CLC/TS 50131-11:2012/IS1:2014
Alarm systems - Intrusion and hold-up systems - Part 11: Hold-up devices
Alarm systems - Intrusion and hold-up systems - Part 11: Hold-up devices
This Technical Specification is for dedicated hold-up devices in buildings, e.g. deliberately operated hold-up devices which can be triggered to create a hold-up alarm signal or message. It provides four security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free hold-up devices and uses Environmental Classes I-IV (see EN 50130-5). This Technical Specification does not include requirements for hold-up devices intended for use outdoors, or for mobile hold-up devices or for devices with functions additional to hold-up facility. NOTE If a device provides functions additional to hold-up facility, it is recommended to function similar to the requirement described in this Technical Specification. Functions additional to the mandatory functions as specified in this Technical Specification may be included in the hold-up device, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 11: Anforderungen an Überfallmelder
Systèmes d’alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 11: Exigences pour bouton anti-agression
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 11. del: Zahteve za javljalnike ropa - Dopolnilo IS1
Ta tehnična specifikacija je namenjena namenskim napravam za javljanje vloma v objektih, npr. namerno upravljane naprave za javljanje vloma, ki lahko ob sprožitvi proizvedejo alarm ali sporočilo o vlomu. Določa štiri varnostne razrede 1–4 (glejte standard EN 50131-1), specifične ali nespecifične ožičene ali brezžične naprave za javljanje vloma ter uporablja okoljske razrede I–IV (glejte standard EN 50130-5). Ta tehnična specifikacija ne zajema zahtev za naprave za javljanje vloma, ki so namenjene za uporabo na prostem, ali za mobilne naprave za javljanje vloma ali za naprave, ki poleg funkcije javljanja vloma vključujejo še druge funkcije. OPOMBA: Če naprava poleg funkcije javljanja vloma zagotavlja dodatne funkcije, je priporočeno, da deluje na način, ki je podoben zahtevi iz te tehnične specifikacije. Poleg obveznih funkcij, ki so opredeljene v tej tehnični specifikaciji, ima lahko naprava za javljanje vloma tudi dodatne funkcije, pri čemer te ne smejo neugodno vplivati na pravilno delovanje obveznih funkcij. Ta tehnična specifikacija se ne uporablja za povezave sistema.
General Information
- Status
- Published
- Publication Date
- 27-Feb-2014
- Technical Committee
- CLC/TC 79 - Alarm systems
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 28-Feb-2014
- Completion Date
- 28-Feb-2014
Relations
- Revises
CLC/TS 50131-11:2012 - Alarm systems - Intrusion and hold-up systems - Part 11: Hold-up devices - Effective Date
- 29-Jan-2023
Overview
CLC/TS 50131-11:2012/IS1:2014 sets technical specifications for dedicated hold-up devices used in modern alarm systems, focusing on deliberate activation in buildings to trigger a hold-up alarm signal. Published by CLC, this standard complements the broader EN 50131 series on intrusion and hold-up systems. It specifies performance, testing, and operational requirements for in-building, purpose-built hold-up devices - whether wired or wireless - across four security grades (1 to 4) and various environmental settings as classified by EN 50130-5.
This technical specification does not address outdoor, mobile, or multifunction devices, but recommends that any additional features included do not affect the essential hold-up function. The guidance is relevant for test houses, manufacturers, designers, system integrators, and specifiers working to ensure compliance, reliability, and safety in security systems.
Key Topics
- Dedicated Hold-up Devices: Focus on devices installed inside buildings, meant to be manually and deliberately activated in emergency situations to signal a hold-up.
- Security Grading (Grades 1-4): Alignment with EN 50131-1 classification for levels of protection and risk environments.
- Wired and Wireless Options: Applicability to both specific and non-specific connection methods, including wire-free solutions.
- Environmental Classes (I-IV): Use of EN 50130-5 environmental categories to ensure device suitability for indoor locations ranging from controlled to harsh conditions.
- Testing and Calibration: Guidance for reproducible testing methodology, such as use of standardized NeoDym magnets for consistency, especially useful for test houses and certification bodies.
- Function Integrity: Requirement that any additional device functions must not compromise the core hold-up facility.
Applications
- Banking and Retail Security: Ideal for environments where staff may need to discreetly activate a hold-up alarm during robberies or duress situations, such as at teller stations or cash desks.
- Commercial and Office Buildings: Suitable for reception areas, security offices, or secure rooms needing rapid and unmistakable alarm activation in emergencies.
- Integrated Intrusion Detection Systems: Forms a key component in broader building alarm systems, ensuring coordinated response in the event of hold-up or attempted robbery.
- Compliance and Certification: Essential for manufacturers and system integrators seeking compliance with European technical standards for security alarm systems.
Organizations implementing alarm systems can rely on this specification to select, test, and validate hold-up devices that satisfy regulatory and operational requirements. Adherence to these guidelines raises the reliability of alarm response, reduces false alarms, and promotes user safety.
Related Standards
For optimal system design, deployment, and verification, consider the following associated standards:
- EN 50131-1: Alarm systems - Intrusion and hold-up systems - Part 1: System requirements (basis for Grades 1-4).
- EN 50130-5: Alarm systems - Environmental test methods for alarm system equipment.
- EN 60404-5 & EN 60404-14: Magnetic materials – Methods for measurement of magnetic properties and dipole moments, vital for testing device components.
- IEC 60404-8-1: Specifications for magnetically hard materials, supporting test magnet requirements.
- Other Parts of EN 50131 series: Covering different aspects of intrusion and hold-up systems, such as control panels, warning devices, and interconnections.
Keywords: hold-up devices, alarm systems, intrusion detection, CLC/TS 50131-11, security standards, wired wireless hold-up alarms, EN 50131-1, EN 50130-5, alarm system testing, security grading, building security standards, compliance, alarm manufacturing, CENELEC standards.
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
CLC/TS 50131-11:2012/IS1:2014 is a addendum published by CLC. Its full title is "Alarm systems - Intrusion and hold-up systems - Part 11: Hold-up devices". This standard covers: This Technical Specification is for dedicated hold-up devices in buildings, e.g. deliberately operated hold-up devices which can be triggered to create a hold-up alarm signal or message. It provides four security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free hold-up devices and uses Environmental Classes I-IV (see EN 50130-5). This Technical Specification does not include requirements for hold-up devices intended for use outdoors, or for mobile hold-up devices or for devices with functions additional to hold-up facility. NOTE If a device provides functions additional to hold-up facility, it is recommended to function similar to the requirement described in this Technical Specification. Functions additional to the mandatory functions as specified in this Technical Specification may be included in the hold-up device, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.
This Technical Specification is for dedicated hold-up devices in buildings, e.g. deliberately operated hold-up devices which can be triggered to create a hold-up alarm signal or message. It provides four security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free hold-up devices and uses Environmental Classes I-IV (see EN 50130-5). This Technical Specification does not include requirements for hold-up devices intended for use outdoors, or for mobile hold-up devices or for devices with functions additional to hold-up facility. NOTE If a device provides functions additional to hold-up facility, it is recommended to function similar to the requirement described in this Technical Specification. Functions additional to the mandatory functions as specified in this Technical Specification may be included in the hold-up device, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.
CLC/TS 50131-11:2012/IS1:2014 is classified under the following ICS (International Classification for Standards) categories: 13.310 - Protection against crime. The ICS classification helps identify the subject area and facilitates finding related standards.
CLC/TS 50131-11:2012/IS1:2014 has the following relationships with other standards: It is inter standard links to CLC/TS 50131-11:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
CLC/TS 50131-11:2012/IS1:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2014
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 11. del: Zahteve za javljalnike
ropa - Dopolnilo IS1
Alarm systems - Intrusion and hold-up systems -- Part 11: Hold-up devices
Alarmanlagen - Einbruch- und Überfallmeldeanlagen -- Teil 11: Anforderungen an
Überfallmelder
Systèmes d’alarme - Systèmes d'alarme contre l’intrusion et les hold-up -- Partie 11:
Exigences pour bouton anti-agression
Ta slovenski standard je istoveten z: CLC/TS 50131-11:2012/IS1:2014
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
INTERPRETATION SHEET
CLC/TS 50131-11/IS1
FEUILLE D'INTERPRETATION
February 2014
INTERPRETATIONSBLATT
ICS 13.310
English version
Alarm systems -
Intrusion and hold-up systems -
Part 11: Hold-up devices
Systèmes d’alarme - Alarmanlagen -
Systèmes d'alarme contre l’intrusion et les Einbruch- und Überfallmeldeanlagen -
hold-up - Teil 11: Anforderungen an Überfallmelder
Partie 11: Exigences pour bouton anti-
agression
This Technical Specification was approved by CENELEC on 2013-12-23.
CENELEC members are required to announce the existence of this TS in the same way as for an EN and to
make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting
national standards in force.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. CLC/TS 50131-11:2012/IS1:2014 E
Contents Page
Foreword . 3
Clause: . 4
Question: . 4
Interpretation: . 4
Validity: . 4
Foreword
This Interpreta
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...