IEC 60704-2-3:1987
(Main)Test code for the determination of airborne acoustical noise emitted by household and similar electrical appliances. Part 2: Particular requirements for dishwashers
Test code for the determination of airborne acoustical noise emitted by household and similar electrical appliances. Part 2: Particular requirements for dishwashers
The contents of the corrigendum of December 1989 have been included in this copy.
Code d'essai pour la détermination du bruit aérien émis par les appareils électrodomestiques et analogues. Deuxième partie: Règles particulières pour les lave-vaisselle
Le contenu du corrigendum de décembre 1989 a été pris en considération dans cet exemplaire.
General Information
Relations
Standards Content (Sample)
---------------------- P
...
This May Also Interest You
IEC 60704-2-3:2017 is intended to be used in conjunction with the third edition (2010) of IEC 60704-1, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.
The relevant text of Part 1 as amended by this standard establishes the test code for dishwashers.
This edition includes the following significant technical changes with respect to the previous edition:
a) it doesn’t contain the description of an appropriate test enclosure because the test enclosure has been incorporated in IEC 60704-1:2010, Annex B;
b) the values of standard deviations of sound power levels determined according to this part are given in Clause 1;
c) to prevent an appliance being programmed to recognize the test cycles, and reacting specifically to them, in this new edition an artificial soil is used in addition to the unsoiled load and the rinse aid container has to be filled. This artificial soil successive may build up a film on the load. Therefore, detergent also has to be used. An initial test has shown that no foam is to be expected.
This publication is to be read in conjunction with IEC 60704-1:2010.
- Standard25 pagesEnglish and French languagesale 15% off
Applies to single-unit electric dishwashers for household and similar use, with or without automatic programme control, for cold and/or hot water supply, for detachable or permanent connection to water supply or sewage systems, intended for placing on the floor against a wall, for building-in or placing under a counter, a kitchen worktop or under a sink, for wall-mounting or on a counter. Limitations for the use of this test code are given in 1.1.1 of IEC 60704-1.
- Standard14 pagesEnglish languagesale 15% off
- Standard27 pagesEnglish and French languagesale 15% off
- Standard25 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 60704-2-3:2017 is intended to be used in conjunction with the third edition (2010) of IEC 60704-1, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.
The relevant text of Part 1 as amended by this standard establishes the test code for dishwashers.
This edition includes the following significant technical changes with respect to the previous edition:
a) it doesn’t contain the description of an appropriate test enclosure because the test enclosure has been incorporated in IEC 60704-1:2010, Annex B;
b) the values of standard deviations of sound power levels determined according to this part are given in Clause 1;
c) to prevent an appliance being programmed to recognize the test cycles, and reacting specifically to them, in this new edition an artificial soil is used in addition to the unsoiled load and the rinse aid container has to be filled. This artificial soil successive may build up a film on the load. Therefore, detergent also has to be used. An initial test has shown that no foam is to be expected.
This publication is to be read in conjunction with IEC 60704-1:2010.
- Standard25 pagesEnglish and French languagesale 15% off
Applies to single-unit electric dishwashers for household and similar use, with or without automatic programme control, for cold and/or hot water supply, for detachable or permanent connection to water supply or sewage systems, intended for placing on the floor against a wall, for building-in or placing under a counter, a kitchen worktop or under a sink, for wall-mounting or on a counter. Limitations for the use of this test code are given in 1.1.1 of IEC 60704-1.
- Standard14 pagesEnglish languagesale 15% off
- Standard27 pagesEnglish and French languagesale 15% off
- Standard25 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 63461:2024 applies to laboratory model tests of any type of Pelton hydraulic turbine with unit power greater than 5 MW. It contains the rules governing test conduct and provides measures to be taken if any phase of the tests is disputed.
The main objectives of this document are:
- to define the terms and quantities used;
- to specify methods of testing and of measuring the quantities involved, in order to ascertain the hydraulic performance of the model;
- to specify the methods of computation of results and of comparison with guarantees;
- to determine if the contract guarantees that fall within the scope of this document have been fulfilled;
- and to define the extent, content and structure of the final report.
Full application of the procedures herein described is not generally justified for machines with smaller power. Nevertheless, this document can be used for such machines by agreement between the purchaser and the supplier.
- Standard1 pageEnglish and French languagesale 15% off
IEC TR 61850-90-30:2025, which is a Technical Report, describes extensions of the SCL Substation/Process Section allowing the creation of a comprehensive, IED and hardware independent specification of an IEC 61850 based power system.
It addresses how to:
• decompose functions in SCL
• show function classifications in SCL
• relate functions with the SCL Substation and Process Section
• relate functions to Logical Nodes and IEDs/Specification IEDs
• present information flow between functions in a hardware/implementation independent way
• position Functions in relation to "Application Schemes", "Distributed Functions", "Protection Schemes"
• consider the relationship to Basic Application Profiles (BAP) defined in IEC TR 61850-7-6
The document addresses the engineering process as far as it is related to the specification of Functions and their instantiation in IEC 61850 based power system. This includes the impact on the SCL Process Section during system configuration.
The engineering process related to the definition of Applications and their instantiation is addressed in the Basic Application Profile Document (BAP) in IEC TR 61850-7-6.
The System Configuration process is described in IEC 61850-6.
Modifications and extensions of SCL are done in a way to guarantee backwards compatibility.
In addition, this document introduces:
• Some further elements to SCL that improve the content and usefulness of SSD files and facilitate the handling of SCL files for engineering purposes,
• New variants of IED specific files: ISD file and FSD files,
• Evolution of the engineering rights management, to first improve the usage of SED and add a new concept of System Configuration Collaboration (SCC file) which allows collaboration on the same project with different engineers.
- Technical report184 pagesEnglish languagesale 15% off
IEC TR 63515:2025 provides a conceptual framework for power system resilience. It covers the definition, evaluation metrics and methods, improvement strategies and uses cases of power system resilience. This document is applicable to developing resilient power system and implementing resilience improvement strategies.
This document is not exhaustive, and it is possible to consider other aspects, such as different application scenarios, evaluation methods, and improvement measures.
- Technical report39 pagesEnglish languagesale 15% off
IEC TR 62282-7-3:2025 is a generic assessment of the feasibility of standardizing accelerated test procedures (both proton exchange membrane (PEM) and oxide ion-conducting solid oxide cell (SOC) technologies) for fuel cell stacks that have been engineered for a specific system application. This document comprises a review of literature and projects, a discussion of the main physical phenomena of interest in accelerated testing campaigns (focusing on the cell and stack levels, not looking at the system as a black box), a compendium of measurement techniques that are applicable, and it suggests a macroscopic approach to the formulation of a representative accelerated testing campaign.
- Technical report29 pagesEnglish languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.