EN 55020:2002/IS2:2007
Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement
Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement
Applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals. This standard is also applicable to the immunity of outdoor units of direct to home (DTH) satellite receiving systems for individual reception. Defines the immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges. Immunity requirements are given in the frequency range 0 Hz to 400 GHz. Test requirements are specified for each port (enclosure or connector) considered.
Ton- und Fernseh-Rundfunkempfänger und verwandte Geräte der Unterhaltungselektronik - Störfestigkeitseigenschaften - Grenzwerte und Prüfverfahren
Récepteurs de radiodiffusion et de télévision et équipements associés - Caractéristiques d'immunité - Limites et méthodes de mesure
Traite des exigences d'immunité relatives aux récepteurs de télévision, aux récepteurs de radiodiffusion sonore et aux appareils associés destinés à être utilisés dans un environnement résidentiel, commercial et dans l'industrie légère. Décrit les méthodes de mesure et spécifie des valeurs limites applicables aux récepteurs de radiodiffusion sonore et visuelle et aux équipements qui leur sont associés vis-à-vis de leurs caractéristiques d'immunité aux signaux non désirés. Concerne aussi l'immunité des unités extérieures des systèmes de réception individuelle par satellite. Définit les exigences pour les essais d'immunité aux perturbations continues et transitoires, conduites et rayonnées, y compris les décharges électrostatiques, pour les appareils définis dans le domaine d'application. Les exigences d'immunité sont données dans la bande de fréquences de 0 Hz à 400 GHz. Les essais prescrits sont spécifiés pour chaque accès (enveloppe ou connecteur) considéré.
Zvokovni in radiodifuzijski sprejemniki s pripadajočo opremo - Karakteristike odpornosti proti motnjam - Mejne vrednosti in metode merjenja - Razlaga točke 4.3.4 standarda EN 55020:2002
Razlaga točke 4.3.4 standarda EN 55020:2002
General Information
- Status
- Withdrawn
- Publication Date
- 08-Jan-2007
- Withdrawal Date
- 08-Jul-2007
- Technical Committee
- CLC/TC 210 - Electromagnetic Compatibility (EMC)
- Drafting Committee
- IEC/SC CISPR/I - IEC_SC_CISPR/I
- Parallel Committee
- IEC/SC CISPR/I - IEC_SC_CISPR/I
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Dec-2009
- Completion Date
- 01-Dec-2009
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 29-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard
TL 9000 QuEST Forum
Telecommunications quality management system.

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
Sponsored listings
Frequently Asked Questions
EN 55020:2002/IS2:2007 is a addendum published by CLC. Its full title is "Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement". This standard covers: Applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals. This standard is also applicable to the immunity of outdoor units of direct to home (DTH) satellite receiving systems for individual reception. Defines the immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges. Immunity requirements are given in the frequency range 0 Hz to 400 GHz. Test requirements are specified for each port (enclosure or connector) considered.
Applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals. This standard is also applicable to the immunity of outdoor units of direct to home (DTH) satellite receiving systems for individual reception. Defines the immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges. Immunity requirements are given in the frequency range 0 Hz to 400 GHz. Test requirements are specified for each port (enclosure or connector) considered.
EN 55020:2002/IS2:2007 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 55020:2002/IS2:2007 has the following relationships with other standards: It is inter standard links to EN 55020:2007, EN 55020:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 55020:2002/IS2:2007 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2007
=YRNRYQLLQUDGLRGLIX]LMVNLVSUHMHPQLNLVSULSDGDMRþRRSUHPR.DUDNWHULVWLNH
RGSRUQRVWLSURWLPRWQMDP0HMQHYUHGQRVWLLQPHWRGHPHUMHQMD5D]ODJDWRþNH
VWDQGDUGD(1
Interpretation of Subclause 4.3.4 of EN 55020:2002
Interpretation zum Unterabschnitt 4.3.4 der EN 55020:2002
Interprtation du Paragraphe 4.3.4 de la EN 55020:2002
Ta slovenski standard je istoveten z: EN 55020:2002/IS2:2007
ICS:
33.100.20 Imunost Immunity
33.160.01 Avdio, video in avdiovizualni Audio, video and audiovisual
sistemi na splošno systems in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 55020/IS2
Interpretation Sheet 2
EN 55020:2002
English version
___________
Foreword
This Interpretation Sheet to the European Standard EN 55020:2002 was prepared by the Interpretation Panel
of the Technical Committee CENELEC TC 210, Electromagnetic compatibility (EMC). The text of the draft
was submitted to the Unique Acceptance Procedure and was approved by CENELEC on 2006-07-01.
Subclause 4.3.4 – Requirements for screening effectiveness
Requirements for screening effectiveness apply to the coaxial antenna terminals, if any.
Measurements shall be made in accordance with 5.5.
Background:
One of the immunity tests described in EN 55020:2002, is the measurement of screening effectiveness
(Subclause 4.3.4). The method prescribe
...