG 203 367 [i.3] "Guide to the application of
harmonised standards covering articles 3.1(b) and 3.2 of the Directive 2014/53/EU (RED) to multi-radio and combined
radio and non-radio equipment".
The present document contains the measurements, emission limits and performance criteria that are necessary for the
Δ" in ETSI EG 203 367 [i.3]).
assessment of a combination of a non-radio and a radio product (which is called "

ETSI
6 Draft ETSI EN 303 446-2 V1.2.0 (2019-03)
1 Scope
The present document defines requirements in respect of ElectroMagnetic Compatibility (EMC) for combined and/or
integrated equipment intended to be used within industrial locations.
The present document is only applicable to combined and/or integrated equipment where the radio function is within the
scope of one or more of the standards listed in clause 2.1.2 (covering references [1] to [8]) and where the non-radio
function is within the scope of one or more of the standards listed in clause 2.1.3 (covering references [9] to [50]).
Requirements applicable to the antenna port specifically related to the efficient use of radio spectrum are not included in
the present document.
NOTE: These requirements are generally found in the applicable product standard(s) for the effective use of the
radio spectrum.
2 References
2.1 Normative references
2.1.1 General
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
In addition, within the present document, some references are non-specific. The applicable version listed in the OJEU
under the Directives 2014/53/EU [i.1] or 2014/30/EU [i.2] may be used.
NOTE 2: Before the date of withdrawal, a preceding version may be used (see clause 2.4 of the Technical Working
Procedures in the ETSI Directives).
2.1.2 Radio EMC standards
[1] ETSI EN 301 489-1: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 1: Common technical requirements; Harmonised Standard covering the essential
requirements of article 3.1(b) of Directive 2014/53/EU and the essential requirements of article 6
of Directive 2014/30/EU".
[2] ETSI EN 301 489-3: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies
between 9 kHz and 246 GHz; Harmonised Standard covering the essential requirements of
article 3.1(b) of Directive 2014/53/EU".
[3] ETSI EN 301 489-5: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment
(speech and non-speech) and Terrestrial Trunked Radio (TETRA); Harmonised Standard covering
the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[4] ETSI EN 301 489-6: "Electromagnetic compatibility and Radio spectrum Matters (ERM);
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 6: Specific
conditions for Digital Enhanced Cordless Telecommunications (DECT) equipment".
ETSI
7 Draft ETSI EN 303 446-2 V1.2.0 (2019-03)
[5] ETSI EN 301 489-17: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonised
Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[6] ETSI EN 301 489-19: "Electromagnetic compatibility and Radio spectrum Matters (ERM);
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 19:
Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz
band providing data communications".
[7] ETSI EN 301 489-33: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 33: Specific conditions for Ultra-WideBand (UWB) devices; Harmonised Standard
covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[8] ETSI EN 301 489-51: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 51: Specific conditions for Automotive, Ground based Vehicles and Surveillance
Radar Devices using 24,05 GHz to 24,25 GHz, 24,05 GHz to 24,5 GHz, 76 GHz to 77 GHz and
77 GHz to 81 GHz; Harmonised Standard covering the essential requirements of article 3.1b of
Directive 2014/53/EU".
2.1.3 Non-radio EMC standards
[9] CENELEC EN 50121-3-2: "Railway applications - Electromagnetic compatibility - Part 3-2:
Rolling stock - Apparatus".
[10] CENELEC EN 50121-4: "Railway applications - Electromagnetic compatibility - Part 4: Emission
and immunity of the signalling and telecommunications apparatus".
[11] CENELEC EN 50121-5: "Railway applications - Electromagnetic compatibility - Part 5: Emission
and immunity of fixed power supply installations and apparatus".
[12] CENELEC EN 50270: "Electromagnetic compatibility. Electrical apparatus for the detection and
measurement of combustible gases, toxic gases or oxygen".
[13] CENELEC EN 50293: "Road traffic signal systems - Electromagnetic compatibility".
[14] CENELEC EN 50370-1: "Electromagnetic compatibility (EMC) - Product family standard for
machine tools - Part 1: Emission".
[15] CENELEC EN 50370-2: "Electromagnetic compatibility (EMC) - Product family standard for
machine tools - Part 2: Immunity".
[16] CENELEC EN 50491-5-1: "General requirements for Home and Building Electronic Systems
(HBES) and Building Automation and Control Systems (BACS) - Part 5-1: EMC requirements,
conditions and test set-up".
[17] CENELEC EN 50491-5-3: "General requirements for Home and Building Electronic Systems
(HBES) and Building Automation and Control Systems (BACS) - Part 5-3: EMC requirements for
HBES/BACS used in industry environment".
[18] CENELEC EN 55011: "Industrial, scientific and medical equipment. Radio-frequency disturbance
characteristics. Limits and methods of measurement".
[19] CENELEC EN 55015: "Limits and methods of measurement of radio disturbance characteristics of
electrical lighting and similar equipment".
[20] CENELEC EN 60730-1: "Automatic electrical controls - Part 1: General requirements".
[21] CENELEC EN 60947-1: "Low-voltage switchgear and controlgear - Part 1: General rules".
[22] CENELEC EN 60947-2: "Low-voltage switchgear and controlgear - Part 2: Circuit-breakers".
[23] CENELEC EN 60947-3: "Low-voltage switchgear and controlgear - Part 3: Switches,
disconnectors, switch-disconnectors and fuse-combination units".
ETSI
8 Draft ETSI EN 303 446-2 V1.2.0 (2019-03)
[24] CENELEC EN 60947-4-1: "Low-voltage switchgear and controlgear - Part 4-1: Contactors and
motor-starters - Electromechanical contactors and motor-starters".
[25] CENELEC EN 60947-4-2: "Low-voltage switchgear and controlgear - Part 4-2: Contactors and
motor-starters - AC semiconductor motor controllers and starters".
[26] CENELEC EN 60947-4-3: "Low-voltage switchgear and controlgear - Part 4-3: Contactors and
motor-starters - AC semiconductor controllers and contactors for non-motor loads".
[27] CENELEC EN 60947-5-1: "Low-voltage switchgear and controlgear - Part 5-1: Control circuit
devices and switching elements - Electromechanical control circuit devices".
[28] CENELEC EN 60947-5-2: "Low-voltage switchgear and controlgear - Part 5-2: Control circuit
devices and switching elements - Proximity switches".
[29] CENELEC EN 60947-5-6: "Low-voltage switchgear and controlgear - Part 5-6: Control circuit
devices and switching elements - DC interface for proximity sensors and switching amplifiers
(NAMUR)".
[30] CENELEC EN 60947-5-7: "Low-voltage switchgear and controlgear - Part 5-7: Control circuit
devices and switching elements - Requirements for proximity devices with analogue output".
[31] CENELEC EN 60947-5-9: "Low-voltage switchgear and controlgear - Part 5-9: Control circuit
devices and switching elements - Flow rate switches".
[32] CENELEC EN 60947-6-1: "Low-voltage switchgear and controlgear - Part 6-1: Multiple function
equipment - Transfer switching equipment".
[33] CENELEC EN 60947-6-2: "Low-voltage switchgear and controlgear - Part 6-2: Multiple function
equipment - Control and protective switching devices (or equipment) (CPS)".
[34] CENELEC EN 60947-8: "Low-voltage switchgear and controlgear - Part 8: Control units for built-
in thermal protection (PTC) for rotating electrical machines".
[35] CENELEC EN 60974-10: "Arc welding equipment - Part 10: Electromagnetic compatibility
(EMC) requirements".
[36] CENELEC EN 61000-6-2: "Electromagnetic compatibility (EMC) - Part 6-2: Generic standards -
Immunity standard for industrial environments".
[37] CENELEC EN 61000-6-4: "Electromagnetic compatibility (EMC) - Part 6-4: Generic standards -
Emission standard for industrial environments".
[38] CENELEC EN 61131-2: "Programmable controllers - Part 2: Equipment requirements and tests".
[39] CENELEC EN 61204-3: "Low voltage power supplies, d.c. output - Part 3: Electromagnetic
compatibility (EMC)".
[40] CENELEC EN 61326-1: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 1: General requirements".
[41] CENELEC EN 61326-2-2: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions
and performance criteria for portable test, measuring and monitoring equipment used in low-
voltage distribution systems".
[42] CENELEC EN 61326-2-3: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions
and performance criteria for transducers with integrated or remote signal conditioning".
[43] CENELEC EN 61326-2-4: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions
and performance criteria for insulation monitoring devices according to IEC 61557-8 and for
equipment for insulation fault location according to IEC 61557-9".
ETSI
9 Draft ETSI EN 303 446-2 V1.2.0 (2019-03)
[44] CENELEC EN 61326-2-5: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions
and performance criteria for devices with field bus interfaces according to IEC 61784-1".
[45] CENELEC EN 61439-2: "Low-voltage switchgear and controlgear assemblies - Part 2: Power
switchgear and controlgear assemblies".
[46] CENELEC EN 61439-3: "Low-voltage switchgear and controlgear assemblies - Part 3:
Distribution boards intended to be operated by ordinary persons (DBO)".
[47] CENELEC EN 61557-12: "Electrical safety in low voltage distribution systems up to 1 000 V a.c.
and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -
Part 12: Performance measuring and monitoring devices (PMD)".
[48] CENELEC EN 61800-3: "Adjustable speed electrical power drive systems - Part 3: EMC
requirements and specific test methods".
[49] CENELEC EN 62135-2: "Resistance welding equipment - Part 2: Electromagnetic compatibility
(EMC) requirements".
[50] ETSI EN 300 386: "Telecommunication network equipment; ElectroMagnetic Compatibility
(EMC) requirements; Harmonised Standard covering the essential requirements of the Directive
2014/30/EU".
2.1.4 Other EMC standards
[51] CENELEC EN 55032 (2015) and AC (2016): "Electromagnetic compatibility of multimedia
equipment - Emission requirements".
[52] CENELEC EN 50561-1 (2013) and AC (2015): "Power line communication apparatus used in
low-voltage installations - Radio disturbance characteristics - Limits and methods of measurement
- Part 1: Apparatus for in-home use".
[53] CENELEC EN 50561-3 (2016): "Power line communication apparatus used in low-voltage
installations - Radio disturbance characteristics - Limits and methods of measurement - Part 3:
Apparatus operating above 30 MHz".
[54] CENELEC EN 61000-6-4 (2007) and A1 (2011): "Electromagnetic compatibility (EMC) -
Part 6-4: Generic standards - Emission standard for industrial environments".
NOTE: The standards referenced in clause 2.1.4 do not directly fall into the scope of the present document. They
are only referenced in the sense of a basic standard for a specific measurement.
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] Directi
...


SLOVENSKI STANDARD
01-december-2019
Standard elektromagnetne združljivosti (EMC) za kombinirano in/ali integrirano
radijsko in neradijsko opremo - 2. del: Zahteve za opremo, ki je namenjena za
uporabo v industriji
ElectroMagnetic Compatibility (EMC) standard for combined and/or integrated radio and
non-radio equipment - Part 2: Requirements for equipment intended to be used in
industrial locations
Ta slovenski standard je istoveten z: ETSI EN 303 446-2 V1.2.1 (2019-10)
ICS:
33.060.01 Radijske komunikacije na Radiocommunications in
splošno general
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
ElectroMagnetic Compatibility (EMC)
standard for combined and/or integrated
radio and non-radio equipment;
Part 2: Requirements for equipment
intended to be used in industrial locations

2 ETSI EN 303 446-2 V1.2.1 (2019-10)

Reference
REN/ERM-EMC-399
Keywords
EMC, emission, immunity
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2019.
All rights reserved.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its Members.

3GPP™ and LTE™ are trademarks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and
of the oneM2M Partners. ®
GSM and the GSM logo are trademarks registered and owned by the GSM Association.
ETSI
3 ETSI EN 303 446-2 V1.2.1 (2019-10)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 4
Introduction . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.1.1 General . 6
2.1.2 Radio EMC standards . 6
2.1.3 Non-radio EMC standards . 7
2.1.4 Other EMC standards. 9
2.2 Informative references . 9
3 Definition of terms, symbols and abbreviations . 10
3.1 Terms . 10
3.2 Symbols . 12
3.3 Abbreviations . 12
4 EMC requirements . 12
4.1 Introduction . 12
4.2 Emissions requirements . 13
4.2.1 Radiated Emissions . 13
4.2.2 Conducted Emissions . 13
4.2.2.1 Special provisions . 13
4.2.2.2 AC Power port . 13
4.2.2.3 PLC port . 13
4.2.2.4 DC power port . 13
4.2.2.5 Wired network port . 14
4.2.2.6 Antenna Port . 14
4.3 Immunity requirements . 14
4.3.1 General . 14
4.3.2 Configuration of the equipment during immunity tests . 14
4.3.3 Performance criteria . 15
4.3.4 Radiated Immunity . 15
4.3.5 Electrostatic discharge . 15
4.3.6 Fast transients, common mode . 15
4.3.7 Radio frequency, common mode . 15
4.3.8 Voltage dips and interruptions . 16
4.3.9 Surges . 16
4.3.10 Other immunity tests . 16
Annex A (informative): Change History . 17
History . 18

ETSI
4 ETSI EN 303 446-2 V1.2.1 (2019-10)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Electromagnetic compatibility and
Radio spectrum Matters (ERM).
The present document is part 2 of a multi-part deliverable covering ElectroMagnetic Compatibility (EMC) for
combined and/or integrated equipment, as identified below:
Part 1: "Requirements for equipment intended to be used in residential, commercial and light industry locations";
Part 2: "Requirements for equipment intended to be used in industrial locations".

National transposition dates
Date of adoption of this EN: 20 September 2019
Date of latest announcement of this EN (doa): 31 December 2019
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 30 June 2020
Date of withdrawal of any conflicting National Standard (dow): 30 June 2020

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
5 ETSI EN 303 446-2 V1.2.1 (2019-10)
Introduction
The present document is not intended for citation under any new approach Directive.
The present document is based on the principles given in ETSI EG 203 367 [i.3] "Guide to the application of
harmonised standards covering articles 3.1(b) and 3.2 of the Directive 2014/53/EU (RED) to multi-radio and combined
radio and non-radio equipment".
The present document contains the measurements, emission limits, immunity test levels and performance criteria that
are necessary for the assessment of a combination of a non-radio and a radio product in accordance with ETSI
EG 203 367 [i.3].
ETSI
6 ETSI EN 303 446-2 V1.2.1 (2019-10)
1 Scope
The present document defines requirements in respect of ElectroMagnetic Compatibility (EMC) for combined and/or
integrated equipment intended to be used within industrial locations.
The present document is only applicable to combined and/or integrated equipment where the radio function is within the
scope of one or more of the standards listed in clause 2.1.2 (covering references [1] to [8]) and where the non-radio
function is within the scope of one or more of the standards listed in clause 2.1.3 (covering references [9] to [50]).
Requirements applicable to the antenna port specifically related to the efficient use of radio spectrum are not included in
the present document.
NOTE: These requirements are generally found in the applicable product standard(s) for the effective use of the
radio spectrum.
2 References
2.1 Normative references
2.1.1 General
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
In addition, within the present document, some references are non-specific. The applicable version listed in the OJEU
under the Directives 2014/53/EU [i.1] or 2014/30/EU [i.2] may be used.
NOTE 2: Before the date of withdrawal, a preceding version may be used (see clause 2.4 of the Technical Working
Procedures in the ETSI Directives).
2.1.2 Radio EMC standards
[1] ETSI EN 301 489-1: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 1: Common technical requirements; Harmonised Standard for Electromagnetic
Compatibility".
[2] ETSI EN 301 489-3: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies
between 9 kHz and 246 GHz; Harmonised Standard covering the essential requirements of
article 3.1(b) of Directive 2014/53/EU".
[3] ETSI EN 301 489-5: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment
(speech and non-speech) and Terrestrial Trunked Radio (TETRA); Harmonised Standard covering
the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[4] ETSI EN 301 489-6: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 6: Specific conditions for Digital Enhanced Cordless Telecommunications (DECT)
equipment; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive
2014/53/EU".
ETSI
7 ETSI EN 303 446-2 V1.2.1 (2019-10)
[5] ETSI EN 301 489-17: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonised
Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[6] ETSI EN 301 489-19: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating
in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS
band (ROGNSS) providing positioning, navigation, and timing data; Harmonised Standard
covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[7] ETSI EN 301 489-33: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 33: Specific conditions for Ultra-WideBand (UWB) devices; Harmonised Standard
covering the essential requirements of article 3.1(b) of Directive 2014/53/EU".
[8] ETSI EN 301 489-51: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 51: Specific conditions for Automotive, Ground based Vehicles and Surveillance
Radar Devices using 24,05 GHz to 24,25 GHz, 24,05 GHz to 24,5 GHz, 76 GHz to 77 GHz and
77 GHz to 81 GHz; Harmonised Standard covering the essential requirements of article 3.1(b) of
Directive 2014/53/EU".
2.1.3 Non-radio EMC standards
[9] CENELEC EN 50121-3-2: "Railway applications - Electromagnetic compatibility - Part 3-2:
Rolling stock - Apparatus".
[10] CENELEC EN 50121-4: "Railway applications - Electromagnetic compatibility - Part 4: Emission
and immunity of the signalling and telecommunications apparatus".
[11] CENELEC EN 50121-5: "Railway applications - Electromagnetic compatibility - Part 5: Emission
and immunity of fixed power supply installations and apparatus".
[12] CENELEC EN 50270: "Electromagnetic compatibility - Electrical apparatus for the detection and
measurement of combustible gases, toxic gases or oxygen".
[13] CENELEC EN 50293: "Road traffic signal systems - Electromagnetic compatibility".
[14] CENELEC EN 50370-1: "Electromagnetic compatibility (EMC) - Product family standard for
machine tools - Part 1: Emission".
[15] CENELEC EN 50370-2: "Electromagnetic compatibility (EMC) - Product family standard for
machine tools - Part 2: Immunity".
[16] CENELEC EN 50491-5-1: "General requirements for Home and Building Electronic Systems
(HBES) and Building Automation and Control Systems (BACS) - Part 5-1: EMC requirements,
conditions and test set-up".
[17] CENELEC EN 50491-5-3: "General requirements for Home and Building Electronic Systems
(HBES) and Building Automation and Control Systems (BACS) - Part 5-3: EMC requirements for
HBES/BACS used in industry environment".
[18] CENELEC EN 55011: "Industrial, scientific and medical equipment - Radio-frequency
disturbance characteristics - Limits and methods of measurement".
[19] CENELEC EN 55015: "Limits and methods of measurement of radio disturbance characteristics of
electrical lighting and similar equipment".
[20] CENELEC EN 60730-1: "Automatic electrical controls - Part 1: General requirements".
[21] CENELEC EN 60947-1: "Low-voltage switchgear and controlgear - Part 1: General rules".
[22] CENELEC EN 60947-2: "Low-voltage switchgear and controlgear - Part 2: Circuit-breakers".
[23] CENELEC EN 60947-3: "Low-voltage switchgear and controlgear - Part 3: Switches,
disconnectors, switch-disconnectors and fuse-combination units".
ETSI
8 ETSI EN 303 446-2 V1.2.1 (2019-10)
[24] CENELEC EN 60947-4-1: "Low-voltage switchgear and controlgear - Part 4-1: Contactors and
motor-starters - Electromechanical contactors and motor-starters".
[25] CENELEC EN 60947-4-2: "Low-voltage switchgear and controlgear - Part 4-2: Contactors and
motor-starters - AC semiconductor motor controllers and starters".
[26] CENELEC EN 60947-4-3: "Low-voltage switchgear and controlgear - Part 4-3: Contactors and
motor-starters - AC semiconductor controllers and contactors for non-motor loads".
[27] CENELEC EN 60947-5-1: "Low-voltage switchgear and controlgear - Part 5-1: Control circuit
devices and switching elements - Electromechanical control circuit devices".
[28] CENELEC EN 60947-5-2: "Low-voltage switchgear and controlgear - Part 5-2: Control circuit
devices and switching elements - Proximity switches".
[29] CENELEC EN 60947-5-6: "Low-voltage switchgear and controlgear - Part 5-6: Control circuit
devices and switching elements - DC interface for proximity sensors and switching amplifiers
(NAMUR)".
[30] CENELEC EN 60947-5-7: "Low-voltage switchgear and controlgear - Part 5-7: Control circuit
devices and switching elements - Requirements for proximity devices with analogue output".
[31] CENELEC EN 60947-5-9: "Low-voltage switchgear and controlgear - Part 5-9: Control circuit
devices and switching elements - Flow rate switches".
[32] CENELEC EN 60947-6-1: "Low-voltage switchgear and controlgear - Part 6-1: Multiple function
equipment - Transfer switching equipment".
[33] CENELEC EN 60947-6-2: "Low-voltage switchgear and controlgear - Part 6-2: Multiple function
equipment - Control and protective switching devices (or equipment) (CPS)".
[34] CENELEC EN 60947-8: "Low-voltage switchgear and controlgear - Part 8: Control units for
built-in thermal protection (PTC) for rotating electrical machines".
[35] CENELEC EN 60974-10: "Arc welding equipment - Part 10: Electromagnetic compatibility
(EMC) requirements".
[36] CENELEC EN 61000-6-2: "Electromagnetic compatibility (EMC) - Part 6-2: Generic standards -
Immunity standard for industrial environments".
[37] CENELEC EN 61000-6-4: "Electromagnetic compatibility (EMC) - Part 6-4: Generic standards -
Emission standard for industrial environments".
[38] CENELEC EN 61131-2: "Programmable controllers - Part 2: Equipment requirements and tests".
[39] CENELEC EN 61204-3: "Low voltage power supplies, d.c. output - Part 3: Electromagnetic
compatibility (EMC)".
[40] CENELEC EN 61326-1: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 1: General requirements".
[41] CENELEC EN 61326-2-2: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions
and performance criteria for portable test, measuring and monitoring equipment used in low-
voltage distribution systems".
[42] CENELEC EN 61326-2-3: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions
and performance criteria for transducers with integrated or remote signal conditioning".
[43] CENELEC EN 61326-2-4: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions
and performance criteria for insulation monitoring devices according to IEC 61557-8 and for
equipment for insulation fault location according to IEC 61557-9".
ETSI
9 ETSI EN 303 446-2 V1.2.1 (2019-10)
[44] CENELEC EN 61326-2-5: "Electrical equipment for measurement, control and laboratory use -
EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions
and performance criteria for devices with field bus interfaces according to IEC 61784-1".
[45] CENELEC EN 61439-2: "Low-voltage switchgear and controlgear assemblies - Part 2: Power
switchgear and controlgear assemblies".
[46] CENELEC EN 61439-3: "Low-voltage switchg
...