EN 60060-2:1994/A11:1998
(Amendment)High-voltage test techniques - Part 2: Measuring systems
High-voltage test techniques - Part 2: Measuring systems
Superseded by EN 60060-2:2011
Hochspannungs-Prüftechnik - Teil 2: Meßsysteme
Techniques des essais à haute tension - Partie 2: Systèmes de mesure
High-voltage test techniques - Part 2: Measuring systems - Amendment 1
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2000
High-voltage test techniques - Part 2: Measuring systems - Amendment 1
High-voltage test techniques - Part 2: Measuring systems - Amendment 1
Hochspannungs-Prüftechnik -- Teil 2: Meßsysteme
Techniques des essais à haute tension -- Partie 2: Systèmes de mesure
Ta slovenski standard je istoveten z: EN 60060-2:1994/A11:1998
ICS:
19.080 (OHNWULþQRLQHOHNWURQVNR Electrical and electronic
SUHVNXãDQMH testing
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
IEC 60270:2025 is applicable to the charge-based measurement of partial discharges which occur in electrical apparatus, components or systems when tested with alternating voltages (AC) up to 500 Hz or with direct voltage (DC). This document: – defines the terms used; – defines the quantities to be measured; – describes the measurement frequencies as well as the test and measuring circuits which may be used; – defines analogue and digital measuring methods required for common applications; – specifies methods for calibration and requirements of instruments used for calibration; – gives guidance on test procedures; – gives some assistance concerning the discrimination of partial discharges from external interference. The provisions of this document are used in the drafting of specifications relating to partial discharge measurements for specific power apparatus. It deals with electrical measurements of impulsive (short-duration) partial discharges, but reference is also made to non-electrical methods primarily used for partial discharge location (see Annex F). Diagnosis of the behaviour of specific power apparatus can be aided by digital processing of partial discharge data (see Annex E) and also by non-electrical methods that are primarily used for partial discharge location (see Annex F). This document is primarily concerned with electrical measurement of partial discharge in terms of apparent charge for specific power apparatus made during tests with alternating voltage, but specific problems which arise when tests are made with direct voltage are considered in Clause 11. The terminology, definitions, basic test circuits and procedures often also apply to tests at other frequencies, but special test procedures and measuring system characteristics which are not considered in this document may be required. For measurements at higher frequency ranges, see IEC TS 62478. Annex A provides normative requirements for performance tests on calibrators. This fourth edition cancels and replaces the third edition published in 2000, and Amendment 1:2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Title modified. b) Use with alternating voltages up to 500 Hz or with direct voltage. c) Clear focus on charge-based partial discharge measurements. d) Streamlined performance checks for partial discharge measurement system components. e) Improved normative Annex A for performance tests on calibrators. f) Revised and new informative Annexes. In a future revision, this document will seek horizontal publication status in accordance with IEC Guide 108.
- Standard74 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60060-2:2025 is applicable to complete measuring systems and to their components, used for the measurement of high voltages during laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impulse voltages and combined and composite voltages as specified in IEC 60060-1. For measurements during on-site tests, see IEC 60060-3. The limits on uncertainties of measurements stated in this document apply to test levels stated in IEC 60071-1. The principles of this document apply also to higher levels but the uncertainty can be greater. This document: • defines the terms used; • describes methods to estimate the uncertainties of high-voltage measurements; • states the requirements that apply to measuring systems; • describes the methods for approving a measuring system and checking its components; • describes the procedures by which the user demonstrates that a measuring system meets the requirements of this document, including the limits set for the uncertainty of measurement. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) The general layout and text has been updated and improved to make the standard easier to use. b) This document has been revised to align it with the fourth edition of IEC 60060-1. c) The treatment of measurement uncertainty estimation has been expanded. d) This document is now applicable to measuring systems used in testing at all standard insulation levels specified in IEC 60071-1. e) The measurement uncertainty requirement for the front time of the standard lighting impulse voltage has been changed from 10 % to 15 %, for testing at all standard insulation levels specified in IEC 60071-1. f) The parameter "time-to-peak" of the switching impulse defined in the third edition of IEC 60060-1:2010 has been replaced by "front time" in the fourth edition of IEC 60060-1. Necessary changes have been made in this document to accommodate this change in IEC 60060-1. g) Clause 10, Measurement of combined voltages and Clause 11, Measurement of composite voltages have been added. h) Clause B.1 has been significantly revised to align more closely with the provisions of Clause 5, including using the same nomenclature.
- Standard91 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61083-3:2020 is applicable to digital recording instruments used for measurements during tests with high alternating and direct voltages and currents. It specifies the measuring characteristics and calibrations required to meet the measuring uncertainties and procedures specified in the relevant IEC standards (e.g. IEC 60060-1, IEC 60060-2, IEC 60060-3, IEC 62475, IEC 61180). This document is applicable to those digital recording instruments that will be designed and type tested according to this document. This document • defines performance requirements for digital recording instruments used during tests with alternating voltages and currents (AC) or direct voltages and currents (DC); • specifies the necessary requirements for such instruments to ensure their suitability for use under the relevant standards; • establishes the tests and procedures necessary to demonstrate their compliance; • defines the terms related to digital recording instruments with recording function and access to raw data. Examples of relevant alternating and direct voltages and currents to be measured are listed in Annex D. This International Standard has the status of a horizontal standard in accordance with IEC Guide 108.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61180:2016 is applicable to dielectric tests with direct voltage; dielectric tests with alternating voltage; dielectric tests with impulse voltage and test equipment used for dielectric tests on low-voltage equipment. This standard is applicable only to tests on equipment having a rated voltage of not more than 1 kV a.c. or 1,5 kV d.c. This standard is applicable to type and routine tests for objects which are subjected to high voltage tests as specified by the technical committee. The test equipment comprises a voltage generator and a measuring system. This standard covers test equipment in which the measuring system is protected against external interference and coupling by appropriate screening, for example a continuous conducting shield. Therefore, simple comparison tests are sufficient to ensure valid results. This standard is not intended to be used for electromagnetic compatibility tests on electric or electronic equipment. Tests with the combination of impulse voltages and currents are covered by IEC 61000-4-5. This standard provides the relevant technical committees as far as possible with: - defined terms of both general and specific applicability; - general requirements regarding test objects and test procedures; - methods for generation and measurement of test voltages; - test procedures; - methods for the evaluation of test results and to indicate criteria for acceptance; - requirements concerning approved measuring devices and checking methods and measurement uncertainty. Alternative test procedures may be required and these should be specified by the relevant technical committees. Care should be taken if the test object has voltage limiting devices, as they may influence the results of the test. The relevant technical committees should provide guidance for testing objects equipped with voltage limiting devices. This 1st edition of IEC 61180 cancels and replaces the 1st edition of IEC 61180-1, issued in 1992, and the 1st edition of IEC 61180-2, issued in 1994. Key words: High Voltage Test Techniques, Dielectric Tests, Disruptive Discharge, Withstand Voltage.
- Standard52 pagesEnglish languagesale 10% offe-Library read for×1 day
Applicable to the measurement of partial discharges which occur in electrical apparatus, components or systems when tested with alternating voltage up to 400 Hz or with direct voltage.
- Amendment14 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61083-2:2013 applies to software used for evaluation of impulse parameters from recorded impulse voltages and currents. It provides test waveforms and reference values for the software required to meet the measuring uncertainties and procedures specified in IEC 60060-1, IEC 60060-2, IEC 60060-3 and IEC 62475. Hardware with built-in firmware that cannot accept external numerical input data is not covered by this standard. The object of this standard is to establish the tests which are necessary to show that the performance of the software complies with the requirements of the relevant IEC standards, define the terms specifically related to digital processing, specify reference values and the acceptance limits for the reference impulses, specify the requirements for the record of performance and define the methods to assess the contribution of software to the measurement uncertainty. This second edition cancels and replaces the first edition published in 1996 and constitutes a technical revision. The main changes with respect to the previous edition are: - the test data generator software has been updated, - the number of reference impulse waveforms included in the test data generator has been significantly increased, - all reference values have been recalculated according to new definitions in IEC 60060-1 and IEC 62475 and - methods for estimating the uncertainty of parameter evaluation have been introduced and are in line with the procedure introduced in IEC 60060-2. Keywords: High voltage, High current, Impulse voltage, Impulse current.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60060-2:2010 is applicable to complete measuring systems, and to their components, used for the measurement of high voltages during laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impulse voltages as specified in IEC 60060-1. For measurements during on-site tests see IEC 60060-3. The limits on uncertainties of measurements stated in this standard apply to test levels stated in IEC 60071-1:2006. The principles of this standard apply also to higher levels but the uncertainty may be greater. This standard also defines the terms used, methods to estimate the uncertainties of high-voltage measurements, states the requirements which the measuring systems shall meet, describes the methods for approving a measuring system and checking its components and describes the procedures by which the user shall show that a measuring system meets the requirements of this standard, including the limits set for the uncertainty of measurement. This third edition cancels and replaces the second edition, published in 1994, and constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows: - The general layout and text was updated and improved to make the standard easier to use. - The standard was revised to align it with IEC 60060-1. - The treatment of measurement uncertainty estimation has been expanded.
- Standard76 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62475:2010 is applicable to high-current testing and measurements on both high-voltage and low-voltage equipment. It deals with steady-state and short-time direct current (as e.g. encountered in high-power d.c. testing), steady-state and short-time alternating current (as e.g. encountered in high-power a.c. testing), and impulse-current. In general, currents above 100 A are considered in this International Standard, although currents less than this can occur in tests. This standard also covers fault detection during, for example, lightning impulse testing.
- Standard106 pagesEnglish languagesale 10% offe-Library read for×1 day
Applicable to the following on-site test voltages and in service stresses, which are in relation to IEC 60060-1: direct voltage;alternating voltage; lightning impulse voltage of aperiodic or oscillating shape: switching impulse voltage of aperiodic or oscillating shape.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
Applies to the construction and use of sphere-gaps for measuring the peak value of alternating, direct and both full standard and longer tail impulse voltages. Peak values of the disruptive voltages in air are given in tabular form. Note: - For high-voltage test techniques, see EN 60.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion