ASTM E2127-01a
(Test Method)Standard Methods of Static Load Test for Combined Tensile and Transverse Load Resistance of Paneled Wall Systems in Building Construction
Standard Methods of Static Load Test for Combined Tensile and Transverse Load Resistance of Paneled Wall Systems in Building Construction
SCOPE
1.1 These test methods cover the procedures for determining the resistance of paneled wall systems subjected to combined lateral loads and axial loads.
1.2 These test methods involve the simultaneous application of transverse (lateral wind) and tensile (wind uplift) loads to paneled wall system assemblies anchored at both ends with hold-down connectors.
1.3 These test methods are suitable for determining the structural adequacy of the design, system, and wall fabrication technique, and are not intended to evaluate the strength capacity of the hold-down connectors.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
Designation:E2127–01a
Standard Methods of
Static Load Test for Combined Tensile and Transverse Load
Resistance of Paneled Wall Systems in Building
1
Construction
This standard is issued under the fixed designation E 2127; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope to the opposing end while applying a transverse load; see Figs.
1 and 2. The forces required to deflect the specimen and the
1.1 These test methods cover the procedures for determin-
corresponding displacements at each load interval are mea-
ing the resistance of paneled wall systems subjected to com-
sured.
bined lateral loads and axial loads.
1.2 These test methods involve the simultaneous application
5. Significance and Use
of transverse (lateral wind) and tensile (wind uplift) loads to
5.1 The procedures described will test the behavior of
paneled wall system assemblies anchored at both ends with
segments of paneled wall system construction under conditions
hold-down connectors.
representative of those encountered in service. Performance
1.3 These test methods are suitable for determining the
criteria based on data from those procedures can verify
structural adequacy of the design, system, and wall fabrication
structural adequacy and service life.
technique, and are not intended to evaluate the strength
capacity of the hold-down connectors.
6. Test Apparatus
1.4 This standard does not purport to address all of the
6.1 Test Assembly:
safety concerns, if any, associated with its use. It is the
6.1.1 General—Tests shall be made on three like specimens
responsibility of the user of this standard to establish appro-
for each orientation.All system elements shall be fastened in a
priate safety and health practices and determine the applica-
manner to conform with the wall specifications. The wall
bility of regulatory limitations prior to use.
system shall be representative of actual building construction.
6.1.2 Connections—The performance of the wall is influ-
2. Referenced Documents
encedbythetypeandspacingoftheanchoringtotheupperand
2.1 ASTM Standards:
lower ends of the wall.
E 575 Practice for Reporting Data from Structural Tests of
6.1.3 Paneled Wall System Requirements—The paneled
Building Constructions, Elements, Connections, and As-
2 wall system specimen shall be comprised of members and
semblies
2 connectors representative of those used in building construc-
E 631 Terminology of Building Constructions
tion, except that the specimen is permitted to consist of a core
3. Terminology on which paneled wall system surface units are placed.
6.1.4 Test Setup—The paneled wall system specimen shall
3.1 Definitions—For definitions of general terms used in
be tested vertically or horizontally so that surface units may be
this test method, refer to Terminology E 631.
observed during the test. The test fixture shall allow for
4. Summary of Test Method
simultaneous transverse and tensile load application. The top
and bottom of the specimen shall be attached to rigid supports.
4.1 The tensile and bending capacity of the paneled wall
6.1.5 Paneled Wall System Size—The paneled wall system
system is determined by applying a simultaneous tensile and
specimen height shall not be less than the actual height of the
transverse load to a wall specimen. This is accomplished by
wall, and the width shall be minimum 48 in. (120 cm) wide, or
anchoring one end of the specimen and applying a tensile load
the width of an individual wall panel (if the individual panel
width is greater than 48 in. wide).
1
These test methods are under the jurisdiction of ASTM Committee E06 on
Performance of Buildings and are the direct responsibility of Subcommittee E06.11 7. Procedure
on Horizontal and Vertical Structures/Structural Performance of Completed Struc-
7.1 Number of Tests—Conduct a minimum of three tests for
tures.
each of the two orientations. Conduct the first set of tests with
Current edition approved Oct. 10, 2001. Published January 2002. Originally
published as E 2127–01. Last previous edition E 2127–01
the specimen orientation applicable to the positive pressure
2
Annual Book of ASTM Standards, Vol 04.11.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
E2127–01a
FIG. 1 Test Specimen and Fixture, Straps Up
loadapplication;seeFig.1;conductthesecondsetoftestswith 7.1.1.4
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.