ISO 6475:1989
(Main)Implants for surgery — Metal bone screws with asymmetrical thread and spherical under-surface — Mechanical requirements and test methods
Implants for surgery — Metal bone screws with asymmetrical thread and spherical under-surface — Mechanical requirements and test methods
This standard does not relate to all safety problems concerned with application. It bases on the dimensions of bone screws given in ISO 5835 and ISO 5832-1. The results obtained does not have a direct correlation to the application of screws. Annex A is normative and contains mechanical requirements to bone screws made from stainless steel. The informative Annexes B and C show the intercorrelations of international standards for bone screws, plates and the corresponding tools and a bibliography.
Implants chirurgicaux — Vis métalliques à filetage asymétrique et à embase sphérique pour os — Caractéristiques mécaniques et méthodes d'essai
General Information
- Status
- Published
- Publication Date
- 18-Oct-1989
- Technical Committee
- ISO/TC 150/SC 5 - Osteosynthesis and spinal devices
- Drafting Committee
- ISO/TC 150/SC 5 - Osteosynthesis and spinal devices
- Current Stage
- 9020 - International Standard under periodical review
- Start Date
- 15-Apr-2026
- Completion Date
- 15-Apr-2026
Relations
- Effective Date
- 15-Apr-2008
- Effective Date
- 15-Apr-2008
Overview
ISO 6475:1989 specifies the mechanical requirements and test methods for metal bone screws with asymmetrical threads and spherical under-surfaces, intended for surgical implants. Developed by the International Organization for Standardization (ISO), this standard ensures uniformity and quality for bone screws used in medical device manufacturing and orthopaedic surgery. While the test results do not directly reflect clinical performance, they provide a reliable basis for product consistency and regulatory compliance. The requirements primarily apply to screws made of stainless steel, referencing ISO 5835 for dimensional compatibility and ISO 5832-1 for material properties.
Key Topics
- Mechanical Testing: ISO 6475 defines procedures for determining breaking torque and angle of rotation at failure, essential attributes ensuring that bone screws can withstand surgical stresses.
- Test Conditions: The standard outlines apparatus requirements, such as machine sensitivity, measuring range, and the method for applying torque during testing.
- Sample Selection: Only screws meeting specified dimensional standards are used for testing. Non-compliance triggers more extensive sampling and retesting procedures.
- Surface Quality: Screws must be free of defects or surface imperfections that could compromise performance or patient safety.
- Material Reference: The standard currently covers screws made of stainless steel per ISO 5832-1, and other materials may be included in future updates.
- Safety Considerations: Users are responsible for observing appropriate safety and regulatory practices, as ISO 6475 does not address all application risks.
Applications
ISO 6475 is widely used in the following areas:
- Orthopaedic Implant Manufacturing: Ensures bone screw products meet internationally recognized mechanical requirements, supporting product reliability and market acceptance.
- Quality Assurance: Provides standardized test methods for verifying the mechanical strength of surgical screws during production and quality control.
- Regulatory Compliance: Assists manufacturers in meeting medical device regulatory requirements by aligning product testing with global standards.
- Research & Development: Supports R&D teams in benchmarking new bone screw designs against standardized mechanical criteria.
- Industry Standardization: Facilitates compatibility and interoperability with related implants, instruments, and surgical tools defined in referenced ISO standards.
Manufacturers, testing laboratories, and regulatory bodies rely on ISO 6475 to confirm that bone screws deliver consistent performance under defined test conditions, thus reducing variability and potential device failure in surgical applications.
Related Standards
To ensure complete conformity and integration with surgical systems, ISO 6475:1989 should be used in conjunction with:
- ISO 5835: Specifies dimensions for metal bone screws with hexagonal drives and spherical under-surfaces, ensuring compatibility with surgical instruments.
- ISO 5832-1: Covers the properties of wrought stainless steel for implant use, establishing material requirements and traceability.
- ISO 8319-1 & ISO 8319-2: Define connection interfaces for orthopaedic instruments, covering keys and screwdrivers for various screw head designs.
- ISO 5836: Details requirements for metal bone plates with holes for compatible screws.
- ISO 9268 & ISO 9269: Address design and mechanical tests for bone plates and matching screw holes.
- ISO 9714-1: Provides specifications for drilling and tapping tools used with bone screws.
By adhering to ISO 6475 and its related standards, the medical device industry promotes safer, more effective, and globally accepted surgical implants and instruments.
Keywords: ISO 6475, surgical implants, bone screws, mechanical requirements, test methods, orthopaedic surgery, stainless steel implants, international standards, medical device testing, quality assurance, regulatory compliance.
Buy Documents
ISO 6475:1989 - Implants for surgery — Metal bone screws with asymmetrical thread and spherical under-surface — Mechanical requirements and test methods Released:10/19/1989
ISO 6475:1989 - Implants chirurgicaux — Vis métalliques a filetage asymétrique et a embase sphérique pour os — Caractéristiques mécaniques et méthodes d'essai Released:10/19/1989
ISO 6475:1989 - Implants chirurgicaux — Vis métalliques a filetage asymétrique et a embase sphérique pour os — Caractéristiques mécaniques et méthodes d'essai Released:10/19/1989
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.
Sponsored listings
Frequently Asked Questions
ISO 6475:1989 is a standard published by the International Organization for Standardization (ISO). Its full title is "Implants for surgery — Metal bone screws with asymmetrical thread and spherical under-surface — Mechanical requirements and test methods". This standard covers: This standard does not relate to all safety problems concerned with application. It bases on the dimensions of bone screws given in ISO 5835 and ISO 5832-1. The results obtained does not have a direct correlation to the application of screws. Annex A is normative and contains mechanical requirements to bone screws made from stainless steel. The informative Annexes B and C show the intercorrelations of international standards for bone screws, plates and the corresponding tools and a bibliography.
This standard does not relate to all safety problems concerned with application. It bases on the dimensions of bone screws given in ISO 5835 and ISO 5832-1. The results obtained does not have a direct correlation to the application of screws. Annex A is normative and contains mechanical requirements to bone screws made from stainless steel. The informative Annexes B and C show the intercorrelations of international standards for bone screws, plates and the corresponding tools and a bibliography.
ISO 6475:1989 is classified under the following ICS (International Classification for Standards) categories: 11.040.40 - Implants for surgery, prosthetics and orthotics. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 6475:1989 has the following relationships with other standards: It is inter standard links to ISO 6475-1:1980, ISO 6475-2:1980. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 6475:1989 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 6475
First edition
1989-11-01
Implants for surgery - Metal bone screws with
asymmetrical thread and spherical under-surface
- Mechanical requirements and test methods
- Vis m6taliiques 2 filetage
lmplan ts chirurgicaux asymktrique et A embase
spherique pour OS - Carac t&is tiques mkaniques et methodes d’essai
Reference number
ISO 6475 : 1989 (El
ISO 6475 : 1989 (El
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of
national Standards bodies (ISO member bedies). The work of preparing International
Standards is normally carried out through ISO technical committees. Esch member
body interested in a subject for which a technical committee has been established has
International organizations, govern-
the right to be represented on that committee.
mental and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission (IEC) on all
matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the ISO Council. They are approved in accordance with ISO procedures requiring at
least 75 % approval by the member bodies voting.
International Standard ISO 6475 was prepared by Technical Committee ISO/TC 150,
lmplan ts for surgery.
This first edition of ISO 6475 cancels and replaces the first editions of ISO 6475-1 :
1980 and ISO 6475-2 : 1980, of which it constitutes a revision and amalgamation.
Annex A forms an integral part of this International Standard. A .nnexes B and C are for
information only.
63 ISO 1989
All rights reserved. No part of this publication may be reproduced or utilized in any form or by any
means, electronie or mechanical, including photocopying and microfilm, without permission in
writing from the publisher.
International Organization for Standardization
Case postale 56 l CH-121 1 Geneve 20 l Switzerland
Printed in Switzerland
ii
ISO 6475 : 1989 (El
Introduction
This International Standard does not purport to address all of the safety Problems
associated with its use. lt is the responsibility of whoever uses it to consult and
establish appropriate safety and health practices and determine the applicability of
regulatory limitations Prior to use.
The results obtained in this method bear no direct correlation to the use of the subject
bone screw. This test method is used only for purposes of maintaining the uniformity
of the product tested.
This page intentionally Mt blank
ISO 6475 : 1989 (E)
INTERNATIONAL STANDARD
Metal bone screws with
Implants for surgery -
asymmetrical thread and spherical under-surface -
Mechanical requirements and test methods
1 Scope 3 Test method
This International Standard specifies the test methods for
3.1 Apparatus
determining breaking torque and angle of rotation at failure for
metal bone screws for surgery. Mechanical requirements for
A test machine having the following characteristics shall be
bone screws are specified in annex A.
used :
NOTES
a) a maximum sensitivity on the lowest measuring range
1 At present data are only available for bone screws with dimensions
of not less than 0,Ol Nm or equivalent, and on other scales
according to ISO 5835 and made from stainless steel according to
of not less than 1 % of full scale reading;
ISO 5832-1. If data become available for bone screws made from other
materials and/or with other standardized dimensions, they will be
b) a selection of measuring ranges (sec 3.2.4);
added in further annexes.
2 The interrelationship of International Standards dealing with bone
c) the capability of recording the maximum torque at-
plates, bone screws and relevant tools is shown for information in
tained during the test;
annex B.
d) a device to prevent the screw becoming disengaged
from the component by means of which the torque is ap-
plied.
2 Normative references
NOTE - In some countries the test machine must comply with the re-
The following Standards contain provisions which, through
quirements laid down by the national test or verification authority.
reference in this text, constitute provisions of this International
Standard. At the time of publication, the editions indicated
were valid. All Standards are subject to revision, and Parties to
3.2 Brocedure
agreements based on this International Standard are encouraged
to investigate the possibility of applying the most recent
3.2.1 Insert the screw under test into the test block and clamp
editions of the Standards indicated below. Members sf IEC and
ISO maintain registers of currently valid International Stan- it so that the following conditions are met:
dards.
a) if possible, five full threads from the thread run-out shall
be exposed;
ISO !3832- 1 : 1987, lmplan ts for surgery - Metallic materials -
Part 7 : Wrough t stainless steel.
b) movement of the clamped Portion shall be prevented;
ISO5835: - 11, lmplants for surgery - Metal bone screws
c) the axes of the screw and the component by means of
with hexagonal drive connection - Spherical under-surface of
head, as ymme trical thread - Dimensions. which the torque is applied shall be coincident.
1) Will cancel and replace ISO 5835-1 at next revision Stage. (ISO 5835-1 cancelled and replaced ISO 5835-1 : 1978 and ISO 5835-2 : 1978.)
Is06475:1989 (EI
b) the maximum breaking torque, expressed to the nearest
3.2.2 Apply torque so that the screw head rotates at a
0,l Nmm;
uniform angular veloci
...
NORME ISO
INTERNATIONALE
Première édition
1989-l l-01
Implants chirurgicaux - Vis métalliques
à filetage asymétrique et à embase sphérique
- Caractéristiques mécaniques
pour os
et méthodes d’essai
lmplants for surgery - Metal bone screws with asymmetrical thread and spherical
under-surface - Mechanical requirements and test methods
Numéro de référence
ISO 6475 : 1989 (FI
ISO 6475 : 1989 (FI
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (comités membres de I’ISO). L’élaboration
des Normes internationales est en général confiée aux comités techniques de I’ISO.
Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO participent également aux travaux. L’ISO col-
labore étroitement avec la Commission électrotechnique internationale (CEI) en ce qui
concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques sont soumis
aux comités membres pour approbation, avant leur acceptation comme Normes inter-
nationales par le Conseil de I’ISO. Les Normes internationales sont approuvées confor-
mément aux procédures de I’ISO qui requièrent l’approbation de 75 % au moins des
comités membres votants.
La Norme internationale ISO 6475 a été élaborée par le comité technique ISO/TC 150,
lmplants chirurgicaux.
Cette première édition de I’ISO 6475 annule et remplace les premières éditions de
I’ISO 6475-l : 1980 et de I’ISO 6472-2 : 1980, dont elle constitue une révision et une
combinaison.
L’annexe A fait partie intégrante de la présente Norme internationale. Les annexes B et
C sont données uniquement à titre d’information.
0 ISO 1989
Droits de reproduction réservés. Aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie et les microfilms, sans l’accord écrit de l’éditeur.
Organisation internationale de normalisation
Case postale 56 l CH-121 1 Genève 20 l Suisse
Imprimé en Suisse
ii
ISO 6475 : 1989 (F)
Introduction
La présente Norme internationale n’a pas pour but de traiter de tous les problémes de
securité liés à l’utilisation. II est de la responsabilité de tout utilisateur de la présente
Norme internationale de consulter et d’établir les pratiques de santé et de sécurité
appropriées et de déterminer I’applicabilité des prescriptions réglementaires avant
Les résultats obtenus par cette méthode ne sont pas en corrélation directe avec l’utili-
sation des vis pour os. La présente méthode d’essai est spécifiée uniquement dans le
but de maintenir l’uniformité du produit testé.
Page blanche
ISO 6475: 1989 (F)
NORME INTERNATIONALE
lmplants chirurgicaux - Vis métalliques à filetage
asymétrique et à embase sphérique pour os -
Caractéristiques mécaniques et méthodes d’essai
3 Méthode d’essai
1 Objet et domaine d’application
La présente Norme internationale précise les méthodes d’essai
3.1 Appareillage
de détermination du couple de torsion et de l’angle de rotation
à la rupture des vis métalliques pour os utilisées en chirurgie.
Une machine d’essai ayant les caractéristiques suivantes doit
Les caractéristiques mécaniques des vis pour os sont spécifiées être utilisée :
à l’annexe A.
a) la sensibilité maximale, sur l’échelle de mesure la plus
faible, ne doit pas être inférieure à 0,Ol Nmrn ou unité équi-
NOTES
valente et, sur les autres échelles, pas inférieure à 1 % de la
1 Actuellement des données sont disponibles seulement pour les vis
déformation à pleine charge;
pour os fabriquées en acier inoxydable conforme à I’ISO 5832-1, dont
les dimensions sont conformes à I’ISO 5835. Lorsque des données
b) le choix de la gamme de mesurage (voir 3.2.4);
seront disponibles pour des vis pour os ayant d’autres dimensions nor-
malisées et/ou fabriquées à partir d’autres matériaux, elles seront intro-
c) la possibilité d’enregistrer la valeur maximale du couple
duites dans de nouvelles annexes.
de torsion obtenue au cours de l’essai;
2 Les corrélations entre les Normes internationales relatives aux vis
pour os, aux plaques pour os et aux instruments correspondants sont d) un dispositif empêchant un désengagement de la vis de
indiquées pour information en annexe B.
l’élément sur lequel le couple de torsion est appliqué.
NOTE - Dans certains pays, il est demandé que la machine d’essai
réponde aux spécifications nationales d’essais ou aux spécifications de
2 Références normatives
l’organisme de vérification.
Les normes suivantes contiennent des dispositions qui, par
3.2 Mode opératoire
suite de la référence qui en est faite, constituent des disposi-
tions valables pour la présente Norme internationale. Au
3.2.1 Insérer la vis soumise à l’essai dans le bloc et la mainte-
moment de la publication, les éditions indiquées étaient en
nir de facon à ce que:
vigueur. Toute norme est sujette à révision et les parties pre-
nantes des accords fondés sur la présente Norme internationale
a) cinq filets, si possible, soient laissés libres;
sont invitées à rechercher la possibilité d’appliquer les éditions
les plus récentes des normes indiquées ci-après. Les membres
b) le mouvement de la partie maintenue soit impossible;
de la CEI et de I’ISO possèdent le registre des Normes interna-
tionales en vigueur à un moment donné.
c) les axes de la vis et de l’élément qui applique le couple
de torsion coïncide.
ISO 5832-l : 1987, lmplants chirurgicaux - Produits à base de
métaux - Partie 7: Acier à forger inoxydable.
3.2.2 Appliquer le couple de torsion de sorte que la tête de vis
ISO5835: - 11, lmplan ts chirurgicaux - Vis métalliques pour tourne à une fréquence de rotation constante dans la gamme
de 1 tr/min à 5 tr/min*) avec une augmentation constante
os à raccord d’entraînement hexagonal - Embase sphérique et
file tage asymétrique - Dimensions. jusqu’à cassure de la vis.
1) Annulera et remplacera I’ISO 5835-l lors de la prochaine révision. (L’ISO 5835-l a
...
NORME ISO
INTERNATIONALE
Première édition
1989-l l-01
Implants chirurgicaux - Vis métalliques
à filetage asymétrique et à embase sphérique
- Caractéristiques mécaniques
pour os
et méthodes d’essai
lmplants for surgery - Metal bone screws with asymmetrical thread and spherical
under-surface - Mechanical requirements and test methods
Numéro de référence
ISO 6475 : 1989 (FI
ISO 6475 : 1989 (FI
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (comités membres de I’ISO). L’élaboration
des Normes internationales est en général confiée aux comités techniques de I’ISO.
Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO participent également aux travaux. L’ISO col-
labore étroitement avec la Commission électrotechnique internationale (CEI) en ce qui
concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques sont soumis
aux comités membres pour approbation, avant leur acceptation comme Normes inter-
nationales par le Conseil de I’ISO. Les Normes internationales sont approuvées confor-
mément aux procédures de I’ISO qui requièrent l’approbation de 75 % au moins des
comités membres votants.
La Norme internationale ISO 6475 a été élaborée par le comité technique ISO/TC 150,
lmplants chirurgicaux.
Cette première édition de I’ISO 6475 annule et remplace les premières éditions de
I’ISO 6475-l : 1980 et de I’ISO 6472-2 : 1980, dont elle constitue une révision et une
combinaison.
L’annexe A fait partie intégrante de la présente Norme internationale. Les annexes B et
C sont données uniquement à titre d’information.
0 ISO 1989
Droits de reproduction réservés. Aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie et les microfilms, sans l’accord écrit de l’éditeur.
Organisation internationale de normalisation
Case postale 56 l CH-121 1 Genève 20 l Suisse
Imprimé en Suisse
ii
ISO 6475 : 1989 (F)
Introduction
La présente Norme internationale n’a pas pour but de traiter de tous les problémes de
securité liés à l’utilisation. II est de la responsabilité de tout utilisateur de la présente
Norme internationale de consulter et d’établir les pratiques de santé et de sécurité
appropriées et de déterminer I’applicabilité des prescriptions réglementaires avant
Les résultats obtenus par cette méthode ne sont pas en corrélation directe avec l’utili-
sation des vis pour os. La présente méthode d’essai est spécifiée uniquement dans le
but de maintenir l’uniformité du produit testé.
Page blanche
ISO 6475: 1989 (F)
NORME INTERNATIONALE
lmplants chirurgicaux - Vis métalliques à filetage
asymétrique et à embase sphérique pour os -
Caractéristiques mécaniques et méthodes d’essai
3 Méthode d’essai
1 Objet et domaine d’application
La présente Norme internationale précise les méthodes d’essai
3.1 Appareillage
de détermination du couple de torsion et de l’angle de rotation
à la rupture des vis métalliques pour os utilisées en chirurgie.
Une machine d’essai ayant les caractéristiques suivantes doit
Les caractéristiques mécaniques des vis pour os sont spécifiées être utilisée :
à l’annexe A.
a) la sensibilité maximale, sur l’échelle de mesure la plus
faible, ne doit pas être inférieure à 0,Ol Nmrn ou unité équi-
NOTES
valente et, sur les autres échelles, pas inférieure à 1 % de la
1 Actuellement des données sont disponibles seulement pour les vis
déformation à pleine charge;
pour os fabriquées en acier inoxydable conforme à I’ISO 5832-1, dont
les dimensions sont conformes à I’ISO 5835. Lorsque des données
b) le choix de la gamme de mesurage (voir 3.2.4);
seront disponibles pour des vis pour os ayant d’autres dimensions nor-
malisées et/ou fabriquées à partir d’autres matériaux, elles seront intro-
c) la possibilité d’enregistrer la valeur maximale du couple
duites dans de nouvelles annexes.
de torsion obtenue au cours de l’essai;
2 Les corrélations entre les Normes internationales relatives aux vis
pour os, aux plaques pour os et aux instruments correspondants sont d) un dispositif empêchant un désengagement de la vis de
indiquées pour information en annexe B.
l’élément sur lequel le couple de torsion est appliqué.
NOTE - Dans certains pays, il est demandé que la machine d’essai
réponde aux spécifications nationales d’essais ou aux spécifications de
2 Références normatives
l’organisme de vérification.
Les normes suivantes contiennent des dispositions qui, par
3.2 Mode opératoire
suite de la référence qui en est faite, constituent des disposi-
tions valables pour la présente Norme internationale. Au
3.2.1 Insérer la vis soumise à l’essai dans le bloc et la mainte-
moment de la publication, les éditions indiquées étaient en
nir de facon à ce que:
vigueur. Toute norme est sujette à révision et les parties pre-
nantes des accords fondés sur la présente Norme internationale
a) cinq filets, si possible, soient laissés libres;
sont invitées à rechercher la possibilité d’appliquer les éditions
les plus récentes des normes indiquées ci-après. Les membres
b) le mouvement de la partie maintenue soit impossible;
de la CEI et de I’ISO possèdent le registre des Normes interna-
tionales en vigueur à un moment donné.
c) les axes de la vis et de l’élément qui applique le couple
de torsion coïncide.
ISO 5832-l : 1987, lmplants chirurgicaux - Produits à base de
métaux - Partie 7: Acier à forger inoxydable.
3.2.2 Appliquer le couple de torsion de sorte que la tête de vis
ISO5835: - 11, lmplan ts chirurgicaux - Vis métalliques pour tourne à une fréquence de rotation constante dans la gamme
de 1 tr/min à 5 tr/min*) avec une augmentation constante
os à raccord d’entraînement hexagonal - Embase sphérique et
file tage asymétrique - Dimensions. jusqu’à cassure de la vis.
1) Annulera et remplacera I’ISO 5835-l lors de la prochaine révision. (L’ISO 5835-l a
...












Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...