Determination of RF field strength, power density and SAR in the vicinity of base stations for the purpose of evaluating human exposure

IEC 62232:2025 provides methods for the determination of RF field strength, power density and specific absorption rate (SAR) in the vicinity of base stations (BS) for the purpose of evaluating human exposure.
This document:
a) considers intentionally radiating BS which transmit on one or more antennas using one or more frequencies in the range 110 MHz to 300 GHz;
b) considers the impact of ambient sources on RF exposure at least in the 100 kHz to 300 GHz frequency range;
c) specifies the methods to be used for RF exposure evaluation for compliance assessment applications, namely:
1) product compliance – determination of compliance boundary information for a BS product before it is placed on the market;
2) product installation compliance – determination of the total RF exposure levels in accessible areas from a BS product and other relevant sources before the product is put into operation;
3) in-situ RF exposure assessment – measurement of in-situ RF exposure levels in the vicinity of a BS installation after the product has been taken into operation;
d) specifies how to perform RF exposure assessment based on the actual maximum approach;
e) describes several RF field strength, power density, and SAR measurement and computation methodologies with guidance on their applicability to address both the in-situ evaluation of installed BS and laboratory-based evaluations;
f) describes how surveyors establish their specific evaluation procedures appropriate for their evaluation purpose;
g) provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value;
h) provides methods for the RF exposure assessment of BS using time-varying beam-steering technologies such as new radio (NR) BS using massive multiple input multiple output (MIMO).
NOTE 1 Practical implementation case studies are provided as examples in the companion Technical Report IEC TR 62669 [5].
NOTE 2 Although the current BS product types have been specified to operate up to 200 GHz (see, for example, [6] and [7]), the upper frequency of 300 GHz is consistent with applicable exposure limits.
NOTE 3 The lower frequency considered for ambient sources, 100 kHz, is derived from ICNIRP-1998 [2] and ICNIRP-2020 [1]. However, some applicable exposure guidelines require ambient fields to be evaluated as low as 3 kHz, e.g. Safety Code 6 [4] and IEEE Std C95.1-2019 [3].
NOTE 4 Specification of appropriate RF exposure mitigation measures such as signage, access control, and training are beyond the scope of this document. It is possible to refer to the applicable regulations or recommended practices on these topics.
NOTE 5 While this document is based on the current international consensus about the best engineering practice for assessing the compliance of RF exposure with the applicable exposure limits, it is possible that national regulatory agencies specify different requirements. The entity conducting an RF exposure assessment needs to be aware of the applicable regulations.
This fourth edition cancels and replaces the third edition published in 2022. It includes corrections of obvious errors and text improvements on the third edition in order to bring more clarity in the description of the assessment methods and avoid misinterpretations. This edition has the same technical content as the third edition.

Détermination de l'intensité du champ de radiofréquences, de la densité de puissance et du DAS à proximité des stations de base dans le but d'évaluer l'exposition humaine

IEC 62232:2025 donne des méthodes de détermination de l'intensité de champ RF, de la densité de puissance et du débit d'absorption spécifique (DAS) à proximité des stations de base (BS) dans le but d'évaluer l'exposition humaine.
Le présent document:
a) examine des BS rayonnant intentionnellement qui émettent sur une ou plusieurs antennes dans la plage de fréquences de 110 MHz à 300 GHz;
b) étudie l'impact des sources ambiantes d'exposition RF au moins dans la plage de fréquences de 100 kHz à 300 GHz;
c) spécifie les méthodes d'évaluation de l'exposition RF à utiliser pour les applications d'appréciation de la conformité, à savoir:
1) conformité du produit: détermination des informations sur la frontière de conformité d'un produit BS avant sa commercialisation;
2) conformité de l'installation du produit: détermination des niveaux d'exposition RF totaux dans les zones accessibles depuis un produit BS et les autres sources pertinentes avant la mise en service du produit;
3) appréciation de l'exposition RF sur site: mesurage des niveaux d'exposition RF sur site à proximité d'une installation BS après la mise en service du produit;
d) spécifie la manière de procéder à l'appréciation de l'exposition RF en s'appuyant sur l'approche fondée sur la réelle maximale;
e) décrit plusieurs méthodologies de mesure et de calcul de l'intensité de champ RF, de la densité de puissance et du DAS avec des recommandations relatives à leur applicabilité pour couvrir tant l'évaluation sur site des BS installées que les évaluations en laboratoire;
f) décrit la manière dont les vérificateurs établissent leurs propres procédures d'évaluation, en fonction de leurs objectifs d'évaluation;
g) fournit des recommandations quant à la manière de rendre compte, d'interpréter et de comparer les résultats obtenus à partir de différentes méthodologies d'évaluation et, lorsque l'objectif de l'évaluation l'exige, prendre une décision justifiée en vertu d'une valeur limite donnée;
h) fournit les méthodes d'appréciation de l'exposition RF de la BS à l'aide de technologies à orientation de faisceau variable dans le temps telles que les BS New Radio (NR) qui utilisent la technologie de système massif à entrée multiple et sortie multiple (MIMO, Multiple Input Multiple Output).
NOTE 1 Des exemples d'études de cas de mise en œuvre pratique sont donnés dans le Rapport technique d'accompagnement IEC TR 62669 [5].
NOTE 2 Bien que les produits BS actuels soient conçus pour fonctionner jusqu'à 200 GHz (voir par exemple [6] et [7]), la fréquence supérieure de 300 GHz est cohérente avec les limites d'exposition applicables.
NOTE 3 La fréquence inférieure prise en considération pour les sources ambiantes, 100 kHz, provient de l'ICNIRP 1998 [2] et de l'ICNIRP-2020 [1]. Toutefois, certaines lignes directrices applicables en matière d'exposition exigent d'évaluer les champs ambiants à des valeurs aussi basses que 3 kHz (Code de sécurité 6 [4] et IEEE Std C95.1-2019 [3], par exemple).
NOTE 4 La spécification de mesures appropriées d'atténuation de l'exposition RF, telles que la signalisation, le contrôle d'accès et la formation, ne relève pas du domaine d'application du présent document. Il est possible de consulter les règlements applicables ou les pratiques recommandées sur ces sujets.
NOTE 5 Bien que le présent document repose sur le consensus international actuel concernant les meilleures pratiques d'ingénierie pour apprécier la conformité de l'exposition RF aux limites d'exposition applicables, il est possible que les agences nationales de réglementation spécifient des exigences différentes. Il est nécessaire que l'entité qui réalise une appréciation de l'exposition RF connaisse les règlements applicables.
Cette quatrième édition annule et remplace la troisième édition parue en 2022. Il vient corriger des erreurs manifestes et améliorer la rédaction de la troisième édition afin d'apporter plus de clarté à la description des méthodes d'évaluation et d'éviter tout

General Information

Status
Published
Publication Date
28-Apr-2025
Current Stage
PPUB - Publication issued
Start Date
29-Apr-2025
Completion Date
15-Apr-2025
Ref Project

Relations

Standard
IEC 62232:2025 - Determination of RF field strength, power density and SAR in the vicinity of base stations for the purpose of evaluating human exposure Released:29. 04. 2025 Isbn:9782832703168
English and French language
738 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 62232 ®
Edition 4.0 2025-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Determination of RF field strength, power density and SAR in the vicinity of base
stations for the purpose of evaluating human exposure

Détermination de l'intensité du champ de radiofréquences, de la densité de
puissance et du DAS à proximité des stations de base dans le but d'évaluer
l'exposition humaine
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et
les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Secretariat Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigendum or an amendment might have been published.

IEC publications search - webstore.iec.ch/advsearchform
IEC Products & Services Portal - products.iec.ch
The advanced search enables to find IEC publications by a Discover our powerful search engine and read freely all the
variety of criteria (reference number, text, technical publications previews, graphical symbols and the glossary.
committee, …). It also gives information on projects, replaced With a subscription you will always have access to up to date
and withdrawn publications. content tailored to your needs.

IEC Just Published - webstore.iec.ch/justpublished
Electropedia - www.electropedia.org
Stay up to date on all new IEC publications. Just Published
The world's leading online dictionary on electrotechnology,
details all new publications released. Available online and once
containing more than 22 500 terminological entries in English
a month by email.
and French, with equivalent terms in 25 additional languages.

Also known as the International Electrotechnical Vocabulary
IEC Customer Service Centre - webstore.iec.ch/csc
(IEV) online.
If you wish to give us your feedback on this publication or need

further assistance, please contact the Customer Service
Centre: sales@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.

Recherche de publications IEC -  IEC Products & Services Portal - products.iec.ch
webstore.iec.ch/advsearchform Découvrez notre puissant moteur de recherche et consultez
La recherche avancée permet de trouver des publications IEC gratuitement tous les aperçus des publications, symboles
en utilisant différents critères (numéro de référence, texte, graphiques et le glossaire. Avec un abonnement, vous aurez
comité d’études, …). Elle donne aussi des informations sur les toujours accès à un contenu à jour adapté à vos besoins.
projets et les publications remplacées ou retirées.

Electropedia - www.electropedia.org
IEC Just Published - webstore.iec.ch/justpublished
Le premier dictionnaire d'électrotechnologie en ligne au monde,
Restez informé sur les nouvelles publications IEC. Just
avec plus de 22 500 articles terminologiques en anglais et en
Published détaille les nouvelles publications parues.
français, ainsi que les termes équivalents dans 25 langues
Disponible en ligne et une fois par mois par email.
additionnelles. Egalement appelé Vocabulaire

Electrotechnique International (IEV) en ligne.
Service Clients - webstore.iec.ch/csc

Si vous désirez nous donner des commentaires sur cette
publication ou si vous avez des questions contactez-nous:
sales@iec.ch.
IEC 62232 ®
Edition 4.0 2025-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Determination of RF field strength, power density and SAR in the vicinity of

base stations for the purpose of evaluating human exposure

Détermination de l'intensité du champ de radiofréquences, de la densité de

puissance et du DAS à proximité des stations de base dans le but d'évaluer

l'exposition humaine
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 13.280, 17.240 ISBN 978-2-8327-0316-8

– 2 – IEC 62232:2025 © IEC 2025
CONTENTS
FOREWORD . 16
INTRODUCTION . 18
1 Scope . 19
2 Normative references . 20
3 Terms and definitions . 21
4 Symbols and abbreviated terms . 37
4.1 Physical quantities . 37
4.2 Constants . 37
4.3 Abbreviated terms. 38
5 How to use this document . 41
5.1 Quick start guide . 41
5.2 RF evaluation purpose categories . 43
5.3 Implementation case studies . 43
6 Evaluation processes for product compliance, product installation compliance and
in-situ RF exposure assessments . 43
6.1 Evaluation process for product compliance . 43
6.1.1 General. 43
6.1.2 Establishing compliance boundaries . 44
6.1.3 Iso-surface compliance boundary definition . 44
6.1.4 Simple compliance boundaries . 44
6.1.5 Methods for establishing the compliance boundary . 46
6.1.6 Uncertainty . 50
6.1.7 Reporting for product compliance . 51
6.2 Evaluation process used for product installation compliance . 52
6.2.1 General. 52
6.2.2 General evaluation procedure for product installations . 52
6.2.3 Product installation compliance based on the actual maximum
transmitted power or EIRP . 53
6.2.4 Product installation data collection . 57
6.2.5 Simplified product installation evaluation process . 57
6.2.6 Assessment area selection . 61
6.2.7 Measurements . 62
6.2.8 Computations . 64
6.2.9 Uncertainty . 65
6.2.10 Reporting for product installation compliance . 65
6.3 In-situ RF exposure evaluation or assessment process . 66
6.3.1 General. 66
6.3.2 In-situ measurement process . 66
6.3.3 Site analysis . 67
6.3.4 Case A evaluation . 68
6.3.5 Case B evaluation . 68
6.3.6 Uncertainty . 69
6.3.7 Reporting . 69
6.4 Averaging procedures . 70
6.4.1 Spatial averaging . 70
6.4.2 Time averaging . 70
7 Determining the evaluation method . 70

7.1 Overview . 70
7.2 Process to determine the evaluation method . 70
7.2.1 General. 70
7.2.2 Establishing the evaluation points in relation to the source-environment
plane . 71
7.2.3 Exposure metric selection . 73
8 Evaluation methods . 74
8.1 General . 74
8.2 Measurement methods . 74
8.2.1 General. 74
8.2.2 RF field strength and power density measurements . 75
8.2.3 SAR measurements . 76
8.3 Computation methods . 76
8.4 Methods for assessment based on actual maximum approach . 78
8.4.1 General requirements . 78
8.4.2 Actual transmitted power or EIRP monitoring . 79
8.4.3 Actual transmitted power or EIRP control . 79
8.5 Methods for the assessment of RF exposure to multiple sources . 80
8.6 Methods for establishing the BS transmitted power or EIRP . 82
9 Uncertainty . 82
10 Reporting . 83
10.1 General requirements. 83
10.2 Report format . 83
10.3 Opinions and interpretations . 84
Annex A (informative) Source-environment plane and guidance on the evaluation
method selection . 85
A.1 Guidance on the source-environment plane . 85
A.1.1 General. 85
A.1.2 Source-environment plane example . 85
A.1.3 Source regions . 86
A.2 Select between computation or me
...