SIST EN 300 019-1-1 V2.2.1:2014
(Main)Environmental Engineering (EE) - Environmental conditions and environmental tests for telecommunications equipment - Part 1-1: Classification of environmental conditions - Storage
General Information
- Abstract
The present document defines classes of environmental conditions and their severities to which telecommunication equipment may be exposed during storage. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %.
NOTE 1: Temporary storage during transport is included in part 1-2: Transportation.
NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.
- Status
- Published
- Public Enquiry End Date
- 28-Feb-2014
- Publication Date
- 15-May-2014
- Technical Committee
- SPN - Services and Protocols for Networks
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 05-May-2014
- Due Date
- 10-Jul-2014
- Completion Date
- 16-May-2014
Buy Documents
ETSI EN 300 019-1-1 V2.1.8 (2013-12) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-1: Classification of environmental conditions; Storage
ETSI EN 300 019-1-1 V2.2.1 (2014-04) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-1: Classification of environmental conditions; Storage
Overview
SIST EN 300 019-1-1 V2.2.1:2014 is a European standard developed by the Slovenian Institute for Standardization (SIST) and ETSI, focusing on environmental engineering for telecommunications equipment. Specifically, it addresses the classification of environmental conditions and their severities to which telecommunications equipment may be exposed during storage. The standard ensures that equipment remains reliable and compliant when stored in a variety of environmental scenarios, minimizing risk due to environmental factors. These environmental conditions and severities have a very low probability of being exceeded, typically less than 1%.
Key Topics
Environmental Classes for Storage:
The standard defines several classes of storage conditions for telecommunications equipment, covering differences in weather protection and temperature/humidity control, with references to widely adopted IEC standards.- Class 1.1: Weatherprotected, partly temperature-controlled storage. Typically inside buildings with some level of environmental control-but without humidity control.
- Class 1.2: Weatherprotected, not temperature-controlled storage. May experience wide fluctuations in temperature and humidity, potentially including condensation and minor ingress of water, sand, or dust.
- Class 1.3 and 1.3E: Non-weatherprotected storage, with extended class for more severe conditions. Equipment could be exposed directly to outdoor climatic extremes, precipitation, and increased biological or mechanical risks.
Climatic, Biological, Chemical, and Mechanical Parameters:
The standard provides detailed guidance for each environmental class covering:- Air temperature and humidity (relative and absolute)
- Solar and heat radiation
- Precipitation and condensation
- Biological threats (mould, rodents)
- Chemically active substances (corrosive gases, salt mists)
- Mechanically active substances (sand, dust)
- Vibration and shock endurance during storage
Packaged Equipment:
Environmental conditions specified in this standard apply to equipment in its packaging, reflecting real-world storage practices.
Applications
SIST EN 300 019-1-1 V2.2.1:2014 is essential for organizations involved in the design, manufacturing, procurement, or storage of telecommunications equipment. Its practical applications include:
- Product Design: Ensures equipment can withstand defined storage environments, helping manufacturers develop robust products.
- Procurement Specifications: Allows buyers to specify equipment that meets particular storage conditions for safe keeping in varying environments.
- Logistics and Warehousing: Guides organizations on appropriate storage methods and locations for equipment, considering risk factors like temperature variation, moisture, or dust.
- Risk Mitigation: Reduces the chance of equipment failure or degradation due to improper storage, safeguarding investments and service reliability.
- Regulatory Compliance: Helps organizations comply with European and international standards, increasing global market access and standardization.
Related Standards
The following standards are referenced or related to SIST EN 300 019-1-1 V2.2.1:2014:
- EN 300 019 Series: Covers classifications and test specifications for environmental conditions relating to storage, transportation, stationary use, vehicle installations, and more.
- IEC 60721-3-1: Classification of environmental conditions-storage.
- IEC 60068-2-27: Environmental testing-shock.
- IEC 60721-2-4: Environmental conditions-solar radiation and temperature.
- Other Parts of EN 300 019: Address transport (Part 1-2), stationary and mobile operational environments, and testing methods.
Applying SIST EN 300 019-1-1 V2.2.1:2014 ensures telecommunications equipment is stored under conditions that protect its integrity, longevity, and readiness for deployment, providing a foundation for effective environmental risk management in the telecom sector.
Buy Documents
ETSI EN 300 019-1-1 V2.1.8 (2013-12) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-1: Classification of environmental conditions; Storage
ETSI EN 300 019-1-1 V2.2.1 (2014-04) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-1: Classification of environmental conditions; Storage
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.
IMP NDT d.o.o.
Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.
Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 300 019-1-1 V2.2.1:2014 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Environmental Engineering (EE) - Environmental conditions and environmental tests for telecommunications equipment - Part 1-1: Classification of environmental conditions - Storage". This standard covers: The present document defines classes of environmental conditions and their severities to which telecommunication equipment may be exposed during storage. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. NOTE 1: Temporary storage during transport is included in part 1-2: Transportation. NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.
The present document defines classes of environmental conditions and their severities to which telecommunication equipment may be exposed during storage. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. NOTE 1: Temporary storage during transport is included in part 1-2: Transportation. NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.
SIST EN 300 019-1-1 V2.2.1:2014 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 019-1-1 V2.2.1:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Draft ETSI EN 300 019-1-1 V2.1.8 (2013-12)
European Standard
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1-1: Classification of environmental conditions;
Storage
2 Draft ETSI EN 300 019-1-1 V2.1.8 (2013-12)
Reference
REN/EE-0154
Keywords
environment, equipment practice, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2013.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM TM
3GPP and LTE are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
3 Draft ETSI EN 300 019-1-1 V2.1.8 (2013-12)
Contents
Intellectual Property Rights . 4
Foreword . 4
1 Scope . 5
2 References . 5
2.1 Normative references . 5
2.2 Informative references . 5
3 Definitions . 5
4 Environmental classes . 6
4.1 Class 1.1: Weatherprotected, partly temperature-controlled storage locations . 6
4.2 Class 1.2: Weatherprotected, not temperature-controlled storage locations . 7
4.3 Class 1.3: Non-weatherprotected storage locations; class 1.3E: non-weatherprotected storage locations-
extended . 8
5 Environmental conditions. 10
5.1 Climatic conditions. 10
5.2 Biological conditions . 10
5.3 Chemically active substances . 11
5.4 Mechanically active substances . 11
5.5 Mechanical conditions . 12
Annex A (informative): Bibliography . 13
History . 14
ETSI
4 Draft ETSI EN 300 019-1-1 V2.1.8 (2013-12)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://ipr.etsi.org).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE),
and is now submitted for the combined Public Enquiry and Vote phase of the ETSI standards EN Approval Procedure.
The present document is part 1, sub-part 1 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions": (see note 1)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests" (see note 2).
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use. Sub-part 1-0 forms a general overview of part 1.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa
ETSI
5 Draft ETSI EN 300 019-1-1 V2.1.8 (2013-12)
1 Scope
The present document defines classes of environmental conditions and their severities to which telecommunication
equipment may be exposed during storage. The severities specified are those which will have a low probability of being
exceeded; generally less than 1 %.
NOTE 1: Temporary storage during transport is included in part 1-2: Transportation.
NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
Not applicable.
2.2 Informative references
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] Void.
[i.2] IEC 60721-3-1:1997: "Classification of environmental conditions - Part 3: Classification of groups
of environmental parameters and their severities - Section 1: Storage".
[i.3] IEC 60068-2-27:2005: "Environmental testing. Part 2: Tests. Test Ea and guidance: Shock".
[i.4] IEC 60721-2-4:2002: "Classification of environmental conditions. Part 2: Environmental
conditions appearing in nature: Solar radiation and temperature".
3 Definitions
For the purposes of the present document, the following terms and definitions apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
storage: certain site where the equipment is placed for long periods but is not intended for use during these periods
ETSI
6 Draft ETSI EN 300 019-1-1 V2.1.8 (2013-12)
weatherprotected location: location at which the equipment is protected from weather influences
NOTE 1: Totally weatherprotected location: Direct weather influences are totally excluded.
NOTE 2: Partly weatherprotected location: Direct weather influences are not completely excluded.
4 Environmental classes
The classes shown in parentheses, e.g. (1C1), may be selected for special applications.
4.1 Class 1.1: Weatherprotected, partly temperature-controlled
storage locations
This class is a combination of classes 1K3/1Z2/1B1/1C2(1C1)/1S2/1M2 in IEC 60721-3-1 [i.2].
This class shall apply to weatherprotected partly temperature controlled storage. Humidity is usually not controlled. The
climatogram is shown in figure 1.
Heating may be used to raise low temperatures especially where there is a significant difference between the conditions
of this class and the open-air climate. Bu
...
European Standard
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1-1: Classification of environmental conditions;
Storage
2 ETSI EN 300 019-1-1 V2.2.1 (2014-04)
Reference
REN/EE-0154
Keywords
environment, equipment practice, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
The present document can be downloaded from:
http://www.etsi.org
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2014.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
3 ETSI EN 300 019-1-1 V2.2.1 (2014-04)
Contents
Intellectual Property Rights . 4
Foreword . 4
1 Scope . 5
2 References . 5
2.1 Normative references . 5
2.2 Informative references . 5
3 Definitions . 5
4 Environmental classes . 6
4.1 Class 1.1: Weatherprotected, partly temperature-controlled storage locations . 6
4.2 Class 1.2: Weatherprotected, not temperature-controlled storage locations . 7
4.3 Class 1.3: Non-weatherprotected storage locations; class 1.3E: non-weatherprotected storage locations-
extended . 8
5 Environmental conditions. 10
5.1 Climatic conditions. 10
5.2 Biological conditions . 10
5.3 Chemically active substances . 11
5.4 Mechanically active substances . 11
5.5 Mechanical conditions . 12
Annex A (informative): Bibliography . 13
History . 14
ETSI
4 ETSI EN 300 019-1-1 V2.2.1 (2014-04)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://ipr.etsi.org).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE).
The present document is part 1, sub-part 1 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions": (see note 1)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests" (see note 2).
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use. Sub-part 1-0 forms a general overview of part 1.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
National transposition dates
Date of adoption of this EN: 21 April 2014
Date of latest announcement of this EN (doa): 31 July 2014
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 January 2015
Date of withdrawal of any conflicting National Standard (dow): 31 January 2015
ETSI
5 ETSI EN 300 019-1-1 V2.2.1 (2014-04)
1 Scope
The present document defines classes of environmental conditions and their severities to which telecommunication
equipment may be exposed during storage. The severities specified are those which will have a low probability of being
exceeded; generally less than 1 %.
NOTE 1: Temporary storage during transport is included in part 1-2: Transportation.
NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
Not applicable.
2.2 Informative references
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] Void.
[i.2] IEC 60721-3-1:1997: "Classification of environmental conditions - Part 3: Classification of groups
of environmental parameters and their severities - Section 1: Storage".
[i.3] IEC 60068-2-27:2005: "Environmental testing. Part 2: Tests. Test Ea and guidance: Shock".
[i.4] IEC 60721-2-4:2002: "Classification of environmental conditions. Part 2: Environmental
conditions appearing in nature: Solar radiation and temperature".
3 Definitions
For the purposes of the present document, the following terms and definitions apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
storage: certain site where the equipment is placed for long periods but is not intended for use during these periods
ETSI
6 ETSI EN 300 019-1-1 V2.2.1 (2014-04)
weatherprotected location: location at which the equipment is protected from weather influences
NOTE 1: Totally weatherprotected location: Direct weather influences are totally excluded.
NOTE 2: Partly weatherprotected location: Direct weather influences are not completely excluded.
4 Environmental classes
The classes shown in parentheses, e.g. (1C1), may be selected for special applications.
4.1 Class 1.1: Weatherprotected, partly temperature-controlled
storage locations
This class is a combination of classes 1K3/1Z2/1B1/1C2(1C1)/1S2/1M2 in IEC 60721-3-1 [i.2].
This class shall apply to weatherprotected partly temperature controlled storage. Humidity is usually not controlled. The
climatogram is shown in figure 1.
Heating may be used to raise low temperatures especially where there is a significant di
...
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.6NODGLãþHQMHEnvironmental Engineering (EE) - Environmental conditions and environmental tests for telecommunications equipment - Part 1-1: Classification of environmental conditions - Storage33.050.01Telekomunikacijska terminalska oprema na splošnoTelecommunication terminal equipment in general19.040Preskušanje v zvezi z okoljemEnvironmental testingICS:Ta slovenski standard je istoveten z:EN 300 019-1-1 Version 2.2.1SIST EN 300 019-1-1 V2.2.1:2014en01-junij-2014SIST EN 300 019-1-1 V2.2.1:2014SLOVENSKI
STANDARD
European Standard SIST EN 300 019-1-1 V2.2.1:2014
ETSI ETSI EN 300 019-1-1 V2.2.1 (2014-04)2
Reference REN/EE-0154 Keywords environment, equipment practice, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88
Important notice The present document can be downloaded from: http://www.etsi.org The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http://portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2014. All rights reserved.
DECTTM, PLUGTESTSTM, UMTSTM and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association. SIST EN 300 019-1-1 V2.2.1:2014
ETSI ETSI EN 300 019-1-1 V2.2.1 (2014-04)3 Contents Intellectual Property Rights . 4 Foreword . 4 1 Scope . 5 2 References . 5 2.1 Normative references . 5 2.2 Informative references . 5 3 Definitions . 5 4 Environmental classes . 6 4.1 Class 1.1: Weatherprotected, partly temperature-controlled storage locations . 6 4.2 Class 1.2: Weatherprotected, not temperature-controlled storage locations . 7 4.3 Class 1.3: Non-weatherprotected storage locations; class 1.3E: non-weatherprotected storage locations-extended . 8 5 Environmental conditions. 10 5.1 Climatic conditions. 10 5.2 Biological conditions . 10 5.3 Chemically active substances . 11 5.4 Mechanically active substances . 11 5.5 Mechanical conditions . 12 Annex A (informative): Bibliography . 13 History . 14
ETSI ETSI EN 300 019-1-1 V2.2.1 (2014-04)4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http://ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 1, sub-part 1 of a multi-part deliverable covering the classification of environmental conditions and environmental tests for telecommunications equipment, as identified below: Part 1: "Classification of environmental conditions": (see note 1) Sub-part 0:
"Introduction"; Sub-part 1: "Storage"; Sub-part 2:
"Transportation"; Sub-part 3:
"Stationary use at weatherprotected locations"; Sub-part 4:
"Stationary use at non-weatherprotected locations"; Sub-part 5:
"Ground vehicle installations"; Sub-part 6:
"Ship environments"; Sub-part 7:
"Portable and non-stationary use"; Sub-part 8:
"Stationary use at underground locations"; Part 2: "Specification of environmental tests" (see note 2). NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions, chemically and mechanically active substances and mechanical conditions during storage, transportation and in use. Sub-part 1-0 forms a general overview of part 1. NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
National transposition dates Date of adoption of this EN: 21 April 2014 Date of latest announcement of this EN (doa): 31 July 2014 Date of latest publication of new National Standard or endorsement of this EN (dop/e):
31 January 2015 Date of withdrawal of any conflicting National Standard (dow): 31 January 2015
ETSI ETSI EN 300 019-1-1 V2.2.1 (2014-04)5 1 Scope The present document defines classes of environmental conditions and their severities to which telecommunication equipment may be exposed during storage. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. NOTE 1: Temporary storage during transport is included in part 1-2: Transportation. NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the reference document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present document. Not applicable. 2.2 Informative references The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. [i.1] Void. [i.2] IEC 60721-3-1:1997: "Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 1: Storage". [i.3] IEC 60068-2-27:2005: "Environmental testing. Part 2: Tests. Test Ea and guidance: Shock". [i.4] IEC 60721-2-4:2002: "Classification of environmental conditions. Part 2: Environmental conditions appearing in nature: Solar radiation and temperature". 3 Definitions For the purposes of the present document, the following terms and definitions apply: absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an air/water vapour mixture non-weatherprotected location: location at which equipment is not protected from direct weather influences relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial pressure of the water vapour in saturated air at the same temperature storage: certain site where the equipment is placed for long periods but is not intended for use during these periods SIST EN 300 019-1-1 V2.2.1:2014
ETSI ETSI EN 300 019-1-1 V2.2.1 (2014-04)6 weatherprotected location: location at which the equipment is protected from weather influences NOTE 1: Totally weatherprotected location: Direct weather influences are totally excluded. NOTE 2: Partly weatherprotected location: Direct weather influences are not complete
...