Road vehicles — Electrical disturbances from conduction and coupling — Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines

ISO 7637-3:2016 defines bench test methods to evaluate the immunity of devices under test (DUTs) to transient pulses coupled to lines other than supply lines. The test pulses simulate both fast and slow transient disturbances caused by the switching of inductive loads and relay contact bounce. The following three test methods are described in ISO 7637-3:2016: - capacitive coupling clamp (CCC) method; - direct capacitive coupling (DCC) method; - inductive coupling clamp (ICC) method. ISO 7637-3:2016 applies to road vehicles fitted with nominal 12 V or 24 V electrical systems. For transient pulses immunity, Annex B provides recommended test severity levels in line with the functional performance status classification (FPSC) principle described in ISO 7637‑1.

Véhicules routiers — Perturbations électriques par conduction et par couplage — Partie 3: Transmission des perturbations électriques par couplage capacitif ou inductif le long des lignes autres que les lignes d'alimentation

General Information

Status
Published
Publication Date
30-Jun-2016
Current Stage
9093 - International Standard confirmed
Start Date
30-Jun-2022
Completion Date
19-Apr-2025
Ref Project

Relations

Standard
ISO 7637-3:2016 - Road vehicles -- Electrical disturbances from conduction and coupling
English language
25 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 7637-3:2016 - Road vehicles -- Electrical disturbances from conduction and coupling
English language
25 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


DRAFT INTERNATIONAL STANDARD
ISO/DIS 7637-3
ISO/TC 22/SC 3 Secretariat: DIN
Voting begins on: Voting terminates on:
2014-07-28 2014-10-28
Road vehicles — Electrical disturbances from conduction
and coupling —
Part 3:
Electrical transient transmission by capacitive and
inductive coupling via lines other than supply lines
Véhicules routiers — Perturbations électriques par conduction et par couplage —
Partie 3: Transmission des perturbations électriques par couplage capacitif ou inductif le long des lignes
autres que les lignes d’alimentation
ICS: 43.040.10
THIS DOCUMENT IS A DRAFT CIRCULATED
FOR COMMENT AND APPROVAL. IT IS
THEREFORE SUBJECT TO CHANGE AND MAY
NOT BE REFERRED TO AS AN INTERNATIONAL
STANDARD UNTIL PUBLISHED AS SUCH.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
STANDARDS MAY ON OCCASION HAVE TO
BE CONSIDERED IN THE LIGHT OF THEIR
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
Reference number
NATIONAL REGULATIONS.
ISO/DIS 7637-3:2014(E)
RECIPIENTS OF THIS DRAFT ARE INVITED
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
©
PROVIDE SUPPORTING DOCUMENTATION. ISO 2014

Copyright notice
This ISO document is a Draft International Standard and is copyright-protected by ISO. Except as
permitted under the applicable laws of the user’s country, neither this ISO draft nor any extract
from it may be reproduced, stored in a retrieval system or transmitted in any form or by any means,
electronic, photocopying, recording or otherwise, without prior written permission being secured.
Requests for permission to reproduce should be addressed to either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Reproduction may be subject to royalty payments or a licensing agreement.
Violators may be prosecuted.
ii © ISO 2014 – All rights reserved

ISO/DIS 7637-3
Contents Page
Foreword . iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Test methods . 1
4.1 General . 1
4.2 Standard test conditions . 3
4.3 Ground plane . 3
4.4 General test set-up conditions . 3
4.5 CCC method . 4
4.6 DCC method . 7
4.7 ICC method . 12
5 Test instrument description and specification . 15
5.1 Power supply . 15
5.2 Oscilloscope . 16
5.3 Transient pulses generator . 16
5.4 CCC fixture . 20
5.5 DCC fixture . 22
5.6 ICC fixture. 22
Annex A (normative) Calibration fixture used for the ICC test method . 23
Annex B (informative) Example of test severity levels associated with functional performance
status classification . 24
B.1 General . 24
B.2 Classification of transient pulses test severity level . 24
B.3 Example of FPSC application using transient pulses test severity levels . 25
Annex C (informative) Estimation of the inductive coupling factor . 26

ISO/DIS 7637-3
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 7637-3 was prepared by Technical Committee ISO/TC 22, Road vehicles, Subcommittee SC 3, Electric
and electronic equipment.
This third edition cancels and replaces the second edition (2007), of which has been technically revised.
ISO 7637 consists of the following parts, under the general title Road vehicles — Electrical disturbances from
conduction and coupling:
 Part 1: Definitions and general considerations
 Part 2: Electrical transient conduction along supply lines only
 Part 3: Vehicles with nominal 12 or 24 V supply voltage - Electrical transient transmission by capacitive
and inductive coupling via lines other than supply lines
Annex A forms an integral part of this part of ISO 7637.
Annexes B and C are informative.

iv © ISO 2014 – All rights reserved

ISO/DIS 7637-3
Introduction
Experience collected over a long period of immunity testing of instruments, devices and equipment (DUTs)
shows that a test simulating transient pulses coupling phenomena is needed for a sufficient coverage of the
wide range of electric and electromagnetic interferences. The knowledge of these facts is common among
EMC experts, and many companies have developed such coupling tests.
The fast transient pulse test uses bursts composed of a number of fast transient pulses, which are coupled
into lines (I/O lines in particular) of electronic equipment. The fast rise time, the repetition rate and the low
energy of the fast transient bursts are significant to the test.
The slow transient pulse test applies a number of single pulses, as used for conducted transient pulse test, to
the DUT.
During system development, the final application wiring harness is typically not available and the vehicle
electrical noises are not known. Therefore the test shall be performed with a standardized setup, represented
by the capacitive and inductive coupling described in this standard.

DRAFT INTERNATIONAL STANDARD ISO/DIS 7637-3

Road vehicles — Electrical disturbances from conduction and
coupling — Part 3: Electrical transient transmission by
capacitive and inductive coupling via lines other than supply
lines
1 Scope
This part of ISO 7637 defines bench test methods to evaluate the immunity of devices under test (DUTs) to
transient pulses coupled to lines other than supply lines. The test pulses simulate both fast and slow transient
disturbances caused by the switching of inductive loads and relay contact bounce.
Three test methods are described in this part of ISO 7637:
 the capacitive coupling clamp (CCC) method;
 the direct capacitive coupling (DCC) method; and
 the inductive coupling clamp (ICC) method.
This part of ISO 7637 applies to road vehicles fitted with nominal 12 V or 24 V electrical systems.
For transient pulses immunity, Annex B provides recommended test severity levels in line with the functional
performance status classification (FPSC) principle described in ISO 7637-1.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 7637-1, Road vehicles — Electrical disturbances from conduction and coupling — Part 1: Definitions and
general considerations
ISO 7637-2, Road vehicles — Electrical disturbances from conduction and coupling — Part 2: Electrical
transient conduction along supply lines only
ISO 11452-4, Road vehicles — Component test methods for electrical disturbances from narrowband radiated
electromagnetic energy — Part 4: Harness excitation methods
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 7637-1 apply.
4 Test methods
4.1 General
This clause describes bench test methods for testing the immunity of electrical system components or devices
under test (DUTs) against coupled transient pulses. These tests shall be performed in the laboratory.
ISO/DIS 7637-3
The defined transient pulses represent the characteristics of most of the known transient pulses which may
occur in the vehicle.
Some transient pulses tests may be omitted if a device, depending on its function or its configuration, is not
subjected to comparable transient pulses in the vehicle. It is part of the vehicle manufacturer's responsibility to
define the transient pulses tests needed for specific components.
A test plan shall be written to define
 the test methods to be used;
 the transient pulses tests to be applied;
 the transient pulses levels;
 the number of transient pulses to be applied;
 the DUT operating modes;
 the wiring harness (test versus production);
 the leads to be included in the capacitive coupling clamp, if used;
 the leads to be tested using the direct coupling capacitor method, if used;
 the capacitance values to be used, if the direct coupling capacitor method is used for specific
communication lines;
 the leads to be included in the inductive coupling clamp, if used; and
 the type of inductive coupling clamp, if the inductive coupling method is used.
Suggested values for the evaluation of immunity of DUTs can be chosen from Tables B.1, B.2.
The transient pulses test severity levels should be mutually agreed upon between the vehicle manufacturer
and the supplier prior to the test.
The applicability of the three different test methods is indicated in Table 1.
It is sufficient to select one test method for slow transient pulses and one test method for fast transient pulses.
Table 1 — Test method applicability
Transient pulses type CCC method DCC method ICC method
Slow transient pulses 2a of
Not applicable Applicable Applicable
5.3.3
Fast transient pulses 3a and
Applicable Applicable Not applicable
3b of 5.3.2
ISO/DIS 7637-3
4.2 Standard test conditions
The ambient temperature during the test shall be (23  5) °C.
Unless otherwise defined in this part of ISO 7637, the tolerance on time, resistance and capacitance is
 10 %.
10
Unless otherwise defined in this part of ISO 7637, the tolerance on voltage is %.


The supply voltage shall be as shown in Table 2 unless other values are agreed upon by the users of this part
of ISO 7637 and shall be documented in the test plan and in the test report.
Table 2 — Test voltages
Nominal system voltage Test voltage
V V
12 13  1
26  2
4.3 Ground plane
The ground plane shall be made of 0,5 mm thick (minimum) copper, brass or galvanized steel.
The minimum width of the ground plane shall be 1 000 mm.
The minimum length of the ground plane shall be 2 000 mm, or underneath the entire equipment plus 200
mm, whichever is larger.
4.4 General test set-up conditions
The DUT is arranged and connected according to its requirements. The DUT should be connected to the
original operating devices (loads, sensors, etc.) using the test setup d
...


INTERNATIONAL ISO
STANDARD 7637-3
Third edition
2016-07-01
Road vehicles — Electrical
disturbances from conduction and
coupling —
Part 3:
Electrical transient transmission by
capacitive and inductive coupling via
lines other than supply lines
Véhicules routiers — Perturbations électriques par conduction et par
couplage —
Partie 3: Transmission des perturbations électriques par couplage
capacitif ou inductif le long des lignes autres que les lignes
d’alimentation
Reference number
©
ISO 2016
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Test methods . 2
4.1 General . 2
4.2 Standard test conditions . 3
4.3 Ground plane . 3
4.4 General test setup conditions . 3
4.5 CCC method . 3
4.5.1 General. 3
4.5.2 Generator verification . 3
4.5.3 Transient pulses level adjustment . 4
4.5.4 DUT test . 4
4.6 DCC method . 5
4.6.1 General. 5
4.6.2 Generator verification . 6
4.6.3 Transient pulses level adjustment . 6
4.6.4 DUT test . 7
4.7 ICC method .11
4.7.1 General.11
4.7.2 Generator verification .11
4.7.3 Transient pulses level adjustment .11
4.7.4 DUT test .12
5 Test instrument description and specification .14
5.1 Power supply .14
5.2 Oscilloscope .15
5.3 Transient pulses generator .15
5.3.1 General.15
5.3.2 Slow transient pulses test 2a .15
5.3.3 Fast transient pulses 3a and 3b test .16
5.4 CCC fixture .18
5.5 DCC fixture .20
5.6 ICC fixture .20
Annex A (normative) Calibration fixture used for the ICC test method .21
Annex B (informative) Example of test severity levels associated with functional
performance status classification .22
Annex C (informative) Estimation of the inductive coupling factor .24
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information.
The committee responsible for this document is ISO/TC 22, Road vehicles, Subcommittee SC 32, Electrical
and electronic components and general system aspects.
This third edition cancels and replaces the second edition (ISO 7637–3:2007), which has been
technically revised.
ISO 7637 consists of the following parts, under the general title Road vehicles — Electrical disturbances
from conduction and coupling:
— Part 1: Definitions and general considerations
— Part 2: Electrical transient conduction along supply lines only
— Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than
supply lines
The following parts are under preparation:
— Part 4: Electrical transient conduction along shielded high voltage supply lines only
— Part 5: Enhanced definitions and verification methods for harmonization of pulse generators according
to ISO 7637‑2 [Technical Report]
Annex A forms an integral part of this part of ISO 7637.
Annex B and Annex C are informative.
iv © ISO 2016 – All rights reserved

Introduction
The fast transient pulse test uses bursts composed of a number of fast transient pulses, which are
coupled into lines (I/O lines in particular) of electronic equipment. The fast rise time, the repetition
rate and the low energy of the fast transient bursts are significant to the test.
The slow transient pulse test applies a number of single pulses, as used for conducted transient pulse
test, to the DUT.
INTERNATIONAL STANDARD ISO 7637-3:2016(E)
Road vehicles — Electrical disturbances from conduction
and coupling —
Part 3:
Electrical transient transmission by capacitive and
inductive coupling via lines other than supply lines
1 Scope
This part of ISO 7637 defines bench test methods to evaluate the immunity of devices under test (DUTs)
to transient pulses coupled to lines other than supply lines. The test pulses simulate both fast and slow
transient disturbances caused by the switching of inductive loads and relay contact bounce.
The following three test methods are described in this part of ISO 7637:
— capacitive coupling clamp (CCC) method;
— direct capacitive coupling (DCC) method;
— inductive coupling clamp (ICC) method.
This part of ISO 7637 applies to road vehicles fitted with nominal 12 V or 24 V electrical systems.
For transient pulses immunity, Annex B provides recommended test severity levels in line with the
functional performance status classification (FPSC) principle described in ISO 7637-1.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 7637-1, Road vehicles — Electrical disturbances from conduction and coupling — Part 1: Definitions
and general considerations
ISO 7637-2, Road vehicles — Electrical disturbances from conduction and coupling — Part 2: Electrical
transient conduction along supply lines only
ISO 11452-4, Road vehicles — Component test methods for electrical disturbances from narrowband
radiated electromagnetic energy — Part 4: Harness excitation methods
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 7637-1 apply.
4 Test methods
4.1 General
This Clause describes bench test methods for testing the immunity of electrical system components
or devices under test (DUTs) against coupled transient pulses. These tests shall be performed in the
laboratory.
The defined transient pulses represent the characteristics of most of the known transient pulses which
may occur in the vehicle.
Some transient pulse tests may be omitted if a device, depending on its function or its configuration,
is not subjected to comparable transient pulses in the vehicle. It is part of the vehicle manufacturer’s
responsibility to de
...