Standard Test Method for Performance of Rack Conveyor Commercial Dishwashing Machines

SIGNIFICANCE AND USE
5.1 The maximum energy input rate test is used to confirm that the dishwasher is operating at the manufacturer's rated input prior to further testing. This test method also will indicate any problems with the electric power supply, gas service pressure, or steam supply flow or pressure.  
5.2 Tank and booster temperatures, as well as water consumption, are adjusted to NSF specifications to insure that the test is applied to a properly functioning dishwasher.  
5.3 Because much of a dishwasher's operating period is spent in the idle condition, tank heater and booster idle energy consumption rate(s) are important parts of predicting dishwasher's energy consumption.  
5.4 The washing energy performance test determines energy usage per rack. This is useful both as a measure for comparing the energy performance of one dishwasher to another and as a predictor of the dishwasher’s energy consumption.  
5.5 Water-consumption characterization is useful for estimating water and sewage costs associated with dishwashing machine operation.
SCOPE
1.1 This test method evaluates the energy and water consumption of rack conveyor, commercial dishwashing machines, hereafter referred to as dishwashers. Dishwashers may have remote or self-contained booster heater. This procedure does not address cleaning or sanitizing performance.  
1.2 This test method is applicable to both hot water sanitizing and chemical sanitizing rack conveyor machines, which include both single tank and multiple tank machines. Rackless conveyors (i.e. flight type machines) are included. Dishwasher tank heaters are evaluated separately from the booster heater. Machines designed to be interchangeable in the field from high temp and low temp (i.e. Dual Sanitizing Machines) and vice versa, shall be tested at both settings. Machines should be set for factory settings. If a dishwasher includes a prewash tank heater as an option, energy should be submetered separately for the prewash tank heater. This test method may be used for dishwashers with steam coil tank or booster heat, but not dishwashers with steam injection tank or booster heat. When the test method specifies to use the data plate or manufacturer’s recommendations, instructions, specifications, or requirements, the information source shall be used in the following order of preference and documented in the test report: data plate, user manual, communication with manufacturer.  
1.3 The following procedures are included in this test method:  
1.3.1 Procedures to Confirm Dishwasher is Operating Properly Prior to Performance Testing:  
1.3.1.1 Maximum energy input rate of the tank heaters (10.5).
1.3.1.2 Maximum energy input rate of the booster heater, if applicable (10.6).
1.3.1.3 Final sanitizing rinse water consumption calibration (10.7).
1.3.1.4 Booster temperature calibration, if applicable (10.2).
1.3.1.5 Wash tank temperature calibration (10.3).
1.3.1.6 Wash tank pump and conveyor motor calibration (10.4).  
1.3.2 Energy Usage and Cycle Rate Performance Tests:  
1.3.2.1 Washing energy performance test (10.8).
1.3.2.2 Tank heater idle energy rate (10.9).
1.3.2.3 Booster idle energy rate, if provided (10.10).  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Jul-2015
Current Stage
Ref Project

Buy Standard

Standard
ASTM F1920-15 - Standard Test Method for Performance of Rack Conveyor Commercial Dishwashing Machines
English language
18 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM F1920-15 - Standard Test Method for Performance of Rack Conveyor Commercial Dishwashing Machines
English language
18 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F1920 − 15 An American National Standard
Standard Test Method for
Performance of Rack Conveyor Commercial Dishwashing
1
Machines
This standard is issued under the fixed designation F1920; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.3.1.5 Wash tank temperature calibration (10.3).
1.3.1.6 Wash tank pump and conveyor motor calibration
1.1 This test method evaluates the energy and water con-
(10.4).
sumption of rack conveyor, commercial dishwashing
1.3.2 Energy Usage and Cycle Rate Performance Tests:
machines, hereafter referred to as dishwashers. Dishwashers
1.3.2.1 Washing energy performance test (10.8).
may have remote or self-contained booster heater. This proce-
1.3.2.2 Tank heater idle energy rate (10.9).
dure does not address cleaning or sanitizing performance.
1.3.2.3 Booster idle energy rate, if provided (10.10).
1.2 This test method is applicable to both hot water sanitiz-
1.4 The values stated in inch-pound units are to be regarded
ing and chemical sanitizing rack conveyor machines, which
as standard. The values given in parentheses are mathematical
include both single tank and multiple tank machines. Rackless
conversions to SI units that are provided for information only
conveyors (i.e. flight type machines) are included. Dishwasher
and are not considered standard.
tank heaters are evaluated separately from the booster heater.
1.5 This standard does not purport to address all of the
Machinesdesignedtobeinterchangeableinthefieldfromhigh
safety concerns, if any, associated with its use. It is the
temp and low temp (i.e. Dual Sanitizing Machines) and vice
responsibility of the user of this standard to establish appro-
versa, shall be tested at both settings. Machines should be set
priate safety and health practices and determine the applica-
for factory settings. If a dishwasher includes a prewash tank
bility of regulatory limitations prior to use.
heaterasanoption,energyshouldbesubmeteredseparatelyfor
the prewash tank heater. This test method may be used for
2. Referenced Documents
dishwashers with steam coil tank or booster heat, but not
2
2.1 ASTM Standards:
dishwashers with steam injection tank or booster heat. When
D3588Practice for Calculating Heat Value, Compressibility
thetestmethodspecifiestousethedataplateormanufacturer’s
Factor, and Relative Density of Gaseous Fuels
recommendations,instructions,specifications,orrequirements,
F858Specification for Hot Water Sanitizing Commercial
the information source shall be used in the following order of
Dishwashing Machines, Single Tank, Conveyor Rack
preference and documented in the test report: data plate, user
Type
manual, communication with manufacturer.
F861Specification for Commercial Dishwashing Racks
1.3 The following procedures are included in this test
2.2 NSF Standards:
method:
3
NSF/ANSI 3Commercial Warewashing Equipment
1.3.1 Procedures to Confirm Dishwasher is Operating
3
NSF/ANSI 170Glossary of Foodservice Terms
Properly Prior to Performance Testing:
2.3 ASHRAE Standard:
1.3.1.1 Maximum energy input rate of the tank heaters
ASHRAE Guideline 2–1986 (RA90)Engineering Analysis
(10.5).
4
of Experimental Data
1.3.1.2 Maximum energy input rate of the booster heater, if
applicable (10.6).
3. Terminology
1.3.1.3 Final sanitizing rinse water consumption calibration
3.1 Definitions of Terms Specific to This Standard:
(10.7).
1.3.1.4 Boostertemperaturecalibration,ifapplicable(10.2).
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
1
This test method is under the jurisdiction of ASTM Committee F26 on Food the ASTM website.
3
Service Equipment and is the direct responsibility of Subcommittee F26.06 on Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd.,Ann
Productivity and Energy Protocol. Arbor, MI 48113-0140, http://www.nsf.org.
4
Current edition approved Aug. 1, 2015. Published October 2015. Originally Available from American Society of Heating, Refrigerating, and Air-
approved in 1998. Last previous edition approved in 2011 as F1920–11. DOI: Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA
10.1520/F1920-15. 30329, http://www.ashrae.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1920 − 15
3.1.1 ambient temperature, n—defined in NSF/ANSI 170- waythatmodelissetupinitially.These
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F1920 − 11 F1920 − 15 An American National Standard
Standard Test Method for
Performance of Rack Conveyor,Conveyor Commercial
1
Dishwashing Machines
This standard is issued under the fixed designation F1920; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method evaluates the energy and water consumption of rack conveyor, commercial dishwashing machines,
hereafter referred to as dishwashers. Dishwashers may have remote or self-contained booster heater. This procedure does not
address cleaning or sanitizing performance.
1.2 This test method is applicable to both hot water sanitizing and chemical sanitizing rack conveyor machines, which include
both single tank and multiple tank machines. Rackless conveyors (i.e. flight type machines) are included. Dishwasher tank heaters
are evaluated separately from the booster heater. Machines designed to be interchangeable in the field from high temp and low temp
(i.e. Dual Sanitizing Machines) and vice versa, shall be tested at both settings. Machines should be set for factory settings. If a
dishwasher includes a prewash tank heater as an option, energy should be submetered separately for the prewash tank heater. This
test method may be used for dishwashers with steam coil tank or booster heat, but not dishwashers with steam injection tank or
booster heat. When the test method specifies to use the data plate or manufacturer’s recommendations, instructions, specifications,
or requirements, the information source shall be used in the following order of preference and documented in the test report: data
plate, user manual, communication with manufacturer.
1.3 The following procedures are included in this test method:
1.3.1 Procedures to Confirm Dishwasher is Operating Properly Prior to Performance Testing:
1.3.1.1 Maximum energy input rate of the tank heaters (10.210.5).
1.3.1.2 Maximum energy input rate of the booster heater, if applicable (10.310.6).
1.3.1.3 Final sanitizing rinse water consumption calibration (10.410.7).
1.3.1.4 Booster temperature calibration, if applicable (10.510.2).
1.3.1.5 Wash tank temperature calibration (10.610.3).
1.3.1.6 Wash tank pump and conveyor motor calibration (10.710.4).
1.3.2 Energy Usage and Cycle Rate Performance Tests:
1.3.2.1 Washing energy performance test (10.8).
1.3.2.2 Tank heater idle energy rate (10.9).
1.3.2.3 Booster idle energy rate, if provided (10.10).
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D3588 Practice for Calculating Heat Value, Compressibility Factor, and Relative Density of Gaseous Fuels
F858 Specification for Hot Water Sanitizing Commercial Dishwashing Machines, Single Tank, Conveyor Rack Type
F861 Specification for Commercial Dishwashing Racks
1
This test method is under the jurisdiction of ASTM Committee F26 on Food Service Equipment and is the direct responsibility of Subcommittee F26.06 on Productivity
and Energy Protocol.
Current edition approved June 1, 2011Aug. 1, 2015. Published July 2011October 2015. Originally approved in 1998. Last previous edition approved in 20072011 as
F1920 – 07.F1920 – 11. DOI: 10.1520/F1920-11.10.1520/F1920-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1920 − 15
2.2 NSF Standards:
3
NSF/ANSI 3 Commercial Warewashing Equipment
3
NSF/ANSI 170 Glossary of Foodservice Terms
2.3 ASHRAE Standard:
4
ASHRAE Guideline 2–1986 (RA90) Engineering Analysis of Experimental Data
3. Terminology
3.1 Definitions o
...