EN 50131-2-7-1:2012/A2:2016
(Amendment)Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic)
Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic)
Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.7.4 Immunity to Hard objects hitting the glass & Annex B
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 2-7-1: Einbruchmelder - Glasbruchmelder (Akustisch)
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et les hold-up - Partie 2-7-1: Détecteurs d'intrusion - Détecteurs bris de glace (acoustiques)
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-7-1. del: Zahteve za javljalnike vloma - Javljalniki loma stekla (akustični) - Dopolnilo A2
General Information
- Status
- Published
- Publication Date
- 09-Jun-2016
- Withdrawal Date
- 10-Apr-2019
- Technical Committee
- CLC/TC 79 - Alarm systems
- Drafting Committee
- CLC/TC 79 - Alarm systems
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 10-Jun-2016
- Due Date
- 03-Mar-2017
- Completion Date
- 10-Jun-2016
Relations
- Effective Date
- 09-Feb-2026
- Effective Date
- 25-Jan-2023
Overview
EN 50131-2-7-1:2012/A2:2016 is a key European standard issued by CENELEC (CLC) concerning alarm systems, specifically focusing on intrusion and hold-up systems and their acoustic glass break detectors. This amendment modifies select chapters of EN 50131-2-7-1:2012, improving test methodologies for glass break detectors and updating requirements related to immunity performance. The updated requirements, particularly in Chapter 6.7.4 and Annex B, support consistent product testing and reliable intrusion detection in modern security systems.
Key Topics
Scope of Amendment:
The amendment introduces changes to key testing procedures, allowing products to meet updated compliance for acoustic glass break detectors used in intrusion detection.Testing Procedure Adjustments:
- Angle Change for Hard Object Testing:
- The angle for testing the immunity of detectors to hard objects hitting glass is revised to 27° ± 1°, replacing the previous 60° ± 5° requirement.
- Glass Pane Specification Update:
- The standard size for immunity test glass panes remains 800 mm by 1 m, but the thickness is increased from 4 mm ± 1 mm to 6 mm ± 1 mm, maintaining the requirement for framed, standard plate glass.
- Angle Change for Hard Object Testing:
Enhanced Reliability:
By precisely defining the physical parameters for test conditions, the amendment fortifies the repeatability and comparability of detector performance across the industry.
Applications
EN 50131-2-7-1:2012/A2:2016 is essential for manufacturers, installers, and specifiers of security alarm systems who require reliable intrusion detection technology. Its practical benefits include:
- Security System Design:
- Ensures that acoustic glass break detectors are rigorously tested for immunity against false alarms caused by hard objects with defined impact angles and glass criteria.
- Supports architects, engineers, and facility managers in selecting compliant detectors for commercial, residential, and industrial properties.
- Product Certification and Testing:
- Provides manufacturers with precise criteria for product development and third-party testing, streamlining the path to European market access.
- Facilitates product differentiation through compliance with up-to-date security standards.
- Regulatory Compliance:
- Assists security integrators and consultants with documentation required for regulatory and insurance purposes, reflecting adherence to current EU best practices for intrusion detection systems.
Related Standards
For optimal implementation and full system compliance, consider these associated standards:
- EN 50131 (All Parts):
Core European standards for intrusion and hold-up alarm systems, covering general system requirements, system components, and application guidelines. - EN 50131-1:
General requirements for intrusion and hold-up systems. - EN 50136 Series:
Alarm transmission systems and equipment. - EN 50130 Series:
Provides environmental and electromagnetic compatibility (EMC) requirements for alarm system components. - IEC 62642 Series:
International equivalents for intrusion and hold-up alarm systems, supporting global compliance and interoperability.
Keywords: EN 50131-2-7-1, acoustic glass break detector standard, intrusion alarm systems, hold-up alarm systems, alarm system compliance, CENELEC, glass break detector test, security system standards, alarm component testing, European alarm standards
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
EN 50131-2-7-1:2012/A2:2016 is a amendment published by CLC. Its full title is "Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic)". This standard covers: Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.7.4 Immunity to Hard objects hitting the glass & Annex B
Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.7.4 Immunity to Hard objects hitting the glass & Annex B
EN 50131-2-7-1:2012/A2:2016 is classified under the following ICS (International Classification for Standards) categories: 13.320 - Alarm and warning systems. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 50131-2-7-1:2012/A2:2016 has the following relationships with other standards: It is inter standard links to EN 15999-2:2025, EN 50131-2-7-1:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 50131-2-7-1:2012/A2:2016 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2016
$ODUPQLVLVWHPL6LVWHPL]DMDYOMDQMHYORPDLQURSDGHO=DKWHYH]D
MDYOMDOQLNHYORPD-DYOMDOQLNLORPDVWHNODDNXVWLþQL'RSROQLOR$
Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass
break detectors (acoustic)
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 2-7-1: Einbruchmelder -
Glasbruchmelder (Akustisch)
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et les hold-up - Partie 2-7-1:
Détecteurs d'intrusion - Détecteurs bris de glace (acoustiques)
Ta slovenski standard je istoveten z: EN 50131-2-7-1:2012/A2:2016
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 50131-2-7-1:2012/A2
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2016
ICS 13.320
English Version
Alarm systems - Intrusion and hold-up systems - Part 2-7-1:
Intrusion detectors - Glass break detectors (acoustic)
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil
les hold-up - Partie 2-7-1: Détecteurs d'intrusion - 2-7-1: Einbruchmelder - Glasbruchmelder (Akustisch)
Détecteurs bris de glace (acoustiques)
This amendment A2 modifies the European Standard EN 50131-2-7-1:2012; it was approved by CENELEC on 2016-04-11. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the offic
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...