EN 60601-2-29:1995
(Main)Medical electrical equipment - Part 2: Particular requirements for the safety of radiotherapy simulators
Medical electrical equipment - Part 2: Particular requirements for the safety of radiotherapy simulators
This clause of the General Standard applies, except as follows: 1.1 Scope Addition: This Standard applies to RADIOTHERAPY SIMULATORS which use diagnostic X-RAY EQUIPMENT to simulate physically a therapeutic RADIATION BEAM. So that the TREATMENT VOLUME to be irradiated during RADIOTHERAPY can be localized, and the position and size of the therapeutic RADIATION FIELD can be confirmed. This Standard applies to RADIOTHERAPY SIMULATORS using HIGH-VOLTAGE GENERATORS complying with EN 60601-2-7. This Standard applies to RADIOTHERAPY SIMULATORS intended exclusively for RADIOTHERAPY simulation as a prelude to intended RADIOTHERAPY, and not for any other purpose such as general diagnostic examinations. This Standard applies to RADIOTHERAPY SIMULATORS comprising the following parts: a} A system for producing a RADIATION BEAM not exceeding 400 kV which simulates the geometry of the RADIOTHERAPY RADIATION BEAM. b) A system for producing images of the transmitted X-RAY BEAM, for example either by RADIOGRAPHY or by RADIOSCOPY. C) An assembly to control the size of the RADIATION BEAM and to DELINEATE the intended treatment area. d) A mechanical structure which physically simulates the geometry and motions of the RADIOTHERAPY EQUIPMENT and supports the imaging system. e) A PATIENT SUPPORT system.
Medizinische elektrische Geräte - Teil 2: Besondere Festlegungen für die Sicherheit von Strahlentherapiesimulatoren
Appareils électromédicaux - Partie 2: Règles particulières de sécurité des simulateurs de radiothérapie
Medical electrical equipment - Part 2: Particular requirements for the safety of radiotherapy simulators (IEC 60601-2-29:1993)
General Information
- Status
- Withdrawn
- Publication Date
- 29-Nov-1995
- Withdrawal Date
- 30-Jun-1996
- Technical Committee
- CLC/TC 62 - Electrical equipment in medical practice
- Drafting Committee
- IEC/SC 62C - IEC_SC_62C
- Parallel Committee
- IEC/SC 62C - IEC_SC_62C
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Apr-2002
- Completion Date
- 01-Apr-2002
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 29-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.
Sponsored listings
Frequently Asked Questions
EN 60601-2-29:1995 is a standard published by CLC. Its full title is "Medical electrical equipment - Part 2: Particular requirements for the safety of radiotherapy simulators". This standard covers: This clause of the General Standard applies, except as follows: 1.1 Scope Addition: This Standard applies to RADIOTHERAPY SIMULATORS which use diagnostic X-RAY EQUIPMENT to simulate physically a therapeutic RADIATION BEAM. So that the TREATMENT VOLUME to be irradiated during RADIOTHERAPY can be localized, and the position and size of the therapeutic RADIATION FIELD can be confirmed. This Standard applies to RADIOTHERAPY SIMULATORS using HIGH-VOLTAGE GENERATORS complying with EN 60601-2-7. This Standard applies to RADIOTHERAPY SIMULATORS intended exclusively for RADIOTHERAPY simulation as a prelude to intended RADIOTHERAPY, and not for any other purpose such as general diagnostic examinations. This Standard applies to RADIOTHERAPY SIMULATORS comprising the following parts: a} A system for producing a RADIATION BEAM not exceeding 400 kV which simulates the geometry of the RADIOTHERAPY RADIATION BEAM. b) A system for producing images of the transmitted X-RAY BEAM, for example either by RADIOGRAPHY or by RADIOSCOPY. C) An assembly to control the size of the RADIATION BEAM and to DELINEATE the intended treatment area. d) A mechanical structure which physically simulates the geometry and motions of the RADIOTHERAPY EQUIPMENT and supports the imaging system. e) A PATIENT SUPPORT system.
This clause of the General Standard applies, except as follows: 1.1 Scope Addition: This Standard applies to RADIOTHERAPY SIMULATORS which use diagnostic X-RAY EQUIPMENT to simulate physically a therapeutic RADIATION BEAM. So that the TREATMENT VOLUME to be irradiated during RADIOTHERAPY can be localized, and the position and size of the therapeutic RADIATION FIELD can be confirmed. This Standard applies to RADIOTHERAPY SIMULATORS using HIGH-VOLTAGE GENERATORS complying with EN 60601-2-7. This Standard applies to RADIOTHERAPY SIMULATORS intended exclusively for RADIOTHERAPY simulation as a prelude to intended RADIOTHERAPY, and not for any other purpose such as general diagnostic examinations. This Standard applies to RADIOTHERAPY SIMULATORS comprising the following parts: a} A system for producing a RADIATION BEAM not exceeding 400 kV which simulates the geometry of the RADIOTHERAPY RADIATION BEAM. b) A system for producing images of the transmitted X-RAY BEAM, for example either by RADIOGRAPHY or by RADIOSCOPY. C) An assembly to control the size of the RADIATION BEAM and to DELINEATE the intended treatment area. d) A mechanical structure which physically simulates the geometry and motions of the RADIOTHERAPY EQUIPMENT and supports the imaging system. e) A PATIENT SUPPORT system.
EN 60601-2-29:1995 is classified under the following ICS (International Classification for Standards) categories: 11.040.60 - Therapy equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60601-2-29:1995 has the following relationships with other standards: It is inter standard links to EN 60601-2-29:1999, EN 60601-2-29:1995/A1:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60601-2-29:1995 is associated with the following European legislation: EU Directives/Regulations: 93/42/EEC; Standardization Mandates: M/023. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 60601-2-29:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-1998
Medical electrical equipment - Part 2: Particular requirements for the safety of
radiotherapy simulators (IEC 60601-2-29:1993)
Medical electrical equipment -- Part 2: Particular requirements for the safety of
radiotherapy simulators
Medizinische elektrische Geräte -- Teil 2: Besondere Festlegungen für die Sicherheit von
Strahlentherapiesimulatoren
Appareils électromédicaux -- Partie 2: Règles particulières de sécurité des simulateurs
de radiothérapie
Ta slovenski standard je istoveten z: EN 60601-2-29:1995
ICS:
11.040.60 Terapevtska oprema Therapy equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...